The Analysis of the Collimator & Radiation Shield for the Radiation Sensor for the 3Dimension Radiation Detection (3차원 방사선 탐지장치용 검출센서의 차폐체 및 Collimator 구조 분석 연구)

  • Hwang, Young-Gwan;Lee, Nam-Ho;Park, Sumg-Hun;Jeong, Sang-Hun;Kim, Jong-Ryul;Choi, Myung-Jin
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.05a
    • /
    • pp.707-709
    • /
    • 2014
  • The radiation sources leaked from large-scale radiation leak accident like the Fukushima nuclear power plant accident or nuclear explosions can cause to the very large damage for us. So that the damage can be minimized, we have being developed a detector that can providing information about the location of the source to remove dangerous substances quickly than the conventional single detector. In this paper, we designed and implemented the radiation shield and the collimator for the development of the stereo radiation detector to detect contamination things using MCNP Simulation. And we analysed the test results of the radiation shield and collimator using the radiation source. The results of this paper will be used as the basis for improving the efficiency of the stereo radiation detector being studied currently.

  • PDF

A Source-Related Approach for Discussion on Using Radionuclide-Contaminated Materials in Post-accident Rehabilitation

  • Kazuji Miwa;Takeshi Iimoto
    • Journal of Radiation Protection and Research
    • /
    • v.48 no.2
    • /
    • pp.68-76
    • /
    • 2023
  • Background: In the process of discussion on the possibility of using radionuclide-contaminated soil and debris generated by radiation disasters, a strategy for the proper management of radiation exposure protection while considering the source of the contaminated materials is necessary. Materials and Methods: The radiological protection criteria that are likely to be applied to the source-related approach based on the International Commission on Radiological Protection recommendations and the International Atomic Energy Agency safety standards are summarized. We proposed five interpretations of radiation protection to contribute to the promotion of discussion on the possibility of using a part of low-level-radionuclide-contaminated soil and debris in the post-accident rehabilitation. Interpretations I to III are based on the idea of "using a reference level to protect the public in post-accident rehabilitation," whereas IV and V are based on the idea of "using the dose constraint to protect the public in the post-accident rehabilitation when the sources are handled in a planned activity." The former idea is subdivided into three based on the definition of the source, which is managed by the reference level, and the latter idea is divided into two depending on whether or not additional dose from using contaminated materials is deemed acceptable. Results and Discussion: To confirm the applicability of the five interpretations presented, we suggested the concrete values of protection criteria via two feasible cases. In this case study, we proposed radiation protection by the dose constraint based on the Interpretation IV and chose 1 mSv/yr for the public and 20 mSv/yr for workers dealing with radionuclide-contaminated materials. Conclusion: We concretely and systematically demonstrated how the concept of radiation protection can be applied to the process of discussion on the possibility of using radionuclide-contaminated materials within the framework of an international system of protection. This study's findings can provide necessary information to discuss the possibility of using radionuclide-contaminated materials as an alternative option for recovery and reconstruction after a radiation disaster from the viewpoint of radiation protection.

Development of Three-Dimensional Gamma-ray Camera (방사선원 3차원 위치탐지를 위한 방사선 영상장치 개발)

  • Lee, Nam-Ho;Hwang, Young-Gwan;Park, Soon-Yong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.2
    • /
    • pp.486-492
    • /
    • 2015
  • Radiation source imaging system is essential for protecting of radiation leakage accidents and minimizing damages from the radioactive materials, and is expected to play an important role in the nuclear plant decommissioning area. In this study, the stereoscopic camera principle was applied to develop a new radiation imaging device technology that can extract the radiation three-dimensional position information. This radiation three-dimensional imaging device (K3-RIS) was designed as a compact structure consisting of a radiation sensor, a CCD camera, and a pan-tilt only. It features the acquisition of stereoscopic radiation images by position change control, high-resolution detection by continuous scan mode control, and stereoscopic image signal processing. The performance analysis test of K3-RIS was conducted for a gamma-ray source(Cs-137) in radiation calibration facility. The test result showed that a performance error with less than 3% regardless of distances of the objects.

Development of High-Sensitivity Detection Sensor and Module for Spatial Distribution Measurement of Multi Gamma Sources (다종 감마선 공간분포 측정을 위한 고감도 검출센서 및 탐지모듈 개발)

  • Hwang, Young-Gwan;Lee, Nam-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.10a
    • /
    • pp.705-707
    • /
    • 2017
  • Stereo-based spatial radiation detection devices can obtain not only spatial distribution information about the radiation source but also distance information from the detection device to the source. And it provides more efficient information on the source than the existing radiation imaging device. In order to provide high-speed information on the spectrum and type of gamma-ray source, a high-sensitivity detection sensor with high sensitivity is required, and a technique capable of solving the saturation phenomenon at a high dose is needed. In this paper, we constructed a high sensitivity sensor for the measurement of multiple gamma - ray spatial distributions using improved function of detection module to solve saturation to high dose and conducted research to increase the scope of a single detector. The result of this paper improves the performance of gamma ray.

  • PDF

A Study on the Source Mechanism of Micro-crack by Radiation Pattern (방사형식에 의한 미소균열의 파괴메커니즘에 관한 연구)

  • Lee Sang-Eun
    • The Journal of Engineering Geology
    • /
    • v.16 no.2 s.48
    • /
    • pp.179-187
    • /
    • 2006
  • Two specimens of mortar containing artificial slit and Geochang granite containing the straight notch were selected to be used in this research. Source mechanism of micro-crack by radiation pattern based on dislocation the-ory was estimated by the first motion of longitudinal wave and spatial distribution between the location of transducers for monitoring acoustic emission and source coordinates determined by the application of the least square method. Result of analysis showed that the orientation of dislocation surfaces due to shear dislocation and tensile dislocation squares considerably with crack direction visually observed. The ultimate goal of this study is to provide fundamental information for source mechanism of micro-crack within materials.

Awareness Patterns Regarding Radiation Safety Management in Fields Related to Radiation Safety Regulations: Focusing on Companies that Must Report Radiation Sources

  • Eunok Han;Yoonseok Choi
    • Journal of Radiation Protection and Research
    • /
    • v.49 no.1
    • /
    • pp.19-28
    • /
    • 2024
  • Background: This study aims to analyze radiation safety management and regulatory perceptions, focusing on companies that must report radiation sources. The intent is to reduce the gap between regulation measures and addressing real concerns while improving practical safety management measures and regulations for all stakeholders. Materials and Methods: Radiation safety officers at a total of 244 reporting companies using radiation generators (79.8%) and sealed radioisotopes (15.1%) were surveyed using a questionnaire. Results and Discussion: The perception that regulation is stronger than the actual risk of the radiation source used was 3.47 points (out of 5 points), indicating a score above average. The most important factors and considerations were education and training (48%) as a human factor, safety devices of the radiation source (71.3%) as a hazardous material factor, the use of radiation (50.8%) as an organizational environment, and the radiation effect of nearby facilities (67.2%) as a physical environment. Radiation safety management educational experience (F= 5.030, p< 0.01), the group with high subjective knowledge (t= 6.017, p< 0.001), and the group with high objective knowledge (t= 1.989, p< 0.05) was found to be better at radiation safety management. Conclusion: It is necessary to standardize the educational experience regarding radiation safety management because each staff member has individual differences in educational experience. It is necessary to provide more information on how to solve radiation accidents via educational content. Applying radiation safety regulations based on the factors that significantly affect radiation safety management shown in this survey will help improve safety.

The Study for the analysis of the detection efficiency and the design of the radiation detector's collimator using MCNP (MCNP 기반 스테레오 방사선 검출기 콜리메이터 설계 및 선량검출효율 분석연구)

  • Hwang, Young-Gwan;Lee, Nam-Ho;Kang, Gi-Byong;Park, Jong-Won
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.1017-1019
    • /
    • 2013
  • The radiation sources leaked from large-scale radiation leak accident like the Hukushima nuclear power plant accident or nuclear explosions can cause to the very large damage for us. So that the damage can be minimized, we have being developed a detector that can providing information about the location of the source to remove dangerous substances quickly than the conventional single detector. In this paper, we designed the shielding and collimator for the development of the Stereo Radiation detector in order to detect contaminants using MCNP Code. And we analyzed the results that is detected from the discretionary position of the radiation source. The results of this paper will be used as the basis for designing efficient structure for the radiation detectors.

  • PDF

The Study Image Aquisition System for Radiation Source Using the Stereo Gamma-ray Detector (스테레오 감마선 탐지장치를 이용한 감마선원 분포측정 시스템에 관한 연구)

  • Hwang, Young-Gwan;Lee, Nam-Ho;Lee, Seung-Min
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.4
    • /
    • pp.197-203
    • /
    • 2015
  • Nuclear power plant has increased continuously for power production in all over the world and the interest about nuclear accident and the dismantling of aging nuclear power plant has been a growing. The leaked radioactive source that is generated by radiation accidents must detect and remove to minimized the damage as soon as possible. Gamma-ray detection system that have been developed until now cannot provide the precise position of radioactive sources because they detect and imaging the position of radiation sources in just two dimensions. In this paper, stereo gamma ray detection system has developed and the algorithm for calculation of the distance has implemented to be able to measure the distribution of the leakage gamma ray source for the system. Stereo camera calibration for distance detection was conducted with the correction pattern and LED light and we carried out performance test of the system for the LED light source and a gamma ray source. In both experiments the results of the performance test, it was confirmed to have a 5% error. The results of this paper is used as a material for the development of gamma-ray imaging device.

A Study on the Solar Radiation Estimation of 16 Areas in Korea Using Cloud Cover (운량을 고려한 국내 16개 지역의 일사량 예측방법)

  • Jo, Dok-Ki;Kang, Young-Heack
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.4
    • /
    • pp.15-21
    • /
    • 2010
  • Radiation data are the best source of information for estimating average incident radiation. Lacking this or data from nearby locations of similar climate, it is possible to use empirical relation ships to estimate radiation from days of cloudiness. It is necessary to estimate the regression coefficients in order to predict the daily global radiation on a horizontal surface. There fore many different equations have proposed to evaluate them for certain areas. In this work a new correlation has been made to predict the solar radiation for 16 different areas over Korea by estimating the regression coefficients taking into account cloud cover. Particularly, the straight line regression model proposed shows reliable results for estimating the global radiation on a horizontal surface with monthly average deviation of -0.26 to +0.53% and each station annual average deviation of -1.61 to +1.7% from measured values.

Variation of Illumination Performance with Source Size and Tolerance Characteristics of Freeform LED Lenses (LED 광원 크기에 따른 자유 형상 렌즈의 조명 성능 변화와 공차 특성)

  • Yang, Jae-Suk;Kim, Dae-Chan;O, Beom-Hoan;Park, Se-Geun;You, Il Hyun;Lee, Seung Gol
    • Korean Journal of Optics and Photonics
    • /
    • v.24 no.1
    • /
    • pp.29-38
    • /
    • 2013
  • In this paper, the illumination performances of three freeform lenses optimally designed for a point source were investigated for several LEDs with different source sizes, and also the tolerance characteristics of the lenses were analyzed. For comparison, two lenses with different sizes were designed with a divergent illumination model, and the last one was done with an overlapped illumination model. As the LED source size increased, the illuminance uniformity decreased more strongly, and the influence of a source misalignment on illumination performance became insignificant. However, the variation of LED radiation characteristics had strong effect on the illumination performance, irrespective of LED source size. Even though the lens based on a divergent illumination model showed superior performance compared to the lens based on an overlapped illumination model, the latter was less sensitive to the variation of LED radiation characteristics.