• Title/Summary/Keyword: RC Structure

Search Result 945, Processing Time 0.027 seconds

Seismic Analysis of Underground RC Box considering Elastoplastic Interface Element (탄소성 경계면 요소를 고려한 지하 철근콘크리트 박스의 내진 해석)

  • 남상혁;송하원;변근주
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2002.03a
    • /
    • pp.109-116
    • /
    • 2002
  • Since experimental evaluation of underground RC structures considering interaction with surrounding soil medium is quite difficult to be simulated, the evaluation for the underground RC structures using an analytical method can be applied very usefully. For underground structures interacted with surrounding soils, it is important to consider path-dependent RC constitutive model, soil constitutive model, and interface model between structure and soil, simultaneously. In this paper, an elastoplastic interface model which consider thickness of interface is proposed and applied for the analysis considering the interaction. Failure mechanism of underground RC box of two story and two box subway station under seismic action is obtained and the effects of ductility of intermediate column to entire underground RC system are investigated through analysis.

  • PDF

A Study on the Comparative Analysis of Chloride Penetration Durability Design Program of Reinforced Concrete Structures. (RC구조물 염해 내구성 설계 평가 프로그램 문헌 비교연구)

  • Lee, Hyung-Min;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.11a
    • /
    • pp.259-260
    • /
    • 2012
  • As RC structures in the marine environment rapidly increase, the interest and the importance of Chloride Penetration durable design have been growing. However, there is hardly any domestic Chloride Penetration durability of RC structures designed analysis programs. Currently, Chloride Penetration durable design method is studied and launched actively as a program in the United States, Europe, Japan and etc., but it is limited to Chloride Penetration durability of RC structures excluded from maintenance construction. Also, the level of dependence on the foreign technology is high; the foreign program is imported and used when needed. The main objective is to compare and to evaluate with the durability assessment program and several conditions when considering the design of Chloride Penetration durability through the programs developed abroad.

  • PDF

Optimum RC Member Design with Predetermined Discrete Sections (단면 데이타 베이스에 의한 RC부재의 최적설계)

  • 최창근;곽효경
    • Computational Structural Engineering
    • /
    • v.2 no.1
    • /
    • pp.79-86
    • /
    • 1989
  • This paper concentrates on the development of simplified and effective algorithm for optimum reinforced concrete(RC) member design. After constructing the data base of predetermined RC sections which are arranged in the order of increasing resistant capacity, the relationship between the section identification numbers and resistant capacities of sections is estabilished by regression and it can be used to obtain the initial solution(section) which satisfies the design constraints imposed. Assuming that there exists the optimum solution. The optimization of the entire structure is accomplished through the individual mumber optimization.

  • PDF

An Evaluation of Structural Performance of Reinforced Concrete Column Retrofitted with Grid Type Unit Details of Jacketing Method under Loading Patterns (격자형 유닛 상세를 가진 단면증설공법으로 보강된 철근콘크리트 기둥의 하중가력패턴에 따른 구조성능평가)

  • Moon, Hong Bi;Ro, Kyong Min;Lee, Young Hak
    • Journal of Korean Association for Spatial Structures
    • /
    • v.22 no.2
    • /
    • pp.29-37
    • /
    • 2022
  • The collapse of reinforced concrete (RC) frame buildings is mainly caused by the failure of columns. To prevent brittle failure of RC column, numerous studies have been conducted on the seismic performance of strengthened RC columns. Concrete jacketing method, which is one of the retrofitting method of RC members, can enhance strength and stiffness of original RC column with enlarged section and provide uniformly distributed lateral load capacity throughout the structure. The experimental studies have been conducted by many researchers to analyze seismic performance of seismic strengthened RC column. However, structures which have plan and vertical irregularities shows torsional behavior, and therefore it causes large deformation on RC column when subjected to seismic load. Thus, test results from concentric cyclic loading can be overestimated comparing to eccentric cyclic test results, In this paper, two kinds of eccentric loading pattern was suggested to analyze structural performance of RC columns, which are strengthened by concrete jacketing method with new details in jacketed section. Based on the results, it is concluded that specimens strengthened with new concrete jacketing method increased 830% of maximum load, 150% of maximum displacement and changed the failure modes of non-strengthened RC columns.

Collapse Simulations of High-Rise RC Building Using ELS Software and Application of Explosive Demolition Methods to Transition Process Analysis from Local Damage to Progressive Collapse (ELS를 이용한 고층 RC 빌딩의 붕괴해석 및 발파해체해석 기법의 국부손상-연쇄붕괴 전이과정 해석에 응용)

  • Kim, Hyon-Soo;Park, Hoon;Kim, Seung-Kon;Lee, Yeon-Gyu;Cho, Sang-Ho
    • Explosives and Blasting
    • /
    • v.29 no.2
    • /
    • pp.1-12
    • /
    • 2011
  • Progressive collapse analyses of high-rise buildings subjected to abnormal loading such as fires, impacts, earthquakes, typhoon, bomb blasts etc. are intended. However it is difficult to perform collapse experiments of the real scale building to determine the capacity of the structure under an extreme loading events. In this study, collapse behavior of a 15 story RC structure building loaded by external explosion pressures were simulated using Extreme Loading Structures (ELS) software. The standoff distance between the RC building and explosives of 1500 kg was 1, 2, 5, 10, and 15 meters. The explosive demolition analysis techniques based on removal of partial support structures following blast scenario was adapted to investigate the transition process of progressive collapse-local damage.

Strengthening RC frames subjected to lateral load with Ultra High-Performance fiber reinforced concrete using damage plasticity model

  • Kota, Sai Kubair;Rama, J.S. Kalyana;Murthy, A. Ramachandra
    • Earthquakes and Structures
    • /
    • v.17 no.2
    • /
    • pp.221-232
    • /
    • 2019
  • Material non-linearity of Reinforced Concrete (RC) framed structures is studied by modelling concrete using the Concrete Damage Plasticity (CDP) theory. The stress-strain data of concrete in compression is modelled using the Hsu model. The structures are analyzed using a finite element approach by modelling them in ABAQUS / CAE. Single bay single storey RC frames, designed according to Indian Standard (IS):456:2000 and IS:13920:2016 are considered for assessing their maximum load carrying capacity and failure behavior under the influence of gravity loads and lateral loads. It is found that the CDP model is effective in predicting the failure behaviors of RC frame structures. Under the influence of the lateral load, the structure designed according to IS:13920 had a higher load carrying capacity when compared with the structure designed according to IS:456. Ultra High Performance Fiber Reinforced Concrete (UHPFRC) strip is used for strengthening the columns and beam column joints of the RC frame individually against lateral loads. 10mm and 20mm thick strips are adopted for the numerical simulation of RC column and beam-column joint. Results obtained from the study indicated that UHPFRC with two different thickness strips acts as a very good strengthening material in increasing the load carrying capacity of columns and beam-column joint by more than 5%. UHPFRC also improved the performance of the RC frames against lateral loads with an increase of more than 3.5% with the two different strips adopted. 20 mm thick strip is found to be an ideal size to enhance the load carrying capacity of the columns and beam-column joints. Among the strengthening locations adopted in the study, column strengthening is found to be more efficient when compared with the beam column joint strengthening.

Flexural Behavior of Layered RC Slabs, which Bio-Mimics the Interface of Shell Layers, Produced by Using 3D Printable Highly Ductile Cement Composite (3D 프린팅용 고연성 시멘트 복합체를 활용한 패류 껍질층 경계면 모방형 적층 RC 슬래브의 휨 거동)

  • Chang-Jin Hyun;Ki-Seong Kwon;Ji-Seok Seo;Yun-Yong Kim
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.28 no.1
    • /
    • pp.90-97
    • /
    • 2024
  • In this study, we employed Highly Ductile Cement Composite (HDCC) to evaluate the flexural performance of a RC slab that simulates the laminating structure of a seashell. To evaluate flexural performance, we produced conventional RC slab specimens, HDCC slab specimens, and HDCC-M slab specimens which biomimics a seashell's layered structure by inserting PE mesh inside the slab made of HDCC. A series of 4-point bending tests were conducted. Experimental results shows the flexural strength of the HDCC-M slab specimen was 1.7 times and 1.2 times higher than that of the RC and HDCC slab specimens, respectively. Furthermore, the ductility was evaluated using the ratio of yield deflection to maximum deflection, and it was confirmed that the HDCC slab test specimen exhibited the best ductility. This is most likely due to the fact that the inserted PE mesh separates the layers and increases ductility, while the HDCC passing through the mesh prevents the loss of load carrying capacity due to layer separation.

Classification of Explosive Demolition Methods Based on the Building Type and Dimension of Wall-slab Apartment Building (벽식 아파트의 주동 형태 및 규모에 따른 발파해체공법 분류)

  • Park, Hoon;Suk, Chul-Gi
    • Explosives and Blasting
    • /
    • v.27 no.2
    • /
    • pp.19-25
    • /
    • 2009
  • According to increasing demands for a redevelopment of a wall-slab structure apartment, new explosive demolition methods, which are different from those for RC structure apartment, are requested. In this study, to provide basic design data on explosive demolition of wall-slab structure apartment, wall-slab structure apartments were classified according to building types and dimensions. Also adequate explosive demolition methods for wall-slab structure apartment are analyzed by using blasting pattern factors such as height(H), breadth(B) and length(L) of apartment.

A study on the Probabilistic Carbonation Progress for Existing RC Structure Apartment by Surface Finishing Materials (표면 마감재를 시공한 RC조 아파트의 확률론적 탄산화 평가 연구)

  • Lee, Hyung-Min;Min, Sang-Ho;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.7-8
    • /
    • 2017
  • As the importance of maintenance of reinforced concrete structure recently has emerged, the attention of durability of structure has been increasing. There are many studies about durability decline especially due to the carbonation. In order to study carbonation progress after surface repair of carbonated concrete, each carbonation penetration velocity from different repair materials of concrete structure is compared through the experiment of carbonation accelerating CO2 concentration to 5%. As carbonation infiltration progress is predicted through this study, the counterplan of service life evaluation will be prepared on selection of repair materials of concrete structure.

  • PDF

Seismic Analysis for RC Framed Structure considering Hysteretic Behavior of Beam-Column Joint (보-기둥 접합부의 이력거동을 고려한 RC 평면골조의 내진해석)

  • 윤정배;조용부;김영곤;우종열
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.599-604
    • /
    • 2000
  • The analytical studies for the test results are presented. From experimental envelope curve, hysteretic behaviors under cyclic loading are modelled for beam-column subassemblages. Modelled curves show relatively good reproduction or experimental curves. finally, seismic performances are investigated for 7 story plain framed structure by nonlinear dynamic analysis. The resulting responses are different by each beam-column joint design.

  • PDF