Abstract
The use of the patient`s pulmonary valve for replacement of the patient`s diseased aortic valve was introduced and developed by Mr. Donald Ross. The long term benefits of having a normal, fully viable, trileaflet semilunar valve in aortic position was demonstrated. A 38 year old male had histories of failures of previously implanted aortic prosthetic valves twice and evidence of progressive heart failure. At operation, aortic root abscess was found; the abscess extension to adjacent structures and partial valve dehiscence had occurred. The patient underwent replacement of the aortic root with autologous pulmonary valve, autologous pericardial patch repair of left ventricuar outflow tract and recontruction of the right ventricular outflow tract and pulmonary artery with prosthetic valved conduit. Postoperatively, the patient recovered well. Postoperative doppler echocardiography demonstrated minimal central regurgitation in new aortic valve. Aortic root replacement with pulmonary autograft in a patient of recurrent aortic root abscess and false aneurysm of left ventricuar outflow tract was experienced and reported with follow up echocardiography.