임플랜트 표면 처리 방법에 따른 골조직 반응에 대한 연구 (ON THE BONE TISSUE REACTION TO IMPLANTS WITH DIFFERENT SURFACE TREATMENT METHODS)

  • 김용재;조인호
    • 대한치과보철학회지
    • /
    • 제45권1호
    • /
    • pp.71-84
    • /
    • 2007
  • Statement of problem: Implant surface characteristics plays an important role in clinical success and many studies have been made for improvement of success by changing surface roughness. Purpose: Appropriate increase of surface roughness increases the activity of osteoblast and enhance contact and retention between bone and implant. Material and method- Machined, SLA and RBM surface implants, which are the most commonly used implants were implanted into the tibia of rabbits and after 1 week, 4 weeks, 8 weeks and 12 weeks there were histologic and histomorphometric analysis and study for bone gradient and change of Ca/P ratio using EDS(Energy Dispersive X-ray Spectroscope). Results: Comparison of bone-implant contact showed no significant difference among each implant. In comparison of bone area rates, SLA showed higher value with significant difference at 1 week and 4 weeks, and SLA and RBM at 8 weeks than Machined implant (p<0.05). In analysis of bone constituents with EDS, titanium was specifically detected in new bones and the rates were constant by surface treatment method or period. In case of Ca/P ratio, according to surface treatment method, each group showed significant difference. Lots of old bone fragments produced during implantation remained on the rough surface of RBM implant surface and each group showed histological finding with active synthesis of collagen fibers until 12 weeks. In transmission electronic microscopic examination of sample slice after elapse of twelve weeks, tens nm of borderline (lamina limitans like dense line)was seen to contact the bone, on the interface between bone and implant. Conclusion: SLA and RBM implant with rough surface shows better histomorphometrical result and the trend of prolonged bone formation and maturation in comparison with Machined implant. In addition, implant with rough surface seems to be helpful in early stage bone formation due to remaining of old bone fragments produced in implantation. From the results above, it is considered to be better to use implant with rough surface in implantation.

Bone cutting capacity and osseointegration of surface-treated orthodontic mini-implants

  • Kim, Ho-Young;Kim, Sang-Cheol
    • 대한치과교정학회지
    • /
    • 제46권6호
    • /
    • pp.386-394
    • /
    • 2016
  • Objective: The objective of the study was to evaluate the practicality and the validity of different surface treatments of self-drilling orthodontic mini-implants (OMIs) by comparing bone cutting capacity and osseointegration. Methods: Self-drilling OMIs were surface-treated in three ways: Acid etched (Etched), resorbable blasting media (RBM), partially resorbabla balsting media (Hybrid). We compared the bone cutting capacity by measuring insertion depths into artificial bone (polyurethane foam). To compare osseointegration, OMIs were placed in the tibia of 25 rabbits and the removal torque value was measured at 1, 2, 4, and 8 weeks after placement. The specimens were analyzed by optical microscopy, scanning electron microscopy (SEM), and energy dispersive X-ray spectroscopy (EDS). Results: The bone cutting capacity of the etched and hybrid group was lower than the machined (control) group, and was most inhibited in the RBM group (p < 0.05). At 4 weeks, the removal torque in the machined group was significantly decreased (p < 0.05), but was increased in the etched group (p < 0.05). In the hybrid group, the removal torque significantly increased at 2 weeks, and was the highest among all measured values at 8 weeks (p < 0.05). The infiltration of bone-like tissue surface was evaluated by SEM, and calcium and phosphorus were detected via EDS only in the hybrid group. Conclusions: Partial RBM surface treatment (hybrid type in this study) produced the most stable self-drilling OMIs, without a corresponding reduction in bone cutting capacity.

The effect of pretreating resorbable blast media titanium discs with an ultrasonic scaler or toothbrush on the bacterial removal efficiency of brushing

  • Koh, Minchul;Park, Jun-Beom;Jang, Yun-Ji;Ko, Youngkyung
    • Journal of Periodontal and Implant Science
    • /
    • 제43권6호
    • /
    • pp.301-307
    • /
    • 2013
  • Purpose: This in vitro study was performed to assess the adherence of Porphyromonas gingivalis to a resorbable blast media (RBM) titanium surface pretreated with an ultrasonic scaler or toothbrush and to evaluate the effects of the treatment of the RBM titanium discs on the bacterial removal efficiency of brushing by crystal violet assay and scanning electron microscopy. Methods: RBM titanium discs were pretreated with one of several ultrasonic scaler tips or cleaned with a toothbrush. Then the titanium discs were incubated with P. gingivalis and the quantity of adherent bacteria was compared. The disc surfaces incubated with bacteria were brushed with a toothbrush with dentifrice. Bacteria remaining on the disc surfaces were quantified. Results: A change in morphology of the surface of the RBM titanium discs after different treatments was noted. There were no significant differences in the adherence of bacteria on the pretreated discs according to the treatment modality. Pretreatment with various instruments did not produce significant differences in the bacterial removal efficiency of brushing with dentifrice. Conclusions: Within the limits of this study, various types of mechanical instrumentation were shown to cause mechanical changes on the RBM titanium surface but did not show a significant influence on the adherence of bacteria and removal efficiency of brushing.

임플란트 표면에 따른 인공치면세균막 형성에 관한 연구 (THE STUDY OF THE DENTAL PLAQUE FORMATION ON DIFFERENT IMPLANT SURFACES)

  • 김진우;한세진;김경욱
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제34권3호
    • /
    • pp.325-340
    • /
    • 2008
  • The purpose of this study was to evaluate the artificial dental plaque by Streptococcus mutans on 4 different implant surfaces. In this study, the specimens were divided into 4 groups according to implant surface treatment. Uncoated implant group(n=5) which has an uncoated, smooth surfaced implant(Osstem, Korea), SLA implant group(n=5) which has an sandblasted large grit and acid-etched surface implant(Bicon, USA). Oxidized implant group(n=5) which has an oxidized surfaced implant (Osstem, Korea), and RBM implant group(n=5) which has resorbable blasting media(RBM) surfaced implant(Osstem, Korea). Acquired pellicle by human saliva and dental plaque by Streptococcus mutans were made on each implant surface. To analyze the plaque condition on implants surfaces, cell count and optical density were taken as a microbiologic method, and SEM(Scanning Electronic Microscope) findings was also taken for evaluation of surface condition. The following results were obtained. 1. Cell counting results of artificial dental plaque were Uncoated group($658.0{\pm}102.0$), RBM group($878.0{\pm}170.0$), SLA group ($946.0{\pm}42.0$), Oxidized group($992.0{\pm}40.0$), and there was difference between Oxidized group and Uncoated implant group(p<0.05). In case of modified cell counting results by v/w% were RBM group($197.8{\pm}45.2$), Oxidized group($207.04{\pm}8.34$), Uncoated group($261.6{\pm}40.6$), SLA group($315.4{\pm}14.0$), and there was difference between RBM group and SLA group(p<0.05). 2. Optical density results of artificial dental plaque after ultrasonic treatment was that there was difference among groups, and optical density of RBM group was higher than that of Uncoated group(p<0.05). In case of modified optical density results by v/w%, there was difference among groups, and the modified optical density of Uncoated group and SLA group was higher than those of Oxidized group and RBM group(P>0.05). 3. SEM findings of artificial dental plaque on the surfaces of implant as follows; there were artificial dental plaque on the surfaces of all test implants. Streptococcus mutans and by-product were observed at 10,000 times magnified condition on all test implants. Adhesion area of artificial dental plaque was about 1/2 of total surface after 24 hours incubate at $37^{\circ}C$. These results showed that there were differences among implant surfaces on the growth of Streptococcus mutans, and bacteria and by-product were covered about 1/2 area of total implant surfaces at 24 hours incubate at $37^{\circ}C$.

RBM 처리된 임플란트 표면의 인공치태 제거 효과 연구 (COMPARATIVE STUDY OF REMOVAL EFFECT ON ARTIFICIAL PLAQUE FROM RBM TREATED IMPLANT)

  • 박재완;국민석;박홍주;;최충호;홍석진;오희균
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제29권4호
    • /
    • pp.309-320
    • /
    • 2007
  • Purpose: This study was to evaluate the removal effect on artificial plaque from RBM treated implant surfaces that are exposed due to peri-implantitis. Materials and methods: Artificial plaque with Streptococcus mutans and acquired pellicle adhered to RBM treated implant discs. Study materials divided into one control and six test groups. In test groups, physical and chemical methods used to remove plaques. Prophyflex, Professional Mechanical Tooth Cleaning (PMTC) and interdental brush as mechanical treatments and 0.1% Chlorhexidine, Citric acid, HCl tetracycline as a chemical treatment were used. To analyses the study, disc weight was measured for remaining plaque quantities and SEM(Scanning Electronic Microscope) findings was taken for evaluation of surfaces. Results: 1. In weight changes, there was significant difference between each treatment group and the control group (p<0.05). Therefore all treatment methods using this study have good ability for remove plaques. 2. In weight changes, there was no significant difference between mechanical and chemical group, and there were no significant differences between each groups (p>0.05). 3. SEM findings after mechanical treatment disclosed as follows; Prophyflex group looked like sound implant surface, and there were some paste on implant surface at PMTC group, and there were some artificial plaque at interdental brush group. 4. SEM findings after chemical treatment disclosed as follows; there were some dark lesions which were supposed as the product from Streptococcus mutans at Chlorhexidine, Citric acid and HCl tetracycline groups. Conclusion: All six methods using in this study have good ability to remove artificial plaque on RBM treated implant. According to SEM findings, prophyflex is a superior method for removing of dental plaque among test groups.

A STUDY ON THE RESPONSES OF OSTEOBLASTS TO VARIOUS SURFACE-TREATED TITANIUM

  • Lee Joung-Min;Kim Yung-Soo;Kim Chang-Whe;Jang Kyung-Soo;Lim Young-Jun
    • 대한치과보철학회지
    • /
    • 제42권3호
    • /
    • pp.307-326
    • /
    • 2004
  • Statement of problem. The long-term success of implants is the development of a stable direct connection between bone and implant surface, which must be structural and functional. To improve a direct implant fixation to the bone, various strategies have been developed focusing on the surface of materials. Among them, altering the surface properties can modify cellular responses such as cell adhesion, cell motility and bone deposition. Purpose. This study was to evaluate the cellular behaviors on the surface-modified titanium by morphological observation, cellular proliferation and differentiation. Material and methods. Specimens were divided into five groups, depending on their surface treatment: electropolishing(EP) anoclizing(AN), machining(MA), blasting with hydroxyapatite particle(RBM) and electrical discharge machining(EDM). Physicochemical properties and microstructures of the specimens were examined and the responses of osteoblast-like cells were investigated. The microtopography of specimens was observed by scanning electron microscopy(SEM). Surface roughness was measured by a three-dimensional roughness measuring system. The microstructure was analyzed by X-ray diffractometer(XRD) and scanning auger electron microscopy(AES). To evaluate cellular responses to modified titanium surfaces, osteoblasts isolated from neonatal rat were cultured. The cellular morphology and total protein amounts of osteoblast-like cell were taken as the marker for cellular proliferation, while the expression of alkaline phosphatase was used as the early differentiation marker for osteoblast. In addition, the type I collagen production was determined to be a reliable indicator of bone matrix synthesis. Results. 1. Each prepared specimen showed specific microtopography at SEM examination. The RBM group had a rough and irregular pattern with reticulated appearance. The EDM-treated surface had evident cracks and was heterogeneous consisting of broad sheet or plate with smooth edges and clusters of small grains, deep pores or craters. 2. Surface roughness values were, from the lowest to the highest, electropolished group, anodized group, machined group, RBM group and EDM group. 3. All groups showed amorphous structures. Especially anodized group was found to have increased surface oxide thickness and EDM group had titaniumcarbide(TiC) structure. 4. Cells on electropolished, anodized and machined surfaces developed flattened cell shape and cells on RBM appeared spherical and EDM showed both. After 14 days, the cells cultured from all groups were formed to be confluent and exhibited multilayer proliferation, often overlapped or stratified. 5. Total protein amounts were formed to be quite similar among all the group at 48 hours. At 14 days, the electropolished group and the anodized group induced more total protein amount than the RBM group(P<.05). 6. There was no significant difference among five groups for alkaline phosphatase(ALP) activity at 48 hours. The AN group showed significantly higher ALP activity than any other groups at 14 days(P<.05). 7. All the groups showed similar collagen synthesis except the EDM group. The amount of collagen on the electropolished and anodized surfaces were higher than that on the EDM surface(P<.05).

산-처리 조건이 RBM처리한 티타늄 임플란트의 표면 특성에 주는 영향 (Effects of acid-treatment conditions on the surface properties of the RBM treated titanium implants)

  • 이한아;석수황;이상혁;임범순
    • 대한치과재료학회지
    • /
    • 제45권4호
    • /
    • pp.257-274
    • /
    • 2018
  • 본 논문에서는 순수 티타늄(cp-Ti) 임플란트를 SLA (Sandblasting with Large grit and Acid) 처리할 때 산-처리 용액의 유형, 산-처리 온도 및 산-처리 시간 등이 티타늄 표면에 주는 영향을 평가하고자 하였다. 원판형의 cp-Ti 시편을 준비하여 표면을 인산칼슘계 세라믹 분말로 RBM (Resorbable Blast Media) 처리하였다. 산-처리 용액으로 염산을 30 vol%로 고정하고 황산의 농도를 10, 20, 30, 35 vol%로 증가시키며 혼합한 용액에 증류수를 추가하여 4종의 산-처리 용액을 준비하였다. 실험군은 4종의 산-처리 용액, 3 종의 처리온도 및 3 종의 처리시간 등 36 가지로 분류하여 실험군당 4개의 시편을 산-처리하였다. 산-처리 전 후 시편 무게를 전자저울로 측정하여 무게 감소비율을 계산하였고, 공초점주사전자현미경으로 표면거칠기를 측정하였다. X-선 회절분석기(XRD)로 XRD 패턴을 측정하였고, 주사전자현미경으로 표면 형상을 관찰하였으며, 에너지 분산형 분석기(EDX)와 광전자분광법(XPS)로 표면성분을 분석하였다. 무게 감소비율과 표면거칠기 측정값은 Tukey-multiple comparison test (p = 0.05)로 통계 분석하여 다음의 결과를 얻었다. 산-처리에 따른 티타늄 시편의 무게 감소는 황산의 농도 및 산-처리 용액의 온도가 높을수록 유의하게 증가하였다. 산-처리한 티타늄의 표면 거칠기는 산-처리 조건(황산 농도, 온도, 시간)에 일정한 영향을 받지 않았다. XRD 분석에서 산-처리한 모든 시편에서 티타늄(${\alpha}-Ti$)과 수소화 티타늄($TiH_2$) 결정상이 관찰되었고, XPS 분석으로 티타늄 표면에 얇은 n산화 티타늄 층이 형성된 것을 알 수 있었다. $90^{\circ}C$ 산-용액에서 처리할 경우 티타늄 표면이 과도하게 용해될 수 있으므로 주의하여야 한다.

염산 테트라싸이클린이 RBM적용 임프란트 표면구조에 미치는 영향의 미세구조 및 표면 거칠기 변화에 관한 연구 (The effect of conditioning by Tetracycline-Hcl on implant surface;The SEM study and. surface roughness measurements : RBM surface)

  • 임해수;박준봉;권영혁;허익;정종혁
    • Journal of Periodontal and Implant Science
    • /
    • 제37권3호
    • /
    • pp.585-597
    • /
    • 2007
  • The present study was performed to evaluate the effect of Tetracycline-HCI and Saline on the change of implant surface microstructure and surface roughness according to application time. Implants with resorbable blasting media surface were utilized. Before test all 13 implants were measured surface roughness. Among them, 6 implants were rubbed with 50mg/ml Tetracycline-HCl solution and other 6 implants with saline for $\frac{1}{2}$min., 1min., $1\frac{1}{2}$min., 2min., $2\frac{1}{2}$min and 3min. Then, specimens were processed for scanning electron microscopic observation and surface roughness after test. The results of this study were as follows. 1. Control group showed a few irregular, rough, uneven surface with crater-like depression. 2. The test group with Tetracycline-HCl conditioning showed an altered surface when Tetracycline-HCl was applied for 30secs, and showed a various surface alteration as application times go on. 3. The test group with Saline conditioning showed no significant surface differences and surface roughness. 4. The significant increase of Ra value was showed when Tetracycline-HCl was applied for 30secs. In conclusion, the 50mg/ml Tetracycline-HCl must not be applied for the RBM surface implant for surface treatment.

AN EXPERIMENTAL STUDY OF NEWLY DESIGNED IMPLANT WITH RBM SURFACE IN THE RABBIT TIBIA : RESONANCE FREQUENCY ANALYSIS AND REMOVAL TORQUE STUDY

  • Won Mi-Kyoung;Park Chan-Jin;Chang Kyoung-Soo;Kim Chang-Whe;Kim Yung-Soo;Isa Zakiahbt Mohd;Ariffin Yusnidar Tajul
    • 대한치과보철학회지
    • /
    • 제41권6호
    • /
    • pp.720-731
    • /
    • 2003
  • Statement of problem. The importance of fixture design and surface treatment. Purpose. The clinical success of dental in plants is affected by many factors such like as degree of osseointegration, the effective load dispersion for the prostheses, and a lot of attempts have been made to overcome the difficulties. In this study, efforts were made to find the possibility of clinical acceptance of the dental implants of newly designed surface and resorbable blast media surcace. Materials and methods. In this study, two groups of custom-made, screw-shaped implants were prepared. The first with the consisting of Branemark clone design and the other with the new design. These implants were divided into four groups according to the kinds of surface treatment. Four implants($AVANA^{(R)}$, Osstem, Busan, Korea)of each group were installed in twenty rabbits. Group A was consisted of Branemark done implant left as machined, Group B with Branemark clone implants with RBM(Resorbable blast media) surface, Group C with newly designed implants left as machined and Group D with newly designed implants with RBM surface. One of the twenty rabbits died from inflammation and the observation was made for six weeks. Specimens from four groups were observed using scanning electron microscopy with 40, 100, 1000 magnification power and microsurface structures were measured by white-light scanning interferometry for three dimensional surface roughness measurements(Accura $2000^{(R)}$, Intek-Plus, Korea.). Removal torque was measured in 17 rabbits using digital torque gauge(MGT 12R, Mark-10 corp., NY, U.S.A.) immediately after the sacrifice and two rabbits were used for the histologic preparation(EXAKT $310^{(R)}$, Heraeus Kulzer, wehrheim, Germany) of specimens and observed under light microscope. Resonance frequency measurement($Osstell^{(R)}$) was taken with the 19 rabbits at the beginning of the implant fixation and immediately after the sacrifice. Results. Following results were taken from the experiment. 1. The surface of the RBM implants as seen with SEM had rough and irregular pattern with reticular formation compared to that of fumed specimens showing different surface topographies. 2. The newly designed implant with RBM surface had high removal torque value among four groups with no statistical significance. The average removal torque was $49.95{\pm}6.70Ncm$ in Group A, $51.15{\pm}4.40Ncm$ in Group B, $50.78{\pm}9.37Ncm$ in Group C, $51.09{\pm}4.69Ncm$ in Group D. 3. The RFA values were $70.8{\pm}4.3Hz$ in Group A, $71.8{\pm}3.1Hz$ in Group B, $70.9{\pm}2.5Hz$, $72.7{\pm}2.5Hz$ in Group D. Higher values were noted in the groups which had surface treatment compared to the untreated groups with no statistical significance. 4. The results from the histomorphometric evaluation showed a mean percentage of bone-to-implant contact of $45{\pm}0.5%$ in Group A, $55{\pm}3%$ in Group B, $49.5{\pm}0.5%$ in Group C, and $55{\pm}3%$ in Group D. Quite amount of newly formed bone were observed at the surface RBM-treated implants in bone marrow space.

Er,Cr:YSGG 레이저를 조사한 임플란트 표면의 주사전자현미경적 연구 (SCANNING ELECTRON MICROSCOPIC STUDY OF IMPLANT SURFACE AFTER Er,Cr:YSGG LASER IRRADIATION)

  • 조필귀;민승기;권경환;김영조
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제28권5호
    • /
    • pp.454-469
    • /
    • 2006
  • Today, there is considerable evidence to support a cause-effect relationship between microbial colonization and the pathogenesis of implant failures. The presence of bacteria on implant surfaces may result in an inflammation of the peri-implant mucosa, and, if left untreated, it may lead to a progressive destruction of alveolar bone supporting the implant, which has been named as peri-impantitis. Several maintenance regimens and treatment strategies for failing implants have been suggested. Recently, in addition to these conventional tools, the use of different laser systems has also been proposed for treatment of peri-implant infections. As lasers can perform excellent tissue ablation with high bactericidal and detoxification effects, they are expected to be one of the most promising new technical modalities for treatment of failing implants. It is introduced that Er,Cr:YSGG laser, operating at 2780nm, ablates tissue by a hydrokinetic process that prevents temperature rise. We studied the change of the titanium implant surface under scanning electron microscopy after using Er,Cr:YSGG laser at various energies, irradiation time. In this study, Er,Cr:YSGG laser irradiation of implant fixture showed different effects according to implant surface. Er,Cr:YSGG laser in TPS surface with RBM not alter the implant surface under power setting of 4 Watt(W) and irradiation time of 30sec. But in TPS surface with $Ca_3P$ coating alter above power setting of 2W and irradiation time of 10sec. TPS surface with RBM showed microfracture in 4W, 30sec and TPS surface with $Ca_3P$ coating showed destruction of fine crystalline structure, melting in excess of 2W, 10sec. We concluded that proper power setting, air, water of each implant surface must be investigated and implant surface must be irradiated under the damaged extent.