• Title/Summary/Keyword: RSD

Search Result 533, Processing Time 0.025 seconds

Analytical Validation of Rosmarinic Acid in Water Extract of Perilla frutescens Britton var. acuta Kudo as Functional Health Ingredient (건강기능식품 기능성 원료로써 장흥 차조기 열수 추출물의 지표성분인 로즈마린산 분석법 검증)

  • Park, Sung-Yong;Kim, Jung-Eun;Choi, Chul-Yung;Lee, Dong-Wook;Kim, Ki-Man;Yoon, Goo;Yoon, In-Su;Moon, Hong-Seop;Cho, Seung-Sik
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.44 no.1
    • /
    • pp.85-88
    • /
    • 2015
  • This study attempted to establish an HPLC analysis method for determination of marker compounds as a part of material standardization for the development of health functional food materials from Perilla frutescens Britton var. acuta Kudo. The quantitative determination method of rosmarinic acid as a marker compound of P. frutescens Britton var. acuta Kudo extract (PFE) was optimized by HPLC analysis using a C18 column ($4.6{\times}150mm$, $5{\mu}m$) with 0.1% acetic acid as the elution gradient and methanol as the mobile phase at a flow rate of 1 mL/min and detection wavelength of 280 nm. The HPLC/UV method was applied successfully to quantification of the marker compound in PFE after validation of the method with linearity, accuracy, and precision. The method showed high linearity in the calibration curve at a coefficient of correlation ($R^2$) of 0.9995, and the limit of detection and limit of quantitation were $0.36{\mu}g/mL$ and $1.2{\mu}g/mL$, respectively. Relative standard deviation (RSD) values of data from intra- and inter-day precision were less than 3.21% and 1.43%, respectively. Recovery rate test at rosmarinic acid concentrations of 12.5, 25 and $50{\mu}g/mL$ scored between 97.04~98.98% with RSD values from 0.25~1.97%. These results indicate that the established HPLC method is very useful for the determination of marker compound in PFE to develop a health functional material.

Development and Evaluation of Silicon Passive Layer Dosimeter Based Lead-Monoxide for Measuring Skin Dose (피부선량 측정을 위한 Lead-Monoxide 기반의 Silicon Passive layer PbO 선량계 개발 및 평가)

  • Yang, Seung-Woo;Han, Moo-Jae;Jung, Jae-Hoon;Bae, Sang-Il;Moon, Young-Min;Park, Sung-Kwang;Kim, Jin-Young
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.781-788
    • /
    • 2021
  • Due to the high sensitivity to radiation, excessive exposure needs to be prevented by accurately measuring the dose irradiated to the skin during radiation therapy. Although clinical trials use dosimeters such as film, OSLD, TLD, glass dosimeter, etc. to measure skin dose, these dosimeters have difficulty in accurate dosimetry on skin curves. In this study, to solve these problems, we developed a skin dosimeter that can be attached according to human flexion and evaluated its response characteristics. For the manufacture of the dosimeter, lead oxide (PbO) with high atomic number (ZPb: 82, ZO: 8) and density (9.53 g/cm3) and silicon binders that can bend according to human flexion were used. In the case of a dosimeter made of PbO material, the performance degradation has been prevented by using parylene and others due to the presence of degradation due to oxidation, but the previously used parylene is affected by bending, so a new form of passive layer was produced and applied to the skin dosimeter. The characteristic evaluation of the skin dosimeter was evaluated by analyzing SEM, reproducibility, and linearity. Through SEM analysis, bending was evaluated, reproducibility and linearity at 6 MeV energy were evaluated, and applicability was assessed with a skin dosimeter. As a result of observing the dosimeter surface through SEM analysis, the parylene passive layer PbO dosimeter with the positive layer raised to the parylene produced cracks on the surface when bent. On the other hand, no crack was observed in the silicon passive layer PbO dosimeter, which was raised to silicon passive layer. In the reproducibility measurement results, the RSD of the silicon passive layer PbO dosimeter was 1.47% which satisfied the evaluation criteria RSD 1.5% and the linearity evaluation results showed the R2 value of 0.9990, which satisfied the evaluation criteria R2 9990. The silicon passive layer PbO dosimeter was evaluated to be applicable to skin dosimeters by demonstrating high signal stability, precision, and accuracy in reproducibility and linearity, without cracking due to bending.

The Optimization and Verification of an Analytical Method for Sodium Iron Chlorophyllin in Foods Using HPLC and LC/MS (식품 중 철클로로필린나트륨의 HPLC 및 LC/MS 최적 분석법과 타당성 검증)

  • Chong, Hee Sun;Park, Yeong Ju;Kim, Eun Gyeom;Park, Yea Lim;Kim, Jin Mi;Yamaguchi, Tokutaro;Lee, Chan;Suh, Hee-Jae
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.2
    • /
    • pp.148-157
    • /
    • 2019
  • An optimized analytical method for sodium iron chloriphyllin in foods was established and verified by using high performance liquid chromatography with attached diode array detection. An Inertsil ODS-2 column and methanol-water (80:20 containing 1% acetate) as a mobile phase were employed. The limit of detection and quantitation of sodium iron chloriphyllin were 0.1 and 0.3 mg/kg, respectively, and the linearity of calibration curve was excellent ($R^2=0.9999$). The accuracy and precision were 93.9~104.95% and 2.0~7.7% in both inter-day and intra-day tests. Recoveries for candy and salad dressing were ranged between 93 and 104% (relative standard deviation, (RSD) 0.3~4.3%), and between 83 and 115% (RSD 1.2~2.0%), respectively. Liquid chromatography mass spectrometry was used to verify the main components of sodium iron chlorophyllin which were Fe-isochlorin e4 and Fe-chlorin e4.

Factors affecting the formation of bound 3-monochloropropane-1,2-diol in a fried snack model (유탕 과자 모델에서 결합형 3-monochloropropane-1,2-diol 생성에 영향을 미치는 요인)

  • Kang, Jun-Hyuk;Joung, Woo-Young;Rho, Hoi-Jin;Baek, Hyung-Hee
    • Korean Journal of Food Science and Technology
    • /
    • v.52 no.6
    • /
    • pp.565-572
    • /
    • 2020
  • The 3-monochloropropane-1,2-diol (3-MCPD) is a contaminant that occurs in foodstuffs in its free form as well as in its bound form. The objective of this study was to evaluate the effects of emulsifier, frying temperature, and the amounts of salt and oil on the formation of bound 3-MCPD in a fried snack model. Emulsifier affected the formation of bound 3-MCPD; furthermore, it was observed that the largest amount of bound 3-MCPD was detected in the fried snack model when glycerin esters of fatty acids were used as emulsifiers. Frying temperature also affected the formation of bound 3-MCPD, which increased significantly as the frying temperature increased from 145 to 190℃. In addition, salt affected the formation of bound 3-MCPD. As the amount of salt increased, the amount of bound 3-MCPD also increased significantly. Moreover, it was observed that the amount of oil did not affect the formation of bound 3-MCPD. These results will aid in the reduction of bound 3-MCPD in fried snacks.

Comparative and Feasibility Evaluation of Detection Ability of Relative Dosimeters using CsPbI2Br and CsPbIBr2 Materials in Brachytherapy QA (근접방사선치료 QA에서 CsPbI2Br과 CsPbIBr2를 이용한 상대 선량계들의 검출 능력 비교 및 적용가능성 평가)

  • Seung-Woo Yang;Sung-Kwang Park
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.433-440
    • /
    • 2023
  • High dose rate brachytherapy is a cancer treatment that intensively irradiates radiation to tumors by inserting isotopes with high dose rates into the body. For such a treatment, it is necessary to deliver an accurate dose to the tumor tissue through an accurate treatment plan while delivering only a minimum dose to the normal tissue. Therefore, it is very important to check the location accuracy of the source through accurate Quality Assurance (QA) in clinical practice. However, since the source position is determined using a ruler, automatic radiographer, video monitor, etc. in clinical practice, it yields inaccurate results. In this study, a semiconductor dosimeter using CsPbI2Br and CsPbIBr2 was fabricated. And, in order to analyze whether it is more suitable for the relative QA dosimeter for brachytherapy device among the two materials, the radiation detection ability of each was compared and evaluated. In order to evaluate the radiation detection ability in brachytherapy, the reproducibility and linearity of the two materials were evaluated in 192IR. In the reproducibility evaluation, CsPbI2Br presented a Relative Standard Deviatio(RSD) of 0.98% and CsPbIBr2 presented an RSD of 3.45%. In the linearity evaluation, the coefficient of determination (R2) of CsPbI2Br was presented as 0.9998, and the R2 of CsPbIBr2 was presented as 0.9994. As a result of the evaluation, it was found that CsPbI2Br was more stable in radiation detection while satisfying the evaluation criteria in the dosimeter manufactured in this experiment. Therefore, CsPbI2Br material is suitable for application as a relative dosimeter for radiation detection in brachytherapy devices.

Efficient Distributed Storage for Space Information Network Based on Fountain Codes and Probabilistic Broadcasting

  • Kong, Bo;Zhang, Gengxin;Zhang, Wei;Dong, Feihong
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.10 no.6
    • /
    • pp.2606-2626
    • /
    • 2016
  • This article investigates the distributed data storage problem in the space information network (SIN) using distributed fountain codes. Since space nodes in the SIN are resource-limited, in order to reduce energy consumption while improving the storage reliability, an efficient distributed storage based on fountain codes and probabilistic broadcasting (DSFPB) strategy is proposed. In the proposed strategy, source packets are disseminated among the entire network according to probabilistic broadcasting (PBcast), and the final degree distribution is close to the desired robust soliton distribution (RSD), this is benefited from the appropriate packets encoding procedure of the proposed strategy. As presented by the analysis and simulations, the total cost of data dissemination is greatly reduced compared with existing representative strategies, while improving the decoding performance.

Determination of Chlorpromazine Using Plasticizers as Extraction Solvent (가소제를 이용한 클로르프로마진의 용매 추출 분광광도법)

  • Lee, Ji-Yeoun;Jung, Moon-Mo;Hur, Moon-Hye;Ahn, Moon-Kyu
    • YAKHAK HOEJI
    • /
    • v.42 no.3
    • /
    • pp.243-247
    • /
    • 1998
  • A method for the determination of basic drugs based on their reaction with picric acid to form an ion-association complex extractable into several plasticizers was developed. Ba sic drugs-picric acid complexes in acid medium could be extracted quantitatively into several plasticizers except phosphates. For example, the chlorpromazine-picric acid complex showed maximum absorbance at near 410nm and was applied to extraction spectrophotometric determination of chlorpromazine. The calibration curves are linear (r>0.998) within a range from $10^{-6}to\;5{\times}10^{-4}M$ and the precision of the method was acceptable because RSD was less than 2.6% (n=7). The factors affecting the extraction system was discussed.

  • PDF

An Accelerated Life Test Sampling Plan for Bulk Material (벌크재료 가속시험샘플링검사방식설계)

  • Kim Jong-Geol;Kim Dong-Cheol
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2006.04a
    • /
    • pp.411-419
    • /
    • 2006
  • This paper aims at designing an accelerated life test sampling plan for bulk material and showing its application for an arc-welded gas pipe. It is an integrated model of the accelerated life test procedure and bulk sampling procedure. The accelerated life tests were performed by the regulation, RSD 0005 of ATS at KITECH and bulk sampling was used for acceptance. Design parameters might be total sample size(segments and increments), stress level and so on. We focus on deciding the sample size by minimizing the asymptotic variance of test statistic as well as satisfying consumer's risk under Weibull life time distribution with primary information on shape parameter.

  • PDF

Determination of Iron, Copper, and Zinc in Rainwater by Ion Chromatography (이온 크로마토그래피법에 의한 강수 중 철, 구리, 아연의 정량)

  • 이용근;이계형;이동수
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.7 no.2
    • /
    • pp.137-142
    • /
    • 1991
  • A method is developed for the simultaneous determination of dissolved iron, copper, and zinc in rainwater. The method involves 25-fold evaporative concentration, ion chromatographic separation and subsequent spectrophotometric detection after post-column reaction with 4-(2-pyridylazo) resorcinol. Analytical sensitivities, being defined by the slopes of calibration curves, are 0.93, 0.54, and 0.11 Abs/ $\mu$g/ml for iron, copper, zinc, respectively. Detection limits render around a few tenth of one ng/ml. Precisions evaluated by replicate analysis of real sample are better than 10% RSD. Due to the lack of certified standards for rainwater, the accuracy of the method could not be assessed directly. However, the results of this method agree well with those by inductively coupled plasma mass spectrometry. Analytical results for a suite of Seoul rainwaters are presented herein.

  • PDF

Low Power 10-Bit 10MS/s ADC for Mobile Communication System (무선통신용 저전력 10-Bit 10MS/s ADC)

  • Kim Jun-Ho;Lee Youg-Jic;Kim Joon-Yub
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.27-30
    • /
    • 2002
  • 10-bit 해상도, 10MS/s의 ADC를 Stage 당 1.5-Bit의 Resolution을 가지는 Redundant signed digit(RSD) 방식의 파이프라인 구조를 이용하여 설계하였다. Error Correction Logic을 사용함으로써 비교기를 Coarse하게 설계하였고 잔류 전압 증폭기의 최적 Scaling을 통하여 일반적인 ADC에 비해 성능 저하 없이 효율적으로 소비 전력을 감소시켰다. 또한, Charge Pump의 선택적 사용을 통해 기생 커패시턴스의 영향을 최소화함으로써 잔류전압 증폭기의 출력 전압 특성을 향상 시켰다. 삼성 0.35u CMOS 공정 파라미터를 이용하여 입력 전압 $-1{\sim}1V$, 공급 전압 $-1.5{\sim}1.5V$에서 18.73mW로 설계하였으며 HSPICE로 시뮬레이션 하였다.

  • PDF