• 제목/요약/키워드: RMS detection

검색결과 131건 처리시간 0.025초

초음파를 이용한 감자의 내부결함검사 (Ultrasonic Inspection of Internal Defects of Potatoes)

  • 김인훈;정규홍;장경영;서륜;김만수
    • 한국정밀공학회지
    • /
    • 제20권3호
    • /
    • pp.82-88
    • /
    • 2003
  • The nondestructive internal quality evaluation of agricultural products has been strongly required from the needs for individual inspection. Recently, the ultrasonic wave has been considered as a solution fur this problem, and an ultrasonic system was constructed for the ultrasonic NDE of fruits and vegetables in our previous work. In this paper, the practical applicability of our ultrasonic system is tested fur the inspection of internal defects (central cavity) in Atlantic potato. Sound speed and RMS of transmitted ultrasonic wave signal were measured and classification algorithm using 2 dimensional stochastic analysis. was presented. Experimental results showed greater value of sound speed and RMS (root mean square) of transmitted signal in normal samples than in abnormal samples with cavity. Also a stochastic method to distinguish normal and abnormal showed fault detection rate less than 5%.

평면연삭시 복합검출방법에 의한 숫돌마멸 예측 (Prediction of Wheel Wear when Surface Grinding by Dual Detection Methods)

  • 왕덕현
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 1998년도 춘계학술대회 논문집
    • /
    • pp.172-177
    • /
    • 1998
  • An experimental study on the prediction of grinding wheel wear by dual detection methods was conducted by the laser displacement and acoustic emission(AE) system. The laser displacement sensor was located above the head of the grinding wheel and the AE sensor was set under the workpiece, where the wheel were condition can be detected. It was found that the dual detection methods by laser displacement system and AE system made it possible to predict the wheel wear. From the experiments, the root mean square(RMS) values both methods was found to be proportional to the grinding wheel wear.

  • PDF

배전계통연계 분산전원의 위상변화에 따른 고립운전 파라미터 특성 (A Study on Islandig Characteristics using Phase Angle Adjustment of Distributed Generation)

  • 방지윤;김학만;이복구;심재선;신명재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.525-526
    • /
    • 2006
  • Recently, much research has been done and many improvements have been developed for islanding protection of distributed generation(DG). Anti-islanding protection for DG must be act very quickly to prevent equipment damage at the time of disconnection and for the safety of maintenance and repair personnel. DG-based detection methods have included both passive and active types, and now research has shifted towards new anti-islanding detection methods that make up for the defects of the previous types. Because differences occur between the utility grid and the DG when connecting and disconnecting depending on the phase difference, voltage, current, relative capacity of electric power, and system operation characteristics, voltage phase angle is an important consideration. In this paper, we simulated islanded operation characteristics comparing phase difference of DG and the connected utility grid, and analyzed various parameters (real power, reactive power, RMS voltage, RMS current, power factor angle, and frequency) by varying the DG's voltage phase angle. Using this information, we propose a suitable DG voltage phase angle for enhanced passive islanding detection techniques.

  • PDF

Power Swing Detection Using rms Current Measurements

  • Taheri, Behrooz;Razavi, Farzad
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권5호
    • /
    • pp.1831-1840
    • /
    • 2018
  • During a power swing, distance relays may mistakenly spread fault throughout the power grid, causing a great deal of damage. In some cases, such mistakes can cause global outages. For this reason, it is critical to make a distinction between power swings and faults in distance relays. In this paper, a new method is proposed based on RMS measurement to differentiate between faults and power swings. The proposed method was tested on two standard grids, demonstrating its capability in detecting a power swing and simultaneous fault with power swing. This method required no specific configurations, and was independent of grid type and zoning type of distance relays. This feature in practice allows the relay to be installed on any grid with any kind of coordination. In protective relays, the calculations applied to the microprocessor is of great importance. Distance relays are constantly calculating the current RMS values for protection purposes. This mitigates the computations in the microprocessor to detect power swings. The proposed method was able to differentiate between a fault and a power swing. Furthermore, it managed to detect faults occurring simultaneously with power swings.

가정용 부하에서 발생하는 직렬아크 신호분석 및 검출알고리즘 (A Study on Series Arc Detection Algorithm for the Consumer Appliances)

  • 임종웅;방선배;조영훈;최규하
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2014년도 전력전자학술대회 논문집
    • /
    • pp.351-352
    • /
    • 2014
  • In this paper, series-arc detection algorithm for the consumer appliances is proposed. This algorithm uses varying frequency and RMS values at series-arc state. This is confirmed to emulate arc detecting with measuring current data.

  • PDF

웨이블릿 변환의 검출 특성을 이용한 전압강하 검출에 관한 연구 (A Study for Voltage Sag Detection Using Detection Characteristic Of Wavelet Transform)

  • 정승복;김재철;설규환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.172-174
    • /
    • 2005
  • Recently, a concern of power qualify increases because of electronic device development and well-being generation. Power quality problems such as voltage sag, harmonics, flicker etc. have adverse effects on electric devices. Therefore, power quality problems have been monitored. This paper studies a detection of voltage sag that is more severer than the others. A voltage sag has been monitored using rms or wavelet method. This paper proposes an advance detection method using wavelet. An error Of Start Point differs error of ending point. We use this difference. So, we respectively revise detection error. Also, we revise multiplying average error rate.

  • PDF

K-means 알고리듬을 이용한 비정상 사운드 검출 (Irregular Sound Detection using the K-means Algorithm)

  • 정의필;이재열;조상진
    • 융합신호처리학회논문지
    • /
    • 제6권1호
    • /
    • pp.23-26
    • /
    • 2005
  • 산업 시설 등에서 운전 중인 회전 기계의 동작, 감시, 진단은 설비의 효율적인 운용 및 사고 방지 등을 위해 매우 중요한 일이다. 이상 진단 기술은 기기에 설치된 센서로부터 취득된 데이터의 특징을 추출하는 것과 분류된 데이터를 이용해 정상 또는 이상으로 구분하거나 이상의 원인을 분석하는 두 가지 과정으로 진행할 수 있다. 기존의 기술들은 주파수 분석과 패턴 인식의 방법 등이 적용되어 왔다. 본 논문에서는 운전되고 있는 정상/비정상 상태를 분류하기 위하여 기기들의 사운드 정보를 획득하여 웨이블렛 변환을 거쳐 주파수 대역별 신호를 나누었다. 나누어진 대역별 신호의 RMS값으로 입력벡터를 구성하고 이 입력벡터에 K-means 방법을 적용하여 정상 및 비정상 상태의 모델을 결정한다. 결정된 정상 및 비정상 상태의 모델과 입력 벡터를 비교하여 입력 신호의 정상/비정상을 판단한다.

  • PDF

A 1.248 Gb/s - 2.918 Gb/s Low-Power Receiver for MIPI-DigRF M-PHY with a Fast Settling Fully Digital Frequency Detection Loop in 0.11 ㎛ CMOS

  • Kim, Sang-Yun;Lee, Juri;Park, Hyung-Gu;Pu, Young Gun;Lee, Jae Yong;Lee, Kang-Yoon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제15권4호
    • /
    • pp.506-517
    • /
    • 2015
  • This paper presents a 1.248 Gb/s - 2.918 Gb/s low-power receiver MIPI-DigRF M-PHY with a fully digital frequency detection loop. MIPI-DigRF M-PHY should be operated in a very short training time which is $0.01{\mu}s$ the for HS-G2B mode. Because of this short SYNC pattern, clock and data recovery (CDR) should have extremely fast locking time. Thus, the quarter rate CDR with a fully digital frequency detection loop is proposed to implement a fast phase tracking loop. Also, a low power CDR architecture, deserializer and voltage controlled oscillator (VCO) are proposed to meet the low power requirement of MIPI-DigRF M-PHY. This chip is fabricated using a $0.11{\mu}m$ CMOS process, and the die area is $600{\mu}m{\times}250{\mu}m$. The power consumption of the receiver is 16 mW from the supply voltage of 1.1 V. The measured lock time of the CDR is less than 20 ns. The measured rms and peak jitter are $35.24ps_{p-p}$ and $4.25ps_{rms}$ respectively for HS-G2 mode.

Evaluation of neutron attenuation properties using helium-4 scintillation detector for dry cask inspection

  • Jihun Moon;Jisu Kim;Heejun Chung;Sung-Woo Kwak;Kyung Taek Lim
    • Nuclear Engineering and Technology
    • /
    • 제55권9호
    • /
    • pp.3506-3513
    • /
    • 2023
  • In this paper, we demonstrate the neutron attenuation of dry cask shielding materials using the S670e helium-4 detector manufactured by Arktis Radiation Ltd. In particular, two materials expected to be applied to the TN-32 dry cask manufactured by ORANO Korea and KORAD-21 by the Korea Radioactive Waste Agency (KORAD) were utilized. The measured neutron attenuation was compared with our Monte Carlo N-Particle Transport simulation results, and the difference is given as the root mean square (RMS). For the fast neutron case, a rapid decline in neutron counts was observed as a function of increasing material thickness, exhibiting an exponential relationship. The discrepancy between the experimentally acquired data and simulation results for the fast neutron was maintained within a 2.3% RMS. In contrast, the observed thermal neutron count demonstrated an initial rise, attained a maximum value, and exhibited an exponential decline as a function of increasing thickness. In particular, the discrepancy between the measured and simulated peak locations for thermal neutrons displayed an RMS deviation of approximately 17.3-22.4%. Finally, the results suggest that a minimum thickness of 5 cm for Li-6 is necessary to achieve a sufficiently significant cross-section, effectively capturing incoming thermal neutrons within the dry cask.

Three-Phase PWM-Switched Autotransformer Voltage-Sag Compensator Based on Phase Angle Analysis

  • Mansor, Muhamad;Rahim, Nasrudin Abd.
    • Journal of Power Electronics
    • /
    • 제11권6호
    • /
    • pp.897-903
    • /
    • 2011
  • Many voltage sag compensators have been introduced, including the traditional dynamic voltage restorer (DVR), which requires an energy storage device but is inadequate for compensating deep and long-duration voltage sags. The AC-AC sag compensators introduced next do not require a storage device and they are capable of compensating voltage sags. This type of compensator needs an AC-AC converter to regulate the output voltage. Presented in this paper is a three-phase PWM-switched autotransformer voltage sag compensator based on an AC-AC converter that uses a proposed detection technique and PWM voltage control as a controller. Its effectiveness and capability in instantly detecting and compensating voltage sags were verified via MATLAB/Simulink simulations and further investigated through a laboratory prototype developed with a TMS320F2812 DSP as the main controller.