• 제목/요약/키워드: RAD

Search Result 714, Processing Time 0.025 seconds

Effect of Cortisone on Serum Protein of Gamma-Irradiated Mice ($\gamma$線에 照射된 마우스의 血淸蛋白質에 미치는 Cortisone의 影響)

  • Cho, You Joung;Choi, Kook Hun;Ham, Sang Yul
    • The Korean Journal of Zoology
    • /
    • v.14 no.3
    • /
    • pp.119-124
    • /
    • 1971
  • Male mice of strain SM were given 128 rads of single whole-body gamma-irradiation of $^{60}Co$, 14 to 16 minutes following a subcutaneous injection of physiological saline or cortisone acetate (1mg/day, for 4 days preirradiation). The serum protein patterns and the level of the total serum proteins were determined at various time intervals after exposure. Total serum protein was determined by Biuret method and serum protein fractions and A/G ratio were determined by paper electrophoresis using Whatman No.1 filter paper and barbital buffer (pH 8.6, ionic strength 0.06). 1. Total body gamma-irradiation caused a rise in the level of the total serum protein at 1 day and in the level of the serum albumin-globulin ratio at 5 days in both cortisone acetate-treated and control groups. 2. Cortisone acetate delayed the total serum protein rise at 5, 10, and 20 days after exposure. 3. Cortisone acetate delayed the A/G ratio rise at 1, 5, and 10 days after exposure. 4. It may be inferred that cortisone greatly reduces the sensitivity of mice to gamma-irradiation on the blood protein, probided that cortisone is given before the exposure.

  • PDF

Effects of Angular Acceleration on the Friction and Wear Characteristics of Gas Foil Thrust Bearings (회전각가속도가 가스 포일 스러스트 베어링의 마찰 및 마모 특성에 미치는 영향)

  • Sung Ho Hwang;Dae Yeon Kim;Tae Ho Kim
    • Tribology and Lubricants
    • /
    • v.39 no.5
    • /
    • pp.203-211
    • /
    • 2023
  • This study experimentally investigates the effects of angular acceleration on the friction and wear performances of a gas foil thrust bearing (GFTB) using a typical GFTB with six pads. The outer radius of the bearing is 31.5 mm, the total bearing area is 2,041 mm2 , and the bump foil and incline (ramp) height are both 500 ㎛. The newly developed GFTB test rig for measuring the friction torque and coefficient measures the axial load, drag torque, lift-off speed, and touch-down speed. The experiment is conducted for angular accelerations of 78.5, 314.2, and 328.3 rad/s2 at axial loads of 5, 10, and 15 N, respectively. The test shows that the start-up friction coefficient increases with increasing axial load at the same angular acceleration, and the friction coefficient decreases with increasing angular acceleration under the same axial load. As the angular acceleration increases, the lift-off speed at the motor start-up increases, and the touch-down speed at the motor stop decreases. The wear distance of the GFTB for a single on/off cycle increases with increasing axial load at the same angular acceleration and decreases nonlinearly with increasing angular acceleration under the same axial load. The test results suggest that adjusting the rotational angular acceleration helps reduce bearing friction and wear.

Measurement of the radon and thoron exhalation rates from the water surface of Yixin lake

  • Jiulin Wu;Shuaibin Liu;Tao Hu;Fen Lin;Ruomei Xie;Shuai Yuan;Haibo Yi;Yixiang Mo;Jiale Sun;Linquan Cheng;Huiying Li;Zhipeng Liu;Zhongkai Fan;Yanliang Tan
    • Nuclear Engineering and Technology
    • /
    • v.56 no.4
    • /
    • pp.1538-1543
    • /
    • 2024
  • The importance of determining the radon exhalation rate from water surface is emphasized by the increased use of radon and its daughter products as tracers in large-scale circulation studies of the atmosphere. There were many methods to measure radon exhalation from water surface. With the development of radon exhalation rate measurement methods and instruments on the surface of the soil, the rock and building materials, so the radon exhalation rate from water surface can be more accurately measured by applying these improved methods and instruments. In this paper, a cuboid accumulation chamber surrounded by foam boards and a RAD7 were used to measure the radon exhalation rate on the water surface at three different positions by Yixin lake. Each measurement was performed 2 h. The radon exhalation rate from the water surface was about 6 × 10-3 Bq m-2s-1. The thoron exhalation rate from the water surface also can be estimated, it is about 0.16 Bq m-2s-1. These results hint that the radon transmission from the lake bottom soil to water and then into the atmosphere.

Evaluation of Application of 3D Printing Phantom According to Manufacturing Method (구성 물질에 따른 3D 프린팅 팬텀의 적용 평가)

  • Young Sang Kim;Ju Young Lee;Hoon Hee Park
    • Journal of Radiation Industry
    • /
    • v.17 no.2
    • /
    • pp.173-181
    • /
    • 2023
  • 3D printing is a technology that can transform and process computerized data obtained through modeling or 3D scanning via CAD. In the medical field, studies on customized 3D printing technology for clinical use or patients and diseases continue. The importance of research on filaments and molding methods is increasing, but research on manufacturing methods and available raw materials is not being actively conducted. In this study, we compare the characteristics of each material according to the manufacturing method of the phantom manufactured with 3D printing technology and evaluate its usefulness. We manufactured phantoms of the same size using poly methyl meta acrylate (PMMA), acrylonitrile butadiene styrene (ABS), and Poly Lactic Acid (PLA) based on the international standard phantom of aluminum step wedge. We used SITEC's radiation generator (DigiRAD-FPC R-1000-150) and compared the shielding rate and line attenuation coefficient through the average after shooting 10 times. As a result, in the case of the measured dose transmitted through each phantom, it was confirmed that the appearance of the dose measured for phantoms decreased linearly as the thickness increased under each condition. The sensitivity also decreased as the steps increased for each phantom and confirmed that it was different depending on the thickness and material. Through this study, we confirmed that 3D printing technology can be usefully used for phantom production in the medical field. If further development of printing technology and studies on various materials are conducted, it is believed that they will contribute to the development of the medical research environment.

Comparison of Exposure Dose by Using AEC Mode of Abdomen AP Study in Radiography (복부 전후 방향 검사의 자동노출제어 사용 시 선량 비교 연구)

  • Kim, Ki-Won;Kwon, Yong-Rak;Seo, Seong-Won;Kwon, Kyung-Tae;Oh, Joo-Young;Son, Soon-Yong;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.205-211
    • /
    • 2015
  • We evaluated the effectiveness of TL (Time Limit) method by comparing with NTL (Non-time limit) method when it is used for examinations for abdomen Anterior Posterior (AP) in this paper. The evaluation was conducted based on the comparison of dose, and of signal to noise ratio (SNR) and contrast to ratio (CNR) on both methods. The experiments were conducted with XGEO GC 80 (Samsung, Korea), Unfors ThinX RAD (Unfors, Sweden) and Rando Phantom (Alderson research laboratories, USA) and shielding material with the size of $5.5{\times}9{\times}0.1cm^3$. It was set to activate only two upper ionization chambers in automatic exposure control(AEC) mode and the tube-voltage was set to 80kVp. When the exposure time was limited, it is limited to 51 msec. The images both by NTL AEC method and TL AEC method were acquired when with and without attachment of shielding material on the upper ionization chambers. The images were evaluated by SNR and CNR which are the image evaluation methods using 'Image J'. The NTL AEC method showed increases in dose as much as 130.7% at maximum and 80% at minimum than other methods. The TL AEC method showed decreases in mAs and exposure dose than the NTL AEC method as much as 43.8% and 44.4% respectively. There were no significant differences in SNR or CNR for the experiments (($p{\geq}0.05$). Therefore, it is suggested that the TLAEC mode is more effective when examining patients who have high BMI index or a patient with a metallic substance in the body after surgery.

Postoperative Evaluation of Congenital Atrial Septal Defect in Adult (성인 심방중격결손증의 술후평가)

  • Kim, Ae-Jung;Jo, Jung-Gu;Gu, Ja-Hong;Kim, Gong-Su
    • Journal of Chest Surgery
    • /
    • v.29 no.4
    • /
    • pp.386-392
    • /
    • 1996
  • Preoperative and postoperative evaluation was done in 60 adult patients above 20 years of age among 152 patients, who had operation for the congenital atrial septal defect from January 1984 to June 1993 in the Department of Thoracic and Cardiovascular Surgery, Chonbuk National University Hospital. Anatomically, the secundum type defect was present In 58 cases and the other two were ostium primum type defect. The defect were closed directly in 45 cases and with patches in 15 cases. Preopera ive EKG findings revealed regular sinus rhythm in 81%, arrhythmia 19%, RVH 32%, RAD 30%, Postoperative findings were regular sinus rhythm in 76%, arrhythmia 24%, RVH 25%. RAD 25%. In hemodynamic data, the mean SPAP in patients over 40 years old was 41.91 $\pm$ 14.33mmHg compared to 31.46 $\pm$ 13.77 mmHg in patients under 40 years old, and the difference between the two groups was stastistically significant. And then the patients were classified into two groups (group A sinus group, and group B : arrhythmia group) according to their preoperative rhythm. The patients in group B were older, had greater value of mean SPAP and Rp/Rs. Mean Qp/qs was higher in group A. But the difference between two groups about the mean Qp/qs and Rp/Rs was not significant. Postoperative complications such as arrhythmia, pneumothorax or hemothorax occurred in 7 cases, but there was no operative mortality. The functional improvement were remarkable in half of the patients who underwent surgery.

  • PDF

Power Generating Performance of Photovoltaic Power System for Greenhouse Equipment Operation (온실설비 작동용 태양광발전시스템의 발전 성능 분석)

  • Yoon, Yong-Cheol;Bae, Yong-Han;Ryou, Young-Sun;Lee, Sung-Hyoun;Suh, Won-Myung
    • Journal of Bio-Environment Control
    • /
    • v.18 no.3
    • /
    • pp.177-184
    • /
    • 2009
  • For the purpose of reducing the cost for greenhouse operation by acquiring the electric power necessary for it, this study installed a solar photovoltaic system on the roof of the building adjacent to green-houses and experimentally examined the quantity of power generation based on weather conditions. The results of the study are as per the below: The maximum, average and minimum temperature while the experiment was conducted was $0.4{\sim}34.1,\;-6.1{\sim}22.2$, and $-14.1{\sim}16.7^{\circ}C$ respectively, and the solar radiation was $28.8MJ{\cdot}m^{-2}$ (maximum), $14.9MJ{\cdot}m^{-2}$ (average), and $0.6MJ{\cdot}m^{-2}$ (minimum). The quantity of electric power didn't increase in proportion to the quantity of solar radiation and instead, it was almost consistent around 750W. Daily maximum, average and minimum consumption of electric power was 5.2kWh, 2.5kWh and 0kWh respectively. Based on the average electric power consumption of the system used for this experiment, it was sufficient in case the capacity and the working time of a hot blast heater are small, but it was short in case they are big. In case the capacity of the hot blast heater is big, the average electric power quantity will be sufficient for array area $21m^2$, about three times of the present area. In summer when the temperature of the array becomes high, the generation of electric power didn't increase in proportion to the quantity of solar radiation, but this experiment result shows a high correlation between two factors (coefficient of correlation 0.84).

Effects of Gamma-Irradiation on the Sterilization of Primordial Germ Cells in Quail (메추리 원시생식세포 감소를 위한 감마선 조사의 효과)

  • Park, Kyung-Je;Kim, Tae-Min;Lee, Hyung-Chul;Jang, Hyun-Jun;Song, Gwon-Hwa;Han, Jae-Yong
    • Korean Journal of Poultry Science
    • /
    • v.37 no.2
    • /
    • pp.139-143
    • /
    • 2010
  • Quail is a very useful animal model for studying vertebrate development because of its small body size and unique reproductive traits. This species is also ideal model for producing germline chimeras via transferring exogenous primordial germ cells (PGCs) into the recipient embryo. To increase the contribution efficiency of donor PGCs into recipients' tissues, decreasing the population of endogenous PGCs has been rate-limiting factor. We therefore conducted this study to investigate if gamma ($\gamma$)-irradiation depletes endogenous PGCs in developing quail embryo. Firstly, freshly laid stage X quail embryos were irradiated with various output of $\gamma$-irradiation and its teratogenic effect on the embryo was evaluated. Although a dose-dependent increase in the number of embryo showing malformation was found as the output increased (0, 250, 500, 750, and 1,000 rads), only a maximum of 10.1% of embryos were abnormal in 1,000 rads. Immunocytochemical analysis using the QCR1 antibody, which is specific marker for quail PGCs, was conducted to analyze the effect of sterilization. As results, $\gamma$-rays at a dose-rate of 500 rads/73 sec onto undeveloped stage X embryo significantly reduced the number of germ cells to an average of 75.55 % and 82.03 % in male and female embryos, respectively. We conclude that $\gamma$-ray selectively targets PGCs while affects minimally to the somatic development in quail embryo. Our results will not only provide important data for germline chimera production but can be used for analyzing the effect of ionized rays on the differentiating germ cells in various stages during animal development.

Influence of Environmental Living Standards on Helicobacter pylori Infection in Korean Elementary School Children (서울 지역 초등학생의 생활환경과 Helicobacter pylori 양성률)

  • Kim, Je-Woo;Kim, Hyo-Shin;Chung, Ki-Sup
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.4 no.1
    • /
    • pp.10-17
    • /
    • 2001
  • Purpose: We measured anti-H. pylori IgG in Korean elementary school children living in Shinchon area of Seoul, Korea to evaluate the influence of environmental living standards on H. pylori infection. Methods: IgG antibodies to H. pylori were measured in plasma using a commercial ELISA kit (GAP IgG Helicobacter pylori, Bio-Rad Laboratories Inc., Hercules, CA, USA). Information on environmental status such as place of birth, parental income, type of housing, number of persons in the household, parents' occupation, family history of peptic ulcer disease and gastric cancer was obtained. Statistical analysis was done by Chi-square and logistic regression test using SPSS $7.0^{TM}$ for Windows. Results: Study subjects consisted of 571 children, and the age distribution ranged from 6.0 to 13.6 years with a mean of $9.6{\pm}1.8$ years. Male-to-female ratio was 1.1:1. The seropositive rates of H. pylori infection ranged from 10.4% in children aged 6 years to 30.9% in 12 year-old group, overall 16.8%. The prevalence of H. pylori infection progressively increased with age, but there was no significant difference in seropositive rates among children in different age groups (p=0.06). Seropositive rates of anti-H. pylori IgG on the basis of gender, place of birth, parental income, type of housing, parents' occupation, family history of peptic ulcer disease and gastric cancer showed no statistically significant difference. Interestingly, however, seropositive rate of anti-H. pylori IgG showed statistical significance in relation to number of persons in the household (p=0.003; Odds ratio 1.50 by logistic regression test). Conclusion: These results suggest that number of persons in the household is the most important factor among environmental living standards, and that risk of H. pylori infection increases by increment of 1.5 times as the number of persons in the household increases by one.

  • PDF

The Effect of 131I Therapy by Taking in Laxatives (방사성요오드 치료 시 완하제 투여 효과)

  • Kil, Sang-Hyeong;LEE, Hyo-Yeong;Park, Kwang-Yeol;Jo, Kyung-Nam;Baek, Seung-Jo;Hwang, Kyo-Min;Cho, Seong-Mook;Choi, Jae-Hyeok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.3-9
    • /
    • 2014
  • Purpose: Our goals were to evaluate the effect of high dose radioiodine treatment for thyroid cancer by taking in laxatives. Materials and Methods: Twenty patients(M:F=13:7, age $46.3{\pm}8.1\;yrs$) who underwent high dose radioiodine treatment were seperated into Group 1 taking $^{131}I$ 5,500 MBq and Group 2 with the use of laxatives after taking $^{131}I$ 5,500 MBq. The whole body was scanned 16 hours and 40 hours after taking radioactive iodines by using gamma camera, the ROIs were drawn on the gastro-intestinal tract and thigh for calculation of reduction ratio. At particular time during hospitalization, the radioactivity remaining in the body was measured in 1 meter from patient by using survey meter (RadEye-G10, Thermo Fisher Scientific, USA). Schematic presentation of an Origin 8.5.1 software was used for spatial dose rate. Statistical comparison between groups were done using independent samples t-test. P value less than 0.05 was regarded as statistically significant. Results: The reduction ratio in gastro-intestinal 16 hours and 40 hours after taking laxatives is $42.1{\pm}6.3%$ in Group 1 and $72.1{\pm}6.4%$ in Group 2. The spatial dose rate measured when discharging from hospital was $23.8{\pm}6.7{\mu}Sv/h$ in Group 1 and $8.2{\pm}2.4{\mu}Sv/h$ in Group 2. The radioactivity remaining in the body is much decreased at the patient with laxatives(P<0.05). Conclusion: The use in combination with laxatives is helpful for decreasing radioactivity remaining in the body. The radioactive contamination could be decreased at marginal individuals from patients.

  • PDF