• Title/Summary/Keyword: RTN

Search Result 35, Processing Time 0.021 seconds

C-V Characteristics of MOS Devices by Rapid Thermal Nitridation(RTN) (RTN에 의해 제작된 MOS 소자의 C-V 특성)

  • Chang, Eui-Goo;Choi, Won-Eun;Yoon, Dohn-Young;Lee, Oh-Sung;Kim, Sang-Yong
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.785-787
    • /
    • 1988
  • The capacitance-voltage (C-V) chracteristics of thin nitrided thermal oxides prepared by rapid termal nitridation(RTN) have been studied. The threshold voltages were calculated using C-V measurement and found to vary as the concentration of acceptor and the thickness of oxynitride. When the Si02 films were annealed in NH3 a decrease in the positive oxide charge due to Si-N bond was observed. In the case applied frequency is high and low, the high frequency depletion capacitance was higher than that of low frequency, which is indicative of high frequency surface conduction by mobile surface charge.

  • PDF

A Technique to Circumvent V-shaped Deconvolution Error for Time-dependent SRAM Margin Analyses

  • Somha, Worawit;Yamauchi, Hiroyuki;Yuyu, Ma
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.2 no.4
    • /
    • pp.216-225
    • /
    • 2013
  • This paper discusses the issues regarding an abnormal V-shaped error confronting algebraic-based deconvolution process. Deconvolution was applied to an analysis of the effects of the Random Telegraph Noise (RTN) and Random Dopant Fluctuation (RDF) on the overall SRAM margin variations. This paper proposes a technique to suppress the problematic phenomena in the algebraic-based RDF/RTN deconvolution process. The proposed technique can reduce its relative errors by $10^{10}$ to $10^{16}$ fold, which is a sufficient reduction for avoiding the abnormal ringing errors in the RTN deconvolution process. The proposed algebraic-based analyses allowed the following: (1) detection of the truncating point of the TD-MV distributions by the screening test, and (2) predicting the MV-shift-amount by the assisted circuit schemes needed to avoid the out of specs after shipment.

  • PDF

Role of the Vestibular and Medullary Reticular Neuclei for the Motor Evoked Potentials in Rats (흰쥐의 운동유발전위에 대한 전정신경핵과 연수망상핵의 역할)

  • Lee, Moon-Young;Lee, Sung-Ho;Kim, Jae-Hyo;Park, Byung-Rim;Kim, Min-Sun
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.1 no.6
    • /
    • pp.603-611
    • /
    • 1997
  • The motor evoked potentials (MEPs) have been advocated as a method of monitoring the integrity of spinal efferent pathways in various injury models of the central nervous system. However, there were many disputes about origin sites of MEPs generated by transcranial electrical stimulation. The purpose of present study was to investigate the effect of major extrapyramidal motor nuclei such as lateral vestibular nucleus (VN) and medullary reticular nucleus (mRTN) on any components of the MEPs in adult Sprague-Dalwey rats. MEPs were evoked by electrical stimulation of the right sensorimotor cortex through a stainless steel screw with 0.5mm in diameter, and recorded epidurally at T9 - T10 spinal cord levels by using a pair of teflon-coated stainless steel wire electrodes with 1mm exposed tip. In order to inject lidocaine and make a lesion, insulated long dental needle with noninsulated tips were placed stareotoxically in VN and mRTN. Lidocaine of $2{\sim}3\;{\mu}l$ was injected into either VN or mRTN. The normal MEPs were composed of typical four reproducible waves; P1, P2, P3, P4. The first wave (P1) was shown at a mean latency of 1.2 ms, corresponding to a conduction velocity of 67.5 m/sec. The latencies of MEPs were shortened and the amplitudes were increased as stimulus intensity was increased. The amplitudes of P1 and P2 were more decreased among 4 waves of MEPs after lidocaine microinjection into mRTN. Especially, the amplitude of P1 was decreased by 50% after lidocaine microinjection into bilateral mRTN. On the other hand, lidocaine microinjection into VN reduced the amplitudes of P3 and P4 than other MEP waves. However, the latencies of MEPs were not changed by lidocaine microinjection into either VN or mRTN. These results suggest that the vestibular and reticular nuclei contribute to partially different role in generation of MEPs elicited by transcranial electrical stimulation.

  • PDF

RTN4 3'-UTR Insertion/Deletion Polymorphism and Susceptibility to Non-Small Cell Lung Cancer in Chinese Han Population

  • Lu, De-Yi;Mao, Xu-Hua;Zhou, Ying-Hui;Yan, Xiao-Long;Wang, Wei-Ping;Zheng, Ya-Biao;Xiao, Juan-Juan;Zhang, Ping;Wang, Jian-Guo;Ashwani, Neetika;Ding, Wei-Liang;Jiang, Hua;Shang, Yan;Wang, Ming-Hua
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.13
    • /
    • pp.5249-5252
    • /
    • 2014
  • Nogo protein, encoded by gene reticulon-4 (RTN4), includes three major isoforms by different splicing, named Nogo-A Nogo-B and Nogo-C. Nogo proteins play an important role in the apoptosis of cells, especially in tumor cells. RTN4 single nucleotide polymorphisms (SNPs) can influence the efficiency of transcription and translation thus being related with an individual's predisposition to cancer. The CAA insertion/deletion polymorphism (rs34917480) within RTN4 3'-UTR has been reported to be associated with many cancer types. In order to investigate the relationship between this polymorphism and susceptibility to non-small cell lung cancer (NSCLC) in the Chinese population, we conducted the present case-control study including 411 NSCLC patients and 471 unrelated healthy controls. The genotype distributions were significantly different between cases and controls (p=0.014). We found that the del allele could significantly increase NSCLC risk (ins/ins vs ins/del: p=0.007, OR 1.46, 95%CI=1.11-1.93; dominant model: p=0.004, OR 1.47, 95%CI=1.13-1.92 and allele model: p=0.008, OR 1.35, 95%CI=1.08-1.67). This association was stronger in participants over 60 years old, males and smokers. We therefore conclude that the CAA insertion/deletion polymorphism (rs34917480) contributes to non-small cell lung cancer risk in Chinese population. Age, sex and environmental exposure are also related to carcinogenic effects of rs34917480.

1/f Noise Characteristics of Sub-100 nm MOS Transistors

  • Lee, Jeong-Hyun;Kim, Sang-Yun;Cho, Il-Hyun;Hwang, Sung-Bo;Lee, Jong-Ho
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.6 no.1
    • /
    • pp.38-42
    • /
    • 2006
  • We report 1/f noise PSD(Power Spectrum Density) of sub-100 nm MOSFETs as a function of various parameters such as HCS (Hot Carrier Stress), bias condition, temperature, device size and types of MOSFETs. The noise spectra of sub-100 nm devices showed Lorentzian-like noise spectra. We could check roughly the position of a dominant noise source by changing $V_{DS}$. With increasing measurement temperature, the 1/f noise PSD of 50 nm PMOS device decreases, but there is no decrease in the noise of NMOS device. RTN (Random Telegraph Noise) was measured from the device that shows clearly a Lorentzian-like noise spectrum in 1/f noise spectrum.

Evaluation of Combine IGRT using ExacTrac and CBCT In SBRT (정위적체부방사선치료시 ExacTrac과 CBCT를 이용한 Combine IGRT의 유용성 평가)

  • Ahn, Min Woo;Kang, Hyo Seok;Choi, Byoung Joon;Park, Sang Jun;Jung, Da Ee;Lee, Geon Ho;Lee, Doo Sang;Jeon, Myeong Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.201-208
    • /
    • 2018
  • Purpose : The purpose of this study is to compare and analyze the set-up errors using the Combine IGRT with ExacTrac and CBCT phased in the treatment of Stereotatic Body Radiotherapy. Methods and materials : Patient who were treated Stereotatic Body Radiotherapy in the ulsan university hospital from May 2014 to november 2017 were classified as treatment area three brain, nine spine, three pelvis. First using ExacTrac Set-up error calibrated direction of Lateral(Lat), Longitudinal(Lng), Vertical(Vrt), Roll, Pitch, Yaw, after applied ExacTrac moving data in addition to use CBCT and set-up error calibrated direction of Lat, Lng, Vrt, Rotation(Rtn). Results : When using ExacTrac, the error in the brain region is Lat $0.18{\pm}0.25cm$, Lng $0.23{\pm}0.04cm$, Vrt $0.30{\pm}0.36cm$, Roll $0.36{\pm}0.21^{\circ}$, Pitch $1.72{\pm}0.62^{\circ}$, Yaw $1.80{\pm}1.21^{\circ}$, spine Lat $0.21{\pm}0.24cm$, Lng $0.27{\pm}0.36cm$, Vrt $0.26{\pm}0.42cm$, Roll $1.01{\pm}1.17^{\circ}$, Pitch $0.66{\pm}0.45^{\circ}$, Yaw $0.71{\pm}0.58^{\circ}$, pelvis Lat $0.20{\pm}0.16cm$, Lng $0.24{\pm}0.29cm$, Vrt $0.28{\pm}0.29cm$, Roll $0.83{\pm}0.21^{\circ}$, Pitch $0.57{\pm}0.45^{\circ}$, Yaw $0.52{\pm}0.27^{\circ}$ When CBCT is performed after the couch movement, the error in brain region is Lat $0.06{\pm}0.05cm$, Lng $0.07{\pm}0.06cm$, Vrt $0.00{\pm}0.00cm$, Rtn $0.0{\pm}0.0^{\circ}$, spine Lat $0.06{\pm}0.04cm$, Lng $0.16{\pm}0.30cm$, Vrt $0.08{\pm}0.08cm$, Rtn $0.00{\pm}0.00^{\circ}$, pelvis Lat $0.06{\pm}0.07cm$, Lng $0.04{\pm}0.05cm$, Vrt $0.06{\pm}0.04cm$, Rtn $0.0{\pm}0.0^{\circ}$. Conclusion : Combine IGRT with ExacTrac in addition to CBCT during Stereotatic Body Radiotherapy showed that it was possible to reduce the set-up error of patients compared to single ExacTrac. However, the application of Combine IGRT increases patient set-up verification time and absorption dose in the body for image acquisition. Therefore, depending on the patient's situation that using Combine IGRT to reduce the patient's set-up error can increase the radiation treatment effectiveness.

  • PDF

Evaluation of the usefulness of IGRT(Image Guided Radiation Therapy) for markerless patients using SGPS(Surface-Guided Patient Setup) (표면유도환자셋업(Surface-Guided Patient Setup, SGPS)을 활용한 Markerless환자의 영상유도방사선치료(Image Guided Radiation Therapy, IGRT)시 유용성 평가)

  • Lee, Kyeong-jae;Lee, Eung-man;Lee, Jeong-su;Kim, Da-yeon;Ko, Hyeon-jun;Choi, Shin-cheol
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.109-116
    • /
    • 2021
  • Purpose: The purpose of this study is to evaluate the usefulness of Surface-Guided Patient Setup by comparing the patient positioning accuracy when image-guided radiation therapy was used for Markerless patients(unmarked on the skin) using Surface-Guided Patient Setup and Marker patients(marked on the skin) using Laser-Based Patient Setup. Materials And Methods: The position error during IGRT was compared between a Markerless patient initially set up with SGPS using an optical surface scanning system using three cameras and a Marker patient initially set up with LBPS that aligns the laser with the marker drawn on the patient's skin. Both SGPS and LBPS were performed on 20 prostate cancer patients and 10 Stereotactic Radiation Surgery patients, respectively, and SGPS was performed on an additional 60 breast cancer patients. All were performed IGRT using CBCT or OBI. Position error of 6 degrees of freedom was obtained using Auto-Matching System, and comparison and analysis were performed using Offline-Review in the treatment planning system. Result: The difference between the root mean square (RMS) of SGPS and LBPS in prostate cancer patients was Vrt -0.02cm, Log -0.02cm, Lat 0.01cm, Pit -0.01°, Rol -0.01°, Rtn -0.01°, SRS patients was Vrt 0.02cm, Log -0.05cm, Lat 0.00cm, Pit -0.30°, Rol -0.15°, Rtn -0.33°. there was no significant difference between the two regions. According to the IGRT standard of breast cancer patients, RMS was Vrt 0.26, Log 0.21, Lat 0.15, Pit 0.81, Rol 0.49, Rtn 0.59. Conclusion:. As a result of this study, the position error value of SGPS compared to LBPS did not show a significant difference between prostate cancer patients and SRS patients. In the case of additionally performed SGPS breast cancer patients, the position error value was not large based on IGRT. Therefore, it is considered that it will be useful to replace LBPS with SGPS, which has the great advantage of not requiring patient skin marking..

Field Validation of PBcast in Timing Fungicide Sprays to Control Phytophthora Blight of Chili Pepper (고추 역병 방제시기 결정을 위한 PBcast 예측모델 타당성 포장 평가)

  • Ahn, Mun-Il;Do, Ki Seok;Lee, Kyeong Hee;Yun, Sung Chul;Park, Eun Woo
    • Research in Plant Disease
    • /
    • v.26 no.4
    • /
    • pp.229-238
    • /
    • 2020
  • Field validation of PBcast, an infection risk model for Phytophthora blight of pepper, was conducted through a designed field experiment in 2012 and 2013. Conduciveness of weather conditions at 26 locations in Korea in 2014-2017 was also evaluated using PBcast. The PBcast estimated daily infection risk (IR) of Phytophthora capsici based on weather and soil texture data. In the designed filed experiment, four treatments including routine sprays at 7-day intervals (RTN7), forecast-based sprays when IR reached 200 (IR200) and 224 (IR224), and no spray (CTRL) were compared in terms of disease incidence and number of sprays recommended for disease control. In 2012, IR had reached over 200 twice, but never reached 224. In 2013, IR had reached over 200 three times and once higher than 224. The RTN7 plots were sprayed 17 and 18 times in 2012 and 2013, respectively. Weather conditions throughout the country were generally conducive for Phytophthora blight and 3-4 times of fungicide sprays would have been reduced if the PBcast forecast information was adopted in the decision-making for fungicide sprays. In conclusion, the PBcast forecast would be useful to reduce fungicide applications without losing the disease control efficacy to protect pepper crop from Phytophthora blight.

Impact of Trap Position on Random Telegraph Noise in a 70-Å Nanowire Field-Effect Transistor

  • Lee, Hyunseul;Cho, Karam;Shin, Changhwan;Shin, Hyungcheol
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.2
    • /
    • pp.185-190
    • /
    • 2016
  • A 70-${\AA}$ nanowire field-effect transistor (FET) for sub-10-nm CMOS technology is designed and simulated in order to investigate the impact of an oxide trap on random telegraph noise (RTN) in the device. It is observed that the drain current fluctuation (${\Delta}I_D/I_D$) increases up to a maximum of 78 % due to the single electron trapping. In addition, the effect of various trap positions on the RTN in the nanowire FET is thoroughly analyzed at various drain and gate voltages. As the drain voltage increases, the peak point for the ${\Delta}I_D/I_D$ shifts toward the source side. The distortion in the electron carrier density and the conduction band energy when the trap is filled with an electron at various positions in the device supports these results.