• Title/Summary/Keyword: R-D diagram

Search Result 126, Processing Time 0.028 seconds

Removal of Cu and Fe Impurities on Silicon Wafers from Cleaning Solutions (세정액에 따른 실리콘 웨이퍼의 Cu 및 Fe 불순물 제거)

  • Kim, In-Jung;Bae, So-Ik
    • Korean Journal of Materials Research
    • /
    • v.16 no.2
    • /
    • pp.80-84
    • /
    • 2006
  • The removal efficiency of Cu and Fe contaminants on the silicon wafer surface was examined to investigate the effect of cleaning solutions on the behavior of metallic impurities. Silicon wafers were intentionally contaminated with Cu and Fe solutions by spin coating and cleaned in different types of cleaning solutions based on $NH_4OH/H_2O_2/H_2O\;(SC1),\;H_2O_2/HCl/H_2O$ (SC2), and/or HCl/$H_2O$ (m-SC2) mixtures. The concentration of metallic contaminants on the silicon wafer surface before and after cleaning was analyzed by vapor phase decomposition/inductively coupled plasma-mass spectrometry (VPD/ICP-MS). Cu ions were effectively removed both in alkali (SC1) and in acid (SC2) based solutions. When $H_2O_2$ was not added to SC2 solution like m-SC2, the removal efficiency of Cu impurities was decreased drastically. The efficiency of Cu ions in SC1 was not changed by increasing cleaning temperature. Fe ions were soluble only in acid solution like SC2 or m-SC2 solution. The removal efficiencies of Fe ions in acid solutions were enhanced by increasing cleaning temperature. It is found that the behavior of metallic contaminants as Cu and Fe from silicon surfaces in cleaning solutions could be explained in terms of Pourbaix diagram.

Thermodynamic analysis on the chemical vapor deposition process of Ta-C-H-Cl system

  • Kim, Hyun-Mi;Shim, Kwang Bo;Lee, Jung-Min;Lee, Hyung-Ik;Choi, Kyoon
    • Journal of Ceramic Processing Research
    • /
    • v.19 no.6
    • /
    • pp.519-524
    • /
    • 2018
  • Carbon/carbon composites (C/C) have been widely studied in the aerospace field because of their excellent thermal shock resistance and specific strength at high temperature. However, they have the problems that is easily oxidized and deteriorated under atmospheric environment. In order to overcome these shortcomings, the CVD coating of ultra-high-temperature ceramics to C/C has become an important technical issue. In this study, thermodynamic calculations were performed to TaC CVD coating on C/C by FactSage 6.2 program. The Ta-C phase diagrams were constructed with the results of thermodynamic calculations in the Ta-C-H-Cl system. Based on the Ta-C phase diagram, the experimental conditions were designed to confirm the deposition of various phases such as TaC single phase, TaC + C and $TaC+Ta_2C$ by varying the composition of Ta/C ratio. The deposited films were found to be in good agreement with the predicted phases.

Numerical Studies on Combined VH Loading and Inclination Factor of Circular Footings on Sand (모래지반에서 원형기초의 수직-수평 조합하중 지지력과 경사계수에 대한 수치해석 연구)

  • Kim, Dong-Joon;Youn, Jun-Ung;Jee, Sung-Hyun;Choi, Jaehyung;Lee, Jin-Sun;Choo, Yun Wook
    • Journal of the Korean Geotechnical Society
    • /
    • v.30 no.3
    • /
    • pp.29-46
    • /
    • 2014
  • For circular rigid footings with a rough base on sand, combined vertical - horizontal loading capacity was studied by three-dimensional numerical modelling. A numerical model was implemented to simulate the swipe loading and the probe loading methods and an interpretation procedure was devised in order to eliminate the numerical error from the restricted mesh density. Using the Mohr-Coulomb plasticity model, the effect of friction angle was studied under the associated flow-rule condition. The swipe loading method, which is efficient in that the interaction diagram can be drawn with smaller number of analyses, was confirmed to give similar results with the probe loading method, which follows closely the load-paths applied to real structures. For circular footings with a rough base, the interaction diagram for combined vertical (V) - horizontal (H) loading and the inclination factor were barely affected by the friction angle. It was found that the inclination factors for strip and rectangular footings are applicable to circular footings. For high H/V ratios, the results by numerical modelling of this study were smaller than the results of previous studies. Discussions are made on the factors affecting the numerical results and the areas for further researches.

Development of R&D Performance Management System in Disaster and Safety based on the PMS (프로젝트 관리체계 기반 재난안전 R&D 성과관리 체계 구축)

  • Jang, Kwang-Jin;Song, Young-Karb
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.7
    • /
    • pp.153-163
    • /
    • 2018
  • There is insufficient effective management systems to achieve project goalsin disaster and safety R&D. Therefore, to develop an R&D performance management system, this paper develops a R&D performance management matrix based on PMBOK to systematize a process and to enhance efficiency of performance management. Also, this paper identified vulnerable procedures in disaster management by analyzing related laws, work process and performance. Analysis results found that the performance management matrix in disaster management R&D consists of 5 process groups, 7 knowledge areas and 47 processes. Also, the performance of the diffusion knowledge process was evaluated as weak in the present management system. This study defined ITO and developed a data flow diagram for applicationto related work. The suggestions of this study include the related work to enhance R&D performance, contribute to improving diffusion of R&D performance, and enhance the utilization of developed technologies.

Analyses of Leakage Magnetic Field and Leakage Inductance in Current Transformers by 3-D Integral Methods (3차원 적분법을 이용한 변류기의 누설 자계 및 누설 인덕턴스 해석)

  • 이희갑;박용필;이준웅;박우현;이기식
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.503-506
    • /
    • 2001
  • This paper presents leakage magnetic field and leakage inductance calculations in current transformer by means of 3-D Integral methods. From the distribution diagram of leakage magnetic flux to be analyzed using program called TRACAL3, it confirms a parallel to the winding axis direction of the leakage flux lines in the air gap between the windings. The leakage inductances L$\sub$r1/ and L$\sub$R2/ of the primary and secondary windings were calculated, their values are 4.23 mH and 0.49 mH, respectively. They are also similar to the measured values of the leakage inductances for the experimental verification, 4.06 mH and 0.47 mH.

  • PDF

A Study on the Magnetic Field Analysis and Leakage Inductance in Current Transformers by 3D Integral Methods (3차원 적분법을 이용한 변류기의 자계해석과 누설 인덕턴스에 대한 연구)

  • 이희갑;박용필
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.9
    • /
    • pp.768-772
    • /
    • 2001
  • This paper presents leakage magnetic field and leakage inductance calculations in current transformer by means of 3-D Integral methods. From the distribution diagram of leakage magnetic flux to be analyzed using program called TRACAL 3, ti confirms a parallel to the winding axis direction of the leakage flux lines in the air gap between the windings. The leakage inductances L$\sub$r1/ and L$\sub$r2/ of the primary and secondary winding were calculated, their values are 4.23 MH and 0.49 mH, respectively. They are also similar to the measured values of he leakage inductances of the experimental verification, 4.06 mH and 0.47 mH.

  • PDF

A study on the fatigue characteristics of SLS 3D printed PA2200 according to uniaxial cyclic tensile loading (SLS 3D 프린터를 이용하여 제작된 PA2200의 단축 반복 인장하중에 따른 피로 특성에 관한 연구)

  • Park, Jun-Soo;Jeong, Eui-Chul;Choi, Han-Sol;Kim, Mi-Ae;Yun, Eon-Gyeong;Kim, Yong-Dae;Won, Si-Tae;Lee, Sung-Hee
    • Design & Manufacturing
    • /
    • v.14 no.1
    • /
    • pp.49-55
    • /
    • 2020
  • In this study, the fatigue behavior and fatigue life characteristics of PA2200 specimens fabricated by SLS 3D printer were studied. Fatigue tests were performed according to the standard specification (ASTM E468) and fatigue life curves were obtained. In order to perform the fatigue test, mechanical properties were measured according to the test speed of the simple tensile test, and the self-heating temperature of the specimen according to the test speed was measured using an infrared temperature measuring camera in consideration of heat generation due to plastic deformation. There was no significant difference within the set test speed range and the average self-heating temperature was measured at 38.5 ℃. The mechanical strength at the measured temperature showed a relatively small difference from the mechanical strength at room temperature. Fatigue test conditions were established through the preceding experiments, and the loading conditions below the tensile strength at room temperature 23 ℃ were set as the cyclic load. The maximum number of replicates was less than 100,000 cycles, and the fracture behavior of the specimens with the repeated loads showed the characteristics of Racheting. It was confirmed that SLS 3D printing PA2200 material could be applied to the Basquin's S-N diagram for the fatigue life curve of metal materials. SEM images of the fracture surface was obtained to analyze the relationship between the characteristics of the fracture surface and the number of repetitions until failure. Brittle fracture, crazing fracture, grain melting, and porous fracture surface were observed. It was shown that the larger the area of crazing damage, the longer the number of repetitions until fracture.

Optimum Stand Density Control Considering Stability in Larix kaempferi Forests (임분 안정성을 고려한 일본잎갈나무 임분밀도 관리의 적정 수준)

  • Park, Joon Hyung;Chung, Sang Hoon;Kim, Sun Hee;Lee, Sang Tae
    • Journal of Korean Society of Forest Science
    • /
    • v.109 no.2
    • /
    • pp.202-210
    • /
    • 2020
  • This study investigated the optimal levels of stand density control considering the stability of Larix kaempferi stands. A stand density management diagram was developed from 259 sample plots. Based on these data, we determined an optimal level of the stand density control by identifying the relationship between the relative yield index (Ry) and height-to-diameter ratio. The estimated r-square (R2) of the stand density management diagram is 0.600. The analysis of the relationship between Ry and the slender tree incidence showed that when the stand density exceeded a certain threshold and the ratio of slender trees rapidly increased. The critical value of Ry was 0.63. The results of this study are expected to contribute to the establishment of stand management strategies that can reduce damage from natural causes, such as wind and snow, and to develop stand practice systems for the improved productivity of commercial forests.

IMPLEMENTATION OF STRUCTURAL DIAGRAM FOR INTELLECTUAL PROPERTY MANAGEMENT AND PROTECTION(IPMP)

  • Park, Jung-Hee;Lee, Ki-Dong;Lee, Sang-Jae
    • 한국디지털정책학회:학술대회논문집
    • /
    • 2004.11a
    • /
    • pp.435-448
    • /
    • 2004
  • While Internet promises ubiquitous access, it also creates a fundamental challenge to the traditional ownership toward digital assets traded in e-commerce market. Sharing digital information freely through shared networks leads to many untapped business opportunities, but uncontrolled digital asset transaction undermines many electronic business models. Thus, in this Internet age, proper protection and safe delivery of Intellectual Property (IP) and its representation as digital assets would be a crucial ingredient of building trust in upcoming e-business environment. In this paper, we give a general structural diagram of Intellectual Property Management and Protection (IPMP) and implement an IPMP prototype based on the RSA encryption algorithm and XrML (eXtensible rights Markup Language) WORK tags to show how proper protection and safe delivery of the intellectual property is achieved. This study concludes that IPMP mechanism may contribute significantly to the volume and quality of e-commerce market.

  • PDF

The Behavior of Shrinkage on PMMA in Injection Molding Compression Molding (사출압축성형시 PMMA 재료의 성형수축거동)

  • Choi, Y.S.;Han, S.R.;Jeong, Y.D.
    • Journal of Power System Engineering
    • /
    • v.9 no.4
    • /
    • pp.83-89
    • /
    • 2005
  • Molding shrinkage is one of the problems to be solved in conventional injection molding. Despite many trying-out has been to solve it, intrinsic cause of shrinkage such as orientation and thermal exchange between melt and mold has not been solved yet. For reducing shrinkage and residual stress on molding, injection compression molding process was invented. In this study, experiments about effects of injection compression molding's parameters on shrinkage of PMMA molding were conducted and compared with conventional injection molding's shrinkage. Before the injection compression molding experiment, molding shrinkage rate was predicted by analyzing pvT diagram and was compared with the results of experiment. The shrinkage rate of injection compression molding was lower than convention injection molding's one which was different from the predicted shrinkage. The reason was observed that the experimental mold was not a proper type for injection compression, flowing backward of melt into nozzle and unreasonable mechanism of injection molding machine.

  • PDF