• Title/Summary/Keyword: Radiation Database

Search Result 158, Processing Time 0.034 seconds

A Study on Radiation Risk Recognition Aided System Visualizing Risk Information by CG

  • Katagiri, M.;Tuzuki, Y.;Sawamura, S.;Aoki, Y.
    • Proceedings of the IEEK Conference
    • /
    • 2002.07a
    • /
    • pp.425-428
    • /
    • 2002
  • The technology of Computer Graphics (CG) has been in great progress for almost 20 years and has proven to be a valuable tool for a broad variety of fields, including nuclear engineering. To work in any hazardous environment for example radiation field is particularly challenging because the danger is not always visually apparent. In this study as the application of CG to nuclear engineering field, we proposed to develop a radiation risk recognition aided system in which various radiation information; radiation risks, radiation distribution, hazard information and so on, were visualized by CG. The system used the server and client system. In the server there were two parts; one (main-server) was the database part having various data and the other (sub-server) was the visualization part visualizing the human phantom by POV-Ray. In the client there was the input and output part. The outputs from the system were various radiation information represented by coloring, circle graph and line graph intuitionally. The system is useful for a broad range of activities including radiation protection, radiation management, dose minimization, and demonstration to the public.

  • PDF

A Genome-wide Approach for Functional Analysis Using Rice Mutant

  • Yim, Won-Cheol;Kim, Dong-Sub;Moon, Jun-Cheol;Jang, Cheol-Seong;Lee, Byung-Moo
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.54 no.3
    • /
    • pp.332-338
    • /
    • 2009
  • Rapid extension of genomic database leads to the remarkable advance of functional genomics. This study proposes a novel methodology of functional analysis using 5-methyltrytophan (5 MT) mutant together with their 2-DE analysis and public microarray database. A total of 24 proteins was changed in 5 MT mutant and four remarkably different expressed proteins were identified. Among them, three spots were converted to Affymetrix probe. A total of 155 microarray samples from Gene Expression Omnibus (GEO) in NCBI was retrieved and followed by constructing gene co-expression networks over a broad range of biological issues through Self-Organising Tree Algorithm. Three co-expressing gene clusters were retrieved and each functional categorization with differential expression pattern was exhibited from 5 MT resistance mutant rice. It was indicated new co-expression networks in the mutant. This study suggests that on investigating possibility which correspond 2-DE to microarray database with their full potential.

Database Construction of High-resolution Daily Meteorological and Climatological Data Using NCAM-LAMP: Sunshine Hour Data (NCAM-LAMP를 이용한 고해상도 일단위 기상기후 DB 구축: 일조시간 자료를 중심으로)

  • Lee, Su-Jung;Lee, Seung-Jae;Koo, Ja-seob
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.22 no.3
    • /
    • pp.135-143
    • /
    • 2020
  • Shortwave radiation and sunshine hours (SHOUR) are important variables having many applications, including crop growth. However, observational data for these variables have low horizontal resolution, rendering its application to related research and decision making on f arming practices challenging. In the present study, hourly solar radiation data were physically generated using the Land-Atmosphere Modeling Package (LAMP) at the National Center f or Agro-Meteorology, and then daily SHOUR fields were calculated through statistical downscaling. After data quality evaluation, including case studies, the SHOUR data were added to the existing publically accessible LAMP daily database. The LAMP daily dataset, newly updated with SHOUR, has been provided operationally as input data to the "Gyeonggi-do Agricultural Drought Prediction System," which predicts agricultural weather disasters and field crop growth status.

Irradiation Detection in Korean Traditional Soybean-Based Fermented Powdered Sauces: Data for Establishing a Database for Regulation of Irradiated Foods

  • Choi, In-Duck;Kim, Byeong-Keun;Song, Hyun-Pa;Byun, Myung-Woo;Kim, Myung-Cheol;Lee, Jong-Oak;Lee, Ho-Joon;Kim, Dong-Ho
    • Preventive Nutrition and Food Science
    • /
    • v.10 no.1
    • /
    • pp.29-33
    • /
    • 2005
  • To facilitate establishing regulations for irradiated foods, Korean traditional soybean-based fermented powdered doenjang (PD), kanjang (PK), kochujang (PKC) and chungkukjang (PC) were irradiated at 1, 3, 5 and 7 kGy, and subjected to irradiation detection analyses as part of establishing a database for detecting irradiated foods. Photostimulated luminescence (PSL) and electron spin resonance (ESR) were applied as the detection methods. Using PSL analysis, the irradiated PD, PK and PKC could be easily distinguished from the non-irradiated ones, while irradiation of the PC at 5 kGy or higher was detectable. The ESR spectra of the irradiated PD, PK and PKC exhibited symmetrical multiplet lines, which might be induced from the crystalline sugar, whereas, the PC showed a single signal at the paramagnetic centers. The signal intensity increased with incremental increases of irradiation doses distinguishing the irradiated samples from the control. In addition, the peak height also revealed that irradiation induced an increment in the intensity of single and/or multiplet lines of the ESR signals, resulting in clear confirmation of irradiation. Thus, the data from this study could be used as references for detecting irradiated soybean-based fermented powdered sauces.

The Optimization Experience of Occupational Exposure during Unclear Power Plant Outage (원자력발전소 계획예방정비 기간중 피폭최적화 경험)

  • Song, Young-Il;Kim, Hyung-Jin;Park, Hun-Kook;Kim, Hee-Geun
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.2
    • /
    • pp.145-154
    • /
    • 2003
  • By optimizing the radiation protection the collective dose and individual dose could be reduced during YGN #4 $5^{th}$ outage in 2001. The collective doses for the two high radiation jobs decreased to 85% and 65% of expected doses. The proportion of workers with low dose (below 1mSv) exposure increased 4% while the proportion of workers with over 3mSv and 5mSv exposure are decreased to 2%, 1% respectively. But none is exposed over 8mSv for the annual dose. To aid decision of utilizing the robot, cost- benefit analysis was performed and reasonable point was proposed to use the robot. For the first time job, repeated ALARA meeting and mock up training were implemented to set up working procedure by identifying the trouble. To easily set up standard procedure, mockup process was videotaped and reviewed during ALARA meeting. Monitoring is a good approach to chase radiological working condition such as working time, dose rate. behavior of workers, especially for high radiation work. Those data were estimated and adjusted from the stage of work planning to mock up. At the stage of actual work the monitoring data were compared to the estimation and recorded to database. This database will not only be used as a powerful tool for dose optimization at the following outage but also as a guideline to dose constraint set up for optimization for each specific situation.

Provision of a Draft Version for Standard Classification Structure for Information of Radiation Technologies through Analyzing Their Information and Derivation of Its Applicable Requirements to the Information System (방사선 기술정보 분석을 통한 정보표준분류체계(안) 마련 및 시스템 적용요건 도출)

  • Jang, Sol-Ah;Kim, Joo Yeon;Yoo, Ji Yup;Shin, Woo Ho;Park, Tai Jin;Song, Myung-jae
    • Journal of Radiation Industry
    • /
    • v.9 no.1
    • /
    • pp.29-35
    • /
    • 2015
  • Radiation technology is the one for developing new products or processes by applying radiation or for creating new functions in industry, research and medical fields, and its application is increasing consistently. For securing an advanced technology competitiveness, it is required to create a new added value by information consumer through providing an efficient system for supporting information, which is the infrastructure for research and development, contributed to its collection, analysis and use with a rapidity and structure in addition to some direct research and development. Provision of the management structure for information resources is especially crucial for efficient operating the system for supporting information in radiation technology, and then a standard classification structure of information must be first developed as the system for supporting information will be constructed. The standard classification structure has been analyzed by reviewing the definition of information resources in radiation technology, and those classification structures in similar systems operated by institute in radiation and other scientific fields. And, a draft version of the standard classification structure has been then provided as 7 large, 25 medium and 71 small classifications, respectively. The standard classification structure in radiation technology will be developed in 2015 through reviewing this draft version and experts' opinion. Finally, developed classification structure will be applied to the system for supporting information by considering the plan for constructing this system and database, and requirements for designing the system. Furthermore, this structure will be designed in the system for searching information by working to the individual need of information consumers.

Organ dose reconstruction for the radiation epidemiological study of Korean radiation workers: The first dose evaluation for the Korean Radiation Worker Study (KRWS)

  • Tae-Eun Kwon;Areum Jeong;Wi-Ho Ha;Dalnim Lee;Songwon Seo;Junik Cho;Euidam Kim;Yoonsun Chung;Sunhoo Park
    • Nuclear Engineering and Technology
    • /
    • v.55 no.2
    • /
    • pp.725-733
    • /
    • 2023
  • The Korea Institute of Radiological and Medical Sciences has started a radiation epidemiological study, titled "Korean Radiation Worker Study," to evaluate the health effects of occupational exposure to radiation. As a part of this study, we investigated the methodologies and results of reconstructing organ-specific absorbed doses based on personal dose equivalent, Hp(10), reported from 1984 to 2019 for 20,605 Korean radiation workers. For the organ dose reconstruction, representative exposure scenarios (i.e., radiation energy and exposure geometry) were first determined according to occupational groups, and dose coefficients for converting Hp(10) to organ absorbed doses were then appropriately taken based on the exposure scenarios. Individual annual doses and individual cumulative doses were reconstructed for 27 organs, and the highest values were observed in the thyroid doses (on average 0.77 mGy/y and 10.47 mGy, respectively). Mean values of individual cumulative absorbed doses for the red bone marrow, colon, and lungs were 7.83, 8.78, and 8.43 mSv, respectively. Most of the organ doses were maximum for industrial radiographers, followed by nuclear power plant workers, medical workers, and other facility workers. The organ dose database established in this study will be utilized for organ-specific risk estimation in the Korean Radiation Worker Study.

A Comprehensive Computer Program for Monitor Unit Calculation and Beam Data Management: Independent Verification of Radiation Treatment Planning Systems (방사선치료계획시스템의 독립적 검증을 위한 선량 계산 및 빔데이터 관리 프로그램)

  • Kim, Hee-Jung;Park, Yang-Kyun;Park, Jong-Min;Choi, Chang-Heon;Kim, Jung-In;Lee, Sang-Won;Oh, Heon-Jin;Lim, Chun-Il;Kim, Il-Han;Ye, Sung-Joon
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.231-240
    • /
    • 2008
  • We developed a user-friendly program to independently verify monitor units (MUs) calculated by radiation treatment planning systems (RTPS), as well as to manage beam database in clinic. The off-axis factor, beam hardening effect, inhomogeneity correction, and the different depth correction were incorporated into the program algorithm to improve the accuracy in calculated MUs. A beam database in the program was supposed to use measured data from routine quality assurance (QA) processes for timely update. To enhance user's convenience, a graphic user interface (GUI) was developed by using Visual Basic for Application. In order to evaluate the accuracy of the program for various treatment conditions, the MU comparisons were made for 213 cases of phantom and for 108 cases of 17 patients treated by 3D conformal radiation therapy. The MUs calculated by the program and calculated by the RTPS showed a fair agreement within ${\pm}3%$ for the phantom and ${\pm}5%$ for the patient, except for the cases of extreme inhomogeneity. By using Visual Basic for Application and Microsoft Excel worksheet interface, the program can automatically generate beam data book for clinical reference and the comparison template for the beam data management. The program developed in this study can be used to verify the accuracy of RTPS for various treatment conditions and thus can be used as a tool of routine RTPS QA, as well as independent MU checks. In addition, its beam database management interface can update beam data periodically and thus can be used to monitor multiple beam databases efficiently.

  • PDF

DataBase system construction for the study of radiation hardened electronic devices using pulse radiation (펄스방사선을 이용한 내방사선 연구 DB 구축)

  • Ko, Seong-Gon;Oh, Seung-Chan;Hwang, Young-Gwan;Jeong, Sang-Hun;Lee, Nam-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.778-781
    • /
    • 2012
  • The electronic element the damage occurs with radiation being bombed. In order applies in the artificial satellite or the space ship therefore from the within has radiation introspection the use of the radiation electronic element is essential. Transient radiation tests performed for the first time in Korea evaluation data database (DB) was constructed to. Web-based materials in the DB is designed to be able to search and update, and existing foreign (NASA, ESA) for a total of 695 species, including public sources of data has been entered. Search DB than the existing foreign DB is an efficient and practical.

  • PDF

Estimation of Future Trend for Solar Radiation Data Management (일사량 데이터 관리를 위한 미래 변화 추이 예측)

  • Oh, In-Bae;Lee, Bong-Keun;Ahn, Yoon-Ae
    • The Journal of the Korea Contents Association
    • /
    • v.7 no.12
    • /
    • pp.218-230
    • /
    • 2007
  • Measured values of solar radiation data have a characteristic that they change almost by the minute, so original data can be massive. Therefore, we need to construct a database which stores and manages history data of solar radiation data systematically. A study of an estimation method of the future change trend is also required. In this paper, we present a data structure in order to store history data of solar radiation data and propose an estimation method for the change trend of solar radiation that applies to a time-series decomposition method. Also, we present the results of experiments based on measured data from 20 domestic cities in Korea.