• 제목/요약/키워드: Radiation control area

검색결과 235건 처리시간 0.023초

림프구의 미소핵을 지표로 영광 원자력발전소 주변 사육 돼지의 방사선 생물학적 평가 (Radiobiological Evaluation in Pig Bred in the Vicinity of Yeonggwang Nuclear Power Station Using Micronuclei in Cytokinesis-blocked Lymphocyte)

  • 김세라;강창모;김성호
    • 한국임상수의학회지
    • /
    • 제21권3호
    • /
    • pp.286-290
    • /
    • 2004
  • Cytogenetic and hematological analysis was performed in peripheral blood of pig in the vicinity of Yeonggwang nuclear power station and control area. The frequency of micronuclei (MN) in peripheral blood lymphocytes from pig was used as a biomarker of radiobiological effects resulting from exposure to environmental radiation. An estimated dose of radiation was calculated by a best fitting linear-quadratic model based on the radiation-induced MN formation from the swine lymphocytes exposed in vitro to radiation over the range from 0 Gy to 4 Gy. MN rates in lymphocytes of pig from Yeonggwang nuclear power station and control area were 10.60/1,000 and 11.10/1,000, respectively. There were no significant differences in MN frequencies and hematological values in pig between Yeonggwang and control area. The study indicates that the MN assay in lymphocyte of pig is a rapid, sensitive and accurate method that can be used to monitor a large population exposed to radiation.

세포질 분열 차단 림프구를 이용한 울진원자력발전소 주변 소의 미소핵 발생 평가 (Evaluation of micronucleus frequency in cytokinesis-blockedlymphocytes of cattle in the vicinity of Uljin nuclear power station)

  • 김세라;강창모;김성호
    • 대한수의학회지
    • /
    • 제44권3호
    • /
    • pp.343-348
    • /
    • 2004
  • Cytogenetic and hematological analysis was performed in peripheral blood of cattle in the vicinity of Uljin nuclear power station and control area. The frequency of micronuclei(MN) in peripheral blood lymphocytes from cattle was used as a biomarker of radiobiological effects resulting from exposure to environmental radiation. An estimated dose of radiation was calculated by a best fitting linear-quadratic model based on the radiation-induced MN formation from the bovine lymphocytes exposed in vitro to radiation over the range from 0 Gy to 4 Gy. MN ratio in lymphocytes of cattle from Uljin nuclear power station and control area were 8.90/1,000 and 9.60/1,000, respectively. There were no significant differences in MN frequencies and hematological values in cattle between Uljin and control area.

방사선 영상 매핑 장치 (Radiation image mapping system)

  • 최영수;박순용;이종민
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.1884-1887
    • /
    • 1997
  • The increasing concern over radiation exposure in the nuclear industry has fostered agrressive efforts to reduce the levels of radiation exposure. One area of the effot to reduce the radiation exposure is the development of a remote radiation monitoring system. Remote radiation monitoring can serve many benificaial functions reduce exposure to radiation by plant personnel, impruve the quality of the data that is collected and recognize the radiation environment easily. Radiation mapping system gives a good information that represents radiation level distribution. The system we have developed consists of a data acquistion parts, mobile robot and remote control parts. Data acquisition parts consist of radiation detection module and vision acquistion module which collect radiation data, visiion data and distance information. In remote control parts, the acquision data are processed and displayed. We have constructed radiation mapping image by overlaying the vision and radiation data. The radiation mapping techniques for displaying the results of the survey in an easily comprehendable form will facilitate a better understanding of the radiation environment in the facility. This system can reduce workers radiation exposure and aid to help work plan, so it has significant benifits in cost and safety.

  • PDF

세포질 분열 차단 림프구를 이용한 월성원자력발전소 주변 소의 미소핵 발생 평가 (Evaluation of Micronucleus Frequency in Cytokinesis-blocked Bovine Lymphocytes from Regions around Wolsong Nuclear Power Plant)

  • 김세라;김태환;김성호
    • 대한수의학회지
    • /
    • 제43권3호
    • /
    • pp.333-338
    • /
    • 2003
  • Cytogenetic and hematological analysis was performed in bovine peripheral blood from the regions around Wolsong nuclear power plant and control area. The frequency of micronuclei (MN) in peripheral blood lymphocytes from cattle was used as a biomarker of radiobiological effects resulting from exposure to environmental radiation. An estimated dare of radiation was calculated by a best fitting linear-quadratic model based on the radiation-induced MN formation from the bovine lymphocytes exposed in vitro to radiation over the range from 0 Gy to 4 Gy. MN rates in lymphocytes of cattle from Wolsong nuclear power plant and control area were 9.87/1,000 and 9.60/1,000, respectively. There were no significant differences in MN frequencies and hematological values in cattle between Wolsong and control area. The study indicates that the MN assay is a rapid, sensitive and accurate method that can be used to monitor a large population exposed to radiation.

림프구 미소핵 측정법을 이용한 원자력발전소 주변 소의 이상산에 대한 방사선 생물학적 평가 (The Radiobiological Evaluation on Abnormal Delivery of Cattle around Nuclear Power Plant using Micronucleus Assay in Lymphocyte)

  • 김세라;김성호
    • 한국임상수의학회지
    • /
    • 제20권3호
    • /
    • pp.364-368
    • /
    • 2003
  • Cytogenetic and hematological analysis was performed in peripheral blood from the cattle associated with abnormal delivery around nuclear power plant area. The frequency of micronuclei (MN) in peripheral blood lymphocytes from cattle was used as a biomarker of radiobiological effects resulting from exposure to environmental radiation. An estimated dose of radiation was calculated by best fitting linear-quadratic model based on the radiation-induced MN data over the range from 0 Gy to 4 Gy from the bovine lymphocytes with in vitro irradiation. MN rates in live malformed calf, dams of malformed calves and other cattle living in the same barn from the regions around nuclear power plant, and cattle in control area were 9/1000, 10.8/1000, 13.3/1000 and 10.0/1000, respectively. There were no significant differences in MN frequencies and hematological values between the cattle associated with abnormal delivery around nuclear power plant area and those of control area. This study indicates that the congenital abnormalities near nuclear power plant seemed to be caused by other aetiology.

방사선촬영에서 면적선량 및 새로운 실질면적선량 개념의 비교 평가 (Comparative Evaluation of Kerma Area Product and New Fundamental of Kerma Area Product on Radiography)

  • 최우철;김용민;김정수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권1호
    • /
    • pp.53-58
    • /
    • 2021
  • Kerma Area Product (KAP) is best indicator of radiation monitoring on radiographic examinations. KAP can be measured differently depending on the X-ray irradiation area, air kerma, souce-skin distance, type of equipment, etc. The major factors are exposure area and the air krema. The KAP currently used only considers the exposure area with X-rays and has a problem that KAP is always excessively overestimated from the dose received by an actual subject. Therefore, in this study, in order to measure the accurate KAP, a new area dose calculation that can be calculated by dividing the area where the actual X-ray is irradiated is presented, and the KAP is the real area. We compared and analyzed how much it was overestimated compared to the dose. The Skull AP projection and seven other projection were compared and analyzed, and the KAP was overestimated in each test by 52% to 60%. In this way, the effective KAP (EKAP) calculation developed through this study should be utilized to prevent extra calculation of the existing KAP, and only the accurate patient subject area should be calculated to derive the accurate area dose value. EKAP is helpful for control the patient's exposure dose more finely, and it is useful for the quality control of medical radiation exposure.

원자력 및 핵의학 분야용 Total RMS (Radiation Monitoring System)의 설계 (Design of Total RMS(Radiation Monitoring System) for nuclear and nuclear medicine)

  • 고태영;이주현;이승호
    • 전기전자학회논문지
    • /
    • 제21권2호
    • /
    • pp.158-161
    • /
    • 2017
  • 본 논문에서는 원자력 및 핵의학 분야용 Total RMS(Radiation Monitoring System)를 제안한다. 제안하는 시스템은 Stack Monitor, Area Monitor, Water(Liquid) Monitor 등을 하나의 시스템으로 확장 및 제어할 수 있는 장비로 각 방사선 검출기에서 측정된 신호를 통합 모니터링 할 수 있다. 제안하는 시스템은 해당 방사선을 검출하는 Sensor Module, 방사선 검출 위치에 인접한 곳에서 방사선량을 디스플레이 하는 Display Unit, 검출된 방사선량이 위험 수준에 도달시 경보를 알리는 Alarm Unit, 각 모니터링에서 측정된 방사선량들을 취합하고 저장하여 원격 감시 시스템에 내용을 전달하는 Main Hub, 원격지에서 측정된 방사선량 상태를 일목요연하게 디스플레이 하는 RMS Monitoring Unit 등으로 구성된다. 제안된 원자력 및 핵의학 분야용 Total RMS의 성능을 평가하기 위하여 공인시험기관에서 실험한 결과, 측정 불확도가 8.5%이하로 측정되어 국제 표준인 ${\pm}15%$ 이하에서 정상동작 됨이 확인되었다.

The Visual Performance Evaluation of the Work planes with the Automated blind Control in Small Office Spaces

  • Park, Doo-Yong;Yoon, Kap-Chun;Kim, Kang-Soo
    • KIEAE Journal
    • /
    • 제14권1호
    • /
    • pp.15-22
    • /
    • 2014
  • Among the various building envelope elements, the glass area takes up the largest portion in the office building design. However, a large area of glass can cause problems such as excessive solar radiation, thermal comfort, and glare. Thus it is important to install the glass area to an appropriate level, and control solar radiation and inflow of daylight with blind devices. This study aims to improve the visual performance of the work plane through the automatic control of the venetian blinds. A total of eight kinds of control strategies were chosen; Case 1 does not control the blinds, Case 2 with the blind slats fixed at the angle of 0 degree, Case 3 to 6 using the existing blind control programs, and Case 7 and 8 with improved blind control. Case 3 with 90 degrees had the best energy performance, but the average indoor illuminance was 113lux, which is below the standards. Cases 4 and 5 showed higher levels of interior daylight illuminance with the average of 281lux and 403lux respectively. However, the fixed angles may have difficulties controlling excessive direct sunlight coming into the room and may cause glare. Cases 6 and 7 used sun tracking angle control and cut-off angle control, and the average interior illuminance was measured 250lux and 385lux respectively. Case 8 used the cut-off angle control in an hourly manner, satisfying the standard illuminance of 400lux with an average interior illuminance of 561lux. It was evaluated to be the best method to control direct solar radiation and to guarantee proper level of interior illumination.

촬상관타입의 원격모듈화 내방사선 카메라시스템 연구 (The Study on the Radiation-Proof Video Camera system Remote Module of the Tube type)

  • 백동현
    • 한국정보전자통신기술학회논문지
    • /
    • 제11권6호
    • /
    • pp.793-799
    • /
    • 2018
  • CCD카메라는 방사선에 쉽게 열화되어 고방사선구역에서는 촬상관을 이용한 일체화된 카메라가 사용되고 있다. 이를 방사선에 강한 전자부품을 사용한 카메라헤드부와 방사선에 약한 TR, IC등을 사용한 원격제어부로 분리제작한 내 방사선 카메라시스템을 구현하였다. 실험결과 전자부품 중 가장 먼저 손상된 것은 수평 및 수직 동기 발생 IC이었으며 $2{\times}10^5{\sim}10^6rad$의 방사선이 누적되면 정상적인 기능이 상실됨을 확인하였다. 또한 원격화를 위한 신호전송 케이블은 입출력 버퍼회로를 부가하고 쉴드와 케이블의 폐루프면적을 감소시켜 신호 손실보정 및 노이즈를 제거하였다. 따라서 전체의 시스템을 교체하는 것이 아니라 카메라 헤드부분만을 교체하여 사용할 수 있으므로 실용적이며 관리 유지비용이 많이 절감 될 것으로 기대된다.

광릉수목원 혼합림에서 복사 에너지의 계절 변화 특성 (Characteristics of the Seasonal Variation of the Radiation in a Mixed Forest at Kwangneung Arboretum)

  • 김연희;조경숙;김현탁;엄향희;최병철
    • 한국대기환경학회지
    • /
    • 제19권3호
    • /
    • pp.285-296
    • /
    • 2003
  • The measurement of the radiation energy, trunk temperature, leaf area index (LAI), air temperature, vapor pres-sure, and precipitation has been conducted under a mixed forest at Kwangneung Arboretum during the period of 2001. Characteristics of the diurnal and seasonal variation of the radiative energy were investigated. The aerodynamic roughness length was determined as about 1.6 m and the mean albedo was about 0.1 The downward short-wave radiation was linearly correlated with the net radiation and its correlation coefficient was about 0.96. From this linear relation, the heating coefficient was calculated and its annual mean value was about 0.21 The albedo and heating coefficient was varied with season, surface characteristics, and meteorological conditions. The diurnal and seasonal variations of radiation energy were discussed in terms of the surface characteristics and meteorological conditions. In the daytime, during clear skies, net radiation was dominated by the shortwave radiation. In presence of clouds and fog, the radiation energy was diminished. At night, the net radiation was entirely dominated due to the net longwave radiation. There was no distinct diurnal variation in net radiation flux during the overcast or rainy days. The net radiation was strongest in spring and weakest in winter. The seasonal development in leaf area was also reflected in a strong seasonal pattern of the radiation energy balance. The timing, duration, and maximum leaf area and trunk temperature were found to be an important control on radiation energy budget. The trunk temperature was either equal or warmer than air temperature during most of the growing season because the canopy could absorb a substantial amount of sunlight. After autumn (after the middle of October), the trunk temperature was consistently cooler than air temperature.