• Title/Summary/Keyword: Radiation emergency

Search Result 223, Processing Time 0.021 seconds

Heat Transfer Analysis and Experiments of Reinforced Concrete Slabs Using Galerkin Finite Element Method (Galerkin 유한요소법을 이용한 철근콘크리트 슬래브의 열전달해석 및 실험)

  • Han, Byung-Chan;Kim, Yun-Yong;Kwon, Young-Jin;Cho, Chang-Geun
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.5
    • /
    • pp.567-575
    • /
    • 2012
  • A research was conducted to develop a 2-D nonlinear Galerkin finite element analysis of reinforced concrete structures subjected to high temperature with experiments. Algorithms for calculating the closed-form element stiffness for a triangular element with a fully populated material conductance are developed. The validity of the numerical model used in the program is established by comparing the prediction from the computer program with results from full-scale fire resistance tests. Details of fire resistance experiments carried out on reinforced concrete slabs, together with results, are presented. The results obtained from experimental test indicated in that the proposed numerical model and the implemented codes are accurate and reliable. The changes in thermal parameters are discussed from the point of view of changes of structure and chemical composition due to the high temperature exposure. The proposed numerical model takes into account time-varying thermal loads, convection and radiation affected heat fluctuation, and temperature-dependent material properties. Although, this study considered standard fire scenario for reinforced concrete slabs, other time versus temperature relationship can be easily incorporated.

Automatic On-Chip Glitch-Free Backup Clock Changing Method for MCU Clock Failure Protection in Unsafe I/O Pin Noisy Environment (안전하지 않은 I/O핀 노이즈 환경에서 MCU 클럭 보호를 위한 자동 온칩 글리치 프리 백업 클럭 변환 기법)

  • An, Joonghyun;Youn, Jiae;Cho, Jeonghun;Park, Daejin
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.12
    • /
    • pp.99-108
    • /
    • 2015
  • The embedded microcontroller which is operated by the logic gates synchronized on the clock pulse, is gradually used as main controller of mission-critical systems. Severe electrical situations such as high voltage/frequency surge may cause malfunctioning of the clock source. The tolerant system operation is required against the various external electric noise and means the robust design technique is becoming more important issue in system clock failure problems. In this paper, we propose on-chip backup clock change architecture for the automatic clock failure detection. For the this, we adopt the edge detector, noise canceller logic and glitch-free clock changer circuit. The implemented edge detector unit detects the abnormal low-frequency of the clock source and the delay chain circuit of the clock pulse by the noise canceller can cancel out the glitch clock. The externally invalid clock source by detecting the emergency status will be switched to back-up clock source by glitch-free clock changer circuit. The proposed circuits are evaluated by Verilog simulation and the fabricated IC is validated by using test equipment electrical field radiation noise

A Study on the Performance Evaluation of Standard Gamma Irradiation System Using Monte Carlo Code (몬테카를로 코드를 활용한 표준 감마선 조사장치의 성능평가에 관한 연구)

  • Park, Won-Seok;Heo, Seung-Uk;Kim, Jang-Oh;Min, Byung-In
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.2
    • /
    • pp.179-184
    • /
    • 2018
  • In this study, we compared the measured values of the effective beam size of standard gamma irradiator with the simulation results to provide a useful means to the effective beam area determination. Results of the simulation and measured using ion chamber was distributed in a relative error of 4.5 ~ 7.3% of the case of air kerma rate. The size of the effective beam area is when the simulation was implemented in the horizontal direction 27cm, 21.6cm vertical direction, the measured result using a film was obtained similar results with the horizontal direction 26.5cm, 21.9cm vertical direction. The relative error in the horizontal direction is 1.85% and 1.38% vertical effective beam area was also similarly distributed around the field gamma rays. As a result of the study, it was confirmed that the effectiveness of the simulation was sufficient for the gamma irradiation system. In particular, it is small relative errors in the effective beam size than the air kerma rate is considered to be due to the size of the beam is determined by geometric factors rather than the capacity of the standard source. A further study is needed to improve the reliability of the photon energy distribution diagram using simulation.

A Case of Coronary-Pulmonary Artery Fistula (관상동맥-폐동맥 누공 1예)

  • Lee, Kyung Hae;Wang, Joon Kwang;Shin, Sung Joon;Kim, Mi Ok;Kim, Tae Hyung;Son, Jang Won;Yun, Ho Ju;Shin, Dong Ho;Park, Sung Soo;Kim, Kyung Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.56 no.4
    • /
    • pp.420-425
    • /
    • 2004
  • Fistula between coronary artery and pulmonary artery is a type of coronary artery anomalies. It can cause atypical chest pain and fatigue, angina pectoris, endocarditis, finally myocardial steal can result in heart failure and myocardial infarction. But only 0.1-0.2% of coronary angiographic studies reveal the communications between coronary artery and other spaces. (heart chamber, pulmonary artery etc.) It is frequently congenital, but acquired types are increasing because chest and heart manipulations such as opertion of tetralogy of Fallot, endomyocardial biopsy, radiation therapy, or penetrating blunt trauma are increasing. There are reports about repair of fistula using thrombogenic tips, coil embolization and surgical intervention. We report a connection between coronary artery and pulmonary artery in 79 years old female. She was 30 pack-years smoker and suffered from dyspnea several years with chronic obstructive pulmonary disease. She presented with atypical chest pain and palpitation after admission. Electrocardiography showed ST-T wave abnormality. Emergency coronary angiography and chest CT scan revealed coronary-pulmonary artery fistula. Transcatheter embolization was performed and she was relieved from discomforts.

MDA Assessment of NaI(Tl), LaBr3(Ce), and CeBr3 Detectors for Freshly Deposited Radionuclides on the Soil (지표면 침적 방사성핵종에 대한 NaI(Tl), LaBr3(Ce) 및 CeBr3 검출기의 MDA 비교 평가)

  • Lee, Jun-Ho;Kim, Bong-Gi;Lee, Dong Myung;Byun, Jong-In
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.17 no.3
    • /
    • pp.321-328
    • /
    • 2019
  • The detection performances of the NaI(Tl), $LaBr_3$(Ce) and $CeBr_3$ scintillation detectors, which can be used to rapidly evaluate the major artificial radionuclides deposited on the soil surface in a nuclear accident or radiological emergency, were compared. Detection performance was assessed by calculating the minimum detectable activity (MDA). The detection efficiency of each detector for artificial radionuclides was semi-empirically determined using mathematical modelling and point-like sources having certified radioactivity. The background gamma-ray energy spectrum for MDA evaluation was obtained from relatively wide and flat grassland, and the MDA values of each detector for the major artificial radionuclides that could be released in nuclear accidents were calculated. As a result, the relative MDA values of each detector regarding surface deposition distribution at normal environmental radiation level were evaluated as high in the order of the NaI(Tl), $LaBr_3$(Ce), and $CeBr_3$ detectors. These results were compared based on each detector's intrinsic and measurement environment background, detection efficiency, and energy resolution for the gamma-ray energy region of the radionuclide of interest.

Evaluation on Medical Application of Survey meters in Convergence Perspective for the Efficient Disaster Responses in the Massive Radiological Disasters: A Simulation Study of Externally Contaminated Patients Using Two Representative type of Survey-Meters (융합적 관점에서 본 대량방사선 재난에서 효율적 재난반응을 위한 오염감시기의 의학적 적용에 대한 평가: 대표적 두가지 오염감시기를 이용한 방사선외부오염환자 시뮬레이션 연구)

  • Kim, Chu Hyun
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.3
    • /
    • pp.77-83
    • /
    • 2021
  • The purpose of the study is to evaluate the effect on medical application and convergence for the efficient disaster responses in the massive radiological events by comparison of two types of survey-meters(hand held survey-meter and transportable portal monitor). In the simulated radiation disaster drill, twelve participants randomly wore a personal protective equipments (PPE) with twelve check source. We measured participants to detect five real radioactive sources of the twelve check sources, using two types of survey meters. The primary outcome was the measuring time. The secondary outcome was the sensitivity and specificity of the detection of the real radioactive source. The average time by the hand held survey meter was 231.9 ± 116.6 seconds, and the time by transportable portal monitor was statistically shorter 8.690 ± 1.667 seconds. There was no difference in the sensitivity and specificity between two survey meters. The transportable portal monitor survey meter was considered to have medical application and play an important role in radiological disasters.

SNIPE Mission for Space Weather Research (우주날씨 관측을 위한 큐브위성 도요샛 임무)

  • Lee, Jaejin;Soh, Jongdae;Park, Jaehung;Yang, Tae-Yong;Song, Ho Sub;Hwang, Junga;Kwak, Young-Sil;Park, Won-Kee
    • Journal of Space Technology and Applications
    • /
    • v.2 no.2
    • /
    • pp.104-120
    • /
    • 2022
  • The Small Scale magNetospheric and Ionospheric Plasma Experiment (SNIPE)'s scientific goal is to observe spatial and temporal variations of the micro-scale plasma structures on the topside ionosphere. The four 6U CubeSats (~10 kg) will be launched into a polar orbit at ~500 km. The distances of each satellite will be controlled from 10 km to more than ~1,000 km by the formation flying algorithm. The SNIPE mission is equipped with identical scientific instruments, Solid-State Telescopes(SST), Magnetometers(Mag), and Langmuir Probes(LP). All the payloads have a high temporal resolution (sampling rates of about 10 Hz). Iridium communication modules provide an opportunity to upload emergency commands to change operational modes when geomagnetic storms occur. SNIPE's observations of the dimensions, occurrence rates, amplitudes, and spatiotemporal evolution of polar cap patches, field-aligned currents (FAC), radiation belt microbursts, and equatorial and mid-latitude plasma blobs and bubbles will determine their significance to the solar wind-magnetosphere-ionosphere interaction and quantify their impact on space weather. The formation flying CubeSat constellation, the SNIPE mission, will be launched by Soyuz-2 at Baikonur Cosmodrome in 2023.

Shielding Performance of PLA and Tungsten Mixture using Research Extruder (연구용 압출기를 활용한 PLA와 텅스텐 혼합물의 차폐 성능)

  • Do-Seong Kim;Tae-Hyung Kim;Myeong-Seong Yoon;Sang-Hyun Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.557-564
    • /
    • 2023
  • In this study, 3D printing technology was used to compensate for the shortcomings of the use of lead, which has proven to have excellent shielding performance, and to control unnecessary human exposure. 3D printers can implement three-dimensional shapes and can immediately apply individual ideas, which has great advantages in maintaining technology supplementation while reducing the cost and duration of prototyping. Among the various special 3D printers, the FDM method was adopted, and the filament used for output was manufactured using a research extruder by mixing two materials, PLA (Poly-Lactic-Acid) and tungsten. The purpose was to verify the validity through dose evaluation and to provide basic information on the production of chapezones of various materials. The mixed filament was implemented as a morphological shield. Filaments made of a research extruder by mixing PLA and tungsten were divided into 10 %, 20 %, 30 %, 40 %, and 50 % according to the tungsten content ratio. Through the process of 3D Modeling, STL File storage, G-code generation, and output, 10 cm × 10 cm × 0.5 cm was manufactured, respectively, and dose and shielding ability were evaluated under the conditions of tube voltages of 60 kVp, 80 kVp, 100 kVp, 120 kVp, and tube currents of 20 mAs and 40 mAs.

Evaluation of Applicability of Customized Bolus According to 3D Printer Material Characteristics (3D 프린터 소재 특성에 따른 맞춤형 볼루스의 적용성 평가)

  • Kyung-Tae Kwon;Hui-Min Jang;Myeong-Seong Yoon
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.7
    • /
    • pp.1091-1097
    • /
    • 2023
  • Bolus is used in radiation therapy to prescribe an even dose to the tumor when the skin surface is inclined or has irregularities. At this time, the dose to the skin surface increases. Due to the patient's unique body structure and irregular skin, voids may occur between the bolus and the skin, which may reduce the accuracy of treatment. Therefore, in this study, the existing bolus and the self-produced bolus through 3D printing were applied to the nasal area, and the difference between the surface dose after treatment plan and the dose directly measured with an Optically Stimulated luminescence(OSL) dosimeter was compared to the existing bolus. The bolus rate was 97%, PLA 100.33%, ePETELA 75A 100.53%, and ePETELA 85A 100.36%. It was confirmed that there was little error in the measurement values and treatment plan values for each material. In addition, compared to when applying a conventional bolus, a difference of -3% to +0.5% for a 3D printed bolus can be confirmed, so a customized bolus produced through 3D printing can complement the shortcomings of the existing bolus. It is believed that there will be.

Estimation of Uranium Particle Concentration in the Korean Peninsula Caused by North Korea's Uranium Enrichment Facility (북한 우라늄 농축시설로 인한 한반도에서의 공기중 우라늄 입자 농도 예측)

  • Kwak, Sung-Woo;Kang, Han-Byeol;Shin, Jung-Ki;Lee, Junghyun
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.3
    • /
    • pp.127-133
    • /
    • 2014
  • North Korea's uranium enrichment facility is a matter of international concern. It is of particular alarming to South Korea with regard to the security and safety of the country. This situation requires continuous monitoring of the DPRK and emergency preparedness on the part of the ROK. To assess the detectability of an undeclared uranium enrichment plant in North Korea, uranium concentrations in the air at both a short and a long distance from the enrichment facility were estimated. $UF_6$ source terms were determined by using existing information on North Korean facility and data from the operation experience of enrichment plants from other countries. Using the calculated source terms, two atmospheric dispersion models (Gaussian Plume Model and HYSPLIT models) and meteorological data were used to estimate the uranium particle concentrations from the Yongbyon enrichment facility. A maximum uranium concentration and its location are dependent upon the meteorological conditions and the height of the UF6 release point. This study showed that the maximum uranium concentration around the enrichment facility was about $1.0{\times}10^{-7}g{\cdot}m^{-3}$. The location of the maximum concentration was within about 0.4 km of the facility. It has been assumed that the uranium sample of about a few micrograms (${\mu}g$) could be obtained; and that few micrograms of uranium can be easily measured with current measurement instruments. On the contrary, a uranium concentration at a distance of more than 100 kilometers from the enrichment facility was estimated to be about $1.0{\times}10^{-13}{\sim}1.0{\times}10^{-15}g{\cdot}m^{-3}$, which is less than back-ground level. Therefore, based on the results of our paper, an air sample taken within the vicinity of the Yongbyon enrichment facility could be used to determine as to whether or not North Korea is carrying out an undeclared nuclear program. However, the air samples taken at a longer distance of a few hundred kilometers would prove difficult in detecting a clandestine nuclear activities.