• Title/Summary/Keyword: R-C circuit

Search Result 288, Processing Time 0.03 seconds

RF Characteristics of TO-can Packaged FP-LD Optical Transceiver Module (TO-can 패키지 레이저 다이오드 모듈의 주파수 특성 개선)

  • 이동수
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.4
    • /
    • pp.8-12
    • /
    • 2003
  • Characteristics of optical transceiver module in radio frequency(RF) band were investigated with TO-can packaged Fabry-Perot laser diode(FP-LD). R-L-C parameters for equivalent circuit model of the LD were extracted with an impedance analyzer. With this model, impedance matching to the packaged LD could be performed by eliminating inductive components of the leads in the package by using lumped chip capacitors that have opposite reactance, while it shows resonance dip in low frequency band. The resonance dip could be removed using lumped elements for impedance matching by shifting the resonance frequency to the region out of interest.

Implementation of transmitter signal processing of the MP/HF DSC Controller (MF/HF DSC controller의 송신신호처리 구현)

  • 이홍기;유형열;조형래
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.1 no.1
    • /
    • pp.123-129
    • /
    • 1997
  • This study is implementation of transmitter signal processing of MF/HF DSC Controller, obliligation system of GMDSS, focused on the technique of processing to encode the distress and general signal of the DSC message. We analyzed recommendation which prescribed frequencies, operational procedures and technical sequence of the DSC and suggested the basic circuit to be materialize the function of a distress alert and general calf of the DSC equipment using Microprocessor, constructed the algorithm of processing a message, programmed it using C language.

  • PDF

A Study on Thermal Heating Control Performance of Automatic Thermostatic Valves in Floor Radiant Heating System (바닥난방 시스템의 열환경 개선을 위한 제어방안 연구)

  • Song, Jae-Yeob;Ahn, Byung-Cheon;Kim, Kyung-Chul;Jang, Sa-Yun
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.973-978
    • /
    • 2009
  • In this study, the thermal environment characteristics of On-Off control and thermal difference proportional control method in floor radiant heating system were researched by computer simulation. For the analysis of unsteady heat transfer phenomena in household, the method of using electrical equivalent R-C circuit is applied, and radiation heat transfer between panel, ceiling and walls in household is calculated by enclosure analysis method. The parametric study on two control methods, conventional on-off control and temperature error based time control(T.E.B.T.C.) method, are performed to compare thermal heating control performances, respectively.

  • PDF

A study on modified algorithm to operating train simulation of AT feeding systems (전기철도 AT급전계통의 열차 운형 모의 해석 알고리즘 연구)

  • Choo, Dong-Woog;Kim, Jae-Chul;Jung, Yong-Chul;Jun, Yong-Ju;Lim, Seong-Jeong
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.449-451
    • /
    • 2001
  • This study presents a study on modified algorithm to operating train simulation of AT feeding systems. In this study equivalent impedance is constructed by $Z_c,\;Z_r,\;Z_f,\;Z_{cr},\;Z_{rf},\;Z_{fc}$. The train current flows through the all auto-transformer corresponding to track impedance. To calculate train voltage from analyzing the railway systems, the algorithm is based on the K. C. L, K. V. L, superposition and circuit separation method. Multi-train's voltages are determined by calculating the catenary voltage at each train's position and adding up these train's voltage drop. Case studies use a field operational data, show that the proposed method is easily applied.

  • PDF

SINTERED $Al_{2}O_{3}$-TiC SUBSTRATE FOR THIN FILM MAGNETIC HEAD

  • Nakano, Osamu;Hirayama, Takasi
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 1998.04b
    • /
    • pp.6-6
    • /
    • 1998
  • In 1957, the first magnetic disk drive compatible with a movable head was introduced as an external file memory device for computer system. Since then, magnetic disks have been improved by increasing the recording density, which has brought about the development of a high performance thin film magnetic head. The thin film magnetic head has a magnetic circuit on a ceramic substrate using IC technology. The physical property of the substrate material is very important because it influences the tribology of head/disk interface and also manufacturing process of the head. $Al_{2}O_{3}$-TiC ceramics, so called ALTIC, is known to be one of the best substrate materials which satisfies this property requirement. Even though the head is not in direct contact with the disk, frequent instantaneous contacts are unavoidable due to its high rotating speed and the close gap between them. This may cause damage in the magnetic recording media and, thus, it is very important that the magnetic head has a good wear resistance. $Al_{2}O_{3}$-TiC ceramics has an excellent tribological property in head/disk interface. Manufacturing process of thin film head is similar to that of IC, which requires extremely smooth and flat surface of the substrate. The substrate must be readily sliced into the heads without chipping. $Al_{2}O_{3}$-TiC ceramics has excellent machineability and mechanical properties. $Al_{2}O_{3}$-TiC ceramics was first developed at Nippon Tungsten Co. as cutting tool materials in 1968, which was further developed to be used as the substrate materials for thin film head in collaboration with Sumitomo Special Metals Co., Ltd. in 1981. Today, we supply more than 60% of the substrates for thin film head market in the world. In this paper, we would like to present the sintering process of $Al_{2}O_{3}$-TiC ceramics and its property in detail.

  • PDF

0.6 mAh All-Solid-State Thin Fim Battery Fabricated on Alumina Substrate (알루미나 기판상에 구현된 0.6mAh급 전고상 박막전지)

  • Park, H.Y.;Nam, S.C.;Lim, Y.C.;Choi, K.G.;Lee, K.C.;Park, G.B.;Cho, S.B.
    • Journal of the Korean Electrochemical Society
    • /
    • v.8 no.4
    • /
    • pp.181-185
    • /
    • 2005
  • Lithium cobalt oxide thin film cathode, having thickness of $2.9{\mu}m$ with area of $4cm^2$, was deposited on platinum patterned alumina substrate by radio frequency magnetron sputtering. Li/Co molar ratio, which is an important factor for battery performance, was measured as a function of argon working pressure and applied R.F. power. Constant current charge and discharge performances were characterized with high rate discharge and cycling behavior. Using AC impedance analysis, internal resistance of the thin film battery was measured and simulated by proposed equivalent circuit model.

Comparisons of Interfacial Reaction Characteristics on Flip Chip Package with Cu Column BOL Enhanced Process (fcCuBE®) and Bond on Capture Pad (BOC) under Electrical Current Stressing

  • Kim, Jae Myeong;Ahn, Billy;Ouyang, Eric;Park, Susan;Lee, Yong Taek;Kim, Gwang
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.20 no.4
    • /
    • pp.53-58
    • /
    • 2013
  • An innovative packaging solution, Flip Chip with Copper (Cu) Column bond on lead (BOL) Enhanced Process (fcCuBE$^{(R)}$) delivers a cost effective, high performance packaging solution over typical bond on capture pad (BOC) technology. These advantages include improved routing efficiency on the substrate top layer thus allowing conversion functionality; furthermore, package cost is lowered by means of reduced substrate layer count and removal of solder on pad (SOP). On the other hand, as electronic packaging technology develops to meet the miniaturization trend from consumer demand, reliability testing will become an important issue in advanced technology area. In particular, electromigration (EM) of flip chip bumps is an increasing reliability concern in the manufacturing of integrated circuit (IC) components and electronic systems. This paper presents the results on EM characteristics on BOL and BOC structures under electrical current stressing in order to investigate the comparison between two different typed structures. EM data was collected for over 7000 hours under accelerated conditions (temperatures: $125^{\circ}C$, $135^{\circ}C$, and $150^{\circ}C$ and stress current: 300 mA, 400 mA, and 500 mA). All samples have been tested without any failures, however, we attempted to find morphologies induced by EM effects through cross-sectional analysis and investigated the interfacial reaction characteristics between BOL and BOC structures under current stressing. EM damage was observed at the solder joint of BOC structure but the BOL structure did not show any damage from the effects of EM. The EM data indicates that the fcCuBE$^{(R)}$ BOL Cu column bump provides a significantly better EM reliability.

An Experimental Study on the Evaporative Heat Transfer Characteristics of R-134a in a Micro-Channel Heat Exchanger (마이크로채널 열교환기에서 R-134a의 증발열전달 특성에 관한 실험적 연구)

  • Lee, Hae-Seung;Jeon, Dong-Soon;Kim, Young-Lyoul;Kim, Yong-Chan;Kim, Seon-Chang
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.2
    • /
    • pp.113-120
    • /
    • 2010
  • An experimental investigation was carried out to examine the evaporative heat transfer characteristics of R-134a in a micro-channel heat exchanger. The micro-channel heat exchanger used in this study was a sort of plate heat exchanger. Micro-channels were fabricated on the SUS304 plate by the photo-etching process: 13 sheets of plates were stacked and bonded by the diffusion bonding process. The effects of the evaporating temperature, mass flux of R-134a, and inlet temperature of water were examined. As the difference between the inlet temperatures of R-134a and water increased, the heat transfer rate increased. The evaporative heat transfer coefficients obtained in this study range from 0.67 to 6.23 kW/$m^2{\cdot}^{\circ}C$. The experimental correlation for the Nusselt number as a function of the Reynold number and $\Theta$ was suggested for the micro-channel heat exchanger.

Impedance Spectroscopic Properties of Mn Deposition on Al Oxide Layer (Al 양극산화피막에서 Mn전착에 관한 임피던스 연구)

  • Oh, Han Jun;Jang, Kyung Wook;Chi, Choong Soo
    • Journal of the Korean Chemical Society
    • /
    • v.43 no.1
    • /
    • pp.23-29
    • /
    • 1999
  • The Al oxide layer formed in 1M $H_2SO_4$ solution and the influence of applied frequency for electrodeposition of Mn on Al oxide layer were characterized using by impedance spectroscopy. Mn compounds were electrodeposited at the base of pores during deposition with applied low frequency voltage. For the Mn deposited oxide layer at 6OHz and 5Hz in 1 g/L $KMnO_4$ solution, in equivalent circuit for interpretation, the resistance ($R_2$) and capacitance ($C_2$) were considered to be due to deposition of Mn on base of pore. The electrochemical behavior of barrier layer and porous oxide layer on Al have been characterized by capacitance ($C_b$) and Young capacitance ($C_Y$) in equivalent circuit model.

  • PDF

Improvement of Convection by Pulsatile Blood Pump in High Flux Hemodialysis System (고 유량 혈액 투석 시스템에서 박동류 펌프에 대한 대류 향상에 관한 연구)

  • Choi, D.S.;Um, K.M.;Lee, J.C.;Lee, S.R.;Mun, C.H.;Choi, H.;Min, B.G.;Kim, H.C.
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.5
    • /
    • pp.376-383
    • /
    • 2008
  • High-flux dialysis treatment removes various toxins via diffusion as well as convection, which is induced by ultrafiltration and backfiltration. In this study, in vitro (Using the distilled water and the bovine's blood) comparison test was performed to determine whether utilization of a high flux dialyzer paired with different pumps would increase the efficiency of convection. At the same blood flow rates, a pulsatile pump and a roller pump were employed to propel the distilled water and bovine whole blood to a high flux dialyzer. Pressures at the dialyzer inlet and outlet in the blood circuit and in the dialysate circuit were measured, respectively. From these data, we calculated the transmembrane pressure and predicted the ultrafiltration and backfiltration rates developed by both pumps. Using the bovine's blood experiment, ultrafiltration and backfiltration rates were 1.6 times higher with the pulsatile pump than with the roller pump. We conclude that utilization of a pulsatile pump in high flux hemodialysis treatments increases ultrafiltration volume, compared with a roller pump under conditions of the same blood flow rate.