• 제목/요약/키워드: Radiation absorbed dose

검색결과 407건 처리시간 0.024초

수술 중 C-Arm Neutral AP 검사 시 조절인자에 따른 피폭선량 및 화질비교(L-Spine AP검사를 기준으로) (Study of Factors Controlling Exposure Dose and Image Quality of C-arm in Operation Room according to Detector Size of It (Mainly L-Spine AP Study))

  • 최성현;조황우;동경래;정운관;최은진;송하진
    • 방사선산업학회지
    • /
    • 제9권2호
    • /
    • pp.85-90
    • /
    • 2015
  • Purpose: Time of operation has been reduced and accuracy of operation has been improved since C-arm, which offer real-time image of patient, was introduced in operation room. However, because of the contamination of patient, C-arm could not be used more appropriately. Therefore, this study is to know factors of controlling exposure dose, image quality and the exposed dose of health professional in operation room. Materials and methods: Height of Wilson frame (bed for operation) was fixed at 130 cm. Then, Model 76-2 Phantom, which was set by assembling manual of Fluke Company, was set on the bed. Head/Spine Fluoroscopy AEC mode was set for exposure condition. According to detector size of C-arm, the absorbed dose per min was measured in the 7 steps OFD (cm) from 10 cm to 40 cm (10, 15, 20, 25, 30, 35, 40 cm). In each step of OFD, the absorbed dose per min of same diameter of collimation was measured. Moreover, using Nero MAX Model 8000, exposure dose per min was measured according to 3 step of distance from detector (20 cm, 60 cm, 100 cm). Finally, resolution was measured by CDRH Disc Phantom and magnification of each OFD was measured by aluminum stick bar. Result: According to detector size of C-arm, difference of absorbed dose shows that the dose of 20 cm OFD is 1.750 times higher than the dose of 40 cm OFD. It means that the C-arm, which has smaller size of detector, shows the bigger difference of absorbed dose per min (p<0.05). In the difference of absorbed dose in the same step of OFD (from 20 cm to 40 cm), the absorbed dose of 9 inch detect or C-arm was 1.370 times higher than 12 inch' s (p<0.05). When OFD was set to 20 cm OFD, the absorbed dose of non-collimation case was approximately 0.816 times lower than the absorbed dose of collimation cases (p<0.05). When the distance was 20 cm from detector, exposed does includes first-ray and scatter-ray. When the distance was 60 cm and 100 cm from detector, exposed does includes just scatter-ray. So, there was the 2.200 times difference of absorbed does. Finally, when OFD was increased, spatial resolution was 4 to 5 step was increased. However, low contrast resolution was not relative. Moreover, there was 1.363 times difference of magnification (p<0.05). Conclusion: When C-Arm is used, avoiding contamination of patient is more important factor than reducing exposed dose of health professional in operation room. Just controlling exposure time is just way to reduce the exposed does of workers. However, in the case, non-probability influence could be occurred. Therefore, this study proved that the exposed dose will be reduced if the factors such as using small detector size of C-arm, setting OFD from 20 cm to 25 cm and non-collimating. Moreover, dose management of C-arm in the non-interesting area will be considered additionally.

일반 및 호흡조절 방사선치료계획에서 심장의 흡수선량 변화 (A Change in an Absorbed Dose of the Heart in General and Respiratory Control Radiation Treatment Plans)

  • 양은주;김영재
    • 한국방사선학회논문지
    • /
    • 제12권3호
    • /
    • pp.313-319
    • /
    • 2018
  • 방사선 치료시 산란성 등의 피부영향을 피할 수 없으며 내부의 정상장기의 피폭은 피할 수 없다. 방사선 치료의 역사는 정상조직의 흡수선량 감소를 위한 역사라고 해도 과언이 아니다. 특히, 왼쪽 유방암의 방사선 치료시 내부 인접 장기로는 정상유방조직, 심장과 폐를 대표로 들 수 있는데 심장에 발생할 수 있는 부작용은 심정지, 심근경색 등이 있다. 본 논문에서는 왼쪽 유방암 환자의 방사선 치료시 호흡조절기법을 사용한 것과 일반 방사선치료계획을 시행하는 것 사이에 심장의 체적과 선량의 변화를 관찰하여 호흡으로 인해 발생하는 심장의 체적과 선량을 알아보았다. 연구결과 4차원 컴퓨터 단층촬영영상을 기준으로 심장의 체적은 평균 $12.8{\pm}8.7cc$의 차이가 나타났으며 이에 대해 선량은 평균 $17.3{\pm}12.1cGy$의 차이를 보였다. 이러한 체적과 선량의 차이는 향후 방사선 치료시 부작용을 발생시킬 수 있는 우려가 있으므로 호흡조절기법을 활용하여 심장의 정확한 위치를 기반으로 방사선 치료계획을 수립하여야 할 것이다.

흡수선량 측정 시 동종 원통형 이온함에서 이온함 간 변화 (Chamber-to-chamber Variations in the Same Type of a Cylindrical Chamber for the Measurements of Absorbed Doses)

  • 김성훈;허현도;최상현;김혁주;임천일;신동오;최진호
    • 한국의학물리학회지:의학물리
    • /
    • 제21권1호
    • /
    • pp.120-125
    • /
    • 2010
  • 물흡수선량에 기반한 표준 측정법을 사용하여 흡수선량을 측정 시에 여러 요인들이 크건, 작건, 미미하건 간에 선량 측정의 정확성에 영향을 미칠 수 있다. 이온함의 선질 보정 인자(the beam quality correction factor) ${\kappa}_{Q,Q_0}$ 값 또한 그 중 한 요인이 될 수 있다. 본 연구에서는 특정 이온함 유형(PTW30013, PTW, Germany)을 선정하여, 국내에서 사용하고 있는 기관들로부터 9개의 이온함을 수집하였다. 동일한 전위계와 전기선으로 9개 이온함을 국내 이차표준기관으로부터 교정을 받았다. 이렇게 교정받은 이온함들을 사용하여 Siemens ONCOR 장비의 광자 빔 6 MV와 10 MV 그리고 전자 빔 12 MeV에 대해 기준 조건하에서 흡수선량을 측정하였다. 이온함 간 선량 값의 최대 차이는 광자 빔 6 MV의 경우엔 2.4%, 10MV의 경우에 0.8%, 전자 빔 12 MeV의 경우엔 0.8%이었다. 6 MV에서의 큰 차이는 측정 과정에 문제가 없었다면, 동일한 ${\kappa}_{Q,Q_0}$ 값을 모든 이온함에 적용한 게 한 요인이 될 수 있다. 이는 또한 외부 독립검사가 왜 중요한지를 보여 주는 예라 하겠다.

웹 기반 고 에너지 방사선에 대한 흡수선량 교정 프로그램 개발 (Development of Web-based Dosimetry Calibration Program for High Energy Radiation)

  • 신동오;신동호;김성훈;박성용;서원섭;안희경;강진오;홍성언
    • 한국의학물리학회지:의학물리
    • /
    • 제16권3호
    • /
    • pp.116-124
    • /
    • 2005
  • 고 에너지 광자선과 전자선의 흡수선량 결정에 대한 표준측정법은 공기커마 교정인수를 바탕으로 한 방법이 널리 사용되고 있으나 복잡한 수식과 물리적인자의 불확실성 등으로 정확도 향상에 한계가 있다. 따라서 최근 국제원자력기구와 미국의학물리학회에서 물 흡수선량을 기반으로 표준측정법을 개발하였다. 본 연구는 국제원자력기구의 IAEA TRS-398 과 미국의학물리학회의 AAPM 7e-51 물 흡수선량 표준측정법에 대한 인터넷을 기반으로 하는 선량교정 프로그램을 개발하였다. 이 프로그램은 인터넷 온라인상에서 사용할 수 있도록 C$\#$ 언어를 사용하여 각각의 표준측정법의 절차에 따라 사용자의 편의를 고려하여 개발하였다. 사용자는 인터넷을 통해 기준점에서의 두 가지 절차서에 따른 물 흡수선량을 비교할 수 있으며, 국내 각 기관에서 수행된 선량교정의 추세를 이해하고 보다 쉽게 관리할 수 있게 하였다. 웹 기반 데이터베이스를 이용하여 차후 국내 실정에 적합한 물 흡수선량 표준에 기반을 둔 표준측정법을 개발하는데 기여할 것으로 기대된다

  • PDF

RADIATION DOSE TO HUMAN AND NON-HUMAN BIOTA IN THE REPUBLIC OF KOREA RESULTING FROM THE FUKUSHIMA NUCLEAR ACCIDENT

  • Keum, Dong-Kwon;Jun, In;Lim, Kwang-Muk;Choi, Yong-Ho
    • Nuclear Engineering and Technology
    • /
    • 제45권1호
    • /
    • pp.1-12
    • /
    • 2013
  • This paper describes the radiation doses to human and non-human biota in the Republic of Korea, as a result of the Fukushima nuclear accident. By using the measured airborne activity and ground deposition, the effective and thyroid doses of five human age groups (infant, 5 years, 10 years, 15 years and adult) were estimated by the ECOSYS code, and the whole body absorbed dose rate of the eight Korean reference animals and plants (RAPs) was estimated by the K-BIOTA (the Korean computer code to assess the risk of radioactivity to wildlife). The first-year effective and thyroid human doses ranged from 5.7E-5 mSv in the infant group to 2.0E-4 mSv in the 5 years group, and from 5.0E-4 mSv in the infant group to 3.4E-3 mSv in the 5 years group, respectively. The life-time (70 years) effective and thyroid human doses ranged from 1.5E-4 mSv in the infant group to 3.0E-4 mSv in the 5 years group, and from 6.0E-4 mSv in the infant group to 3.5E-3 mSv in the 5 years group, respectively. The estimated maximum whole body absorbed dose rate to the Korean RAPs was 6.7E-7 mGy/d for a snake living in soil (terrestrial biota), and 2.0E-5 mGy/d for freshwater fish (aquatic biota), both of which were far less than the generic dose criteria to protect biota from ionizing radiation. Also, the screening level assessment for ERICA's (Environmental Risks from Ionizing Contaminants: Assessments and management) limiting organisms showed that the risk quotient (RQ) for the estimated maximum soil and water activity was significantly less than unity for both the terrestrial and freshwater organisms. Conclusively, the radiological risk of the radioactivity released into the environment by the Fukushima nuclear accident to the public and the non-human biota in the republic of Korea is considered negligible.

자궁경부암 근접치료에서 A점과 H점을 이용한 치료계획 시 선량 비교 (Comparison of Dose When Prescribed to Point A and Point H for Brachytherapy in Cervical Cancer)

  • 강지형;김일환;황선붕;김웅;임형서;강진묵;김기환;이아람
    • 대한방사선치료학회지
    • /
    • 제24권2호
    • /
    • pp.61-66
    • /
    • 2012
  • 목 적: 본 연구에서는 자궁강 내 근접치료 시 ABS (American Brachytherapy Society)에서 권고한 H점(point H)을 이용한 치료계획을 수립해 보았고, 이를 A점(point A)에 처방한 치료계획과 비교하고자 한다. 대상 및 방법: 2010년 3월부터 2012년 1월까지 본원에 내원한 자궁경부암 환자 중 탄뎀(tandem)과 난형체(ovoid)를 이용해 고선량률 강내 근접치료(high dose rate intracavitary brachytherapy)를 시행한 103명을 대상으로 하였다. 치료계획은 Manchester System에 따라 A점, 방광 기준점, 직장 기준점을 지정하였고, ABS의 권고에 따라 H점을 지정하였다. 또한 임의로 S자 결장기준점과 질 기준점을 설정하였다. A점과 H점의 위치가 얼마나 차이가 나는지 살펴보았으며, H점에 100%의 선량을 처방하였을 때 A점에 들어가는 선량을 계산하였다. 그리고 A점과 H점에 각각 선량을 처방하였을 때 직장, 방광, S자 결장, 질 기준점에 들어가는 선량을 비교 분석하였다. 결 과: H점이 A점보다 미측에 있는 경우 A점의 상대선량은 기존의 A점이 아닌 H점에 처방하였을 때 더 적어지는 경향을 보였다. 방광 기준점과 직장 기준점, S자결장 기준점, 질 기준점에서의 상대선량은 H점이 두측에 있는 경우 H점에 처방하였을때의 선량이 A점에 처방하였을 때보다 크며, 미측에 있는 경우 더 적어지는 양상을 보였다. 결 론: H점이 A점보다 두측에 위치할수록 주변 장기의 흡수선량이 커지고, 미측에 위치할수록 주변 장기의 흡수선량이 적어지는 경향을 보였다. 그 선량 차이가 치료에 큰 영향을 미칠 정도는 아니지만, 두 치료계획에서의 선량 분포 및 주변 장기 흡수선량 차이가 크다면 두 점의 치료계획은 비교 또는 참고할 만한 가치가 있는 것으로 생각된다.

  • PDF

유리선량계를 이용한 저선량 방사선의 마우스 피폭선량 연구 (A Study on Mice Exposure Dose for Low-dose Gamma-irradiation Using Glass Dosimeter)

  • 노성진;김효진;김현;정동혁;손태건;김정기;양광모;남상희;강영록
    • Journal of Radiation Protection and Research
    • /
    • 제40권4호
    • /
    • pp.202-210
    • /
    • 2015
  • 저선량 조사는 낮은 선량을 지속적으로 장기간 조사시키기 때문에 조사되는 마우스들에 대한 선량분포를 정확히 알고 있어야만 한다. 본 연구는 저선량 방사선에 대한 생물학적 영향평가를 위하여 동남권원자력의학원 연구센터에 설치된 $^{137}Cs$ 조사장치에 대하여 마우스조사 실험 시 마우스에 원하고자 하는 선량을 전달하기 위한 방법에 대하여 연구를 수행하였다. 마우스에 원하고자 하는 정확한 선량을 전달하기 위하여 선원에 대하여 동일한 위치에 마우스 케이지 45개를 설치할 수 있는 아파트를 자체 개발하였으며, 개발된 마우스 아파트 시스템에 대한 선량평가를 하기 위하여 유리선량계(glass dosimeter)를 실험용 마우스 머리와 배에 삽입한 후 기존 조사 시스템과 자체 개발한 마우스 아파트 시스템에 대해 비교 선량평가를 수행하였다. 기존시스템의 조사방식에서 최대 42%의 선량차이를 보였으며 개발한 마우스 아파트 시스템은 6% 이내의 선량차이를 보였다. 본 연구를 통해 개발된 마우스 아파트를 활용한 저선량 방사선에 대한 생물학적 영향평가 연구는 전달하고자 하는 선량을 보다 정확하게 제공할 수 있으며, 생물학적 분석결과에 신뢰성을 확보할 수 있다.

Tungsten eyeball shield block의 임상적용에 관한 고찰 (Dosimetric characteristics of an independent collimator system using measurements performed quarter fields.)

  • 정덕양;이병구;황웅구
    • 대한방사선치료학회지
    • /
    • 제14권1호
    • /
    • pp.89-94
    • /
    • 2002
  • I. 목적 : Sebaceous gland carcinoma, Squamouse cell ca., basal cell ca., low grade MALToma 등에서 전자선을 이용하여 eyelid 치료시 안구의 선량은 될 수 있는 한 최소선량으로 관리되어야 한다. 그러나 upper나 lower eyelid 전부를 포함하는 조사면은 치료후 백내장등의 심각한 부작용을 만들어 낼 수 있다. 본원에서는 상용되는 Tungsten eyeball shielding block과 기존의 lead block에 의한 차폐시 안구의 선량을 비교하여 Tungsten eyeball shielding block의 유용성에 대해 평가해 보고자한다. 2. 재료 및 방법: 시판되고 있는 BOLX-I 물질을 이용하여 모형안구를 제작하고 안구의 6곳 주요지점을 선정한 후 TLD chip을 이용하여 주로 사용되는 6MeV와 9MeV electron beam의 선량을 측정, Tungsten eyeball shielding block과 lead block의 선량을 비교하였다. 3. 결과 : Tungsten eyeball shielding block의 사용이 안구의 주요 지점인 각막, 망막, 시신경부위의 선량을 lead block사용 때보다 $90\%$에서 $50\%$의 감소효과가 있었다. 4. 결론 : Tungsten eyeball shielding block은 6MeV 전자선 치료시 보다 뛰어난 차폐효과를 보여 임상에서의 유용성이 인정되었다. 그러나 안구에 삽입시 환자의 고통과 불쾌감을 줄일 수 있는 방안이 모색되어야 하는 숙제를 남겼다.

  • PDF

Dose rate measurement of Leksell Gamma Knife Perfexion using a 3D printed plastic scintillation dosimeter

  • Lee, Sangmin;Kim, Tae Hoon;Jeong, Jae Young;Son, Jaebum;Kim, Dong Geon;Cho, Gyu-Seok;Choi, Sang Hyoun;Chung, Hyun-Tai;Kim, Yong Kyun
    • Nuclear Engineering and Technology
    • /
    • 제52권10호
    • /
    • pp.2334-2338
    • /
    • 2020
  • In recent years, 3D printing technology has received significant research attention. Additionally, 3D printing technology is being applied to study radiation dosimeters of various materials. In this study, a plastic scintillator for 3D printing was developed in a laboratory and used to manufacture a plastic scintillation dosimeter (PSD) with a shape identical to that of the ionization chamber PTW31010. The 16-mm beam of Gamma Knife® Perfexion™ was irradiated to derive the absorbed dose rates of the PSD and PTW31010; they were subsequently compared with the dose rates of the treatment plan. The differences in the dose rates of the Gamma Knife treatment plan and the absorbed dose rates of PTW31010 were within 0.87%. The difference between the dose rates of the Gamma Knife treatment plan and the absorbed dose rates of the PSD were within 4.1%. A linear fit of the absorbed dose rates of four shots involving different dose rates and irradiation angles yielded an adjusted R-square value exceeding 0.9999. A total of 10 repeated measurements were conducted for the same shot to confirm its reproducibility, with a relative error of 0.56%.

선형가속기와 토모치료기를 이용한 전림프계의 방사선 치료시 선량분포에 관한 연구 (The Study of Dose Distribution according to the Using Linac and Tomotherapy on Total Lymphnode Irradiation)

  • 김영재;설광욱
    • 한국방사선학회논문지
    • /
    • 제7권4호
    • /
    • pp.285-291
    • /
    • 2013
  • 전림프계의 방사선치료시 선형가속기와 토모테라피를 이용하여 치료계획 수립 시 유용성을 확인하였다. 실험에 동의한 실험대상자 15명(남: 7명, 여: 8명)의 모의치료영상을 Somatom Sansation Open 16 channel으로 획득하여 이를 각각 의료용 선형가속기 치료계획 장치와 토모테라피 치료계획 장치로 전송하고 종양체적과 정상조직(전체 폐, 척수, 우측신장, 좌측신장)을 구분하여 종양조직에 750 cGy를 설정하여 종양조직의 선량 적합성, 정상조직의 선량흡수정도, 선량분포양상 그리고 선량체적곡선을 비교하여 평가하였으며 SPSS Ver. 18.0을 이용하여 대응표본검정을 실시하였다. 종양의 흡수선량 측정결과 토모테라피의 경우 $751.0{\pm}4.7cGy$, 선형가속기는 $746.9{\pm}14.1cGy$의 선량을 보였으며 이는 통계적으로 유의하지 않았다(p>0.05). 정상조직의 경우 전체 폐, 척수, 우측신장, 좌측신장에 입사되는 평균 방사선량은 토모테라피가 선형가속기보다 다소 낮은 방사선 흡수량을 보였다. 선량체적곡선에서 종양조직 및 정상조직 모두 적합한 양상을 보였다. 즉, 종양 및 정상조직의 선량흡수정도, 선량분포양상, 선량체적 곡선을 살펴본 결과 모두 적합한 치료효과비를 보인 것으로 판단되며 토모테라피 치료가 다소 높은 치료효율을 보였다. 토모테라피를 이용한 치료는 폐쇄형 치료공간과 긴 치료시간의 단점이 있기 때문에 오랜시간 자세재현이 불가능한 환자의 경우, 제한적으로 선형가속기 치료를 실시하여도 무방할 것으로 판단된다.