• Title/Summary/Keyword: RF Detector

Search Result 121, Processing Time 0.027 seconds

The Study of Sputtered SiGe Thin Film Growth for Photo-detector Application (광검출기 응용을 위하여 스퍼터된 미세결정 SiGe 박막성장 연구)

  • Kim, Do-Young;Kim, Sun-Jo;Kim, Hyung-Jun;Han, Sang-Youn;Song, Jun-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.6
    • /
    • pp.439-444
    • /
    • 2012
  • For the application of photo-detector as active layer, we have studied how to deposit SiGe thin film using an independent Si target and Ge target, respectively. Both targets were synthesized by purity of 99.999%. Plasma generators were generated by radio frequency (rf, 13.56 MHz) and direct current (dc) power. When Ge and Si targets were sputtered by dc and rf power, respectively, we could observe the growth of highly crystalline Ge thin film at the temperature of $400^{\circ}C$ from the result of raman spectroscopy and X-ray diffraction method. However, SiGe thin film did not deposit above method. Inversely, we changed target position like that Ge and Si targets were sputtered by rf and dc power, respectively. Although Ge crystalline growth without Si target sputtering deteriorated considerably, the growth of SiGe thin film was observed with increase of Si dc power. SiGe thin film was evaluated as microcrystalline phase which included (111) and (220) plane by X-ray diffraction method.

A Study on Measurement and Analysis of Pilot Channel Power at CDMA Communication Network (CDMA통신망에서 파일롯 채널전력 측정 및 분석에 관한 연구)

  • Jeong, Ki-Hyeok;Ra, Keuk-Hwan
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.6 s.360
    • /
    • pp.31-39
    • /
    • 2007
  • In this paper, a system for real-time or periodic measurement and analysis of RF parameters such as forward transmit power and pilot power in CDMA base station systems is proposed. Such RF characteristic parameter measurement can be prevented from system fault and used to achieve optimal service quality and maximum investment return through cell coverage expansion, subscriber capacity increase and so on. For forward power measurement, the local oscillator frequency for the detector is varied so that the transmit power for all channels can be measured. The channel power measurement can be used to analyze the variation in transmit power for changes in voice traffic. By comparing to forward $E_c/I_o$, the pilot channel power can be deducted, which can be used to determine uy degradation in transmit section modules such as the high dover amplifier. Since an accurate analysis of carefully measured data using the CDMA level detector must be made, the system is designed so that measurement errors due to changes in crest factor with modulation method can be overcome.

Efficient DC Power Management Scheme using 60-GHz Rectenna (60-GHz 렉테나를 이용한 효율적 DC 전력 관리 체계)

  • Lim, Sung-Joon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.6
    • /
    • pp.1032-1035
    • /
    • 2008
  • In this paper, a DC power management scheme is proposed for efficient battery operation of 60-GHz receivers. It consists of a rectenna and a zero-cross detector. The harmonic rejection capability of a circular sector antenna is used to simplify the rectenna. The zero-cross detector is introduced to increase sensitivity. When the received power density is larger than 0.013 $mW/cm^2$, it can generate enough DC power to activate an RF receiver. Experimental data is used to verify the proposed idea.

A Research on the Vehicle Detecting Using Earth Magnetic Field Sensor (지자기 센서를 이용한 차량감지 관한 연구)

  • Kang, Moon-Ho;Jeong, Dae-Yeon
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1239-1241
    • /
    • 2001
  • This research addresses a new vehicle detecting scheme which uses MR(Megneto Resistive) sensor. A vehicle detector which includes two MR sensors for detecting car presence and speed, sensor voltage amplifiers, signal processor, microprocessor, RF data transceiver and a simple car moving simulator is constructed. From experimental results with the vehicle detector the proposed vehicle detecting scheme was verified.

  • PDF

RF front-end Module for On-Line UHF Partial-discharge Monitoring System

  • Lee June Young;Kim Bok Ki
    • Proceedings of the IEEK Conference
    • /
    • 2004.08c
    • /
    • pp.776-779
    • /
    • 2004
  • A RF front-end module is designed for GIS(Gas Insulated Substation) which is employed for effective and efficient very high voltage transmission. Major advantage of the unit is improved PO detection sensitivity through minimizing the effect of surrounding interference signals, which is achieved by controlling the gain and the selection of the frequency band, for the precise detection of any UHF PO (Partial Discharge) disturbance occurred in the GIS due to some unwanted problems. For the development of the module, various switches for providing selected signal paths, wideband LNA, 3 BPF for selecting detection frequency band, and video detector are designed, fabricated and measured on 1 mm FR4 substrate with various RF components. The detection sensitivity of the unit was <-60 dBm that is sufficient to detect UHF PO signals as low as 1 pC. It is believed that the value is enough to detect the signal occurred in GIS.

  • PDF

Review of low-noise radio-frequency amplifiers based on superconducting quantum interference device

  • Lee, Y.H.;Chong, Y.;Semertzidis, Y.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.16 no.4
    • /
    • pp.1-6
    • /
    • 2014
  • Superconducting quantum interference device (SQUID) is a sensitive detector of magnetic flux signals. Up to now, the main application of SQUIDs has been measurements of magnetic flux signals in the frequency range from near DC to several MHz. Recently, cryogenic low-noise radio-frequency (RF) amplifiers based on DC SQUID are under development aiming to detect RF signals with sensitivity approaching quantum limit. In this paper, we review the recent progress of cryogenic low-noise RF amplifiers based on SQUID technology.

Determination of Ginseng Saponins by Reversed-Phase High Performance Liquid Chromatography (역상 고속액체크로마토그라피를 이용한 홍삼 사포닌의 정량)

  • Kim, Cheon-Suk;Kim, Se-Bong
    • Korean Journal of Medicinal Crop Science
    • /
    • v.9 no.1
    • /
    • pp.21-25
    • /
    • 2001
  • Major saponins in ginseng were analysed using reverse phase high performance liquid chromatography with binary mobile phase gradient control system instead of normal phase column. The optimum condition were as following : reverse phase column; ${\mu}{\beta}ondapak\;C_{18}$ column (Waters, $3.9mm{\times}300\;mm,\;5{\mu}m$), methyl cyanaide/water binary mobile phase gradient control system, solvent flow rate; 1.5 ml/min, and UV($203{\mu}m$ ) detector. The complete separation of ginsenoside $Rb_1,\;Rb_2,\;Rc,\;Rd,\;Re,\;Rf\;and\;Rg_1$ was achieved within 55 min. The Regression coefficients of the calibration curves for seven ginsenosides were 0.99.

  • PDF

Corrosion Detection of ACSR Power Lines Using Non-Destructive Test Method (비파괴 탐상에 의한 ACSR 전선의 결함 검출)

  • Kang, J.W.;Jang, T.I.;Min, B.W.;Kim, B.K.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1712-1714
    • /
    • 2001
  • This paper deals with the development and application of an inner corrosion detector for the ACSR(Aluminum Conductor Steel Reinforced) power lines. The detector runs on an ACSR power line and inspects the inner corrosion of the conductor using the technology of the nondestructive eddy current test. It is consists of an ECT sensor, signal processing units, a RF transmitter/receiver, and etc.. The experimental result through field tests shows the detector can efficiently find both the zinc and aluminum loss of ACSR power lines.

  • PDF

The development of the ACSR corrosion detector using eddy current sensor with removable type (착탈형 구조를 갖는 와류센서를 이용한 ACSR전선 부식검출기 개발)

  • Kang, J.W.;Cho, S.B.;Jeong, J.K.;Yang, B.M.;Min, B.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2371-2373
    • /
    • 1999
  • This paper deals with the development, reliability, specification and performances of the ACSR inner corrosion detector system. It is designed to run on ACSR automatically and to inspect the corrosion of the line with on-line continuously. And it comprises a sensor a constant current source, a signal processing unit, a RF transmitter and receiver unit. Also separable encircling coil sensor is proposed in order to detect inner corrosion of the overhead ground wires. In conclusion, this detector can realize the nondestructive detecting of an ACSR inner corrosion.

  • PDF

Zinc Loss Detection in ACSR Power Lines using the Removable Type of Eddy Current Sensor (착탈형 와류센서를 이용한 ACSR전선의 아연손실량 검출)

  • Jang, T.I.;Jo, S.B.;Kang, J.W.;Kang, Y.W.;Yang, B.M.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1963-1965
    • /
    • 2000
  • This paper deals with a problem of detecting the inner corrosion of the ACSR(Aluminum Conductor Steel Reinforced) power lines using a detector which consists of an ECT(Eddy Current Test) sensor, a constant current service, a signal processing unit, and a RF transmitter/receiver unit. The detector runs on the ACSR transmission line and inspects the corrosion of the conductor using the technic of the nondestructive eddy current test. The experimental result shows this detector can efficiently find the zinc loss in ACSR power lines.

  • PDF