Browse > Article
http://dx.doi.org/10.9712/KASS.2022.22.2.29

An Evaluation of Structural Performance of Reinforced Concrete Column Retrofitted with Grid Type Unit Details of Jacketing Method under Loading Patterns  

Moon, Hong Bi (Dept. of Architecture engineering, Kyung Hee University)
Ro, Kyong Min (Dept. of Architecture engineering, Kyung Hee University)
Lee, Young Hak (Dept. of Architecture engineering, Kyung Hee University)
Publication Information
Journal of Korean Association for Spatial Structures / v.22, no.2, 2022 , pp. 29-37 More about this Journal
Abstract
The collapse of reinforced concrete (RC) frame buildings is mainly caused by the failure of columns. To prevent brittle failure of RC column, numerous studies have been conducted on the seismic performance of strengthened RC columns. Concrete jacketing method, which is one of the retrofitting method of RC members, can enhance strength and stiffness of original RC column with enlarged section and provide uniformly distributed lateral load capacity throughout the structure. The experimental studies have been conducted by many researchers to analyze seismic performance of seismic strengthened RC column. However, structures which have plan and vertical irregularities shows torsional behavior, and therefore it causes large deformation on RC column when subjected to seismic load. Thus, test results from concentric cyclic loading can be overestimated comparing to eccentric cyclic test results, In this paper, two kinds of eccentric loading pattern was suggested to analyze structural performance of RC columns, which are strengthened by concrete jacketing method with new details in jacketed section. Based on the results, it is concluded that specimens strengthened with new concrete jacketing method increased 830% of maximum load, 150% of maximum displacement and changed the failure modes of non-strengthened RC columns.
Keywords
Concrete jacketing; Seismic strengthening; Torsion; Uni eccentric loading; Bi eccentric loading;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 Sadeghian, P., Rahai, A. R., & Ehsani, M. R. , "Experimental study of rectangular RC columns strengthened with CFRP composites under eccentric loading", Journal of Composites for Construction, Vol.14, No.44, pp.443-450, 2010, doi: 10.1061/(ASCE)CC.1943-5614.0000100   DOI
2 Sakr, M. A., El Korany, T. M., & Osama, B., "Analysis of RC columns strengthened with ultra-high performance fiber reinforced concrete jackets under eccentric loading", Engineering Structures, vol.220, 2020, doi:10.1016/j.engstruct.2020.111016   DOI
3 ACI committee, Building code requirements for structural concrete and commentary (ACI318-19), American Concrete Institute, 2019.
4 Rodrigues, H., Furtado, A., & Arede, A., "Behavior of rectangular reinforced-concrete columns under biaxial cyclic loading and variable axial loads", Journal of Structural Engineering, Vol.142, No.1, 2016, doi:10.1061/(ASCE)ST.1943-541X.0001345   DOI
5 Yoo, S. H., & Kim, D. G., "Analytical study on the seismic retrofit method of irregular piloti building using knee-brace", Journal of the Korea institute for structural maintenance and inspection, Vol.24, No.1, pp.35-42, 2020, doi: 10.11112/jksmi.2020.24.1.35   DOI
6 Moon, H. B., Lee, J. I., & Lee, Y. H., "An evaluation of structural performance of reinforced concrete column retrofitted with grid type unit details of jacketing method", Journal of Korean Association for Spatial Structures, Vol.22, No.1 pp.41-49, 2022, doi:10.9712/KASS.2022.22.1.41   DOI
7 ACI committee, Acceptane criteria for moment frames based on structural testing and commentary(ACI374.1-05), American Concrete Institute, 2005.
8 Thermou, G. E., Papanikolaou, V. K., & Kappos, A. J., "Flexural behaviour of reinforced concrete jacketed columns under reversed cyclic loading". Engineering Structures, Vol.76, pp.270-282, 2014, doi:10.1016/j.engstruct.2014.07.013   DOI