• Title/Summary/Keyword: R-600a

Search Result 784, Processing Time 0.031 seconds

Evaluation of Age-dependent Crow′s Feet in Korean Women (한국여성의 연령별 눈가 주름의 정량 분석)

  • 이미영;김은정;이희경;서영경;이민선;고재숙
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.30 no.1
    • /
    • pp.85-91
    • /
    • 2004
  • In this study, we evaluated the crow's feet of 152 Korean women by using visual assessment established by our research group and mechanical assessment, Skin Visiometer SV 600. The volunteers were divided into 3 groups according to age; the group I of 30's was 43, the group II of 40's was 75, the group III of 50's was 34. The wrinkle score by visual assessment showed tendency to increase according to age and was statistically significant different among those three age groups (P 〈 0.05). But there was no significant difference between the left and the right of crow's feet. The 5 wrinkle parameters (RI, R2, R3, R4, R5) of mechanical assessment varied as age and the Rl, R4, and R5 showed statistically significant difference among three age groups (P 〈 0.05). However there was no significant difference between the left and the right of crow's feet. The volunteers were divided into 3 groups according to wrinkle score; (0-3 grade for group A, 4-6 grade for group B, 7-9 grade for group C). Only R4 and R5 showed significant difference between group A and group C (P 〈 0.05). It was suggested that visual scoring criteria applied in this study was related to R4 and R5 and was useful in investigating in fine wrinkles.

A New Pixel Structure for Active-Matrix Organic Light Emitting Diode

  • Choi, Sang-Moo;Kwon, Oh-Kyong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.881-884
    • /
    • 2003
  • We propose a new pixel structure for Active Matrix OLED (AMOLED). The proposed pixel structure can display full color images by compensating threshold voltage (Vth) variation of driving TFTs. And we obtain an improved contrast ratio(C/R) of higher than 600:1

  • PDF

Performance characteristics of a multi type refrigerator (R600a를 이용한 소형 멀티형 냉장고 시스템의 성능특성에 대한 실험적 연구)

  • Ahn, Ji-Hoon;Jang, Yong-Hee;Kim, Yong-Chan;Jang, Ui-Young;Park, Yong-Jong
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.292-297
    • /
    • 2008
  • Various types of refrigerators become popular in the market such as a common refrigerator, kimchi refrigerator and wine cellar. It is required to develop a multi function refrigerator which has different purposes in each evaporator. In this study, the performance of a multi type refrigerator system, which consists of one machine room and three evaporators, was measured in a bench type multi refrigerator. The multi type refrigerator system was tested by varying the number of refrigerator cabinet, refrigerant charge amount, temperature condition. Based on experimental data, the multi type refrigerator showed better performance than the conventional refrigerator(single type) At the same external load condition, the COP of the multi type refrigerator was $1.22{\sim}1.29$, but the COP of the single type refrigerator was 1.0.

  • PDF

Fabrication and Test of the 3.8 ㎸ Resistive SFCL Based on YBCO Films (3.8 ㎸급 7직렬 저항형 고온초전도한류기의 제작 및 시험)

  • 심정욱;김혜림;현옥배;박권배;이방욱;강종성;오일성
    • Progress in Superconductivity
    • /
    • v.5 no.2
    • /
    • pp.136-140
    • /
    • 2004
  • We fabricated and tested a resistive superconducting fault current limiters (SFCL) operated at 3.8 ㎸ based on YBCO thin films. The SFCL was composed of 7 components connected in series. Each component was designed to be capable of current limiting at 600 V, and has a SiC shunt resistor ( $R_{s}$) of 40 Ω in Parallel. Short circuit tests were carried out fur 0 and 90 degree faults lasting fur 5 cycles. The test results showed that the 7 components were quenched simultaneously under the safe quenches and evenly shared the applied voltage. The SFCL successfully suppressed the fault currents below 94 $A_{peak}$ within the quarter cycle after fault.t.t.

  • PDF

Changes of Chemical Bond in Woody Charcoal from Different Carbonization Temperatures (목질탄화물 내의 화학 결합 변화)

  • Jo, Tae-Su;Lee, Oh-Kyu;Choi, Joon-Weon;Cho, Sung-Taig;Kim, Suk-Kuwon
    • Journal of the Korean Wood Science and Technology
    • /
    • v.37 no.1
    • /
    • pp.87-93
    • /
    • 2009
  • Properties and chemical bonding of wood charcoal were investigated to understand the chemistry occurring in wood carbonization. From the pH changes of wood charcoal, it is revealed that it becomes acidic to weakly basic for charcoal carbonized at about $300^{\circ}C$, whereas it turns to basic at higher carbonization temperature higher than $600^{\circ}C$. Also, the ratio of carbon atoms in the charcoal was increased with increasing the carbonization temperature, while those of oxygen and hydrogen atoms. This tendency was significant when the carbonization temperature was increased up to $600^{\circ}C$ and the ratio changes of the atoms became stable at above $600^{\circ}C$. In the changes of chemical bonding, the ratio of C-C bonding was increased and those of C-O-H and C-O-R bonding was decreased significantly. It is considered that bondings connected to oxygen atoms tends to be broken, and the ratio of C-C bonding increased. Consequently, it is expected that this change may causes occurrence of new functional groups. In addition to that, it seems to be that the chemical bondings undergo the partial decomposition, formation, and recombination steps, Because ratio of C=O bonding tended to be increased or decreased by increasing the carbonization temperature. This understanding of chemical bond changes in charcoal can be a compensative consideration on the knowledges made only by physical parameters in the properties of micro-pore which has limited to explain the phenomenon. Also, it is considered that this can be treated as a basic knowledge for upgrading and development of use of wood charcoal.

R-22 and R-410A Condensation in Flat Aluminum Multi-Channel Tubes

  • Kim, Nae-Hyun;Min, Chang-Keun;Jung, Ho-Jong
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.11 no.3
    • /
    • pp.114-124
    • /
    • 2003
  • In this study, condensation heat transfer tests were conducted in flat aluminum multi-channel tubes using R-410A, and the results are compared with those of R-22. The flat tubes have two internal geometries; one with smooth inner surface and the other with micro-fins. Data are presented for the following range of variables; vapor Quality (0.1∼0.9), mass flux (200∼600 kg/$m^2$s) and heat flux (5∼15 kW/$m^2$). Results show that the effect of surface tension drainage on the fin surface is more pronounced for R-22 than R-410A. The smaller Weber number of R-22 may be responsible. For the smooth tube, the heat transfer coefficient of R-410A is slightly larger than that of R-22. For the micro-fin tube, however, the trend is reversed. Possible reason is provided considering physical properties of the refrigerants. For the smooth tube, Webb's correlation predicts the data reasonably well. For the micro-fin tube, the Yang and Webb model was modified to correlate the present data. The modified model adequately predicts the data.

Characteristics of Hydrocarbon Refrigerants on Evaporating Heat Transfer and Pressure Drop

  • Lee Ho-Saeng;Phan Thanh Tong;Yoon Jung-In
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.14 no.3
    • /
    • pp.102-109
    • /
    • 2006
  • Experimental results for heat transfer characteristics and pressure gradients of HCs refrigerants R-290, R-600a, R-1270 and HCFC refrigerant R-22 during evaporating inside horizontal double pipe heat exchangers are presented. The test sections which has one tube diameter of 12.70 mm with 0.89 mm wall thickness, another tube diameter of 9.52 mm with 0.76 mm wall thickness are used for this investigation. The local evaporating heat transfer coefficients of hydrocarbon refrigerants were higher than that of R-22. The average evaporating heat transfer coefficient increased with the increase of the mass flux, with the higher values in hydrocarbon refrigerants than R-22. Hydrocarbon refrigerants have higher pressure drop than R-22. Those results from the investigation can be used in the design of heat exchangers using hydrocarbons as the refrigerant for the air-conditioning systems.

Production of 3-Hydroxypropionic Acid from Acrylic Acid by Newly Isolated Rhodococcus erythropolis LG12

  • Lee, Sang-Hyun;Park, Si-Jae;Park, Oh-Jin;Cho, Jun-Hyeong;Rhee, Joo-Won
    • Journal of Microbiology and Biotechnology
    • /
    • v.19 no.5
    • /
    • pp.474-481
    • /
    • 2009
  • A novel microorganism, designated as LG12, was isolated from soil based on its ability to use acrylic acid as the sole carbon source. An electron microscopic analysis of its morphological characteristics and phylogenetic classification by 16S rRNA homology showed that the LG12 strain belongs to Rhodococcus erythropolis. R. erythropolis LG12 was able to metabolize a high concentration of acrylic acid (up to 40 g/l). In addition, R. erythropolis LG12 exhibited the highest acrylic acid-degrading activity among the tested microorganisms, including R. rhodochrous, R. equi, R. rubber, Candida rugosa, and Bacillus cereus. The effect of the culture conditions of R. erythropo/is LG12 on the production of 3-hydroxypropionic acid (3HP) from acrylic acid was also examined. To enhance the production of 3HP, acrylic acid-assimilating activity was induced by adding 1 mM acrylic acid to the culture medium when the cell density reached an $OD_{600}$ of 5. Further cultivation of R. erythropo/is LG 12 with 40 g/l of acrylic acid resulted in the production of 17.5 g/l of 3HP with a molar conversion yield of 44% and productivity of 0.22 g/l/h at $30^{\circ}C$ after 72 h.

Occurrence Pattern and Control Method of Water - foxtail(Alopecurus aequalis Ohwi) in No - tillage Paddy (무경운답(無耕耘畓)에서 둑새풀의 발생양상(發生樣相)과 방제방법(防除方法))

  • Hong, Kwang-Pyo;Kim, Jang-Yong;Kang, Dong-Ju;Shin, Won-Gyo
    • Korean Journal of Weed Science
    • /
    • v.16 no.3
    • /
    • pp.176-180
    • /
    • 1996
  • In order to estabilish a labour-saved and environmental protected paddy rice system in Southern Korea, new system, called no-tillage paddy system, was proposed and investigated from 1988 to 1996. Under the no-tillage paddy system, occurrence pattern, control value and regrowth of water foxtail each treatment(herbicides and application dates), and occurrence of volunteer rice plant in application dates of herbicide were investigated. The growth of water-foxtil was markedly increased from middle of May and no. of tillers and dry weight of water-foxtail increased up to 3rd crop year in no-tillage. Glyphosate application for control of water-foxtail was 20 days before transplanting. And when the soil under the no-tillage paddy system in May 1 and May 10 application of herbicide machine-transplanted with 8-day-old seedlings missing hills were increased compared to April 20 and early growth stages of machine transplanted of rice in April 20 applications of herbicide showed increased plant height, no. of tillers of rice, occurrence of volunteer rice plants from the shattered seeds were 1,600plants/10a and decreased in May 10 compared to April 20 and May 1.

  • PDF

Investigation of the optimum condition for the quantitative analysis of Cu sample by Laser induced breakdown spectroscopy (구리 시료의 정량분석을 위한 LIBS의 최적조건 연구)

  • Kim, Seunghyun;Shin, Heesung;Ju, Junesik;Kim, Hodong
    • Analytical Science and Technology
    • /
    • v.22 no.2
    • /
    • pp.141-147
    • /
    • 2009
  • A laser induced breakdown spectroscopy (LIBS) measurement was carried out to derive an optimized measurement condition with a high reproducibility and to grow a plasma sphere to 20 mm high under a 600 mtorr vacuum in order to improve an accuracy of measurement. The measurement of the plasma was taken at a 6.0 mm distance, in the direction of a plasma sphere, from a sample. This location belongs to the outer sphere region in the plasma. The calibration curve of 'Ni' and 'Cu' was acquired by the signal intensity ratio and the atomic ratio for the samples, and linear regression of 'Cu' was $R^2$=0.9886, and the linear regression of 'Ni' was $R^2$=0.9988. The accuracy of LIBS was improved pre-existence as the measurement error of 'Ni' was 0.78%.