• 제목/요약/키워드: Radiation detection circuit

검색결과 35건 처리시간 0.024초

자동 감마 증류탑 검사 장치를 위한 방사선 계측장치 설계 (Design of radiation detection circuit for gamma column scanning)

  • 김종범;정성희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.612-615
    • /
    • 2003
  • In this paper, a design of radiation detector for gamma column scanner is introduced. Distillation column is important unit in Petro-chemical industries, and its on-line diagnose is very important. To get density profile measured by the radiation transmitted through column is well method for on-line diagnose as gamma scanning. For this purpose radiation detection circuit, radiation source and mechanical system for moving source and detector are required. Conventional radiation detection circuit for this application is sensitive to electric noise because of interface between the radiation circuit and the controller for mechanical system. The radiation detection system introduced here is using loop coil instead of slip ring to remove contact noise. Radiation detection system designed here for gamma scanning consist of BGO detector, high voltage circuit, PHA circuit and FSK modem. The BGO detector is used as radiation sensor, high voltage circuit and peak height analysis circuit is essential to process the signal generated from BGO detector. Micro controller convert measured data into ASCII data. FSK modem transmit ASCII data. Transmitted ASCH data is picked up in antenna coil and processed for combined function with mechanical system. This method gives good result by isolating the controlling circuit of mechanical system from radiation detecting circuit which is sensitive to noise.

  • PDF

다목적 수동형 라돈농도 측정기 개발 (Development of A Multipurpose Passive Type Radon Monitor)

  • 이봉재;박영웅
    • 동위원소회보
    • /
    • 제21권4호
    • /
    • pp.55-65
    • /
    • 2006
  • A passive type radon monitor adopting two silicon PIN detector as radiation detector has been developed, manufactured and test-evaluated. A radiation signal processing circuit has been electronically tested and then the radiation detection characteristics of this instrument has been performance-tested by using reference radon concentration and a reference photon radiation field. As a result, in a electronic performance test, radiation signals from each detector were well observed in each signal processing circuit. The radiation detection sensitivity of this instrument after several test-irradiations to a Cs-137 gamma radiation source and a standard radon concentration appeared to be 1.37 cph/$\mu$Svh-1 and 1.66 pCi/L respectively. The developed radon monitor in this paper could be used conveniently in monitoring of radon concentration in buildings which population utilize in Korea.

  • PDF

펄스방사선 탐지를 위한 Photo Diode 출력특성 연구 (The Study of the Photo Diode Output Signal for Pusle Radiation Detection)

  • 황영관;이남호
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2012년도 춘계학술대회
    • /
    • pp.869-871
    • /
    • 2012
  • 고도의 과학기술발전으로 인해 일상생활에서 전자기기의 사용이 급속도로 늘어가고 있다. 또한 태양의 흑점 폭발이나 북한의 핵폭탄, 원전 사고 등으로 인해 방사선에 대한 관심도가 증가하고 있다. 태양으로부터 방출되는 펄스형태의 방사선은 전자장비에 장애를 초래하며 특히 핵폭발 시 전달되는 고준위 펄스 방사선의 경우 전자부품에 오동작 및 불용상태로 까지 영향을 미칠 수 있다. 이러한 방사선 영향에 대한 연구는 국내외에서 다양하게 진행되고 있다. 본 논문에서는 이러한 전자 부품에 영향을 줄 수 있는 펄스방사선 탐지를 위해 Si 기반의 포토다이오드를 제작하고 이를 통해 펄스 입출력 신호에 대한 회로 시뮬레이션과 일반 광원을 이용한 출력 특성을 연구하였다. 본 연구의 결과는 고 에너지의 펄스 방사선 영향으로부터 전자회로를 보호하기 위한 추가적인 모듈의 입력 센서로 활용 될 수 있다.

  • PDF

실리콘 PIN 다이오드 검출기를 이용한 전자선량계 개발 (Development of Prototype Electronic Dosimeter using the Silicon PIN Diode Detector)

  • 이봉재;김봉환;장시영;김종수
    • Journal of Radiation Protection and Research
    • /
    • 제25권4호
    • /
    • pp.197-205
    • /
    • 2000
  • 실리콘 PIN 다이오드 검출기를 이용하여 전자선량계(PED)를 설계 및 제작하고, 전자신호회로의 성능과 방사선 검출 반응특성을 평가하였다. 전자회로의 성능검사에서는 방사선에 의한 검출기의 신호가 신호처리회로에서 양호하게 출력되었으며, $^{137}Cs$ 감마 방사선을 이용한 방사선조사 시험결과 선량계의 반응도 및 분산계수는 각각 1.85 cps/$Gy{\cdot}h^{-1}$ 및 19.3%로 측정되어 전자선량제의 성능기준을 만족하는 것으로 나타났다. 본 전자선량계의 시작품은 향후 전자회로의 성능향상과 작동 프로그램을 보완 및 개선함으로써 개인 방사선 모니터링에 활용될 것으로 기대된다.

  • PDF

Fault Detection 기능을 갖는 이오나이저 모듈용 게이트 구동 칩 설계 (Design of Gate Driver Chip for Ionizer Modules with Fault Detection Function)

  • 김홍주;하판봉;김영희
    • 전기전자학회논문지
    • /
    • 제24권1호
    • /
    • pp.132-139
    • /
    • 2020
  • 공기청정기에 사용되는 이오나이저 모듈은 권선형 transformer를 사용하여 방전전극인 HV+/HV-에 3.5KV/-4KV의 고전압을 공급하여 carbon fiber brush의 전계 방사에 의해 양이온과 음이온을 발생시킨다. 기존의 MCU를 이용한 이오나이저 모듈 회로는 PCB 사이즈가 크고 가격이 비싼 단점이 있고, 기존의 ring oscillator를 이용한 게이트 구동 칩은 oscillation 주기가 PVT(Process-Voltage-Temperature) 변동에 민감하고 HV+와 GND, HV-와 GND의 단락에 의한 fault detection 기능이 없으므로 화재나 감전의 위험이 있다. 그래서 본 논문에서는 7bit binary UP counter를 이용하여 PVT 변동이 있더라도 oscillation 주기를 조절하여 HV+ 전압이 목표 전압에 도달하게 한다. 그리고 HV+와 GND 사이의 단락을 검출하기 위한 HV+ short fault detection 회로, HV-와 GND 사이의 단락을 검출하기 위한 HV- short fault detection 회로와 HV+가 과전압 이상으로 올라가는 것을 검출하기 위한 OVP(Over-Voltage Protection) 회로를 새롭게 제안하였다.

삼중화된 회로에서의 결함 감지를 위한 방법에 관한 연구 (A Study on Fault Detection Scheme on TMRed Circuits)

  • 강동수;이종길;장경선
    • 한국정보과학회:학술대회논문집
    • /
    • 한국정보과학회 2011년도 한국컴퓨터종합학술대회논문집 Vol.38 No.1(B)
    • /
    • pp.313-316
    • /
    • 2011
  • SRAM-based FPGAs are very sensitive to single event upset(SEU) induced by space irradiation. To mitigate SEU effects, space applications employ some mitigation schemes. The triple modular redundancy(TMR) is a well-known mitigation scheme. It uses one or three voters as well as three identical blocks performing the same work. The voters can mask out one error in the outputs from the three replicated blocks. One SEU error in TMRed circuits can be masked but it needs to be detected for some reasons such as to analyze the SEU effects in the satellite or to recover the circuits from the error before additional error occur. In this paper, we developed a fault detection circuit and reporting system to detect a fault on the TMRed circuits. To verify our error detection circuit and reporting circuit, we performed an irradiation test at MC-50 Cyclotron. Experimental results showed that error detection circuit can detect a fault on the TMRed test circuit in radiation environment.

전자기유도기술을 이용한 유선 태블릿 좌표 측정 (Coordinate Measurement in Wired Tablet Using a Electromagnetic Induction System)

  • 홍동구;유영기
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2008년도 하계종합학술대회
    • /
    • pp.1099-1100
    • /
    • 2008
  • In this paper, we would like to introduce a simple and low cost wired pointing device by using a electromagnetic induction. A number of patents of Wacom describe electronic drawing devices or styluses. The movement of the stylus over a tablet is traced electronically and used applied to a resonant circuit in the stylus. Electromagnetic radiation emitted by the resonant circuit is detected by a sensing mechanism and location processing is used to locate the stylus. In this research, difference coil principle is used to detect the emitted radiation of the resonant circuit in the pen. This detection device shows good performance to detect the location of the pen on the tablet.

  • PDF

원형방사상편향에 의한 방사능계측용 기록장치 (A Recording System For Nuclear Radation Detection by Means Of Circular Radial Deflection)

  • 이희용
    • 대한전자공학회논문지
    • /
    • 제3권3호
    • /
    • pp.14-21
    • /
    • 1966
  • 원형방사상편향의 기록방식을 이용한 방사선계측장치로서 그 장치내용과 계측에의 응용례를 기술하였다. 장치의 전자관회로에 있어서 특수한 승산회로를 안출하므로써 원형시간축 뿐만 아니라 그 위에 나타난 펄스의 직선성도 잘 고려되었다. 논리회로에 의해서 1싸이클동안만 밝게하고 다음의 수사이클 동안을 어둡게 하므로써 방사선에 의한 랜돔 펄스를 원형시간축상에 나타내어 이것을 사진으로 기록할 수 있게 하였다. 본장치는 단수명핵종의 감리곡선과 그 파고분포곡선을 얻는데 적당한 것이다.

  • PDF

인체 움직임을 고려한 소형 근접 마이크로파 심박 센서 (Compact Microwave Heartbeat Proximity Sensor Under Human Body Movement)

  • 윤기호
    • 한국융합학회논문지
    • /
    • 제11권10호
    • /
    • pp.63-69
    • /
    • 2020
  • 본 논문에서는 저속으로 불규칙하게 움직이는 인체의 심박신호를 감지하기 할 수 있어 웨어러블 디바이스에 적용 가능한 소형 마이크로파 센서를 제안하였다. 이를 위해 2.4 GHz ISM 대역에서 평형 구조를 갖는 마이크로스트립 방사 패치들과 자체발진 검출회로 및 귀환회로가 구성되었다. 이론 전개와 시뮬레이션을 통해 제안된 구조의 타당성을 확인하였고 제작된 시제품을 측정하였다. 회로의 보드는 65mm × 85㎟의 작은 크기이며, 간단한 고주파 회로구조로 60mW 수준의 작은 전력을 소모한다. 센서와 직선거리 2~30mm, 측면 좌우 거리 ±20mm 범위 내에서 저속(0.5Hz)으로 움직이는 인체로부터 심박신호를 얻을 수 있었다.

Long term activity measurement of the primary circuit water on the LVR-15 research reactor

  • Ladislav Viererbl;Vit Klupak;Hana Assmann Vratislavska
    • Nuclear Engineering and Technology
    • /
    • 제56권4호
    • /
    • pp.1250-1253
    • /
    • 2024
  • Activity measurement of the primary circuit water of fission reactors is one method that can provide early detection of a damaged fuel assembly in the reactor core. This is an important aspect in the safe operation of the reactor and for radiation protection of staff. Radionuclides in the primary circuit water are produced by the activation of stable nuclides and the fission of fissile nuclides, mainly the isotope 235U. In the LVR-15 research reactor, measurement of the activity of the primary circuit water has been regularly undertaken since 1996. A water sample is taken from the primary circuit every week and the activities are measured four days later using gamma spectrometry. The results of these long-term measurements from 1996 to 2022 are presented. The activity time dependences of the individual radionuclides are discussed in relation to fuel assembly damage and for events connected to contamination of the water by objects inserted into the primary circuit during experiments carried out near the reactor core.