• Title/Summary/Keyword: Radiation Protection Product

Search Result 72, Processing Time 0.027 seconds

Review of National Diagnostic Reference Levels for Interventional Procedures

  • Lee, Min Young;Kwon, Jae;Ryu, Gang Woo;Kim, Ki Hoon;Nam, Hyung Woo;Kim, Kwang Pyo
    • Progress in Medical Physics
    • /
    • v.30 no.4
    • /
    • pp.75-88
    • /
    • 2019
  • Diagnostic reference level (DRL) is employed to optimize the radiation doses of patients. The objective of this study is to review the DRLs for interventional procedures in Korea and abroad. Literature review was performed to investigate radiation dose index and measurement methodology commonly used in DRL determination. Dose area product (DAP) and fluoroscopy time within each major procedure category were systematically abstracted and analyzed. A wide variation was found in the radiation dose. The DAP values and fluoroscopy times ranged 0.01-3,081 Gy·㎠ and 2-16,878 seconds for all the interventional procedures, 8.5-1,679 Gy·㎠ and 32-5,775 seconds for the transcatheter arterial chemoembolization (TACE), and 0.1-686 Gy·㎠ and 16-6,636 seconds for the transfemoral cerebral angiography (TFCA), respectively. The DRL values of the DAP and fluoroscopy time were 238 Gy·㎠ and 1,224 seconds for the TACE and 189 Gy·㎠ and 686 seconds for the TFCA, respectively. Generally, the DRLs of Korea were lower than those of other developed countries, except for the percutaneous transluminal angioplasty with stent in arteries of the lower extremity (LE PTA and stent), aneurysm coil embolization, and Hickman insertion procedures. The wide variation in the radiation doses of the different procedures suggests that more attention must be paid to reduce unnecessary radiation exposure from medical imaging. Furthermore, periodic nationwide survey of medical radiation exposures is necessary to optimize the patient dose for radiation protection, which will ultimately contribute to patient dose reduction and radiological safety.

Radiation-Induced IL(interleukin)-6 in Mice with Algin-Oligosaccharide Treatment (알긴산올리고당 처치 마우스의 방사선 유도 IL-6)

  • Choi, Seong-Kwan;Ji, Youn-Sang
    • Journal of radiological science and technology
    • /
    • v.33 no.4
    • /
    • pp.321-326
    • /
    • 2010
  • To examine the radioprotective effect of algin-oligosaccharide(AOS), radiation-induced IL(interleukin)-6 in mice treated with 3 Gy whole body irradiation once were examined. In the measurement of irradiation-induced IL-6, in comparison with the irradiation control group, in both small intestine and liver tissues of the group treated with algin-oligosaccharide for 7 days prior to irradiation, was suppressed IL-6 synthesis(p < 0.001). It is considered that the protection against radiation hazard by antioxydative reaction of algin-oligosaccharide results in down control of IL-6 value in experimental groups treated with algin-oligosaccharide. In conclusion, through our study, the fact that algin-oligosaccharide has irradiation protection effects was elucidated, and simultaneously, the possibility of the use of a natural product without chemical toxicity as an irradiation protection agent was confirmed.

Assessment of Post-LOCA Radiation Fields in Service Building Areas for Wolsong 2, 3, and 4 Nuclear Power Plants (월성 원자력 발전소 2,3,4호기에서의 LOCA 사고후 보조건물의 방사선장 평가)

  • Jin, Yung-Kwon;Kim, Yong-Il
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.1
    • /
    • pp.53-64
    • /
    • 1995
  • The radiation fields following the large loss of coolant accident (LOCA) have been assessed for the vital areas in the service building of Wolsong 2, 3, and 4 nuclear power plants. The ORIGEN2 code was used in calculating the fission product inventories in the fuel. The source terms were based upon the activity released following the dual failure accident scenario, i.e., a LOCA followed by impaired emergency core cooling (ECC). Configurations of the reactor building, the service building, and the ECC system were constructed for the QAD-CG calculations. The dose rates and the time-integrated doses were calculated for the time period of upto 90 days after the accident. The results showed that the radiation fields in the vital access areas were found to be sufficiently low. Some areas however showed relatively high radiation fields that may require limited access.

  • PDF

A Study on the Radioactive Products of Components in Proton Accelerator on Short Term Usage Using Computed Simulation (몬테칼로 시뮬레이션을 활용한 양성자가속기 단기사용 시 구성품의 방사화 평가)

  • Bae, Sang-Il;Kim, Jung-Hoon
    • Journal of radiological science and technology
    • /
    • v.43 no.5
    • /
    • pp.389-395
    • /
    • 2020
  • The evaluation of radioactivated components of heavy-ion accelerator facilities affects the safety of radiation management and the exposure dose for workers. and this is an important issue when predicting the disposal cost of waste during maintenance and dismantling of accelerator facilities. In this study, the FLUKA code was used to simulate the proton treatment device nozzle and classify the radio-nuclides and total radioactivity generated by each component over a short period of time. The source term was evaluated using NIST reference beam data, and the neutron flux generated for each component was calculated using the evaluated beam data. Radioactive isotopes caused by generated neutrons were compared and evaluated using nuclide information from the International Radiation Protection Association and the Korea Radioisotope association. Most of the nuclides produced form of beta rays and electron capture, and short-lived nuclides dominated. However, In the case of 54Mn, which is a radioactive product of iron, the effect of gamma rays should be considered. In the case of tritium generated from a material with a low atomic number, it is considered that handling care should be taken due to its long half-life.

Rapid Screening of Naturally Occurring Radioactive Nuclides (238U, 232Th) in Raw Materials and By-Products Samples Using XRF

  • Park, Ji-Young;Lim, Jong-Myoung;Ji, Young-Yong;Lim, Chung-Sup;Jang, Byung-Uck;Chung, Kun Ho;Lee, Wanno;Kang, Mun-Ja
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.4
    • /
    • pp.359-367
    • /
    • 2016
  • Background: As new legislation has come into force implementing radiation safety management for the use of naturally occurring radioactive materials (NORM), it is necessary to establish a rapid and accurate measurement technique. Measurement of $^{238}U$ and $^{232}Th$ using conventional methods encounter the most significant difficulties for pretreatment (e.g., purification, speciation, and dilution/enrichment) or require time-consuming processes. Therefore, in this study, the applicability of ED-XRF as a non-destructive and rapid screening method was validated for raw materials and by-product samples. Materials and Methods: A series of experiments was conducted to test the applicability for rapid screening of XRF measurement to determine activity of $^{238}U$ and $^{232}Th$ based on certified reference materials (e.g., soil, rock, phosphorus rock, bauxite, zircon, and coal ash) and NORM samples commercially used in Korea. Statistical methods were used to compare the analytical results of ED-XRF to those of certified values of certified reference materials (CRM) and inductively coupled plasma mass spectrometry (ICP-MS). Results and Discussion: Results of the XRF measurement for $^{238}U$ and $^{232}Th$ showed under 20% relative error and standard deviation. The results of the U-test were statistically significant except for the case of U in coal fly ash samples. In addition, analytical results of $^{238}U$ and $^{232}Th$ in the raw material and by-product samples using XRF and the analytical results of those using ICP-MS ($R^2{\geq}0.95$) were consistent with each other. Thus, the analytical results rapidly derived using ED-XRF were fairly reliable. Conclusion: Based on the validation results, it can be concluded that the ED-XRF analysis may be applied to rapid screening of radioactivities ($^{238}U$ and $^{232}Th$) in NORM samples.

A Comparative Study of Image Quality and Radiation Dose according to Variable Added Filter and Radiation Exposure in Diagnostic X-Ray Radiography (진단용 X-선 촬영시 부가 필터 및 노출의 변화에 따른 피폭선량 및 영상 화질 비교 연구)

  • Choi, Nam-Gil;Seong, Ho-Jin;Jeon, Joo-Seop;Kim, Youn-Hyun;Seong, Dong-Ook
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.1
    • /
    • pp.25-34
    • /
    • 2012
  • To know which parameters were acceptable for achieving lowest radiation exposure to the patients and highest image quality at the diagnostic X-ray radiography, we measured the patient radiation dose and image quality in transmitted PACS (Picture Archiving and Communication System) at variable combinations of the added filters. As a result, the Dose Area Product (DAP: $mGy{\cdot}cm^2$) and Entrance Surface Doses (ESDs: $mGy$) was lowest at 1 mmAl + 0.2 mmCu and highest at 0 mmAl. The histogram of the image quality by transmitted PACS was not significantly different at variable combinations of exposure parameters on the MATLAB. In conclusion, this study can be helpful for expecting radiation dose-exposure and control exposure parameters for the diagnostic X-ray radiography.

Protective Effects of Paeonia japonica against Radiation-induced Damage (방사선 장해에 대한 백작약의 방호효과)

  • Oh, Heon;Park, Hae-Ran;Jeong, Ill-Yun;Kim, Sung-Ho;Jo, Sung-Kee
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.3
    • /
    • pp.181-188
    • /
    • 2002
  • We investigated the effect of Paeonia japonica (PJ) on radiation-induced oxidative damage to macromolecules in vitro and in vivo. The PJ reduced the tail moment (TM) which was a marker of DNA strand break in single-cell gel electrophoresis (SCGE; comet assay) in the human peripheral blood lymphocytes. Lipid peroxidation in the liver of the ICR mouse, measured as malondialdehyde (MDA), was also reduced by PJ administration. Ethanol fraction of PJ was more effective than polysaccharide fraction of that on reduction of TM in SCGE and lipid peroxidation. Also, Their activities to scavenge DPPH radicals and hydroxyl radicals were observed in vitro, and the activities were due to its ethanol fraction. It is plausible that scavenging of flee radicals by PJ extract may have played an important role in providing the protection against the radiation-induced damage. These results indicated that Paeonia japonica might be a useful radioprotector, especially since it is a relatively nontoxic natural product.

Impurity Analysis of Domestic $MnSO_4{\cdot}H_2O$ Introduced to Manganese Bath Method (망간용액조방법에 도입되는 국산 황산망간중의 불순물 분석)

  • Hwang, Sun-Tae;Lee, Kyung-Ju;Choi, Kil-Oung;Lee, Kwang-Woo;Woo, Jin-Chun;Lee, Ki-Bum
    • Journal of Radiation Protection and Research
    • /
    • v.12 no.1
    • /
    • pp.48-53
    • /
    • 1987
  • The manganous sulphate bath method is widely used for measurements of neutron source strength. In this study, the analytical chemistry method based on the argon supported inductively coupled plasmas emission spectrometry was used for examining the impurity contents of domestic $MnSO_4{\cdot}H_2O$ the product of Chemical Industry, to induce $^{55}Mn(n,{\gamma})^{56}$ Mn reactions. From the analytical results, mainly potassium, cobalt, and zinc as well as trace amounts of cadmium, lithium, etc. have turned out to be the relevant impurities absorbing the neutrons, and the fraction of neutrons absorbed by the total impurities was calculated. The value obtained was about 1.37% of the neutrons captured by manganese.

  • PDF

The Radioprotective Effects of Rhizomata Herbs (대표적 근경류 생약의 방사선 방호효과)

  • Kim, Sung-Ho;Jo, Sung-Kee;Kwon, Oh-Deog
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.1
    • /
    • pp.13-18
    • /
    • 2001
  • We performed this study to determine the effect of Baizhu (Atractylodes japonica), Chuanxiong (Cnidium officinale), Shanyao (Discorea japonica) and Shengma (Cimicifuga heracleifolia), as Oriental rhizomata herbs, on jejunal crypt survival, endogenous spleen colony formation and apoptosis in jejunal crypt cells of mice irradiated with high and low dose of ${\gamma}$-radiation. Shengma was effective in intestinal crypt survival(p<0.05). The frequency of radiation induced apoptosis was also reduced by pretreatment with Chuanxiong and Shengma(p<0.05). Although the mechanisms of this effort remain to be elucidated, these results indicated that Shengma might be a useful radioprotector, especially since it is a relatively nontoxic natural product.

  • PDF

A Study about The Effect of Radiation on Particle-Seeding Hydrogen Flame (고체입자의 수소화염에 있어서의 열복사에 관한 연구)

  • Choi, Joon-Won;Baek, Seung-Wook;Kim, Jung-Ju;Kim, Han-Seok
    • 한국연소학회:학술대회논문집
    • /
    • 2002.11a
    • /
    • pp.129-139
    • /
    • 2002
  • From the view of the environmental protection against the use of fossil fuels, a great of efforts have been exerted to find an alternative energy source. Hydrogen may become an alternative. However the product species of the hydrogen flame is only $H_2O$, which emits only non-luminous radiation so the radiation from it is much smaller than that for a hydrocarbon flame. In this study, the authors designed and fabricated a laboratory scale test furnace to study thermal characteristics of hydrogen-air diffusion flame. In addition, the effects of addition of reacting as well as non-reacting solid particles were experimentally investigated. Among the total heat flux to the wall, about 75% was occupied by radiation while 25 % by convection. When the aluminum oxide ($Al_2O_3$) particles were added, the radiative heat flux was reduced due to heat blockage effects. On the other hand, the total as well as the radiative heat flux was increased when the carbon particles were seeded, since the overall temperature increased. The effects of swirl and excess air ratio were also examined.

  • PDF