• 제목/요약/키워드: R2-MRI

검색결과 167건 처리시간 0.027초

A Study on Comparison of Cardiac Ejection Fraction Values Measured in Myocardium SPECT and Cine MRI

  • Han, Jung-Seok;Dong, Kyung-Rae;Park, Yong-Soon;Chung, Woon-Kwan;Cho, Jae-Hwan;Cho, Young-Kuk
    • Journal of Magnetics
    • /
    • 제17권3호
    • /
    • pp.229-232
    • /
    • 2012
  • This study examined the correlation between MR cine and myocardium Single-photon emission computed tomography (SPECT) by comparing the measured cardiac ejection fractions. The usefulness of cardiac MRI was also evaluated. Ten patients (8 men, 2 women and average age of 58.6 years), who underwent a myocardium SPECT scan and cardiac cine MRI scan among patients who visited the hospital for the chief complaint of cardiac disorder from June 1, 2010 to February 10, 2011, were enrolled in this study. The cardiac ejection fraction was calculated from the images obtained in both scans. The data was used to examine the correlation. The regression equation the cardiac ejection fraction values of the 10 patients obtained in myocardium SPECT and MRI cine was Y = 1.12X-8.91 ($R^2$ = 0.78, significance of F = 0.001639, and confidence level of 95%). The results were significant when the cardiac ejection fraction obtained from MRI cine was compared with that obtained from myocardium SPECT. Overall, a cardiac examination using MRI enables an investigation of not only the ejection fraction but also the ED and ES volumes, stroke volume, wall thickness, and wall thickening in a higher spatial resolution despite the examination being conducted once. This examination is believed to be very useful for diagnosing patients with cardiac disease.

자기공명영상에서 ACR 팬텀을 이용한 해상력 특성 평가 (Evaluation of the Resolution Characteristics by Using American College of Radiology Phantom for Magnetic Resonance Imaging)

  • 민정환;정회원;한지현;이시내;김민지;김승철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권1호
    • /
    • pp.11-17
    • /
    • 2022
  • This study was purpose to quantitative assessment of the resolution characteristics by using American college of radiology(ACR) phantom for magnetic resonance imaging (MRI). The MRI equipment was used (Achiva 3.0T MRI, Philips system, Netherlands) and the head/neck matrix shim SENSE head coil were 32 channels(elements) receive MR coil. And the MRI equipment was used (Discovery MR 750, 3.0T MRI, GE medical system, America) and the head/neck matrix shim MC 3003G-32R 32-CH head coil were receive MR coil. As for the modulation transfer function(MTF) comparison result by using ACR magnetic resonance imaging phantom, the MTF value of the ACR standard T2 image in GE equipment is 0.199 when the frequency is 1.0 mm-1 and the MTF value of the hospital T2 image in Philips equipment is 0.528. It was used efficiently by using a general sequence more than the standard sequence method using the ACR phantom. In addition it is significant that the quantitative quality assurance evaluation method for resolution characteristics was applied mutatis mutandis, and the result values of the physical image characteristics of the 3.0T MRI device were presented.

DIR 영상을 이용한 피질두께 측정: GRAPPA 인자 2를 이용한 비교 (Cortical Thickness Estimation Using DIR Imaging with GRAPPA Factor 2)

  • 최나래;남윤호;김동현
    • Investigative Magnetic Resonance Imaging
    • /
    • 제14권1호
    • /
    • pp.56-63
    • /
    • 2010
  • 목적 : 본 논문에서는 DIR 영상을 이용하여 두뇌의 피질두께측정 연구를 수행하는 한편 평행 영상기법 중 하나인 GRAPPA (generalized autocalibrating partially parallel acquisitions)를 이용하여 GRAPPA 인자 (reduction factor, R)가 2일 때와 평행 영상기법을 이용하지 않았을 때의 결과 비교를 통해 3D DIR 영상의 획득시간 단축 가능성을 제시하고자 한다. 대상 및 방법 : 3.0T 자기공명영상장치 (Siemens Tim Trio MRI scanner)의 3D DIR 펄스열을 이용하여 6명(남자 3명, 여자 3명, $25.33{\pm}2.25$살)의 정상인 뇌에 대한 3차원 영상을 얻었다. GRAPPA 시뮬레이션은 R=2 일 때를 가정하여 수행되었고 두뇌 피질두께측정을 위해 Analyze 9.0과 Freesurfer v.4.3.0 프로그램을 사용하였다. 결과로 얻은 데이터를 T-검증을 이용하여 비교분석 하였다. 결과 : GRAPPA 기법을 통하여 복원한 영상이 잡음이 증가하는 경향을 보였으나 두뇌 피질두께 측정에는 별다른 영향을 미치지 않았다. 통계분석을 통해 비교한 결과 대부분의 두뇌 영역에서 참조영상과 GRAPPA 기법을 이용한 영상의 차이가 유의하지 않았다. 결론 : 피질두께측정 연구에 있어서 3D DIR영상의 문제점 중 하나는 긴 영상획득시간이다. 따라서 평행영상 기법 중 하나인 GRAPPA 영상기법을 적용하면 피질두께측정 연구결과의 큰 차이없이 영상 획득 시간을 단축시킬 수 있다.

삼차원 자기공명영상법의 뇌 구조 영상을 위한 최적화 연구: 센스인자 변화에 따른 신호변화 평가 (Optimizations of 3D MRI Techniques in Brain by Evaluating SENSE Factors)

  • 박명환;이진완;이강원;류창우;장건호
    • Investigative Magnetic Resonance Imaging
    • /
    • 제13권2호
    • /
    • pp.161-170
    • /
    • 2009
  • 목적 : 평행영상(Parallel imaging)기법의 개발로 긴 촬영시간 때문에 종종 사용되지 못하던 삼차원 영상기법이 최근 들어 환자 병을 진단하는데 새로이 사용되고 있다. 이 연구의 목적은 최근에 뇌 영상에서 개발되어 이용되고 있는 삼차원 자기공명영상을 사람의 뇌에서 짧은 시간 내에 얻을 수 있도록 2차원 평행영상 기법을 사용한 최적화 방법을 연구하는데 있다. 대상 및 방법 : 검사 장비는 3.0T 자기공명영상장치를 이용하였으며 8-채널 SENSE(sensitivity encoding) 머리 코일을 이용하였다. 팬텀 및 3명의 사람 머리에서 영상을 얻었다. 세 가지의 삼차원 영상법인 3D T1WI, 3D T2WI 및 3D FLAIR 영상 방법에 대하여 평행인자(SENSE factor)의 변화에 따른 팬텀 영상을 얻었다. 각각의 영상법에서 영상획득에 적당한 SENSE 인자를 찾기 위해 Phase encoding 방향과 Slice encoding 방향을 조합한 SENSE 인자를 변화시키면서 영상을 얻었다. 영상분석을 위하여 특정영역(ROI)를 설정한 후에 신호대 잡음비 (Signal-to-noise ratio, SNR), 감소분율(Percent Signal Reduction Rate, %R), 대조도(contrast-to-noise ratio, CNR)를 계산하였다. 결과 : 팬텀을 이용한 SENSE 인자 변화에 따른 SNR 및 %R 값의 변화 결과 3D T1WI 방법에서 SENSE 인자를 사용한 것들 중에서 SENSE 인자를 총 3인 경우 약 0.2%의 신호 감소가 나타났고 영상시간은 5분 이내였다. 3D T2WI 방법의 경우 SENSE 인자를 사용한 것들 중에서 SENSE 인자를 총 3인 경우에 약 1.0% 신호 감소가 나타났고 영상 시간은 약 5분 이내였다. 3D FLAIR 방법의 경우 SENSE 인자를 사용한 것들 중에서 SENSE 인자를 4를 사용한 경우에 약 0.2% 신호 감소가 나타났고 영상시간은 약 6분이었다. 사람을 대상으로 할 경우 3D T1W 및 3D T2W영상에서 SNR 및 CNR은 SENSE 인자를 3으로 한 경우에서 SENSE 인자를 4로 한 경우 보다 높게 나타났다. 3D FALIR 영상의 경우 CNR은 SENSE 4에서는 SENSE 3에 비하여 낮았다. 결론 : 본 연구에서는 3가지 3차원 영상법을 실제 임상적용이 가능한 시간 영역에서 SENSE 인자를 변화 시키면서 치적의 영상을 얻도록 하는 연구를 실시한 결과 SNR 감소를 최소화 하면서 영상획득 시간을 약 5분에서 6분 정도 소요되는 2차원 SENSE 인자를 찾았다. 이를 뇌 영상에 적용하였을 경우 SENSE 인자를 적용하지 않은 경우와 비교하면 신호 감소는 최소화 하면서 영상의 질은 큰 영향을 주지 않은 것으로 나타났다. 3D T1W및 3D T2W는 SENSE 인자를 3으로 3D FLAIR인자는 SENSE 인자를 4로 하는 것이 환자를 대상으로 한 뇌 영상에 적합하다고 생각된다. 앞으로는 이들 영상법이 뇌 영상뿐만 아니라 다른 영역의 영상에 적용을 위한 최적화가 필요하다고 생각된다.

  • PDF

뇌교종의 악성도 평가에서의 관류자기공명영상의 유용성에 관한 연구 (A Study on the Usefulness of Perfusion MRI in Grading of Gliomas)

  • 강현수;김종만;고신관;문찬홍;유인규;한동균
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제32권4호
    • /
    • pp.461-469
    • /
    • 2009
  • 최근 신경계 질환의 진단에 많이 이용되는 관류자기공명영상기법 중 상대적 뇌 혈류량(relative cerebral blood volume)의 분석에 의한 뇌교종의 악성도 구분(고등급과 저등급 종양의 구분)에 있어 자기공명영상의 뇌 혈류량 검사의 유용성에 대하여 알아보고자 하였다. 뇌교종 환자 17명(평균연령 57.5세, 남자 11명, 여자 6명)을 대상으로 모든 환자에게 수술 전 관류자기공명 영상과 고식적 뇌 자기공명영상을 시행하고, 조직의 병리학적 검사를 시행하였다. 국소적 뇌 혈류량과 상대적 뇌 혈류량의 분석은 지멘스사의 소프트웨어(PAT)와 자체 개발한 영상 후 처리 소프트웨어 Xmap 2.0을 이용하여 비교, 분석하였다. 대상자 17명 중 뇌교종이 저등급인 6명과 고등급인 11명의 관류자기공명영상의 분석 결과는 저등급 뇌교종의 상대적 뇌 혈류량의 백질에 대한 종양부위의 평균 뇌 혈류량(rCBVw)의 평균은 1.62, 피질에 대한 종양부위의 평균 뇌 혈류량(rCBVc)의 평균은 0.12이었다. 고등급 뇌교종의 상대적 뇌 혈류량의 rCBVw의 평균은 33.53, rCBVc의 평균은 0.96이었다. 뇌교종과 반대측 뇌 백질과의 통계적인 상관성은 0.01(p-value)이었고. 뇌교종과 반대측 피질과의 통계적인 상관성은 0.02(p-value)로 나타났다. 결과 중 뇌교종과 뇌 백질의 통계분석수치가 뇌교종과 피질과의 통계분석 결과보다 더 유의한 결과를 나타내었다. 결국 두 가지 모두에서 유의한 결과를 나타냄을 알 수 있었다(p<0.05). 임상적으로 기존의 자기공명영상과 병리학적 결과와 함께 관류자기공명영상은 뇌교종의 등급을 판단하는데 있어 유용할 것으로 사료된다.

  • PDF

The Effect of Scalp Acupuncture and rTMS on Neuromotor Function in Photothrombotic Stroke Rat Model

  • Jong-Seong Park;Eun-Jong Kim;Min-Keun Song;Jung-Kook Kim;Ganbold Selenge;Sam-Gyu Lee
    • 대한의생명과학회지
    • /
    • 제29권4호
    • /
    • pp.263-273
    • /
    • 2023
  • This study aimed to investigate effect of scalp acupuncture (SA) and repetitive transcranial magnetic stimulation (rTMS) intervention on neuromotor function in photothrombotic cerebral infarction (PCI) rat model. Sixty male SD rats were used. PCI was induced on M1 cortex of right frontal lobe. SA was performed at the Qianding (GV21), Xuanli (GB6) acupoints of ipsilesional M1. Low-frequency rTMS was delivered to contralesional M1. All rats were randomly divided into 4 groups: group A, normal (n, 15); group B, PCI without any stimulation intervention (n, 15); group C, PCI with SA (n, 15); group D, PCI with rTMS (n, 15). Rota-rod test and Ladder rung walking test (LWT) were done weekly for 8 weeks after PCI. SA or rTMS was started from post-PCI 4th day as protocol for 8 weeks. H/E stain and IHC were done. Western blot and qRT-PCR study were performed for MAP2 and BDNF from ipsilesional M1 peri-infarction tissue. Brain MRI study was conducted to quantify the volume of cerebral infarction. As a result, left forelimb and hindlimb function significantly improved more in group C and D than control group, with expressed more BDNF and MAP2. And brain MRI showed focal infarction of right M1 after PCI, and infarction volume progressively decreased in group C and D than group B from post-PCI 5th to 8th week. SA or rTMS was more effective than no intervention group on neuromotor function of PCI rat model. The functional recovery was associated with stimulation intervention-related neurogenesis.

고온초전도 선재와 정합회로를 이용한 RF coil 제작에 대한 기초연구 (Study on fabricated RF coil using high-temperature superconductor tape and matching circuit for low field MRI system)

  • 김동혁;고락길;강부민;하동우;손명환;문치웅
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제14권1호
    • /
    • pp.44-47
    • /
    • 2012
  • The substantial improvement of the signal-to-noise ratio (SNR) can be achieved with small-size samples or low-field MRI system by high-temperature superconducting(HTS) RF coil. The typical HTS RF coil made of HTS thin film is expensive and is limited the coil geometry to planar surface coil. In this study, commercial Bi-2223 HTS tapes was used as RF coil for a 0.35T permanent MRI system. It has advantages of both much lower cost and easier fabrication over HTS thin film coil. SNR gain of the image obtained from the HTS RF coil over a conventional Cu RF coil at room temperature was about 2.4-fold and 1.9-fold using the spin echo pulse sequence and gradient echo pulse sequence respectively.

Clinical impact of spine magnetic resonance imaging as a valuable prognostic tool for patients with multiple myeloma: a retrospective study

  • Lee, Jung Min;Cho, Hee Jeong;Moon, Joon-Ho;Sohn, Sang Kyun;Park, Byunggeon;Baek, Dong Won
    • Journal of Yeungnam Medical Science
    • /
    • 제39권4호
    • /
    • pp.300-308
    • /
    • 2022
  • Background: This study investigated the prognostic impact of spine magnetic resonance imaging (MRI) in patients newly diagnosed with multiple myeloma (MM). Methods: We retrospectively evaluated 214 patients who were newly diagnosed with MM between March 2015 and December 2019. The patients were classified into five different infiltration patterns based on spine MRI as follows: (1) normal appearance, (2) focal, (3) diffuse, (4) combined focal and diffuse infiltration, and (5) "salt-and-pepper." Results: Forty patients (18.7%) showed a normal appearance, whereas focal, diffuse, combined focal and diffuse infiltration, and "salt-and-pepper" patterns were identified in 68 (31.8%), 40 (18.7%), 52 (24.3%), and 14 patients (6.5%), respectively. The patients with normal and "salt-and-pepper" patterns were younger than patients with other patterns (median age, 61.6 vs. 66.8 years; p=0.001). Moreover, 63% and 59.3% of patients with normal and "salt-and-pepper" patterns were scored International Staging System (ISS) stage I and revised ISS (R-ISS) stage I, respectively, whereas only 12.5% of patients with other patterns were scored ISS stage I and R-ISS stage I. Patients with normal and "salt-and-pepper" patterns had a better prognosis than those with other patterns, whereas relapse and death rates were significantly higher in patients with focal, diffuse, and combined MRI patterns. Conclusion: Characteristic MRI findings have a significant prognostic value for long-term survival in patients newly diagnosed with MM. In particular, focal, diffuse, and combined focal and diffuse infiltration patterns are unfavorable prognostic factors.

Reliability of Stereotactic Coordinates of 1.5-Tesla and 3-Tesla MRI in Radiosurgery and Functional Neurosurgery

  • Kim, Hae Yu;Lee, Sun-Il;Jin, Seong Jin;Jin, Sung-Chul;Kim, Jung Soo;Jeon, Kyoung Dong
    • Journal of Korean Neurosurgical Society
    • /
    • 제55권3호
    • /
    • pp.136-141
    • /
    • 2014
  • Objective : The aims of this study are to identify interpersonal differences in defining coordinates and to figure out the degree of distortion of the MRI and compare the accuracy between CT, 1.5-tesla (T) and 3.0T MRI. Methods : We compared coordinates in the CT images defined by 2 neurosurgeons. We also calculated the errors of 1.5T MRI and those of 3.0T. We compared the errors of the 1.5T with those of the 3.0T. In addition, we compared the errors in each sequence and in each axis. Results : The mean difference in the CT images between the two neurosurgeons was $0.48{\pm}0.22mm$. The mean errors of the 1.5T were $1.55{\pm}0.48mm$ (T1), $0.75{\pm}0.38$ (T2), and $1.07{\pm}0.57$ (FLAIR) and those of the 3.0T were $2.35{\pm}0.53$ (T1), $2.18{\pm}0.76$ (T2), and $2.16{\pm}0.77$ (FLAIR). The smallest mean errors out of all the axes were in the x axis : 0.28-0.34 (1.5T) and 0.31-0.52 (3.0T). The smallest errors out of all the MRI sequences were in the T2 : 0.29-0.58 (1.5T) and 0.31-1.85 (3.0T). Conclusion : There was no interpersonal difference in running the Gamma $Plan^{(R)}$ to define coordinates. The errors of the 3.0T were greater than those of the 1.5T, and these errors were not of an acceptable level. The x coordinate error was the smallest and the z coordinate error was the greatest regardless of the MRI sequence. The T2 sequence was the most accurate sequence.

MRI와 동시에 측정한 뇌전도 신호로 전류원 국지화를 할 때 경사자계 유발 잡음의 영향 분석 (Effects of Gradient Switching Noise on ECD Source Localization with the EEG Data Simultaneously Recorded with MRI)

  • 이항로;한재용;조민형;임창환;정현교;이수열
    • Investigative Magnetic Resonance Imaging
    • /
    • 제7권2호
    • /
    • pp.108-115
    • /
    • 2003
  • 목적 : MRI를 촬영하면서 동시에 측정한 뇌전도 신호에 가장 크게 영향을 미치는 것은 경사자계 유발 잡음이다. MRI와 동시에 측정한 뇌전도 신호에서 전류원 국지화를 수행할 때, 경사자계 유발 잡음이 미치는 영향을 분석하고자 한다. 대상 및 방법 : 사람의 머리와 유사하게 만든 뇌전도 팬텀과 MR compatible 뇌전도 측정시스템, 그리고 3.0 Tesla MRI 시스템을 실험에 사용하였다. 3.0 Tesla MRI 시스템 안에 전류원이 설치되어 있는 뇌전도 팬텀을 놓고, EPI 촬영을 하는 동안 뇌전도 신호를 측정하였다. 경사자계의 세기와 전류원의 위치를 조절하면서 뇌전도 신호 측정을 하였고, 측정된 뇌전도 신호에 대하여 전류원 국지화를 수행할 때 나타나는 국지화 오차를 평가하였다. 결과 : 경사자계 유발잡음에 의한 국지화 오차는 경사자계의 세기와 전류원의 위치에 따라 변화하는 것을 관찰하였다. 또한 경사자계 유발잡음이 Gaussian 잡음보다 전류원 국지화에 미치는 영향이 큰 것을 관찰하였으며, 경사자계 유발 잡음의 전력이 뇌전도 신호 전력의 $10\%$ 이하일 때는 전류원 국지화에 미치는 영향이 미미함을 관찰하였다. 결론 : 경사자계 유발 잡음 전력을 뇌전도 신호 전력의 $10\%$ 이하로 줄인다면 MRI를 하면서 동시에 측정한 뇌전도 신호로도 전류원 국지화를 할 수 있음을 알 수 있었다.

  • PDF