• 제목/요약/키워드: Radiation sensor

검색결과 426건 처리시간 0.023초

Reproduction strategy of radiation data with compensation of data loss using a deep learning technique

  • Cho, Woosung;Kim, Hyeonmin;Kim, Duckhyun;Kim, SongHyun;Kwon, Inyong
    • Nuclear Engineering and Technology
    • /
    • 제53권7호
    • /
    • pp.2229-2236
    • /
    • 2021
  • In nuclear-related facilities, such as nuclear power plants, research reactors, accelerators, and nuclear waste storage sites, radiation detection, and mapping are required to prevent radiation overexposure. Sensor network systems consisting of radiation sensor interfaces and wxireless communication units have become promising tools that can be used for data collection of radiation detection that can in turn be used to draw a radiation map. During data collection, malfunctions in some of the sensors can occasionally occur due to radiation effects, physical damage, network defects, sensor loss, or other reasons. This paper proposes a reproduction strategy for radiation maps using a U-net model to compensate for the loss of radiation detection data. To perform machine learning and verification, 1,561 simulations and 417 measured data of a sensor network were performed. The reproduction results show an accuracy of over 90%. The proposed strategy can offer an effective method that can be used to resolve the data loss problem for conventional sensor network systems and will specifically contribute to making initial responses with preserved data and without the high cost of radiation leak accidents at nuclear facilities.

수중 방사선 감시체계 구축을 위한 실시간 방사선 준위 모니터링 센서 개발 (Development of a Real-time Radiation Level Monitoring Sensor for Building an Underwater Radiation Monitoring System)

  • 박혜민;주관식
    • 센서학회지
    • /
    • 제24권2호
    • /
    • pp.96-100
    • /
    • 2015
  • In the present study, we developed a real-time radiation-monitoring sensor for an underwater radiation-monitoring system and evaluated its effectiveness using reference radiation sources. The monitoring sensor was designed and miniaturized using a silicon photomultiplier (SiPM) and a cerium-doped-gadolinium-aluminum-gallium-garnet (Ce:GAGG) scintillator, and an underwater wireless monitoring system was implemented by employing a remote Bluetooth communication module. An acrylic water tank and reference radiation sources ($^{137}Cs$, $^{90}Sr$) were used to evaluate the effectiveness of the monitoring sensor. The underwater monitoring sensor's detection response and efficiency for gamma rays and beta particles as well as the linearity of the response according to the gammaray intensity were verified through an evaluation. This evaluation is expected to contribute to the development of base technology for an underwater radiation-monitoring system.

CMOS 이미지 센서를 사용한 방사선 측정에 관한 연구 (A Study On Radiation Detection Using CMOS Image Sensor)

  • 이주현;이승호
    • 전기전자학회논문지
    • /
    • 제19권2호
    • /
    • pp.193-200
    • /
    • 2015
  • 본 논문에서는 CMOS 이미지 센서를 사용한 방사선 측정 알고리즘 및 장치의 구성을 제안한다. CMOS 이미지 센서를 사용한 방사선 측정 알고리즘은 CMOS 이미지 센서에 입사된 방사선 입자 판별 알고리즘과 CMOS 이미지 센서로 매초 수 십장의 이미지에 입사된 방사선 입자에 대한 픽셀 수의 누적 및 평균을 기준으로 하는 방사선 수치 측정 알고리즘을 사용한다. CMOS 이미지 센서에 입사된 방사선 입자 판별 알고리즘은 입사된 방사선 입자의 이미지를 R, G, B로 분할하고 각각의 이미지에 대해 명암 및 백그라운드와 입자를 구별할 수 있는 임계값 설정 조정을 통하여 측정한다. 방사선 수치 측정 알고리즘은 설정된 주기에 따른 CMOS 이미지 센서로 매초 수 십장의 이미지에 입사된 방사선 입자수를 누적 저장, 평균을 통하여 방사선 수치를 측정한다. 제안된 알고리즘의 검증을 위한 하드웨어 장치는 CMOS 이미지 센서 및 이미지 시그널 프로세서부, 제어부, 전원회로부, 디스플레이부 등으로 구성된다. 제안된 CMOS 이미지 센서를 사용한 방사선 측정에 관하여 실험한 결과는 다음과 같다. 첫 번째로 저가의 CMOS 이미지 센서를 사용하여 방사선 입자 판별 측정 실험을 통해 고가의 GM Tube의 측정 구간별 특성과 대체로 유사한 특성을 나타낼 수 있음을 확인할 수 있었다. 두 번째로 저가의 CMOS 이미지 센서로 방사선 수치 측정 실험을 통해 고가의 GM Tube가 나타내는 선형 특성과 대체로 유사한 특성을 나타냄을 확인할 수 있었다.

Si PIN Radiation Sensor with CMOS Readout Circuit

  • Kwon, Yu-Mi;Kang, Hee-Sung;Lee, Jung-Hee;Lee, Yong Soo
    • 센서학회지
    • /
    • 제23권2호
    • /
    • pp.73-81
    • /
    • 2014
  • Silicon PIN diode radiation sensors and CMOS readout circuits were designed and fabricated in this study. The PIN diodes were fabricated using a 380-${\mu}m$-thick 4-inch n+ Si (111) wafer containing a $2-k{\Omega}{\cdot}cm$ n- thin epitaxial layer. CMOS readout circuits employed the driving and signal processes in a radiation sensor were mixed with digital logic and analog input circuits. The primary functions of readout circuits are amplification of sensor signals and the generation of the alarm signals when radiation events occur. The radiation sensors and CMOS readout circuits were fabricated in the Institute of Semiconductor Fusion Technology (ISFT) semiconductor fabrication facilities located in Kyungpook National University. The performance of the readout circuit combined with the Si PIN diode sensor was demonstrated.

Recent Advances in Radiation-Hardened Sensor Readout Integrated Circuits

  • Um, Minseong;Ro, Duckhoon;Kang, Myounggon;Chang, Ik Joon;Lee, Hyung-Min
    • Journal of Semiconductor Engineering
    • /
    • 제1권3호
    • /
    • pp.81-87
    • /
    • 2020
  • An instrumentation amplifier (IA) and an analog-to-digital converter (ADC) are essential circuit blocks for accurate and robust sensor readout systems. This paper introduces recent advances in radiation-hardening by design (RHBD) techniques applied for the sensor readout integrated circuits (IC), e.g., the three-op-amp IA and the successive-approximation register (SAR) ADC, operating against total ionizing dose (TID) and singe event effect (SEE) in harsh radiation environments. The radiation-hardened IA utilized TID monitoring and adaptive reference control to compensate for transistor parameter variations due to radiation effects. The radiation-hardened SAR ADC adopts delay-based double-feedback flip-flops to prevent soft errors which flips the data bits. Radiation-hardened IA and ADC were verified through compact model simulation, and fabricated CMOS chips were measured in radiation facilities to confirm their radiation tolerance.

무기 섬광체를 이용한 플라스틱 광섬유 방사선 센서부 제작 및 특성평가 (Fabrication and characterization of plastic fiber-optic radiation sensor tips using inorganic scintillator material)

  • 황영묵;조동현;이봉수;조효성;김신
    • 센서학회지
    • /
    • 제14권4호
    • /
    • pp.244-249
    • /
    • 2005
  • In this study, radiation sensor tips are fabricated for remote sensing of X or gamma ray with inorganic scintillators and plastic optical fiber. The visible range of light from the inorganic scintillator that is generated by radiation source is guided by the plastic optical fiber and is measured by optical detector and power-meter. Two kinds of sensor tips are designed and fabricated such as film type and powder type. Many kinds of inorganic scintillators are used to fabricate both sensor tips, and the different wavelength of emitting lights from them are measured to determine the optimal inorganic scintillator which has maximum light output. As a radiation source X-ray generator and Ir-192 are selected to test a performance of sensor tip. It is expected that the fiber-optic radiation sensor is widely used in nuclear industry and medical applications due to its special characteristics such as good flexibility, easy in processing, long lengths and no interference to electro magnetic field.

Cholesteric Liquid Crystals as Multi-Purpose Sensor Materials

  • Lisetski, L.N.
    • Journal of Radiation Protection and Research
    • /
    • 제30권1호
    • /
    • pp.27-30
    • /
    • 2005
  • New possibilities are discussed for cholesteric liquid crystals (CLC) as sensor materials for detection of ionizing radiation, biologically active UV radiation, and the presence of hazardous vapors in atmosphere. A distinguishing property of CLC-based detectors is their 'bioequivalence', i.e., mechanisms of their response to external factors essentially imitate the corresponding mechanisms of biological tissues. Such detectors can ensure sufficiently high sensitivity to make feasible their use as alarm indicators or in biophysical studies. Specific examples ate given of sensor compositions and their response characteristics.

방사선 오염분포 영상화를 위한 방사선 센서의 탐지 범위 개선에 관한 연구 (Detection Range Improvement of Radiation Sensor for Radiation Contamination Distribution Imaging)

  • 송근영;황영관;이남호;나준희
    • 한국정보통신학회논문지
    • /
    • 제23권12호
    • /
    • pp.1535-1541
    • /
    • 2019
  • 방사선 사고 지역 및 제염이 필요한 지역에서의 안전하고 신속한 제염작업을 진행하기 위해서는 방사선 오염원에 대한 다양한 정보 획득이 필요하다. 특히 방사선원의 정확한 위치와 분포 정보의 파악은 신속한 후속 조치 및 오염원 제거를 위해 반드시 필요하며, 작업자의 방사선 피폭을 최소화할 수 있다. 방사선원의 위치와 분포 정보를 획득하기 위해서는 방사선 분포 탐지 장치를 사용한다. 방사선 분포 탐지 장치의 경우 일반적으로 탐지 센서 부가 단일 센서로 구성되며, 단일 센서의 물리적 한계로 인해 탐지 범위가 제한되는 문제점이 있다. 본 논문에서는 방사선 오염 분포 영상화 장치에 사용되는 단일 센서의 탐지 감도 제어를 위하여 보정 검출기를 적용하였으며, 이를 통해 제한적이었던 선량률 탐지 범위를 향상하였다. 또한 감마선 조사 시험을 통해 방사선 분포 탐지 범위의 개선을 확인하였다.

방사선 노출에 따른 3T APS 성능 감소와 몬테카를로 시뮬레이션을 통한 픽셀 내부 결함의 비교분석 (A Comparison between the Performance Degradation of 3T APS due to Radiation Exposure and the Expected Internal Damage via Monte-Carlo Simulation)

  • 김기윤;김명수;임경택;이은중;김찬규;박종환;조규성
    • 방사선산업학회지
    • /
    • 제9권1호
    • /
    • pp.1-7
    • /
    • 2015
  • The trend of x-ray image sensor has been evolved from an amorphous silicon sensor to a crystal silicon sensor. A crystal silicon X-ray sensor, meaning a X-ray CIS (CMOS image sensor), is consisted of three transistors (Trs), i.e., a Reset Transistor, a Source Follower and a Select Transistor, and a photodiode. They are highly sensitive to radiation exposure. As the frequency of exposure to radiation increases, the quality of the imaging device dramatically decreases. The most well known effects of a X-ray CIS due to the radiation damage are increments in the reset voltage and dark currents. In this study, a pixel array of a X-ray CIS was made of $20{\times}20pixels$ and this pixel array was exposed to a high radiation dose. The radiation source was Co-60 and the total radiation dose was increased from 1 to 9 kGy with a step of 1 kGy. We irradiated the small pixel array to get the increments data of the reset voltage and the dark currents. Also, we simulated the radiation effects of the pixel by MCNP (Monte Carlo N-Particle) simulation. From the comparison of actual data and simulation data, the most affected location could be determined and the cause of the increments of the reset voltage and dark current could be found.

A Noise Re-radiation Calibration Technique in Interferometric Synthetic Aperture Radiometer for Sub-Y-type Array at Ka-Band

  • Seo Seungwon;Kim Sunghyun;Choi Junho;Park Hyuk;Lee Hojin;Kim Yonghoon;Kang Gumsil
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2004년도 Proceedings of ISRS 2004
    • /
    • pp.577-580
    • /
    • 2004
  • To overcome with large size noise source distribution network design difficulty in interferometric radiometer system, especially for sub-Y-type array, a new on-board calibration technique using noise re-radiation is proposed in this paper. The suggested calibration technique is using noise re-radiation effect of center antenna after noise source injection from matched load. This approach is especially proper to sub-Y-type array interferometric synthetic aperture radiometer in mm-wave frequency band. Compared with noise injection network of a conventional synthetic aperture radiometer, the system mass, volume, and hardware complexity is reduced and cost-effective. Only one internal noise source, matched load, is used for injection using noise re-radiation technique a small set of sub-Y receiver channels is calibrated. Detailed calibration scenario is discussed and simulation results about noise re­radiation effect are presented.

  • PDF