• 제목/요약/키워드: Radiation sensor

검색결과 426건 처리시간 0.027초

프로토 타입 조직등가비례계수기의 중입자가속기연구소의 135 MeV/u 탄소 이온에 대한 선형에너지 스펙트럼 측정 (Measurement of Linear Energy Spectra for 135 MeV/u Carbon Beams in HIMAC Using Prototype TEPC)

  • 남욱원;이재진;표정현;박원기;문봉곤;임창휘;문명국;하시시 키다무라;신고 고바야시;김성환
    • 센서학회지
    • /
    • 제23권3호
    • /
    • pp.197-201
    • /
    • 2014
  • TEPC (Tissue Equivalent Proportional Counter) was usually used for high LET radiation dosimetry. We developed a prototype TEPC for micro-dosimetry in the range of $0.2{\sim}300 keV/{\mu}m$. And, the simulated site diameter of the TEPC is $2{\mu}m$, of similar size to a cell nucleus. For purposes of characterization the response for high LET radiation of the TEPC has been investigated under 135MeV/u Carbon ions in HIMAC (Heavy Ion Medical Accelerator). We determined the gas multiplication factor and measured the lineal energy spectrum [yd(y)] of 135 MeV/u Carbon ions. The value of the gas multiplication factor was 315 at 700 V bias voltage. As a result of the experiment, we could more understand the performance of the TEPC for high LET (Linear Energy Transfer) radiation. And the procedure of high LET radiation dosimetry using TEPC is established.

2차원 방사선준위 분포측정 시스템의 제작 및 특성 조사 (The Characteristics of Two-dimensional Radiation Monitoring System)

  • 김성환;한상효;김계령;강희동;최영수;이용범;이종민
    • 센서학회지
    • /
    • 제6권4호
    • /
    • pp.290-297
    • /
    • 1997
  • 본 연구에서는 CsI(TI) 섬광계수기를 이용하여 고방사선장에서 방사선준위분포를 측정할 수 있는 2차원 측정시스템을 개발하였다. 콜리메이터의 내경이 8 mm일 때 최적의 위치분해능과 검출효율을 얻었으며 이때 위치분해능은 1 m 거리에서 10 cm미만이었다. 그리고 시스템의 에너지 분해능은 Cs-137의 662 keV에 대하여 10 %, Co-60의 1.17 MeV에 대하여 7.6 %, 1.33 MeV에 대하여 5.8 %를 얻었다. 그리고 실제 방사선 선원에 대하여 그 분포를 측정할 수 있었다.

  • PDF

Preliminary Study on Rapid Measurement of Gross Alpha/Beta and 90Sr Activities in Surface Soil by Mobile ZnS(Ag)/PTV Array and Handheld PVT Rod with Gated Energy Channels

  • Lee, Chanki;Kim, Hee Reyoung
    • Journal of Radiation Protection and Research
    • /
    • 제46권4호
    • /
    • pp.194-203
    • /
    • 2021
  • Background: Surface soil radiation monitoring around nuclear facilities is important to classify and characterize the contaminated areas. A scanning and direct measurement technique can survey the sites rapidly before starting sampling analysis. Materials and Methods: Regarding this, we test and suggest a measurement technique for gross alpha/beta and 90Sr activities in surface soil based on a mobile ZnS(Ag)/PVT (polyvinyltoluene) array and a handheld PVT rod, respectively. To detect 90Sr selectively in soil mixed with naturally occurring radioactive materials, chosen energy channel counts from the multichannel analyzers were used instead of whole channel counts. Soil samples contaminated with exempt liquid 90Sr with 1 Bq·g-1, 3 Bq·g-1, and 10 Bq·g-1 were prepared and hardened by flocculation. Results and Discussion: The mobile ZnS(Ag)/PVT array could discriminate gross alpha, gross beta, and gamma radiation by the different pulse-shaped signal features of each sensor material. If the array is deployed on a vehicle, the scan minimum detectable concentration (MDC) range will be about 0.11-0.17 Bq·g-1 at 18 km·h-1 speed, highly sensitive to actual sites. The handheld PVT rod with 12 mm (Φ) × 20 mm (H) size can directly measure 90Sr selectively if channels on which energies are from 1,470 and 2,279 keV are gated, minimizing crossdetection of other radionuclides. These methods were verified by measuring soil samples fabricated with homogeneous 90Sr concentrations, showing static MDC of 2.16 Bq·g-1 at a measurement time of 300 seconds. Conclusion: Based on the results, comprehensive procedures using these detectors are suggested to optimize soil sites survey.

휴대용 검출기의 방사선 고감도 검출을 위한 SiPM 특성 분석 (Characteristics Analysis of SiPM for Detection of High Sensitivity of Portable Detectors)

  • 강병욱;유선국
    • 한국방사선학회논문지
    • /
    • 제17권6호
    • /
    • pp.897-902
    • /
    • 2023
  • 본 논문에서는 휴대용 X-ray 검출기의 방사선 고감도 검출에 대한 실현 가능 여부를 확인하기 위한 SiPM의 특성 분석을 목적으로 한다. 휴대용 X-ray 검출기는 환자의 위치에 빠르게 접근하여 실시간 이미지를 획득함으로써 의사들은 신속하게 진단을 수행할 수 있는 장점이 있지만 이러한 이동성은 선량 감지의 어려움을 동반한다. 기존 검출기에서는 SiPM을 X-ray Trigger를 판별하는 단순한 용도로 사용하고 있다. SiPM을 통한 X-ray의 고감도 검출 가능 여부를 확인하기 위해 7종의 SiPM Sensor를 비교 선정하고 특성 분석을 진행하였다. 최종 시험에 사용한 SiPM은 10 nGy 수준의 극저선량 조사 조건에서 Signal 구분이 가능하며, 관전압에 따라 Signal 상승곡선의 기울기가 변하는 것이 확인되었다. X-ray 선량에 따라 SiPM의 signal level 및 지속시간이 변화되는 특성을 이용한 고감도 측정이 가능할 것으로 보인다.

Development and Performance of a Hand-Held CZT Detector for In-Situ Measurements at the Emergency Response

  • Ji, Young-Yong;Chung, Kun Ho;Kim, Chang-Jong;Yoon, Jin;Lee, Wanno;Choi, Geun-Sik;Kang, Mun Ja
    • Journal of Radiation Protection and Research
    • /
    • 제41권2호
    • /
    • pp.87-91
    • /
    • 2016
  • Background: A hand-held detector for an emergency response was developed for nuclide identification and to estimate the information of the ambient dose rate in the scene of an accident as well as the radioactivity of the contaminants. Materials and Methods: To achieve this, the most suitable sensor was first selected as a cadmium zinc telluride (CZT) semiconductor and the signal processing unit from a sensor and the signal discrimination and storage unit were successfully manufactured on a printed circuit board. Results and Discussion: The performance of the developed signal processing unit was then evaluated to have an energy resolution of about 14 keV at 662 keV. The system control unit was also designed to operate the CZT detector, monitor the detector, battery, and interface status, and check and transmit the measured results of the ambient dose rate and radioactivity. In addition, a collimator, which can control the inner radius, and the airborne dust sampler, which consists of an air filter and charcoal filter, were developed and mounted to the developed CZT detector for the quick and efficient response of a nuclear accident. Conclusion: The hand-held CZT detector was developed to make the in-situ gamma-ray spectrometry and its performance was checked to have a good energy resolution. In addition, the collimator and the airborne dust sampler were developed and mounted to the developed CZT detector for a quick and efficient response to a nuclear accident.

형상계수와 태양추적장치를 이용한 헬리오스타트 제어 시스템 개발 (Development of Optimal Control of Heliostat System Using Configuration Factor and Solar Tracking Device)

  • 이동일;전우진;백승욱
    • 대한기계학회논문집B
    • /
    • 제36권12호
    • /
    • pp.1177-1183
    • /
    • 2012
  • 본 연구의 목적은 형상계수와 태양추적장치를 이용하여 헬리오스타트에서 흡수기로 복사열전달이 최대화 될 수 있는 시스템을 개발하는 것이다. 헬리오스타트에서 타워 상단에 위치한 흡수기로의 열전달은 대부분 복사에 의해 일어나기 때문에, 복사 열전달에서 사용되는 형상계수를 헬리오스타트 제어에 이용하였다. 태양 추적 및 태양 위치 계산은 CdS 센서와 시뮬링크 프로그램을 이용하였다. 시뮬링크 프로그램을 이용하여 실시간으로 헬리오스타트, 흡수기, 태양 사이의 형상계수가 최대화되는 알고리즘을 적용함으로서, 헬리오스타트에서 흡수기로의 복사 열전달이 최대화 될 수 있도록 하였다. 또한 다양한 조건에 따른 헬리오스타트 제어에 필요한 각을 시뮬레이션 함으로서 각 조건에 필요한 각을 도출할 수 있었다.

MT-CLIM 프로그램을 이용한 일별 일사량 추정의 국내 적용성 검토 (Applicability of Daily Solar Radiation Estimated by Mountain Microclimate Simulation Model (MT-CLIM) in Korea)

  • 심교문;김용석;이덕배;강기경;소규호
    • 한국농림기상학회지
    • /
    • 제14권4호
    • /
    • pp.260-264
    • /
    • 2012
  • MT-CLIM 컴퓨터 프로그램을 이용한 일사량 추정의 국내 적용성 검토를 위하여 경북 의성군 일대에 7개 관측지점을 설정하고 실측 일사량과 프로그램에 의한 추정 일사량을 비교 검증하였다. 추정 일사량을 실측 일사량과 비교한 결과, 둘 사이에 결정계수 0.52의 선형관계가 확인되었고, 전체적으로는 과대 추정되는 것으로 조사되었다. MT-CLIM 프로그램에 의한 일사추정값의 RMSE는 평균 $3.83MJ\;m^{-2}$ 이어서, 일 평균 일사량 $15.27MJ\;m^{-2}$의 25% 정도에 해당되었고, 본 연구에서 사용한 일사센서의 허용오차가 표준센서의 ${\pm}5%$인 점을 감안하면 25%의 RMSE는 실용성이 떨어진다고 판단할 수 있다. 따라서 MT-CLIM 프로그램을 국내 농업분야에 적용하기 위해서는 지형보정계수 등 신뢰도를 개선시킬 추가적인 방법들이 모색되어야 할 것으로 판단된다.

고준위방사성폐기물 처분장 고온 환경 조건에 대한 모니터링용 피에조 센서의 수명 평가 (Life assessment of monitoring piezoelectric sensor under high temperature at high-level nuclear waste repository)

  • 박창희;황현중;홍창호;김진섭;조계춘
    • 한국터널지하공간학회 논문집
    • /
    • 제25권6호
    • /
    • pp.509-523
    • /
    • 2023
  • 고준위방사성폐기물 처분장은 고온, 다습, 방사선의 복합적인 환경 조건에 노출되며 이로 인해 구조물의 열화가 가속된다. 따라서 처분장에 대한 구조물 건전성 모니터링이 필수적이며 균열 탐지, 강도 추정 등을 위해 피에조 센서가 활용된다. 다만 처분 터널 및 처분 용기에 설치되는 모니터링 센서는 교체 및 제거가 불가능하기 때문에 모니터링 센서의 정량적인 수명을 평가하고 적합성을 판단해야 한다. 본 연구에서는 가속수명시험을 활용하여 모니터링용 피에조 센서에 대한 수명을 평가하였다. 고온 조건에서 나타나는 피에조 센서의 고장 모드와 고장 메커니즘을 도출하였으며 온도 스트레스가 피에조 센서 수명에 미치는 영향을 분석하였다. 또한 온도 스트레스에 대한 가속수명시험을 수행하여 와이블 수명 확률 분포 및 아레니우스 가속모형을 통해 온도 스트레스와 피에조 센서 수명 간의 관계식을 제시하고 수명을 평가하였다. 본 연구에서 제시된 온도 스트레스와 수명 간의 관계를 통해 보다 정확한 수명 평가를 위한 복합스트레스 가속수명시험 설계에 도움이 될 것으로 판단된다.

가스보일러 일산화탄소 제어에 관한 연구 (A Study on the Control of the Exhaust CO from Gas Boiler)

  • 조영도;최경석;김지윤;깅창연
    • 한국가스학회지
    • /
    • 제5권1호
    • /
    • pp.7-14
    • /
    • 2001
  • 가정집 가스보일러 배기가스 조성에 대하여 열역학적 관점에서 해석하였고 일산화탄소 센서의 특성에 대하여 고찰하였다. 배기가스의 조성 측정으로부터 보일러 연소조건을 예측할 수 있음을 본 연구에서 제시하였다. 즉 배기가스중의 산소농도로부터 과잉 공기량을 예측할 수 있고, 배기가스중의 일산화탄소와 수소의 비율로부터 보일러 연소실 온도를 알 수 있다. 가정집에 설치되어 있는 보일러의 배기가스 조성 해석으로부터 과잉 공기량이 약 $55\~110\%$임을 알 수 있었다. 따라서 가정집 가스보일러에서 발생하는 일산화탄소는 연소가스의 유속구배에 의한 난류에 의한 국부냉각 또는 벽에 의한 국부냉각으로 등에 의하여 발생하는 것으로 사료된다. CO센서의 출력전압은 수소와 일산화탄소의 농도에 선형적으로 비례하며, 보일러에서 일산화탄소 발생을 CO센서와 연동제어로 감소시킬 수 있다.

  • PDF

다결정 CdTe 기반의 광계수형 X선 센서 제작 및 특성평가 (The Fabrication and Property Evaluation of Poly-crystalline CdTe based Photon Counting X-ray Sensor)

  • 강상식;박지군
    • 한국방사선학회논문지
    • /
    • 제9권7호
    • /
    • pp.439-443
    • /
    • 2015
  • 종래의 방사선 의료영상 센서는 방사선에 의해 생성된 전하신호를 화소내에서 적분하는 방식이다. 본 연구에서는 저선량에서 우수한 해상력이 가능한 광계수형 영상센서를 개발하기 위해 진공 열증착법을 이용하여 다결정 CdTe(p-CdTe) 필름을 제작하였다. 또한, 광계수형 센서의 성능평가를 위하여 물리적 특성(SEM, XRD) 및 전기적 특성(leakage current, x-ray sensitivity, SNR) 평가를 하였다. 측정 결과, $1V/{\mu}m$ 이하의 인가전압에서 $5nA/cm^2$ 이하의 누설 전류밀도를 보였으며, X선 발생신호량은 $7{\mu}C/cm^2{\cdot}R$으로 광계수형 센서로의 적용에 적합한 것으로 평가되었다. 또한, 신호대잡음비는 동작영역에서 5000 이상의 값을 보였다.