• Title/Summary/Keyword: RING

Search Result 8,430, Processing Time 0.047 seconds

Effect of Phenolic Mediators and Humic Acid on the Removal of 1-Indanone Using Manganese Oxide (망간산화물(Birnessite)을 이용한 1- Indanone 제거 시 페놀계 반응매개체와 휴믹산(HA) 영향 평가)

  • Choi, Chan-Kyu;Eom, Won-Suk;Shin, Hyun-Sang
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.7
    • /
    • pp.445-453
    • /
    • 2012
  • An investigation for removal of 1-indanone (1-ID), which were commonly produced from the biological and/or chemical treatment and natural weathering of the PAHs-contaminated soils, via oxidative transformation mediated by birnessite in the presence of various phenolic mediators is described. This study also examines the potential effect of the natural occurring substance humic acid (HA) on the oxidative transformation. The experiment was carried out in aqueous phase as a batch test (10 mg/L 1-ID, 0.3 mM phenolic mediators, $1.0g/L\;{\delta}-MnO_2$, at pH 5). All of the 11 tested phenoilic mediators belong to the group of natural occurring phenols and are widely used as model constituents of humic substances. From the results of HPLC analysis, it is demonstrated that 1-ID was not reactive to birnessite itself, but it can be effectively removed in birnessite-mediated cross coupling reactions in the presence of the phenolic mediators. The percent removals of 1-ID after 2 day incubation were ranged from 9.2 to 71.2% depending on the phenolic mediators applied. The initial rate constant ($K_{int}$, $hr^{-1}$) values for the 1-ID removals obtained from the pseudo-first-order kinetic plots also widely ranged from 0.18 to 15.0. Results of the correlative analysis between the removal efficiencies and structural characteristics of phenolic mediators indicate that the transformation of the 1-ID was considerably enhanced by the addition of electron-donating substituents (e.g., -OH, $-OCH_3$) at the benzne ring, and much less enhanced by the addition of electron-withdrawing substituents (e.g., -COOH, -CHO). The presence of HA showed that removal efficiencies of 1-ID in the birnessite-phenolic mediator systems decreased with increasing HA concentrations. However at low concentration of HA (< 2 mg/L), it caused some enhancement in the removals of 1-ID as compared to the control.

Synthesis of Fully Dehydrated Partially Cs+-exchanged Zeolite Y (FAU, Si/Al = 1.56), |Cs45Na30|[Si117Al75O384]-FAU and Its Single-crystal Structure

  • Seo, Sung-Man;Kim, Ghyung-Hwa;Lee, Seok-Hee;Bae, Jun-Seok;Lim, Woo-Taik
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.6
    • /
    • pp.1285-1292
    • /
    • 2009
  • Large single crystals of zeolite, |$Na_{75}$|[$Si_{117}Al_{75}O_{384}$]-FAU (Na-Y, Si/Al = 1.56), were synthesized from gels with composition of 3.58Si$O_2$ : 2.08NaAl$O_2$ : 7.59NaOH : 455$H_2$O : 5.06TEA : 2.23TCl. One of these, a colorless single-crystal was ion exchanged by allowing aqueous 0.02 M CsOH to flow past the crystal at 293 K for 3 days, followed by dehydration at 673 K and 1 ${\times}\;10^{-6}$ Torr for 2 days. The crystal structure of fully dehydrated partially $Cs^+$-exchanged zeolite Y, |$Cs_{45}Na_{30}$|[$Si_{117}Al_{75}O_{384}$]-FAU per unit cell (a = 24.9080(10) $\AA$) was determined by single-crystal X-ray diffraction technique in the cubic space group Fd $\overline{3}$ m at 294(1) K. The structure was refined using all intensities to the final error indices (using only the 877 reflections with $F_o\;>\;4{\sigma}(F_o))\;R_1$ = 0.0966 (Based on F) and $R_2\;=\;0.2641\;(Based\;on\;F^2$). About forty-five $Cs^+$ ions per unit cell are found at six different crystallographic sites. The 2 $Cs^+$ ions occupied at site I, at the centers of double 6-ring (D6Rs, Cs-O = 2.774(10) $\AA$ and O-Cs-O = 88.9(3) and 91.1(3)$^o$). Two $Cs^+$ ions are found at site I’ in the sodalite cavity; the $Cs^+$ ions were recessed 2.05 $\AA$ into the sodalite cavity from their 3-oxygen plane (Cs-O = 3.05(3) $\AA$ and O-Cs-O = 77.4(13)$^o$). Site-II’ positions (opposite single 6-rings in the sodalite cage) are occupied by 7 $Cs^+$ ions, each of which extends 2.04 $\AA$ into the sodalite cage from its 3-oxygen plane (Cs-O = 3.067(11) $\AA$ and O-Cs-O = 80.1(3)$^o$). The 26 $Cs^+$ ions are nearly three-quarters filled at site II in the supercage, being recessed 2.34 $\AA$ into the supercage (Cs-O = 3.273(8) $\AA$ and O-Cs-O = 74.3(3)$^o$). The 4 $Cs^+$ ions are found at site III deep in the supercage (Cs-O = 3.321(19) and 3.08(3) $\AA$), and 4 $Cs^+$ ions at another site III’ (Cs-O = 2.87(4) and 3.38(4) $\AA$). About 30 $Na^+$ ions per unit cell are found at one crystallographic site; The $Na^+$ ions are located at site I’ in the sodalite cavity opposite double 6-rings (Na-O = 2.578(11) $\AA$ and O-Na-O = 97.8(4)$^o$).

List-event Data Resampling for Quantitative Improvement of PET Image (PET 영상의 정량적 개선을 위한 리스트-이벤트 데이터 재추출)

  • Woo, Sang-Keun;Ju, Jung Woo;Kim, Ji Min;Kang, Joo Hyun;Lim, Sang Moo;Kim, Kyeong Min
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.309-316
    • /
    • 2012
  • Multimodal-imaging technique has been rapidly developed for improvement of diagnosis and evaluation of therapeutic effects. In despite of integrated hardware, registration accuracy was decreased due to a discrepancy between multimodal image and insufficiency of count in accordance with different acquisition method of each modality. The purpose of this study was to improve the PET image by event data resampling through analysis of data format, noise and statistical properties of small animal PET list data. Inveon PET listmode data was acquired as static data for 10 min after 60 min of 37 MBq/0.1 ml $^{18}F$-FDG injection via tail vein. Listmode data format was consist of packet containing 48 bit in which divided 8 bit header and 40 bit payload space. Realigned sinogram was generated from resampled event data of original listmode by using adjustment of LOR location, simple event magnification and nonparametric bootstrap. Sinogram was reconstructed for imaging using OSEM 2D algorithm with 16 subset and 4 iterations. Prompt coincidence was 13,940,707 count measured from PET data header and 13,936,687 count measured from analysis of list-event data. In simple event magnification of PET data, maximum was improved from 1.336 to 1.743, but noise was also increased. Resampling efficiency of PET data was assessed from de-noised and improved image by shift operation of payload value of sequential packet. Bootstrap resampling technique provides the PET image which noise and statistical properties was improved. List-event data resampling method would be aid to improve registration accuracy and early diagnosis efficiency.

Crystal Structure of Dehydrated Partially Cobalt(II)-Exchanged Zeolite X, $Co_{41}Na_{10}-X$ (부분적으로 $Co^{2+}$ 이온으로 치환된 제올라이트 X, $Co_{41}Na_{10}-X$를 탈수한 결정구조)

  • Jang, Se-Bok;Jeong, Mi-Suk;Han, Young-Wook;Kim, Yang
    • Korean Journal of Crystallography
    • /
    • v.6 no.2
    • /
    • pp.125-133
    • /
    • 1995
  • The crystal structure of dehydrated, partially Co(II)-exchanged zeolite X, stoichiometry Co2+Na+-X (Co41+Na10Si100Al92O384) per unit cell, has been determined from three-dimensional X-ray diffraction data gathered by counter methods. The structure was solved and refined in the cubic space group Fd3:α=24.544(1)Å at 21(1)℃. The crystal was prepared by ion exchange in a flowing stream using a solution 0.025 M each in Co(NO3)2 and Co(O2CCH3)2. The crystal was then dehydrated at 380℃ and 2×10-6 Torr for two days. The structure was refined to the final error indices, R1=0.059 and R2=0.046 with 211 reflections for which I > 3σ(I). Co2+ ions and Na+ ions are located at the four different crystallographic sites. Co2+ ions are located at two different sites of high occupancies. Sixteen Co2+ ions are located at the center of the double six-ring (site I; Co-O = 2.21(1)Å, O-Co-O = 90.0(4)°) and twenty-five Co2+ ions are located at site II in the supercage. Twenty-five Co2+ ions are recessed 0.09Å into the supercage from its three oxygen plane (Co-O = 2.05(1)Å, O-Co-O = 119.8(7)°). Na+ ions are located at two different sites of occupandies. Seven Na+ ions are located at site II in the supercage (Na-O = 2.29(1)Å, O-Na-O = 102(1)°). Three Na+ ions are statistically distribyted over site III, a 48-fold equipoint in the supercages on twofold axes (Na-O = 2.59(10)Å, O-Na-O = 69.0(3)°). Seven Na+ ions are recessed 1.02Å into the supercage from the three oxygen plane. It appears that Co2+ ions prefer sites I and II in order, and that Na+ ions occupy the remaining sites, II and III.

  • PDF

Strains of abutment and bones on implant overdentures (임플란트 피개의치에서 지대주와 골의 변형률에 관한 연구)

  • Kim, Myung-Seok;Heo, Seong-Joo;Koak, Jai-Young;Kim, Sung-Kyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.222-231
    • /
    • 2009
  • Statements of the problem: Over the past decades, conventional complete dentures were used for various patients although they have incomplete function. Overdentures using dental implants could help the improvement of denture function. Purpose: The purpose of this study was to compare the strains of abutment and bone on implant overdenture between splinted and unsplinted type of prosthesis. Additionally, the strain values of parallel placed implant model and unparallel placed implant model were compared. Material and methods: Two acrylic resin model were prepared and two implants were placed at the canine positions in each model. In the first model, two implant were placed parallel. In the second model, two implants were placed with 10 degree labiolingual divergence. Two types of abutment were connected to the fixtures alternatively. One was splint type of Hader bar, the other was unsplint type of ball abutment. Overdentures were fabricated with corresponding attachment systems and seated on abutments. Strains of abutments and labial bone simulants were measured with electric resistance strain gauges when static load from 100 N to 200 N were applied to overdentures. Results: 1. Splinted type of overdentures using bar and clip showed higher absolute strain values. But the strain was compressive and the load was shared by two implants(P<.05). 2. Unsplinted type overdentures using ball and O-ring showed low absolute strain values(P<.05). 3. Labially inclined implant showed higher tensile strain values in unsplinted type of prosthesis than in splinted type of prosthesis. Lingually inclined implant showed rather low strain values under load(P<.05). 4. Non parallel implant model showed higher absolute strain values than parallel placed implant model comprehensively(P<.05).

Development and Application of a Novel Mammalian Cell Culture System for the Biocompatibility and Toxicity of Polymer Films and Metal Plate Biomaterials (고분자필름과 금속막 의료소재에 대한 생체적합성 및 독성 평가를 위한 새로운 세포배양시스템의 개발 및 적용)

  • Kwak, Moon Hwa;Yun, Woo Bin;Kim, Ji Eun;Sung, Ji Eun;Lee, Hyun Ah;Seo, Eun Ji;Nam, Gug Il;Jung, Young Jin;Hwang, Dae Youn
    • Journal of Life Science
    • /
    • v.26 no.6
    • /
    • pp.633-639
    • /
    • 2016
  • Biomaterials including polymer, metal, ceramic, and composite have been widely applied for medical uses as medical fibers, artificial blood vessels, artificial joints, implants, soft tissue, and plastic surgery materials owing to their physicochemical properties. However, the biocompatibility and toxicity for film- and plate-form biomaterials is difficult to measure in mammalian cells because there is no appropriate incubation system. To solve these problems, we developed a novel mammalian cell culture system consisting of a silicone ring, top panel, and bottom panel and we applied two polymer films (PF) and one metal plate (MP). This system was based on the principal of sandwiching a test sample between the top panel and the bottom panel. Following the assembly of the culture system, SK-MEL-2 cells were seeded onto Styela Clava Tunic (SCT)-PF, NaHCO3-added SCT (SCTN)-PF, and magnesium MP (MMP) and incubated at 37℃ for 24 hr and 48 hr. An MTT assay revealed that cell viability was maintained at a normal level in the SCT-PF culture group at 24 or 48 hr, although it rapidly decreased in the SCTN-PF culture group at 48 hr. Furthermore, the cell viability in the MMP culture group was very similar to that of the control group after incubation for 24 hr and 48 hr. Together, these results suggest the sandwich-type mammalian culture system developed here has the potential for the evaluation of the biocompatibility and toxicity of cells against PF- and MP-form biomaterials.

A Study on the Shaped-Beam Antenna with High Gain Characteristic (고이득 특성을 갖는 성형 빔 안테나에 대한 연구)

  • Eom, Soon-Young;Yun, Je-Hoon;Jeon, Soon-Ick;Kim, Chang-Joo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.1 s.116
    • /
    • pp.62-75
    • /
    • 2007
  • This paper describes a shaped-beam antenna for increasing the antenna gain of a radiating element. The proposed antenna structure is composed of an exciting element and a multi-layered disk array structure(MDAS). The stack micro-strip patch elements were used as the exciter for effectively radiating the electromagnetic power to the MDAS over the broadband, and finite metallic disk array elements - which give the role of a director for shaping the antenna beam with the high gain - were finitely and periodically layered onto it. The efficient power coupling between the exciter and the MDAS should be carried out in such a way that the proposed antenna has a high gain characteristic. The design parameters of the exciter and the MDAS should be optimized together to meet the required specifications to meet the required specifications. In this study, a shaped-beam antenna with high gain was optimally designed under the operating conditions with a linear polarization and the frequency band of $9.6{\sim}10.4\;GHz$. Two methods constructed using thin dielectric film and dielectric foam materials respectively were also proposed in order to implement the MBAS of the antenna. In particular, through the computer simulation process, the electrical performance variations of the antenna with the MDAS realized by the thin dielectric film materials were shown according to the number of disk array elements in the stack layer. Two kinds of antenna breadboard with the MDAS realized with the thin dielectric film and dielectric foam materials were fabricated, but experimentation was conducted only on the antenna breadboard(Type 1) with the MDAS realized with the thin dielectric film materials according to the number of disk array elements in the stack layer in order to compare it with the electrical performance variations obtained during the simulation. The measured antenna gain performance was found to be in good agreement with the simulated one, and showed the periodicity of the antenna gain variations according to the stack layer number of the disk array elements. The electrical performance of the Type 1 antenna was measured at the center frequency of 10 GHz. As the disk away elements became the ten stacks, a maximum antenna gain of 15.65 dBi was obtained, and the measured return loss was not less than 11.4 dB within the operating band. Therefore, a 5 dB gain improvement of the Type 1 antenna can be obtained by the MDAS that is excited by the stack microstrip patch elements. As the disk array elements became the twelve stacks, the antenna gain of the Type 1 was measured to be 1.35 dB more than the antenna gain of the Type 2 by the outer dielectric ring effect, and the 3 dB beam widths measured from the two antenna breadboards were about $28^{\circ}$ and $36^{\circ}$ respectively.

Causes of Under-staging in Patients with Gastric Cancer That was Proven to be Unresectable after a Laparotomy - Correlation with CT Findings (비절제 위암의 원인분석-전산화단층촬영(CT) 소견을 중심으로)

  • Yoon, Hyuk-Jin;Shin, Jung-Hye;Kim, Gab-Chul;Yu, Wan-Sik;Chung, Ho-Young
    • Journal of Gastric Cancer
    • /
    • v.6 no.4
    • /
    • pp.263-269
    • /
    • 2006
  • Purpose: The aim of this study was to investigate the causes of under-staging in patients with advanced gastric cancer that was proven to be unresectable after a laparotomy. Materials and Methods: We retrospectively analyzed 25 gastric cancer patients who had undergone a diagnostic laparotomy between 2001 and 2005. For the preoperative evaluation, spiral CT and multidetector-row CT were performed. We analyzed the clinicopathologic features of patients and compared the image findings and the results of surgery. The causes of under-staging were divided into 3 groups; patient factor, CT factor, and interpretation factor. Results: Grossly, there were 12 cases of Borrmann type-III tumors and 13 cases of Borrmann type-IV tumors. The most frequent histologic type was poorly differentiated adenocarcinomas (8 cases) and signet ring cell carcinomas (7 cases). There were 13 cases of adjacent organ invasion, and the pancreas was the most frequently invaded organ (9 cases). There were 17 cases of peritoneal metastasis, and 3 cases of distant lymph node metastasis. For the cause of under-staging, there were four cases of patient factor, 19 cases of interpretation factor, and 9 cases of CT factor. In three cases, the cause of under-staging could not be identified. Conclusion: CT interpretation factor was the most frequent cause of under-staging in the preoperative diagnosis with gastric cancer patients. Therefore, more cautious CT interpretation is necessary to avoid unnecessary laparotomies in gastric cancer patients.

  • PDF

Analysis of Recurred Mitral Regurgitation after Mitral Repair according to Procedure or Valve Related Causes (승모판막 성형술 후 재발의 원인에 대해 술기와 판막 요인에 대한 분석)

  • Shin Hong Ju;Yoo Dong Gon;Lee Yong Jik;Park Soon Ik;Choo Suk Jung;Song Hyun;Chung Cheol Hyun;Song Meong Gun;Lee Jae Won
    • Journal of Chest Surgery
    • /
    • v.38 no.2 s.247
    • /
    • pp.132-138
    • /
    • 2005
  • Background: Mitral valve repair (MVP) is the optimal procedure for mitral regurgitation (MR), however, failure and subsequent reoperations are the limitations. The current study assessed the procedure in relation to the primary valve related causes of recurrent MR. Material and Method: MR was treated in 493 patients undergoing MVP from January of 1994 to January of 2002. The causes of MR were degenerative $(n=252,\;51.5\%),$ rheumatic $(n=156,\; 31.6\%),$ and others $(n=85,\; 16.9\%).$ Surgery comprised 446 ring annuloplasties $(90.5\%),$ 227 new chordae formations $(46\%),$ 125 quadriangular resections $(25.3\%),$ 28 chordae transfers $(5.7\%),$ and 8 Alfieri's stitches $(1.6\%).$ The mean follow up was $29.04\pm22.81$ months. Result: There were 5 early $(1.01\%)$, and 5 late deaths $(1.01\%).$ The reoperation rate was $1.42\%$. There were 45 $(9.1\%)$ recurrent MR (grade III or IV). Of these, 24 were procedure related including incomplete repair (n=14), discordant new chordae length (n=8) and others (n=2). In 21 patients, the cause was valve related including rheumatic disease progression (n=10), recurrent chordae elongation or prolapse (n=5) and others (n=6). Severe MR was higher after incomplete repair (p < 0.001), and valve related failure strongly correlated with rheumatic progression (p < 0.05). Conclusion: Since completeness of operation is the prime risk factor that determine the repair durability, intra-operative assessment of the initial repair with trans-esophageal echocardiography is essential.

Preservation of Subvalvular Apparatus During Mitral Valve Replacement (판막하부 구조물을 보존하는 인공 승모판막 치환술)

  • 임창영;임정철
    • Journal of Chest Surgery
    • /
    • v.29 no.12
    • /
    • pp.1329-1336
    • /
    • 1996
  • From January, 1994 to January. 1996, mitral valve replacement was performed in 27 patients. Among these, 17 patients underwent mitral valve replacement(MVR) with preservation of the annulo-papillary continuity(PAPCMVR) (-Group I), and 10 patients underwent conventional methods of excision of all the chordae(Group II). The operative technique for PAPCM VR consists of the division of the anterior leaflet into anterior and posterior segments, shifting and reattachment of the divided segments to the mitral ring of the respective commissural areas. This retrospective study has been designed to evalute the postoperative left ventricular function in the two groups. In the group 1, LVEF(Left Vnetricular Ejection Fraction : %) was 52 $\pm$ 3 preoperatively And 50$\pm$3 postoperatively, LVESI Vent icular End Systolic Volume Index/mL/m2) wIns 59 :6 and 51 $\pm$ 7, LVEDI Ventricular End Diastolic Volume Index/mL/m2) was 124$\pm$ 11 and 91 :8. In the group II, LVEF was 56$\pm$1 and 47:), LVESVI 62$\pm$12 and 61$\pm$15, LVEDVI 133$\pm$27 and 104$\pm$17. : the variation of the LVEF in these two group was statistically different(p(0.05). A comparison of left ventricular function data between Group I(n: 17) and Group II(n: 10) revealed better results in echocardiographic LVEF(p<0.05), LVEDVI(p<0.01) in the former group. The mean functional class(UYHA) was 2.6 preoperative and improved to 1.0 postoperatively In group 1, and 2.8 and to 1.0 in group II. We conclude that maintenance of continuity between the mitral annulus and papillary muscles is expected to have a beneficial effect on postoperative left ventricular performance.

  • PDF