• Title/Summary/Keyword: Radiation dosage

Search Result 160, Processing Time 0.028 seconds

Radiation absorbed doses of cone beam computed tomography (Cone beam형 전산화단층촬영에 의한 흡수선량)

  • Lee, Eui-Tae;Kim, Gyu-Tae;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • v.37 no.2
    • /
    • pp.87-92
    • /
    • 2007
  • Purpose: To measure the absorbed doses of cone beam computed tomography (CBCT), which is recently being more frequently used, and to compare them with those of panoramic radiography. Materials and Methods: To measure the absorbed doses of CBCT ($PSR-9000N^{TM}$, Asahi Roentgen Ind. Co., Japan), we placed TLD chips on the skin regions above the parotid and thyroid glands, and on the dorsum of tongue in a dental head phantom. We used two image acquisition modes of the Dental and Panoramic modes of CBCT, which differed in the field of view. Also, panoramic radiographs (Auto IIIN, Asahi Roentgen Ind. Co., Japan) were taken to compare with the absorbed doses of CBCT. Result: In the Dental mode of CBCT, the absorbed doses of the parotid gland, dorsum of tongue, and thyroid gland were 3.53, 3.13, and 0.36 mGy, respectively. In the Panoramic mode of CBCT, they were 9.57, 9.15, and 0.85 mGy, respectively. The panoramic mode showed higher absorbed doses than those of the Dental mode. In the panoramic radiography, the absorbed doses of the parotid gland, dorsum of tongue, and thyroid gland were 1.21, 1.19, and 0.16 mGy, respectively. And they were about 1/3 of the Dental mode and 1/9 of the Panoramic mode of CBCT. Conclusion: Absorbed doses of CBCT are higher than those of panoramic radiography, and dependent upon the field of view.

  • PDF

Determination of Seedling Sensitivity and Selection of Morphological Mutants by Treatments of Gamma-Ray and EMS in Rapeseed and Leaf Mustard (감마선 및 EMS처리에 의한 유채(Brassica napus L.)와 갓(Brassica juncea L.)의 유묘 감수성 평가 및 형태적 변이체 선발)

  • Kang, Eun-Seon;Kim, Jun-Su;Eun, Jong-Seon
    • Journal of Radiation Industry
    • /
    • v.8 no.2
    • /
    • pp.111-121
    • /
    • 2014
  • This study was aimed to select useful mutants of rapeseed (Brassica napus L.) and leaf mustard (Brassica juncea L.), the seeds of three lines S-14, S-27, and S-28 were treated with gamma-ray and EMS. The optimum ranges of gamma-ray dose and EMS concentration to enlarge the characteristic morphological variations were also separately investigated. The survival rates of S-28 only linearly decreased with increasing the gamma-ray dose. The overall growth parameters decreased of gamma-ray dose in all three lines of S-14, S-27, and S-28. The reduction dosage 50 of gamma-ray was identified as 1,200 Gy for S-14 leaf mustard, while those of S-27 and S-28 rapeseed lines were appeared as same 1,000 Gy. The emergence rates of S-14 and S-27 showed no significant differences by EMS treatment, while the growth of all three lines were significantly decreased. The reduction concentration 50 in S-14 could not be determined, demonstrating that this leaf mustard line is presumably insensitive to mutagenic EMS, while those in S-27 and S-28 were identified as 3.0 and 2.5%, respectively, showing that these rapeseed lines possess higher sensitivity to EMS than S-14. Various morphological characteristics of $M_1$ generation obtained from mutagen treatment were elaborately investigated for further maintenance of $M_2$ generation. In $M_2$ generation variants showing short stem, yellow color in seed coat, chlorophyll deficiencies in leaf or pod, abnormal flower color were selected as potentially useful mutants for breeding.

Characterization of a conjugated polysuccinimide-carboplatin compound

  • Sun Young Lee;Chang Hoon Chae;Miklos Zrinyi;Xiangguo Che;Je Yong Choi;Dong-Hyu Cho
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.27 no.1
    • /
    • pp.31-38
    • /
    • 2023
  • Carboplatin, an advanced anticancer drug with excellent efficacy against ovarian cancer, was developed to alleviate the side effects that often occur with cisplatin and other platinum-based compounds. Our study reports the in vitro characteristics, viability, and activity of cells expressing the inducible nitric oxide synthase (iNOS) gene after carboplatin was conjugated with polysuccinimide (PSI) and administered in combination with other widely used anticancer drugs. PSI, which has promising properties as a drug delivery material, could provide a platform for prolonging carboplatin release, regulating its dosage, and improving its side effects. The iNOS gene has been shown to play an important role in both cancer cell survival and inhibition. Herein, we synthesized a PSI-carboplatin conjugate to create a modified anticancer agent and confirmed its successful conjugation. To ensure its solubility in water, we further modified the structure of the PSI-carboplatin conjugate with 2-aminoethanol groups. To validate its biological characteristics, the ovarian cancer cell line SKOV-3 and normal ovarian Chinese hamster ovary cells were treated with the PSI-carboplatin conjugate alone and in combination with paclitaxel and topotecan, both of which are used in conventional chemotherapy. Notably, PSI-carboplatin conjugation can be used to predict changes in the genes involved in cancer growth and inhibition. In conclusion, combination treatment with the newly synthesized polymer-carboplatin conjugate and paclitaxel displayed anticancer activity against ovarian cancer cells but was not toxic to normal ovarian cancer cells, resulting in the development of an effective candidate anticancer drug without severe side effects.

A Study on Dose Reduction in Infant Skull Radiography (유아 두개골 방사선촬영에서 피폭선량 감쇄에 관한 연구)

  • Ahn, Byoung-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.5
    • /
    • pp.387-392
    • /
    • 2017
  • When an infant has visited a hospital due to skull fracture, the rupture of a blood vessel, or skin wounds on the head resulted from an incident, accident, traffic accident, or disease, he/she becomes to undergo anterior/posterior and lateral skull imaging, which is a head test at the department of radiology. In the head test, if the adult skull imaging grid is applied to the imaging, the secondary radiation will be removed to enhance the contrast of the image. However, among the radiation exposure conditions, the tube voltage should be enhanced by 8~10 kVp leading to an increase in the patient exposure. The present study was conducted under assumption that if the same images can be obtained from infant skull imaging without using the skull imaging grid, the exposure dose will be reduced and the artifacts due to grid cut off can be prevented. The researcher measured the radiation dosage using a radiation meter and conducted the subjective evaluation (ROC, receiver operating characteristic) among medical image evaluation methods. Based on the results, when the images were taken without using the grid, the exposure dose was reduced by 0.019 mGy in the anterior/posterior imaging and by 0.02 mGy in the lateral imaging and the image evaluation score was higher by 4 points. In conclusion, if the images of the skulls of infants that visited the hospital are taken with out using the grid, the exposure dose can be reduced, the image artifacts due to grid cut off can be prevented, and the lifespan of the X-ray tube will be extended.

The Radioprotection Effect of Aronia on Livers of Laboratory Rats Radiated to 6 MV X-ray of Linear Accelerator (선형가속기 6 MV X선에 조사된 흰쥐의 간에서 아로니아의 방사선 방호효과)

  • Lee, Jun-Haeng
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.2
    • /
    • pp.97-104
    • /
    • 2020
  • This aimed at figuring out if there were the radioprotection effects of aronia on livers of laboratory rats radiated through serum test. For the objects of animal testing, one group consists of five male laboratory rats (weight 200~250 g), and the groups were set as follows: Group 1, normal; Group 2, 5 Gy radiated control group; and Group 3, 5 Gy radiated experiment group with aronia. Group 1(A) was prescribed with ordinary meal without radiation while the control group, Group 2(B) was prescribed with ordinary meal and radiation, and the experiment group, Group 3(C) was orally prescribed with aronia (daily oral dosage: 100 mg/kg/day) diluted with distilled water at the amount of 50 mg/kg/day twice a week, using oral zonde needle for rats for 14 days before being radiated, and then, radiation were made on them. For the study, using Linac (Linear Accelerator) 6 MV X-ray therapy device, rats were irradiated on their whole bodies once, and their blood was sampled for conducting five blood serum tests with regard to liver. For statistical analysis, ANOVA test was conducted. In conclusion, as a result of the analysis, it seemed that there were no the radioprotection effects of aronia on liver. However, it was confirmed statistically that ALB (P>0.05) showed no significance and that TP (P<0.05) showed significant differences. It is expected that there should be more tests in future.

lonizing Radiation Hormesis in Crops (저선량 전리방사선에 의한 작물의 활성증진)

  • Kim, Jae-Sung;Lee, Young-Bok
    • Korean Journal of Environmental Agriculture
    • /
    • v.17 no.1
    • /
    • pp.76-83
    • /
    • 1998
  • The most remarkable aspect in the hormesis law is that dose of harmful agents can produce effect that are diametrically opposite to the effect found with high doses of the same agent. Minute quantities of a harmful agent bring about very small change in the organism and control mechanisms appear to subjugate normal processes to place the organism in a state of albert and repair. The stimulated organism in more responsive to changes in environmental factors than it did before being alerted. Routine functions, including repair and defense, have priority for available energy and matetial. The alerted organism utilizes nutrients more efficiently, grows faster, shows improved defense, and lives longer. Accelerated germination, sprouting, growth, development, blooming and ripening, and increased crop yield and resistance to disease are found in plants. Another concept supported by the data in that low doses of ionizing radiation provide increased resistance to subsequent high doses of radiation. The hormesis varies with subject plant, variety, state of seed, environmental and cultural conditions, physiologic function measured, dose rate and total exposure. The results of hormesis are less consistently found, probably due to the great number of uncontrolled variables in the experiments. The general dosage for radiation homlesis in about 100 (10 to 1,000) times ambient or 100 (10 to 1,000) times less than a definitely harmful dose, but these must be modified to the occasion. Although little is known about most mechanisms of homzesis reaction, overcompensation of repair mechanism is offered as one mechanism.

  • PDF

Chest-wall Surface Dose During Post-mastectomy Radiation Therapy, with and without Nonmagnetic Bolus: A Phantom Study

  • Choi, Cheon Woong;Hong, Joo Wan;Park, Cheol Soo;Ahn, Jae Ouk
    • Journal of Magnetics
    • /
    • v.21 no.2
    • /
    • pp.293-297
    • /
    • 2016
  • For mastectomy patients, sufficient doses of radiation should be delivered to the surface of the chest wall to prevent recurrence. A bolus is used to increase the surface dose on the chest wall, whereby the surface dose is confirmed with the use of a virtual bolus during the computerized treatment-planning process. The purpose of this study is an examination of the difference between the dose of the computerized treatment plan and the dose that is measured on the bolus. Part of the left breast of an Anderson Rando phantom was removed, followed by the attainment of computed tomography (CT) images that were used as the basis for computerized treatment plans that were established with no bolus, a 3 mm-thick bolus, a 5 mm-thick bolus, and a 10 mm-thick bolus. For the computerized treatment plan, a prescribed dose regimen was dispensed daily and planning target volume (PTV) coverage was applied according to the RTOG 1304 guidelines. Using each of the established computerized treatment plans, chest-wall doses of 5 points were measured; this chest-wall dose was used as the standard for the analysis of this study, while the level of significance was set at P < 0.05. The measurement of the chest-wall dose with no bolus is 1.6 % to 10.3 % higher, and the differences of the minimum average and the maximum average of the five measurement points are -13.8 and -1.9, respectively (P < 0.05); however, when the bolus was used, the dosage was measured as 3.7 % to 9.2 % lower, and the differences of the minimum average and the maximum average are 7.4 and 9.0, -1.2 and 17.4, and 8.1 and 19.8 for 3 mm, 5 mm, and 10 mm, respectively (P < 0.05). As the thickness of the bolus is increased, the differences of the average surface dose are further increased. There are a variety of factors that affect the surface dose on the chest wall during post-mastectomy radiation therapy, for which verification is required; in particular, a consideration of the appropriate thickness and the number of uses when a bolus is used, and which has the greatest effect on the surface dose on the chest wall, is considered necessary.

Size-Specific Dose Estimation In the Korean Lung Cancer Screening Project: Does a 32-cm Diameter Phantom Represent a Standard-Sized Patient in Korean Population?

  • Kim, Eun Young;Kim, Tae Jung;Goo, Jin Mo;Kim, Hyae Young;Lee, Ji Won;Lee, Soojung;Lim, Jun-tae;Kim, Yeol
    • Korean Journal of Radiology
    • /
    • v.19 no.6
    • /
    • pp.1179-1186
    • /
    • 2018
  • Objective: The purposes of this study were to evaluate size-specific dose estimate (SSDE) of low-dose CT (LDCT) in the Korean Lung Cancer Screening (K-LUCAS) project and to determine whether CT protocols from Western countries are appropriate for lung cancer screening in Korea. Materials and Methods: For participants (n = 256, four institutions) of K-LUCAS pilot study, volume CT dose index ($CTDI_{vol}$) using a 32-cm diameter reference phantom was compared with SSDE, which was recalculated from $CTDI_{vol}$ using size-dependent conversion factor (f-size) based on the body size, as described in the American Association of Physicists in Medicine Report 204. This comparison was subsequently assessed by body mass index (BMI) levels (underweight/normal vs. overweight/obese), and automatic exposure control (AEC) adaptation (yes/no). Results: Size-specific dose estimate was higher than $CTDI_{vol}$ ($2.22{\pm}0.75mGy$ vs. $1.67{\pm}0.60mGy$, p < 0.001), since the f-size was larger than 1.0 for all participants. The ratio of SSDE to $CTDI_{vol}$ was higher in lower BMI groups; 1.26, 1.37, 1.43, and 1.53 in the obese (n = 103), overweight (n = 70), normal (n = 75), and underweight (n = 4), respectively. The ratio of SSDE to $CTDI_{vol}$ was greater in standard-sized participants than in large-sized participants independent of AEC adaptation; with AEC, SSDE/$CTDI_{vol}$ in large- vs. standard-sized participants: $1.30{\pm}0.08$ vs. $1.44{\pm}0.08$ (p < 0.001) and without AEC, $1.32{\pm}0.08$ vs. $1.42{\pm}0.06$ (p < 0.001). Conclusion: Volume CT dose index based on a reference phantom underestimates radiation exposure of LDCT in standard-sized Korean participants. The optimal radiation dose limit needs to be verified for standard-sized Korean participants.

Identification of Irradiation-induced Volatile Flavor Compounds in Irradiated Pork Meats (방사선 조사 돼지고기에서 휘발성 조사물질의 구명)

  • Cha, Yong-Jun;Kim, Hun;Cho, Woo-Jin;Jung, Yeon-Jung;Byun, Myung-Woo;Yoo, Young-Jae
    • Journal of Life Science
    • /
    • v.11 no.1
    • /
    • pp.35-42
    • /
    • 2001
  • Irradiation-induced volatile flavor compounds in irradiated (0, 1, 3, 5, 10 kGy) pork meats were analyzed by liquid liquid continuous extraction (LLCE) and gas chromatography/mass spectrometry (GC/MS) methods. One hundred nine volatile compounds were detected in irradiated pork meats. These compounds were mainly composed of hydrocarbons (42 compounds), aromatic compounds (39), aldehydes(9), ketones(5) and miscellaneous compounds (14). Among these, three volatile compounds, such as decene, 1,2,3,4,-tetrahydro-6-methylnaphthalene and 1,2,3,4-tetrahydro-dimethylnaphthalene were selected as irradiation-induced compounds comparing with irradiation dosages in irradiated pork meats. By the high correlation coefficient with the increment of irradiation dose, however, decene (r=0.93) was considered as marker compound for detecting irradiation dosage in fresh pork meats.

  • PDF

Ultraviolet Protection Property of Green Tea Extract Dyed Fabrics (녹차추출물로 염색한 직물의 자외선 차단성에 관한 연구)

  • Kim, Sin-Hee
    • Textile Coloration and Finishing
    • /
    • v.18 no.6 s.91
    • /
    • pp.80-87
    • /
    • 2006
  • Nowadays, interests of ultraviolet(UV) protection increased, since the UV dosage on the earth surface has increased over years. Overdose of UV can cause various skin, eye, and even DNA damages. Therefore, it is need to develop a proper mean to protect human skin and eye from UV radiation. In this study, the UV protective effect of green tea extract dyed fabrics with various fiber types were examined. Green tea has an active moiety called 'catechin' having benzene rings in its structure, which would exert a proper UV protective property. Green tea dyed fabrics showed the increase in UV protection, and silk showed the highest increase in UV protection (from 52.2% to 84.5% in UV-A, from 66.1% to 90% in UV-B). The order of UV-A protection increase is silk, wool, nylon and acrylic, PET, and cotton. The order of UV-B protection increase is silk nylon, wool, acrylic, cotton, and PET. In case of silk and nylon, the UV protection property gradually increased as the concentration of green tea extract increased. As a result, it was proven that green tea extract dyeing can improve UV protection property of dyed fabrics in environment-friendly and biocompatible manners.