• 제목/요약/키워드: ROSs

검색결과 540건 처리시간 0.026초

Length Optimization for Unconstrained Visco-elastic Damping Layer of Beams (비구속형 점탄성 제진층을 갖는 보의 제진층 길이 최적화)

  • 이두호;황우석
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.665-671
    • /
    • 2003
  • Length of an unconstrained viscoelastic damping layer on beams is determined to maximize loss factor using a numerical search method. The fractional derivative model can describe damping characteristics of the viscoelastic damping material, and is used to represent nonlinearity of complex modulus with frequencies and temperatures. Equivalent flexural rigidity of the unconstrained beam is obtained using Ross, Ungar, Kerwin(RUK) equation. The loss factors of partially covered unconstrained beam are calculated by a modal strain energy method. Optimal lengths of the unconstrained viscoelastic damping layer of beams are obtained with respect to ambient temperatures and thickness ratios of beam and damping layer.

  • PDF

$\bar{X}$ Control Chart with Runs Rules: A Review (규칙을 가진 $\bar{X}$ 관리도에 관한 통람)

  • Park, Jin-Young;Seo, Sun-Keun
    • Journal of Korean Society for Quality Management
    • /
    • 제40권2호
    • /
    • pp.176-185
    • /
    • 2012
  • After a work of Derman and Ross(1997) that considered simple main runs rules and derived ARL (Average Run Length) using Markov chain modeling, $\bar{X}$ control chart based on diverse alternative main and supplementary runs rules that is the most popular control chart for monitoring the mean of a process are proposed. This paper reviews and discusses the-state-of-art researches for these runs rules and classifies according to several properties of runs rules. ARL derivation for a proposed runs rule is also illustrated.

Measurements of Photoabsorption Cross Sections of Nitric Oxide by Using Double-Ionization Chamber

  • Chung, Yang-Soo;Kim, Hyun;Chung, Young-Min
    • Journal of the Optical Society of Korea
    • /
    • 제10권4호
    • /
    • pp.157-161
    • /
    • 2006
  • A synchrotron light source is useful in the vacuum ultraviolet (VUV) regime for olecular spectroscopy, such as photo absorption, photoionization, and dissociative hotoionization. In this research, we used a double-ion chamber (DIC) to measure hotoabsorption cross sections of a NO molecule in the wavelength range from 90 to 135 nm of 3B1 beam-line of the Pohang synchrotron light source with the resolution of the onochromator being 0.06 nm. The appearance wavelength for ionization was measured to be $134.19{\pm}0.09nm$ that is placed in the middle of the reported values though they don't agree with each other within the relative error limits. The auxiliary experimental works ave been done to test if there are any systematic error sources. The resultant ross-sections agree with previous results in general.

Nomenclature of Pyroxenes

  • Morimoto, N.;Fabries, J.;Ferguson, A.K.;Ginzburg, I.V.;Ross, M.;Seifert, F.A.;Zussman, J.;Aoki, A.;Gottardi, G.
    • Journal of the Mineralogical Society of Korea
    • /
    • 제1권2호
    • /
    • pp.131-145
    • /
    • 1988
  • This is the final report on the nomenclature of pyroxenes by the Subcommittee on Pyroxenes established by the Commission on New Minerals and Mineral Names of the International Mineralogical Association. The recommendations of the Subcommittee as put forward in this report have been formally accepted by the Commission. Accepted and widely used names have been chemically defined, by combining new and conventional methods, to agree as far as possible with the consensus of present use. Twenty names are formally accepted, among which thirteen are used to represent the end members of definite chemical compositions. In common binary solid-solution series, species names are given to the two end members by the "50% rule." Adjectival modifiers for pyroxene mineral names are defined to indicate unusual amounts of chemical constituents. This report includes a list of 105 previously used pyroxene names that have been formally discarded by the Commission.

  • PDF

The Synthesis and Surface Properties of N-Acyl-N-Methyl Taurates (N-아실-N-메틸 타우린 염류의 합성 및 계면성)

  • Jeong, No-Hee;Nam, Ki-Dae;Kim, Tae-Yeong
    • Journal of the Korean Applied Science and Technology
    • /
    • 제9권1호
    • /
    • pp.1-6
    • /
    • 1992
  • New five N-acyl-N-methyl taurate and their sodium salts were synthesized by acylating sodium N-methyl taurate in water in the presense of inorganic alkali as a catalyst. Wherein acyl group is a straight-chain radical of 10 to 18 carbon atoms. These compounds were identified by infrared spectroscopy. Surface activities of these sodium N-acyl-N-methyl taurate including surface tension, Ross-Miles foaming powers, foam stabilities, emulsifying powers and detergency were measured respectively. Also critical micelle concentration(cmc) were evaluated. Consequently these anionic surfactants with long chain acyl amine showed good emulsifying power of O/W type and had a good detergence.

Localization of phenoloxidases in coprinus congregatus grown on a low-temperature-liquifying medium (저온 액화성 응고제를 사용한 고체배지에서 자란 coprinus congregatus의 phenoloxidase들의 localization)

  • ;Ross, Ian K.
    • Korean Journal of Microbiology
    • /
    • 제28권3호
    • /
    • pp.274-277
    • /
    • 1990
  • The hyphal tip phenoloxidases of Coprinus congregatus were localized by the protoplast-concanavalin A method. Protoplast were generated from cultures grown on a solid medium which was solidified with a new gelling agent, Pluronid Polyol F127, instead of agar. the enzymes were associated with the cell membrane which might work as a transducer in the light recepter complex.

  • PDF

Sequential Outage Checkers for Analyzing Cascading Outages and Preventing Large Blackouts

  • Hur, Jin;Joung, Man-Ho;Baldick, Ross
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권5호
    • /
    • pp.585-594
    • /
    • 2011
  • This paper presents the use of sequential outage checkers to identify the potential cascading processes that might lead to large blackouts. In order to analyze cascading outages caused by a combination of thermal overloads, low voltages, and under-frequencies following an initial disturbance, sequential outage checkers are proposed. The proposed sequential outage checkers are verified using the AEP 9-bus system, New England 39-bus system, and IEEE 118-bus system.

An Economic Analysis of Potential Cost Savings from the Use of Low Voltage DC (LVDC) Distribution Network

  • Hur, Don;Baldick, Ross
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권3호
    • /
    • pp.812-819
    • /
    • 2014
  • The proposed technical work attempts to compare the two key technologies of power distribution, i.e. direct current (DC) and alternating current (AC) in a fiscal manner. The DC versus AC debate has been around since the earliest days of electric power. Here, at least four types of a low voltage DC (LVDC) distribution are examined as an alternative to the existing medium voltage AC (MVAC) distribution with an economic assessment technique for a project investment. Besides, the sensitivity analysis will be incorporated in the overall economic analysis model to cover uncertainties of the input data. A detailed feasibility study indicates that many of the common benefits claimed for an LVDC distribution will continue to grow more profoundly as it is foreseen to arise with the increased integration of renewable energy sources and the proliferation of energy storage associated with the enhanced utilization of uninterruptible power supply (UPS) systems.

Aortic Root Replacement with Pulmonary Autograft in Patient with Subaortic Abscess and False Aneurysm in Left Ventricular Outflow Tract -Report of A Case- (동맥근 농양 및 좌심실유출호 가성 심실류 환자에서 폐동맥 자가이식편을 이용한 대동맥근부치환술 -1례 치험 보고-)

  • 장병철
    • Journal of Chest Surgery
    • /
    • 제28권7호
    • /
    • pp.704-707
    • /
    • 1995
  • The use of the patient`s pulmonary valve for replacement of the patient`s diseased aortic valve was introduced and developed by Mr. Donald Ross. The long term benefits of having a normal, fully viable, trileaflet semilunar valve in aortic position was demonstrated. A 38 year old male had histories of failures of previously implanted aortic prosthetic valves twice and evidence of progressive heart failure. At operation, aortic root abscess was found; the abscess extension to adjacent structures and partial valve dehiscence had occurred. The patient underwent replacement of the aortic root with autologous pulmonary valve, autologous pericardial patch repair of left ventricuar outflow tract and recontruction of the right ventricular outflow tract and pulmonary artery with prosthetic valved conduit. Postoperatively, the patient recovered well. Postoperative doppler echocardiography demonstrated minimal central regurgitation in new aortic valve. Aortic root replacement with pulmonary autograft in a patient of recurrent aortic root abscess and false aneurysm of left ventricuar outflow tract was experienced and reported with follow up echocardiography.

  • PDF

A Study on the Sound Transmission Loss Measurement of Sound Isolation Sheets (차음시트의 음향투과손실 측정에 관한 연구)

  • Lee, Dong-Hoon;Kang, Moon;Lee, Ju-Weon;Jung, Gab-Cheol;Kwon, Young-Pil
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.409-414
    • /
    • 2000
  • A new impedance tube method is presented for the measurement of transmission loss of sound isolation sheets. The two-microphone method based on the sound decomposition theory proposed by Seybert and Ross is reviewed in this impedance tube method, which has been used for the determination of absorption coefficient of absorptive materials as well as transmission loss of automotive mufflers. Sound transmission losses for rubber, polyvinyl and asphalt sheets are measured in an impedance tube and reverberation room facility, respectively. By comparing two measurement methods, the reliability of impedance tube method used in this study is validated. From the experimental results, it is shown that the accuracy of sound isolation capability obtained by the impedance tube method depends upon the microphone spacing and the distance of the first microphone from the test sample surface.

  • PDF