• Title/Summary/Keyword: RT(Reverberation-Time)

Search Result 25, Processing Time 0.024 seconds

Effects of reverberation time on binaural Korean monosyllabic word recognition in normal hearing subjects (잔향시간이 양이를 사용한 한국어 단음절 인지에 미치는 영향)

  • Lim, Dukhwan
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.6
    • /
    • pp.678-682
    • /
    • 2021
  • Reverberation Time (RT) with noise levels can affect speech recognition ability in a listening environment. The degree of influence may depend on reverberation times and modes of binaural hearing. In this study, Korean monosyllabic Word Recognition Scores (WRS) were investigated in 10 young normal hearing subjects under binaural conditions. The RT of 3.4 s and signal to noise ratio of 0 dB were used at 55 dB HL for diotic (noise with the same phase) and dichotic (noise with the fixed phase difference, π) conditions. The improvement in WRS was noted in dichotic hearing (p < 0.05) while the similar trend was not observed in diotic hearing. This data may be useful in analyzing psychoacoustic effects of RTs under noisy conditions.

Investigation of acoustic performances of the creative convergence classrooms in elementary schools (초등학교 창의융합교실의 음향성능 조사)

  • A-Hyeon Jo;Chan-Hoon Haan
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.4
    • /
    • pp.285-297
    • /
    • 2023
  • The present study aims to investigate the acoustic performance of the creative convergence classrooms in Korea used by elementary school students under the age of 9 introduced through the school space innovation project. In order to do this, acoustic performances of three creative convergence classrooms were measured. The measured acoustic parameters were background noise levels, Reverberation Time (RT), D50, Speech Transmission Index (STI), and Inter-Aural Cross Correlation (IACC). Also, acoustic parameters including Transmission Loss (TL) and standardized level difference (DnT) have been measured for the analysis of sound insulation performance of walls. In addition, the noise level was measured according to the opening conditions of doors and windows in the classroom. As a result, background noise level was measured at an average of 28.0 dB(A) to 32.8 dB(A) when the air conditioner was not operated, and the RT did not exceed 0.6 s. There were differences in IACC according to various desk layouts, and IACC values were high in the center line and the seats near the sound source. In particular, higher IACC was measured at the seats on the center line facing the source squarely. Regarding noise level in the classroom according to the opening conditions of doors and windows, the standards were exceeded when all windows, or windows and doors front onto the corridor were opened.

Effect of Diffuser Locations on the Room Acoustical Parameters in 1:25 Scale Model Hall (1:25 축소모형 홀에서 확산체의 설치부위에 따른 실내 음향지표의 변화)

  • Kim, Yong-Hee;Seo, Choon-Ki;Lee, Hye-Mi;Jeon, Jin-Yong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.31 no.3
    • /
    • pp.115-128
    • /
    • 2012
  • This paper investigates the effects of diffuser on the acoustical parameters in music hall with consideration of the result of scattering coefficient measurement. A scale model hall of 600 seats with orchestra shell was used for experiments. The materials of 1:50 scale model was chosen through absorption coefficient measurement based on ISO 354. The model was matched to the computer simulation model in terms of reverberation time. In order to evaluate the effect of diffuser location, the measurements were accomplished with and without diffusers according to 7 configurations by diffuser-installed region; sidewall, balcony front, ceiling and so on. The following acoustical parameters were extracted from each measurement case; Reverberation time (RT), Early decay time (EDT), Clarity (C80), Center time (Ts), Sound strength (G) and Temporal diffusion (TD) from the auto-correlation function (ACF) of impulse responses. As a result, the absorption power and diffusion power were increased with number of diffusers. Accordingly RT, EDT and G were decreased by diffuser and the redirection of reflections was occurred briskly. Averaged TD was 6.05 to 6.30 by measurement cases. RT was found to be the most related factor to diffusion power (R = 0.94). The correlation between TD and EDT was high (R = 0.73). In addition, the effects of diffuser-installed location were discussed in terms of acoustical parameter variation.

A Study on the Acoustical Characteristics of Pistol Impluse and MLS Source Measurements in Room Types (음향측정시 실의 종류와 음원에 따르는 음향인자 측정분석에 관한 연구)

  • Kim, Jeong-Jung;Son, Jang-Ryeol
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.1028-1031
    • /
    • 2004
  • Last target of architectural acoustics is that people wish to convey voice effectively from the space adaptively in use purpose in building. But, to how exactly through space sound source that wish to deliver from indoor can be passed does quantification sound estimation method is proposing various kinds physical parameter to estimate degree of voice definition (Speech articulation) and reverberation. Result that evaluate sound source about MLS signal and Impluse signal by pistol in this treatise could know that converge in MLS and measurement error extent about reverberation time(RT) of sound benevolent person. And value is thought there is problem showing change irregularly about sound benevolent person of D50, C80 etc. Finally, in case is spread sound field in difference of sound pressure level, when measure about change of sound pressure level, sound benevolent person could know that there is no different effect.

  • PDF

Acoustical design for remodeling of the Little theatre in Sejong Performing Arts Center (세종문화회관 소극장 리모델링을 위한 음향설계)

  • Jeon, Jin-Yong;Lee, Pyoung-Jik;Seo, Choon-Ki
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.991-996
    • /
    • 2007
  • The Little theater in Sejong Performing Arts Center is a proscenium theater with 447 seats, which was built in 1978. The remodeling of the theater was decided in 2005 and acoustical design was conducted. Design guidelines were suggested based on the feasibility studies and acoustical measurement results. Target reverberation time was set at 1.2-1.6s with respect to the main performances. For the acoustical design, side balconies were added to increase the level of lateral reflections. Acoustic diffusers were designed and scattering coefficients were measured in a 1:10 reverberation chamber. From the results of computer simulation and a 1:10 scale model measurement, it was indicated that the new space will have RT of 1.2-1.6 s in middle frequencies when fully occupied.

  • PDF

Effect of Acoustic Reflector's Surface Density on Sound Absorption Characteristics and Stage Acoustics (음향 반사판의 밀도별 흡음특성 및 무대음향에의 영향)

  • Kim, Young-Sun;Jeong, Jeong-Ho;Jeon, Jin-Yong;Kim, Myeong-Seok
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.5
    • /
    • pp.429-436
    • /
    • 2012
  • In concert halls and auditoriums, acoustic reflector and stage enclosure is one of the main factors on the room and stage acoustic characteristics. As a stage enclosure and acoustic reflector honey comb based light-weight reflector is widely used, because it is easy to install. However, there was not enough research on the surface density effect on room and stage acoustics. In this study, sound absorption coefficient tests on three kinds of wooden acoustic reflectors with different surface density were conducted. Surface density of acoustic reflector was changed from 11 kg/$m^2$ to 41 kg/$m^2$. For the low frequency excitation, sub-woofer was used with omnidirectional loud-speaker simultaneously. From the experiments, it was found that sound absorption coefficient below 250 Hz band was decrease by the increment of surface density. In order to check the influence of the surface density on room and stage acoustic parameters, room acoustic simulation was conducted with sound absorption coefficients, which were tested in reverberation chamber. By the increment of surface density of acoustic reflector, RT(reverberation time) and EDT(early decay time) were increased. Also, ST(stage support) was improved in low frequency bands.

Comparison of Predicted Acoustics with the Measured Acoustic Properties of a Multi-Purpose Hall

  • Haan, Chan-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.25 no.3E
    • /
    • pp.95-100
    • /
    • 2006
  • The present study presents the design procedures and the acoustic properties of the main hall of Ansan Cultural Arts Center in Korea which has opened in 2004. The acoustic design values are compared with the measured acoustic properties of the completed multi-purpose hall. Acoustic design criteria were suggested in the design stage through the 3-dimentional computer simulations. The acoustic parameters including SPL, RT, C80, $D_{50}$M, RASTI were measured in the hall after completed. Acoustic measurements were carried out in the 40 measurement points using MLS sound source signal in 4 different sound source points. The results show the even distribution of sound levels within the 2.0dB of difference among all seats. The reverberation time of 1.66sec was measured which is similar to the objective value of 1.65 sec in empty states. It was also found that average C80 values lie in the objective extents of C80 from -1 to 3dB and average D50 value of 54 was measured. Thus, it is concluded that the hall can be used as a multi-purpose hall with a suitable acoustic conditions.

An Experimental Study on the Acoustical Characteristics in the Main Hall of Catholic Church (성당본당의 실내음향 특성에 관한 실험적 연구)

  • Shin, Young-Jin;Park, Hyeon-Ku;Choi, Hyung-Wook;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.468-473
    • /
    • 2000
  • Recently the acoustic design has been considered the important part of architectural design. However, in the design of Catholic churches the exterior beauty is still main point. This study aims to find out the acoustical characteristics in the main hall of Catholic churches. Six catholic churches were selected for this experiment and the physical parameters which represent the acoustic characteristics of room were compared by the plan type and the architectural factor. The physical parameters compared and analyzed were SD(Stand deviation) of SPL(sound pressure level), RT(reverberation time), $D_{50}$(definition), $C_{80}$(clarity) and STI(speech transmission index).

  • PDF

The Effect of Stage Ceiling Height on the Acoustic Characteristics of Concert Halls (콘서트홀의 무대 천장높이 변화에 의한 객석음향의 영향)

  • Shin Dong-Jae;Jeon Jin-Yong;Seo Hyung-Gyoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.24 no.1
    • /
    • pp.21-28
    • /
    • 2005
  • In this Paper, the effect of stage ceiling height on the acoustic characteristics of rectangular concert halls are investigated. To find out the acoustic properties of audience area, A simple Boston Symphony Hall(BSH) model which is typically rectangular shaped was applied for computer simulation. A newly built rectangular concert hall with 400 seats was also chosen for a scale model $(1.2m{\times}0.68m{\times}0.31m)$ study and its computer simulation varing the stage ceiling height and the volume. The results show that RT increased as the stage ceiling was lowered and the difference rate of RT by its variance is from -0.09 to -0.06[sec/m].

Measurement and Evaluation of the Acoustic Performance in the Royal Palace Buildings of Joseon Dynasty - Focused on Pyeonjeon and Chimjeon - (조선 궁궐 건축물의 음향성능 측정 및 평가 - 편전 및 침전을 중심으로 -)

  • Kim, Nam-Wook;Kim, Myung-Jun;Han, Wook
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.12
    • /
    • pp.1269-1280
    • /
    • 2009
  • This study was performed to construct sound performance DB of royal palace buildings and to examine the special quality more scientifically. Research target of royal palace were Changdeokgung and Gyeongbokgung. Sound insulation performance between the adjacent room and facade, room acoustics of Pyeonjeon and Chimjeon which is representative building in royal palace were examined through field measurement. Measured values of RT($T_{mf}$) at Pyeonjeon were 0.78 sec. and 1.03 sec. in Seonjeongjoen and Sajeongjoen, respectively. The RTs of both Pyeonjeon buildings were estimated suitable for speech and lecture considering their volume. The RT($T_{mf}$)s at Chimjeon were measured in range of 0.29~0.55 sec. This meant that the acoustic energy in rooms was decreased by sound transmission through mulberry paper(Hanji) of traditional windows and doors. As a sound insulation performance, the single-number quantities($D_{ls,2m,nT,w}$) of the building facades in Pyeonjeon and Chimjeon were measured 4~20 dB. Also the single-number quantities($D_{p,w}$) between the adjacent rooms in Chimjeon were measured 3~18 dB. Sound insulation performance of traditional building elements such as window and door depended strongly on their layers and area.