• Title/Summary/Keyword: Radiation device

Search Result 769, Processing Time 0.029 seconds

Research for The Environmental Optimization of Dose and Image quality in Digital Radiography (디지털 방사선촬영 환경에서 선량의 최적화 및 영상품질에 대한 연구)

  • Lee, Kwang Jae;Kim, MinGi;Lee, Jong Woong;Kim, Ho Cheol
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.2
    • /
    • pp.203-209
    • /
    • 2013
  • Digital Radiography (DR) has improved a quality of resolution based on a wide dynamic range, high detective quantum efficiency (DQE), and modulation transfer function (MTF), compared with film/screen(F/s). Unlike expectation that a low level of radiation can be used in examination, high level of signal to noise ratio(SNR) due to over-exposure caused increase of exposed dose to patients. Also, the auto exposure control (AEC) using Kilovolage(kVp) in F/S can cause over-exposure. Hence, in this study, we proposed a proper method for using DR, in which effect of tubing Kilovolage on device's image, DR MTF measurement with changes of tubing current (mA), and the quantitative evaluation of skull phantom captured images' PSNR were evaluated. Changes of contrast with tubing Kilovolage can be improved by retouching, and MTF changes according to tubing current(1.41~1.39 lp/mm in 50% area, and 3.19~2.8 lp/mm in 10% area) does not influence on resolution of image. As a result, high tubing Kilovoltage, and tubing current will be suitable to use of DR.

A Convergence Study on the Contamination and Disinfection of General X-ray generator Practical Equipment (일반촬영 실습 장비의 오염 및 소독에 관한 융합적 연구)

  • Park, Gyu-Tae;Kim, Dong-Heun;Park, Sang-Hee;Jung, Won-Hee;Kim, So-Yeon;Hong, Hee-Jin;Son, Na-Ra;Nam, Seoul-Hee;Han, Man-Seok
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.1
    • /
    • pp.51-56
    • /
    • 2020
  • It is going to select one X-ray generating device for diagnosis in a radiography laboratory at K university in Gangwon-do to detect bacteria on the surface contamination of tables, IP cassettes, and lead gowns for medical radiation shielding and to inform students of the need for proper disinfection control and hand hygiene. Then disinfection was carried out with tissue, tissue cleaner and 70% alchol and immediately collected with sterile cotton swabs to assess the contamination distribution status and disinfection effects of the surface. The results of measuring the degree of contamination on the surface showed that the largest number of bacteria were detected in Apron, and the evaluation of the disinfection effects according to surface contamination showed a noticeable effect at 70% Alcohol in IP Cassette, and the disinfection effect was the same for Apron. Therefore, in order to prevent bacterial infections among students, basic hand washing and regular disinfection should be performed before the practice to prevent infection.

Evaluation of Setup When Using C-Rad System in Radiotherapy (방사선치료 시 C-Rad system을 이용한 셋업의 평가)

  • Park, Eun-Tae;Ko, Seong-Jin;Choi, Seok-Yoon;Kim, Jung-Hoon;Kim, Chang-Soo;Kim, Dong-Hyun;Kang, Se-Sik
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.5
    • /
    • pp.303-310
    • /
    • 2012
  • In radiotherapy, accurate patient positioning and set up are important factor that treatment can influence success. In generally, the 3-laser system is used when the patient set up. But today the body surface scanning system(C-Rad system) is trying to use. Compare and evaluate the C-Rad system and the 3-laser system to check availability. Head and neck that are no movement of internal organs and easy to apply fixation device are limited. Alderson Rando anthropomorphic phantom and 10 patients who have lesions of head and neck are targeted. C-RAD system's setup error mean and standard deviation are the X axis($0.55{\pm}0.51mm$), Y axis($-0.2mm{\pm}0.523mm$), Z axis($-0.85{\pm}0.587mm$) in the phantom study, and in the patient study X axis($-0.05{\pm}0.621mm$), Y axis($0.075{\pm}0.755mm$) Z axis($-1.025{\pm}0.617mm$). So C-RAD system is better than 3-laser system mostly, but C-RAD system's error rate is a little worse than 3-laser system in the Z axis. When radiation treatment of head and neck, body surface contour scanning system contribute to correct positioning and minimize the set up error.

A Study on Dose and Image Quality according to X-ray Photon Detection Method in Digital Radiography System (Digital Radiography System에서 X선 광자 검출 방식에 따른 선량 및 화질 특성에 관한 연구)

  • Hong, Sun Suk;Kim, Ho Chul
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.12
    • /
    • pp.247-253
    • /
    • 2013
  • The purpose is a comparative evaluation in the DR System according to the dosimetry and image quality of the quantitative and objective via Direct digital radiography, Indirect digital radiography, Image intensifier (Charge Coupled Device type) digital radiography. The experimental method used rando phantom and measured the entrance surface dose. And through using the measured entrance surface dose and then using the PCXMC program were evaluated risk due to irradiation and the effective dose. SNR and NPS and CNR were measured and analyzed by using 21cm acryl phantom. Significance of measured value was evaluated by statistics method. Entrance surface dose, major organ dose, effective dose all of them were measured the lowest rated in direct DR when it is on the basis of direct DR dose, high-dose ratio were measured in I.I DR approximately 1.3 times, indirect DR approximately 2.4 times. Risk in accordance with radiation also was measured same as dose ratio. On the conclusion that SNR measurement result based on direct DR SNR measurements, low-SNR ratio were measured in I.I DR approximately 7.25 times, indirect DR approximately 1.48 times. On the conclusion that CNR measurement result based on direct DR CNR measurements, high-dose ratio were measured in I.I type DR approximately 1.16 tims and low-dose ratio were measured in indirect DR approximately 0.87 times. Therefore Direct DR system using a-selenium sensing element to detect x-ray photon is thought effectively at the examination such as infant to sensitive irradiation and the genital gland. Because quality image is built by low dose. Also when it is necessary that image test requiring many diagnosis information, indirect DR system is thought effectively.

Bioimpedence to Assess Breast Density as a Risk Factor for Breast Cancer in Adult Women and Adolescent Girls

  • Maskarinec, Gertraud;Morimoto, Yukiko;Laguana, Michelle B;Novotny, Rachel;Guerrero, Rachael T Leon
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.1
    • /
    • pp.65-71
    • /
    • 2016
  • Although high mammographic density is one of the strongest predictors of breast cancer risk, X-ray based mammography cannot be performed before the recommended screening age, especially not in adolescents and young women. Therefore, new techniques for breast density measurement are of interest. In this pilot study in Guam and Hawaii, we evaluated a radiation-free, bioimpedance device called Electrical Breast Densitometer$^{TM}$ (EBD; senoSENSE Medical Systems, Inc., Ontario, Canada) for measuring breast density in 95 women aged 31-82 years and 41 girls aged 8-18 years. Percent density (PD) was estimated in the women's most recent mammogram using a computer-assisted method. Correlation coefficients and linear regression were applied for statistical analysis. In adult women, mean EBD and PD values of the left and right breasts were $230{\pm}52$ and $226{\pm}50{\Omega}$ and $23.7{\pm}15.1$ and $24.2{\pm}15.2%$, respectively. The EBD measurements were inversely correlated with PD ($r_{Spearman}=-0.52$, p<0.0001); the correlation was stronger in Caucasians ($r_{Spearman}=-0.70$, p<0.0001) than Asians ($r_{Spearman}=-0.54$, p<0.01) and Native Hawaiian/Chamorro/Pacific Islanders ($r_{Spearman}=-0.34$, p=0.06). Using 4 categories of PD (<10, 10-25, 26-50, 51-75%), the respective mean EBD values were $256{\pm}32$, $249{\pm}41$, $202{\pm}46$, and $178{\pm}43{\Omega}$ (p<0.0001). In girls, the mean EBD values in the left and right breast were $148{\pm}40$ and $155{\pm}54{\Omega}$; EBD values decreased from Tanner stages 1 to 4 ($204{\pm}14$, $154{\pm}79$, $136{\pm}43$, and $119{\pm}16{\Omega}$ for stages 1-4, respectively) but were higher at Tanner stage 5 ($165{\pm}30{\Omega}$). With further development, this bioimpedance method may allow for investigations of breast development among adolescent, as well as assessment of breast cancer risk early in life and in populations without access to mammography.

Studies of Automatic Dental Cavity Detection System as an Auxiliary Tool for Diagnosis of Dental Caries in Digital X-ray Image (디지털 X-선 영상을 통한 치아우식증 진단 보조 시스템으로써 치아 와동 자동 검출 프로그램 연구)

  • Huh, Jangyong;Nam, Haewon;Kim, Juhae;Park, Jiman;Shin, Sukyoung;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.26 no.1
    • /
    • pp.52-58
    • /
    • 2015
  • The automated dental cavity detection program for a new concept intra-oral dental x-ray imaging device, an auxiliary diagnosis system, which is able to assist a dentist to identify dental caries in an early stage and to make an accurate diagnosis, was to be developed. The primary theory of the automatic dental cavity detection program is divided into two algorithms; one is an image segmentation skill to discriminate between a dental cavity and a normal tooth and the other is a computational method to analyze feature of an tooth image and take an advantage of it for detection of dental cavities. In the present study, it is, first, evaluated how accurately the DRLSE (Direct Regularized Level Set Evolution) method extracts demarcation surrounding the dental cavity. In order to evaluate the ability of the developed algorithm to automatically detect dental cavities, 7 tooth phantoms from incisor to molar were fabricated which contained a various form of cavities. Then, dental cavities in the tooth phantom images were analyzed with the developed algorithm. Except for two cavities whose contours were identified partially, the contours of 12 cavities were correctly discriminated by the automated dental caries detection program, which, consequently, proved the practical feasibility of the automatic dental lesion detection algorithm. However, an efficient and enhanced algorithm is required for its application to the actual dental diagnosis since shapes or conditions of the dental caries are different between individuals and complicated. In the future, the automatic dental cavity detection system will be improved adding pattern recognition or machine learning based algorithm which can deal with information of tooth status.

Study on Usefulness of Entrance Surface Dose (ESD), Entropy Analysis Method to Evaluate Ionization Chamber Performance and Implementation of Optimal Chamber Combination Model when using Automatic Exposure Control (AEC) Device in Digital Radiography (DR) (디지털 방사선 시스템(DR)의 자동노출제어장치 이용 시 이온 챔버의 성능 평가를 위한 엔트로피 분석법의 유용성과 최적의 챔버 조합 모델 구현 연구)

  • Hwang, Jun-Ho;Choi, Ji-An;Lee, Kyung-Bae
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.375-383
    • /
    • 2020
  • This study aimed to propose a methodology for quantitatively analyzing problems resulting from the performance and combination of the ionization chamber when using an automatic exposure control (AEC) and to optimize the performance of the digital radiography (DR). In the experimental method, the X-ray quality of the parameters used for the examination of the abdomen and pelvis was evaluated by percentage average error (PAE) and half value layer (HVL). Then, the stability of the radiation output and the image quality were analyzed by calculating the entrance surface dose (ESD) and entropy when the three ionization chambers were combined. As a result, all of the X-ray quality of the digital radiography used in the experiment showed a percentage average error and a half value layer in the normal range. The entrance surface dose increased in proportion to the combination of chambers, and entropy increased in proportion to the combination of ionization chambers except when three chambers were combined. In conclusion, analysis using entrance surface dose and entropy was found to be a useful method for evaluating the performance and combination problems of the ionization chamber, and the optimal performance of the digital radiography can be maintained when two or less ionization chambers are combined.

Evaluation of High Absorption Photoconductor for Application to Auto Exposure Control Sensor by Screen Printing Method (자동노출제어장치 센서적용을 위한 스크린 프린팅 제작방식의 고흡수율 광도전체 특성평가)

  • Kim, Dae-Kuk;Kim, Kyo-Tae;Park, Jeong-Eun;Hong, Ju-Yeon;Kim, Jin-Seon;Oh, Kyung-Min;Nam, Sang-Hee
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.2
    • /
    • pp.67-72
    • /
    • 2015
  • In diagnostic radiology, the use of automatic exposure control device is internationally recommended for diagnosis and optimization. However, if exposed to prolonged radiation is a complicated manufacturing process, there is a problem that occurs decrease of various performance overall brightness sensor, which is commercially available conventional. Therefore, in this study, absorption of X-ray is high, and I want to evaluate the AEC applicability of the sensor of the photoconductor-based production has an easy advantage. Experimental results confirms the possibility of fabrication of the sensor through an increase in the SNR, with the detection efficiency superior, accurate turn-off. In addition, it is confirmed that the experimental results of the transmittance and the latent image, Ghost effect by the light conductor does not appear, in the case of a photoconductor with the exception of the PbO, 80% - and it was confirmed good transmittance of 90%. Therefore, excellent mechanical stability and poor performance due to a change of the doping concentration than the existing products that have been put to practical use, the sensor easy photoconductor based, fabrication and can be applied as AEC sensor is expected.

Study of 4π Compton Suppression Spectrometer by Monte Carlo Simulation (몬테카를로 시뮬레이션을 통한 4π 컴프턴 억제 분광기 연구)

  • Jang, Eun-Sung;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.3
    • /
    • pp.123-129
    • /
    • 2017
  • Compton suppression apparatus using the Compton scattering response, by inhibiting part of the spectrum Compton continuum Compton continuum in the area of the peak analysis of the gamma rays that enables a clearer device. In order to find out the geometry structure of high-purity germanium detector(HPGe) -NaI(TI) and to optimize the effect of movement, Monte Carlo simulation was used to grasp the behavioral characteristics of Compton suppression and compare several layout structures. And applied to the cylinder beaker used for the environmental measurement by using the efficiency according to the distance. For the low-energy source such as 81 keV, the Compton continuum is scarcely developed and the suppression effect is also insignificant because the scattering cross-section of the Compton effect is relatively low. In the spectrum for the remaining energy, it can be seen that the Compton continuum part is suppressed in a certain energy range. Compton suppression effect was not significantly different from positional shift. average reduction factor(ARF) value was about 1.08 for 81 keV and about 1.23 for 1332.4keV energy at the highest value. It can be seen that suppression over the Compton continuum region of the energy spectrum is a more appropriate arrangement. Therefore, it can be applied to various environmental sample measurement through optimized structure.

Experimental Investigation of Variable Emittance Material Based on (La, Sr)MnO3 ((La, Sr)MnO3을 이용한 가변 방사율 소재에 관한 연구)

  • Han, Sunwoo;Choi, Bongsu;Song, Tae-Ho;Kim, Sun Jin;Lee, Bong Jae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.6
    • /
    • pp.583-590
    • /
    • 2013
  • Variable emittance radiators can be used in a thermal management system in space because their total emittance changes depending on the temperature of the system. When the temperature of the system decreased, the emittance also decreased so as to minimize the heat loss to the environment. In contrast, when the temperature of the system increased, the emittance also increased such that radiation cooling could occur. Thermochromic materials, whose emittance is a function of the temperature, are often used in variable emittance radiators because no additional parts are needed. In this study, we fabricated a variable-emittance coating by using a sol-gel method based on LSMO ($La_{1-x}Sr_xMnO_3$) and experimentally characterized the emittance change with respect to temperature. Furthermore, we also examined the stability of LSMO film in space environments by exposing it to extremely low pressure and temperature.