• Title/Summary/Keyword: Radiation Power

Search Result 1,935, Processing Time 0.029 seconds

Application of the Detection of External Contamination on Radiation Workers for Bed Type Whole Body Counting Using Monte Carlo Method (몬테카를로 방법을 적용한 bed type 전신계측기의 방사선작업종사자 외부오염 검출 응용)

  • Kim, Jeong-In;Lee, Byoung-Il
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.4
    • /
    • pp.242-245
    • /
    • 2013
  • Monte Carlo method was applied to discriminate the external contamination on radiation workers in nuclear power plants for internal dose assessment generally used with a bed type scanning detector whole body counter. Korean voxel model with internal contamination was used to estimate the detection patterns of whole body scanning. Also, the BOMAB model with various external contamination was assumed to compare with detection of radionuclides inside the human body. From the comparison of detection efficiency between front and back side up, external contamination was easily distinguished.

Understanding radiation effects in SRAM-based field programmable gate arrays for implementing instrumentation and control systems of nuclear power plants

  • Nidhin, T.S.;Bhattacharyya, Anindya;Behera, R.P.;Jayanthi, T.;Velusamy, K.
    • Nuclear Engineering and Technology
    • /
    • v.49 no.8
    • /
    • pp.1589-1599
    • /
    • 2017
  • Field programmable gate arrays (FPGAs) are getting more attention in safety-related and safety-critical application development of nuclear power plant instrumentation and control systems. The high logic density and advancements in architectural features make static random access memory (SRAM)-based FPGAs suitable for complex design implementations. Devices deployed in the nuclear environment face radiation particle strike that causes transient and permanent failures. The major reasons for failures are total ionization dose effects, displacement damage dose effects, and single event effects. Different from the case of space applications, soft errors are the major concern in terrestrial applications. In this article, a review of radiation effects on FPGAs is presented, especially soft errors in SRAM-based FPGAs. Single event upset (SEU) shows a high probability of error in the dependable application development in FPGAs. This survey covers the main sources of radiation and its effects on FPGAs, with emphasis on SEUs as well as on the measurement of radiation upset sensitivity and irradiation experimental results at various facilities. This article also presents a comparison between the major SEU mitigation techniques in the configuration memory and user logics of SRAM-based FPGAs.

Development of Unmanned Remote Radiation Detection Module (무인 원격 방사선 검출 모듈 개발)

  • Chang, Bo-Seok
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.795-801
    • /
    • 2021
  • The designed drone-based unmanned remote radiation detection module was developed according to the needs of the nuclear power plant decommissioning workshop. Using the Geiger-Mueller tube sensitive to low-level radiation measurement, It was manufactured to measure the amount of radiation leaking into and out of the containment vessel. The drone-based radiation detection module weighs less than 200g, It can be operated inside and outside the containment vessel of a nuclear power plant. To check the performance of the designed equipment, a performance evaluation test was conducted with reference to the international standard (IEC-60864). The stability of the radiation detection module designed to meet the needs of the field the statistical rate of change by repeated measurements in the rate of change experiment to evaluate the measurement accuracy was ±4.6%. The accuracy ±7.3% in the linearity experiment to evaluate the dose rate dependence, the linear The figure satisfies the international performance evaluation standard of ±3.5%. The radiation detection module developed in this study is a customized equipment for a nuclear power plant dismantling workshop. It will be helpful for accurate measurement of space dose rate and safety management of radiation worksites in sites with a lot of radiation dust.

Radiation risk perception and its associated factors among residents living near nuclear power plants: A nationwide survey in Korea

  • Sung, Hyoju;Kim, Jung Un;Lee, Dalnim;Jin, Young Woo;Jo, Hyemi;Jun, Jae Kwan;Park, Sunhoo;Seo, Songwon
    • Nuclear Engineering and Technology
    • /
    • v.54 no.4
    • /
    • pp.1295-1300
    • /
    • 2022
  • There has been increased interest in researching risk perception of radiation to implement successful risk communication, particularly given the recent worldwide nuclear policy movement regarding nuclear energy. This study aimed to investigate characteristics of risk perception among residents living near normally operating nuclear power plants in South Korea by identifying factors associated with risk perception. A survey was conducted with face-to-face interviews for 1200 residents aged 20e84 years by gender- and age-stratified random sampling. Risk perception was associated with trust perception in nuclear safety, but was not highly correlated with benefit perception for utilizing nuclear power. Relatively high risk perception was observed in women, older age groups, and residents not having experience of nuclear-related education or work. This association remained after adjusting for other factors including benefit perception, trust perception, and psychological distress. In addition to these individual characteristics, risk perception was also associated with a residential district's own unique context, indicating that a strategy of risk communication should be developed differently for residents facing nuclear-related circumstances. Given that risk perception can be changed, depending on social values such as safety culture and economic setting, further studies are required to understand the changing characteristics of radiation risk perception.

Second intercomparison on electron paramagnetic resonance (EPR) retrospective dosimetry in Korea using hydroxyapatite

  • HyoJin Kim;Jae Seok Kim;Byeong Ryong Park;Seongjae Jang;Han-Ki Jang;Ki-Taek Han;Hoon Choi;Jeongin Kim;In Jung Kim;Yunho Kim;Wi-Ho Ha;Jungil Lee;Yeong-Rok Kang
    • Nuclear Engineering and Technology
    • /
    • v.55 no.12
    • /
    • pp.4576-4582
    • /
    • 2023
  • The Korea retrospective dosimetry (KREDOS)-electron paramagnetic resonance (EPR) group undertook an intercomparison investigation utilizing hydroxyapatite. This analysis involved four institutions: the Korea Institute of Radiological and Medical Sciences, Dongnam Institute of Radiological and Medical Sciences, Korean Association for Radiation Application, and Radiation Health Institute of Korea Hydro & Nuclear Power. Following the irradiation of the hydroxyapatite sample, the recorded build-up was analyzed. To validate the reliability of the EPR dosimetry findings and enhance its operational performance, a hydroxyapatite dose-response curve was plotted and dosimetry was performed for a blind sample. The proficiency of each laboratory was assessed by employing an interlaboratory comparison methodology. This involved a comparative analysis of the measurement results by calculating the relative bias, z-score, and En value. The results submitted by the participating laboratories demonstrated satisfactory ratings for doses of 1.006, 3.999, and 6.993 Gy. Following the second intercomparison, efforts to optimize their hydroxyapatite-EPR dosimetry systems are underway in the participating laboratories. The current assessment of hydroxyapatite dose yielded the foundational data required to establish the parameters of dental dosimetry. In future, the third intercomparison experiment will be conducted for exploring other materials.

Comparison Study of Maximum Power Point Tracking Control with Changing of Radiation (일사량 변화에 대한 최대전력점 추종 제어의 비교 연구)

  • Choi, Jung-Sik;Ko, Jae-Sub;Chung, Dong-Hwa
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.6
    • /
    • pp.1075-1082
    • /
    • 2010
  • This paper analyzes a operating characteristic for maximum power point tracking (MPPT) of photovoltaic generation system. MPPT methods are used to maximize PV array output power by tracking maximum power point(MPP) continuously. To increase the output efficiency of PV system, it is important to have more efficient MPPT. MPPT algorithm is widely used the control method such as the perturbation and observation(PO) method, incremental conductance(IC) method and constant voltage(CV) method. In case of the radiation is changed, this paper proposes a response characteristic with MPPT control algorithms. Also, it proposes the direct for a novel MPPT control algorithm development through the analyzed data, hereby proves the effectiveness of this paper.

The study on Measuring of Environmental Radioactivity in the Vicinity of Yonggwang Nuclear Power Plant (영광 원자력 발전소 주변 환경 방사능 측정에 관한 연구)

  • 박종섭
    • Economic and Environmental Geology
    • /
    • v.32 no.3
    • /
    • pp.273-280
    • /
    • 1999
  • In order to protect inhabitans' health and to collect data for prediction of the effcts from accidental emission of rasioactive materials from nuclear power plant, exposed dose rate be monitored within the limit dose rate. This research was carried out to investigate the accumulation of environmental radioactivity around Younggwang Nuclear Power Plant, and to infer and in infer and assay the additional exposed dose rate of inhabitants in Younggwang site from the operation of nuclear plant operation. External radiation dose rate, radiation environmental samples, and exposed dose rate of inhabitants in Younggwang site were investigated for estimaing environment activity in the vicinity of the nuclear power plant area. For the external radiation dose rate, the result showed that range of normal variation was found and any artificial radioisotope was not deteted in the analysis of environmental samples. Exposed dose rate of inhabitants was lower than 0.4% of the limit value of ICRP and it may be concluded that there was no effect on inhabitants and environment from the operation of nuclear power plant.

  • PDF

Field tests of the radiation detectors for environmental radiation monitoring around KORI nuclear power plants (고리원자력 주변 환경방사선 감시를 위한 방사선 측정기의 현장 성능 시험)

  • 최성수;신대용;조규성;하달규
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1371-1374
    • /
    • 1997
  • We had developed the on-line environmental monitoring system which has installed around Kori Nuclear Power Plants and will be taken the place of the existing system. The system consists of a main computer and 11 sets of radiation monitoring post equipments. Nal(Tl) scintillation detectro was adopted in addition to ion-chamber detector and implemented with DCU(Dose Conversion Unit) and SCA(Single Channel Analyzer). Compared with the existing system, it has revised feature in the radiation measurements which are detection of artificial radioactivity and 2-ways of the radiatiion detectors. The field test trsults show that the developed radiation detecting equipments can measure environmental radiation withn 5.0% of the theoretical value.

  • PDF

A Methodology of Dual Gate MOSFET Dosimeter with Compensated Temperature Sensitivity

  • Lho, Young-Hwan
    • Journal of IKEEE
    • /
    • v.15 no.2
    • /
    • pp.143-148
    • /
    • 2011
  • MOS (Metal-Oxide Semconductor) devices among the most sensistive of all semiconductors to radiation, in particular ionizing radiation, showing much change even after a relatively low dose. The necessity of a radiation dosimeter robust enough for the working environment has increased in the fields of aerospace, radio-therapy, atomic power plant facilities, and other places where radiation exists. The power MOSFET (Metal-Oxide Semiconductor Field-Effect Transistor) has been tested for use as a gamma radiation dosimeter by measuring the variation of threshold voltage based on the quantity of dose, and a maximum total dose of 30 krad exposed to a $^{60}Co$ ${\gamma}$-radiation source, which is sensitive to environment parameters such as temperature. The gate oxide structures give the main influence on the changes in the electrical characteristics affected by irradiation. The variation of threshold voltage on the operating temperature has caused errors, and needs calibration. These effects can be overcome by adjusting gate oxide thickness and implanting impurity at the surface of well region in MOSFET.

Process monitoring of laser welding using chromatic filtering of thermal radiation (열복사의 색수차 공간여과를 이용한 레이저용접 감시기술)

  • 백성훈;박승규;김민석;정진만;김철중
    • Laser Solutions
    • /
    • v.2 no.2
    • /
    • pp.18-26
    • /
    • 1999
  • An innovative real-time weld monitoring technique using chromatic filtering of the thermal radiation from a weld pool is developed. The thermal radiation from the weld pool is focused on an aperture and the transmitted thermal radiation is monitored at two wavelengths with high-speed single-element detectors. Due to the chromatic aberration introduced in the focusing optics, the transmittance curve of thermal radiation varies by the wavelength. Owing to this difference in the transmittance, the local variation of thermal radiation from the weld pool can be monitored by processing the two spectroscopic signals from two detectors. In this paper, the algorithms to monitor the laser power on the weld specimen and the focus shift we investigated and the performances of laser power and focus monitoring are shown for a pulsed Nd:YAG laser welding. The monitoring of the weld pool size variation is also discussed.

  • PDF