• Title/Summary/Keyword: RHIM

Search Result 1,111, Processing Time 0.026 seconds

The Experimental Studies for Reducing Airflow-induced Vibration of Actuator Arms in HDDs (하드디스크 드라이브의 내부 유동에 의한 액추에이터 암의 진동 저감을 위한 연구)

  • Cho, Kwang-Pyo;Yoo, Jin-Gyoo;Rhim, Yoon-Chul
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.670-675
    • /
    • 2003
  • With the increase in recording density and higher rotation speeds, the aerodynamic aspect of hard disk drives (HDDs) is now quite significant. To achieve high TPI (tracks per inch) for hard disk drives, the actuator must induce less air turbulence. Also, alternative cross sections for the actuator arms are proposed for the reduction of air turbulence. In this study, off-track vibration of actuator arms used in of 3.5" hard disk drives with different cross sections have been measured by using Laser Doppler Vibrometer (LDV). It has been found that the vibration of the actuator arms with modified cross sections is lower than the conventional one.

  • PDF

An Experimental Study of Disc Warping in Slim-type Optical Disc Drive (Slim-type 광학식 정보저장기기에서의 디스크 변형에 관한 실험적 연구)

  • Lee, Jae-Sung;Rhim, Yoon-Chul
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.676-681
    • /
    • 2003
  • In this paper, we investigated the disc warping in high-speed slim-type optical disc drive. Recently, the information storage devices are increasing track density and higher rotation speed to enhance their recording capacity and their data transfer rate. Generally, ODD used in the Lap-top Computer has small inner space. So, the flow instability of inner space is rapidly increased as its higher rotation speed. An extreme case, the flow instability causes the malfunction of readout at pick-up of drives. The experiments and numerical analysis were carried out for several cases, the result shows the influence of airflow to the disc warping.

  • PDF

Comparison of the Product Properties between Combustion Analysis and Measurement (보일러 연소해석시와 측정시의 연소가스 중량 및 체적비교)

  • Jang, Suck-Won;Rhim, Sang-Kyu;Jung, Hoon;Lee, In-Cheol
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.368-372
    • /
    • 2003
  • There arc two methods to evaluate the combustion product, that is analysis method and measurement method. Properties of the combustion products, constituents, and quanties, can be used to calculate boiler efficiency and beat losses. Using combustion evaluation methods combustion calculation were performed at certain condition and analyze the results. In this paper by comparing the results between two methods, deviation, correction and possibility of site application were confirmed

  • PDF

Measurement of Ultrasonic Wave Velocity Changes in Silica-Sand Specimens with Voids (공극을 포함한 실리카샌드 시편의 초음파 속도변화 측정)

  • Kim, Dae-You;Rhim, Hong-Chul;Cho, Youn-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.48-49
    • /
    • 2017
  • In order to examine the effect of voids on the ultrasonic wave velocity, specimens made of Silica-Sand with voids were prepared for the measurements. The volume fraction of 0, 15, and 30% of voids were used to compare the differences. Because of its more homogeneous distribution of materials properties, the Silica-Sand specimens were used, as compared to mortar specimens. The results showed clear change in ultrasonic wave velocity with different volume fraction of voids. This result is to be used for the estimation of the integrity of concrete structures using ultrasonic wave velocity method as nondestructive testing.

  • PDF

Experiments on Steel Specimen for Concrete Crack Measurements (콘크리트 균열 탐사를 위한 철제시편 비교 실험)

  • Kim, Dae-You;Rhim, Hong-Chul;Cho, youn-jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.10a
    • /
    • pp.124-125
    • /
    • 2016
  • The various size and shape of cracks in concrete induce deterioration of reinforced concrete structures including nuclear power plants. The wider and deeper the crack is, the concrete structures are more vulnerable to carbonization. Thus, it is essential to develop a reliable measurement technique of cracks inside concrete. In this study, an ultrasonic test method is applied to the crack measurements. The results can be used for evaluation of existing reinforced concrete structures.

  • PDF

Comparing floor height reduction effect of slim floor system with square steel pipe (각형강관을 이용한 슬림플로어 시스템의 층고절감효과 비교)

  • Cho, Youn-Jin;Rhim, Hong-Chul;Kim, Dae-You;Lyu, Seung-Il;Kim, Do-Kyun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.56-57
    • /
    • 2017
  • In recent years, new construction methods have been required to reduce the construction cost and increase the available area in an environment where construction work is frequently performed in a narrow urban area like Korea. As a result of these studies, slim floor composite beam has been suggested. Slim floor composite beam can reduce required depth because web of steel beam is embedded in the slab, so it is effective to reduce floor height and increase the available area. The purpose of this study is the floor height reduction evaluation by comparing system consisting of reinforced concrete, steel, and slim floor using square-shape steel pipe. After doing structural design for a typical plan, checked effectiveness by comparing each design plan. It is proven that slim floor composite beam can reduce required depth effectively comparing required materials of other system.

  • PDF

Non-Supporting Form System for Top-Down Construction (지하 역타 공법용 상·하 분리형 무지주 지지체 개발)

  • Jeong, Mee-Ra;Rhim, Hong-Chul;Yom, Kyong-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2008.05a
    • /
    • pp.27-30
    • /
    • 2008
  • For the purpose of developing economical and time-efficient formwork for Top-down construction, a Non-Supporting Form System has been proposed. The system is consisted of two parts: a hanging part to support a steel frame and a section of concrete slab, and the other hanging part to lower the steel frame. In this paper, the proposed system is compared to two existing systems of Non Supporting Top-down Method and Bracket Supported R/C Downward Method. It is expected that this system can be used in Top-down construction with further development.

  • PDF

Use of Concrete Filled Tube as a Pre-founded Column for Top Down Construction (Top Down 공사에서의 CFT 선기초기둥 활용방안)

  • Kang, Seung-Ryong;Rhim, Hong-Chul;Kim, Seung-Weon;Kim, Dong-Gun;Song, Jee-Yun;Jeong, Mee-Ra;Lee, Hai-Chool
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2008.05a
    • /
    • pp.31-34
    • /
    • 2008
  • Construction of buildings downtown is increasing as much as ever with a strong demand. A Top-Down Method is suitable for its advantage in minimizing its disturbance to the neighborhood. In general, the Pre-founded Column, one of the most important aspects of the Top-Down Method, has been made with an H-Shape Steel Column. However, due to its structural and economical benefits, the usage of CFT(Concrete Filled Tube) columns in the place of Pre-founded Columns is increasing. To promote their applications, we analyze the merits of CFT columns by comparing them with I-Shape columns and propose further research.

  • PDF

Development of Opened Slab Method for Top-Down Construction (지하역타공법용 개방형 슬래브 개발)

  • Song, Jee-Yun;Rhim, Hong-Chul;Kang, Doo-Hyun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2008.05a
    • /
    • pp.43-46
    • /
    • 2008
  • In Top-Down construction for underground structures, the placement of slab as a horizontal supporting member against lateral earth pressure is an important process in determining construction time and cost. Usually, a reinforced concrete perimeter girder distributes concentrated lateral loads from earth retaining structures such as Cast-in-place (CIP) piles. By combining the function of the R/C perimeter girder and horizontal slabs, the Opened Slab Method is efficient for reducing construction time by elimination of time-consuming formwork for traditional perimeter girders. The structural performance of the method is also discussed in this paper.

  • PDF

Analysis of Construction Cases for Sequential PC Stairway Method (RC 계단실 연속화 시공을 위한 PC 계단 공법 현장사례 분석)

  • Lee, Suk-Yong;Rhim, Hong-Chul;Kim, Ook-Jong;Cho, Hong-Duk;Jeong, Mee-Ra
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2008.05a
    • /
    • pp.15-19
    • /
    • 2008
  • The use of Precast Concrete (PC) stairways is increasing to replace existing Reinforced Concrete (RC) stairways for the faster construction and the better quality control. Among several already developed PC stairway construction methods, RC Core Sequential Construction Method by Using PC Stairways (COSEC) has advantages of 1) allowing core of a building to be built prior to PC stairways so that two different procedures will not interfere with each other, and 2) having a newly developed joint connection with the core so that the RC core and PC stairways can be easily put together. In this paper, cases of several construction sites with the PC stairways method are analyzed. The elements of the developed method are described for further application and improvement.

  • PDF