• Title/Summary/Keyword: R&D input

Search Result 744, Processing Time 0.029 seconds

Identification of Normally Operating High-Voltage Cables beyond Expected Life time (예상 수명을 초과하여 정상적으로 동작하는 고압 케이블의 확인)

  • Um, Kee-Hong;Lee, Kwan-Woo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.5
    • /
    • pp.207-212
    • /
    • 2015
  • Continuous, high-quality supply of electrical energy is the backbone of any modern economy. Any equipment operating at a power station must be reliable and safe. All major power supply components such as transformers, cables, generators, and switchgear need to be kept in perfect operating condition. The lifetime of power cables, used as the main means of transferring electric power, is understood to be about 30 years, from the time of manufacturing. The dielectrics between two conductors of a cable must be able to withstand electrical stresses from high-voltage input. This condition should be verified throughout the lifetime of the cable system. Several techniques, such as VLF-tan${\delta}$, partial discharge, and insulation resistance are used in order to determine the operating conditions of cables. In this paper, we present our work on insulation resistance to diagnose cables in operation at the Western Power station in Taean, Chungcheong Namdo Province, South Korea. As a result we have found cables the life time of which is 38 years.

Position Control of Wheeled Mobile Robot using Self-Structured Neural Network Model (자율가변 구조의 신경망 모델을 이용한 구륜 이동 로봇의 위치 제어)

  • Kim, Ki-Yeoul;Kim, Sung-Hoe;Kim, Hyun;Lim, Ho;Jeong, Young-Hwa
    • The Journal of Information Technology
    • /
    • v.4 no.2
    • /
    • pp.117-127
    • /
    • 2001
  • A self-structured neural network algorithm that finds optimal fuzzy membership functions and nile base to fuzzy model is proposed and a fuzzy-neural network controller is designed to get more accurate position and velocity control of wheeled mobile robot. This procedure that is composed of three steps has its own unique process at each step. The elements of output term set are increased at first step and then the rule base Is varied according to increase of the elements. The adjusted controller is in competition with controller which doesn't include any increased elements. The adjusted controller will be removed if the control-law lost. Otherwise, the controller is replaced with the adjusted system. After finished regulation of output term set and rule base, searching for input membership functions is processed with constraints and fine tuning of output membership functions is done.

  • PDF

A Study on the Characteristics of Science and Technology Policy in Korea (한국 과학기술정책의 특성에 관한 시론적 고찰)

  • Song Sung-Soo
    • Journal of Science and Technology Studies
    • /
    • v.2 no.1 s.3
    • /
    • pp.63-83
    • /
    • 2002
  • This article examines the historical and general characteristics of science and technology policy in Korea. Historical characteristics are analyzed through formation period, growth period, and transition period. Korea institutional sis for the promotion of science and technology was made from the initial stage of industrialization. As national R&D programs were launched, technological activities in the private sector were rapidly increased from the 1980s. Korea pursued new directions of science and technology policy with the formation of related laws and Plans from the late 1990s. General characteristics are analyzed by the concept of 'policy regime'. The prime policy goal of science and technology policy in Korea has been related to industrial development so far. In the policy means, input element has been increased focusing on the external aspects. Bureaucratic policy culture has dominated other cultures including economic culture, academic culture, and civic culture.

  • PDF

Modeling and Interoperability Test Case Generation of a Real-Time QoS Monitoring Protocol

  • Chin, Byoung-Moon;Kim, Sung-Un;Kang, Sung-Won;Park, Chee-Hang
    • ETRI Journal
    • /
    • v.21 no.4
    • /
    • pp.52-64
    • /
    • 1999
  • QoS monitoring is a kind of real-time systems which allows each level of the system to track the ongoing QoS levels achieved by the lower network layers. For these systems, real-time communications between corresponding transport protocol objects is essential for their correct behavior. When two or more entities are employed to perform a certain task as in the case of communication protocols, the capability to do so is called interoperability and considered as the essential aspect of correctness of communication systems. This paper describes a formal approach on modeling and interoperability test case generation of a real-time QoS monitoring protocol. For this, we specify the behavior of flow monitoring of transport layer QoS protocol, i.e., METS protocol, which is proposed to address QoS from an end-to-end's point of view, based on QoS architecture model which includes ATM net work in lower layers. We use a real-time Input/Output finite State Machine to model the behavior of real-time flow monitoring over time. From the modeled real-time I/OFSM, we generate interoperability test cases to check the correctness of METS protocol's flow monitoring behaviors for two end systems. A new approach to efficient interoperability testing is described and the method of interoperability test cases generation is shown with the example of METS protocol's flow monitoring. The current TTCN is not appropriate for testing real-time and multimedia systems. Because test events in TTCN are for message-based system and not for stream-based systems, the real-time in TTCN can only be approximated. This paper also proposes the notation of real-time Abstract Test Suite by means of real-time extension of TTCN. This approach gives the advantages that only a few syntactical changes are necessary, and TTCN and real-time TTCN are compatible. This formal approach on interoperability testing can be applied to the real-time protocols related to IMT-2000, B-ISDN and real-time systems.

  • PDF

Effects of Symmetrically Arranged Heat Sources on the Heat Release Performance of Extruded-Type Heat Sinks (열원의 대칭 배열에 따른 압출형 히트싱크의 방열성능 연구)

  • Ku, Min Ye;Shin, Hon Chung;Lee, Gyo Woo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.2
    • /
    • pp.119-126
    • /
    • 2016
  • In this study we investigated the effects of symmetrically arranged heat sources on the heat release performances of extruded-type heat sinks through experiments and thermal fluid simulations. Also, based on the results we suggested a high-efficiency and cost-effective heat sink for a solar inverter cooling system. In this parametric study, the temperatures between heaters on the base plate and the heat release rates were investigated with respect to the arrangements of heat sources and amounts of heat input. Based on the results we believe that the use of both sides of the heat sink is the preferred method for releasing the heat from the heat source to the ambient environment rather than the use of a single side of the heat sink. Also from the results, it is believed that the symmetric arrangement of the heat sources is recommended to achieve a higher rate of heat transfer. From the results of the thermal fluid simulation, it was possible to confirm the qualitative agreement with the experimental results. Finally, quantitative comparison with respect to mass flow rates, heat inputs, and arrangements of the heat source was also performed.

Method for Recognition and Generation of High Precision Range Delay in High Range Resolution Pulse Radar (고해상도 펄스 레이더에서 고정밀 거리 지연 인식 및 생성 방법)

  • Hong, Young-Gon;Kim, Sang-Ho;Kim, Yoon-Jin;Woo, Soen-Koel;Lee, Man-Hee;Ahn, Se-Hwan;Kim, Hong-Rak
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.2
    • /
    • pp.133-140
    • /
    • 2020
  • We discuss the method of a high precision range trigger and generation for a high range resolution radar. To verify the designed range resolution performance, we use test-equipments which can absolutely make a precision range shorter than the desined range resolution. The accuracy of generated range is proportional to the system reference clock. However, the system main processor is limited to input reference clocks and a higher available one is expensive in the conventional method. To solve this problem, we proposed that the range trigger and generation method using multi-phase-shiftings and integration. Through a experiment, we verified that the proposed method made problems which can be ocurred in the conventional method clear.

Bioequivalence and Pharmacokinetic study of Gabapentin 300mg Capsules using Liquid Chromatography-Tandem Mass Spectrometry (LC/MS/MS) in Volunteers (LC/MS/MS를 이용한 가바펜틴 300 mg 캡슐의 성인 지원자에 대한 생물학적 동등성 및 약물동태 연구)

  • Jeong, Ji-Hoon;Kwon, Jun-Tack;Yun, Hwi-Yeol;Kang, Won-Ku;Kwon, Kwang-Il
    • Korean Journal of Clinical Pharmacy
    • /
    • v.16 no.1
    • /
    • pp.63-68
    • /
    • 2006
  • Gabapentin, 1-(aminomethyl-1-cyclohexyl)acetic acid, is anew antiepileptic drug related to ${\gamma}-aminobutyric$ acid(GABA) currently being introduced in therapy worldwide. The bioavailability and pharmacokinetics of gabapentin capsules were examined in 22 volunteers who received a single oral dose in the fasting state by randomized balanced $2{\times}2$ crossover design. After dosing, blood samples were collected for a period of 24 hours and analyzed by liquid chromatography-tandem mass spectrometry (LC/MS/MS). Time course of plasma gabapentin concentration was analyzed with non-compartmental and compartmental approaches. $WinNonlin^{(R)}$, the kinetic computer program, was used for compartmental analysis. One compartment model with first-order input, first-order output with no lag time and weighting by $1/(predieted\;y)^2$ was chosen as the most appropriate pharmacokinetic model for the volunteers. The major pharmacokinetic parameters $(AUC_{0-24hr},\;AUC_{inf},\;C_{max}\;and\;T_{max})$ and other parameters $(K_a,\;K_{el},\;V_d/F\;and\;Cl/F)$ of $Gapentin^{TM}$ (test drug) and $Neurontin^{TM}$ (reference drug) were estimated by non-compartmental analysis and compartmental analysis. The 90% confidence intervals of mean difference of logarithmic transformed $AUC_{0-24hr}\;and\;C_{max}$ were $log(0.9106){\sim}log(1.l254)\;and\;log(0.8521){\sim}log(1.0505)$, respectively. It shows that the bioavailability of the test drug is equivalent with that of the reference drug. There was no statistically significant difference between the two drugs in all pharmacokinetic parameters.

  • PDF

Single-Electron Logic Cells and SET/FET Hybrid Integrated Circuits

  • Kim, S.J.;Lee, C.K.;Lee, J.U.;Choi, S.J.;Hwang, J.H.;Lee, S.E.;Choi, J.B.;Park, K.S.;Lee, W.H.;Paik, I.B.;Kang, J.S.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.6 no.1
    • /
    • pp.52-58
    • /
    • 2006
  • Single-electron transistor (SET)-based logic cells and SET/FET hybrid integrated circuits have been fabricated on SOI chips. The input-output voltage transfer characteristic of the SET-based complementary logic cell shows an inverting behavior where the output voltage gain is estimated to be about 1.2 at 4.2K. The SET/FET output driver, consisting of one SET and three FETs, yields a high voltage gain of 13 and power amplification with a wide-range output window for driving next circuit. Finally, the SET/FET literal gate for a multi-valued logic cell, comprising of an SET, an FET and a constant-current load, displays a periodic voltage output of high/low level multiple switching with a swing as high as 200mV. The multiple switching functionality of all the fabricated logic circuits could be enhanced by utilizing a side gate incorporated to each SET component to enable the phase control of Coulomb oscillations, which is one of the unique characteristics of the SET-based logic circuits.

Genetic lesion matching algorithm using medical image (의료영상 이미지를 이용한 유전병변 정합 알고리즘)

  • Cho, Young-bok;Woo, Sung-Hee;Lee, Sang-Ho;Han, Chang-Su
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.5
    • /
    • pp.960-966
    • /
    • 2017
  • In this paper, we proposed an algorithm that can extract lesion by inputting a medical image. Feature points are extracted using SIFT algorithm to extract genetic training of medical image. To increase the intensity of the feature points, the input image and that raining image are matched using vector similarity and the lesion is extracted. The vector similarity match can quickly lead to lesions. Since the direction vector is generated from the local feature point pair, the direction itself only shows the local feature, but it has the advantage of comparing the similarity between the other vectors existing between the two images and expanding to the global feature. The experimental results show that the lesion matching error rate is 1.02% and the processing speed is improved by about 40% compared to the case of not using the feature point intensity information.

A New DC Ripple-Voltage Suppression Scheme in Three Phase Buck Diode Rectifiers with Unity Power Factor (단위 역률을 갖는 3상 BUCK 다이오드 정류기에서의 새로운 DC 리플-전압 저감 기법)

  • Lee, Dong-Yun;Choy, Ick;Song, Joong-Ho;Choi, Ju-Yeop;Kim, Kwang-Bae;Hyun, Dong-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.2
    • /
    • pp.154-162
    • /
    • 2000
  • A technique to suppress the low frequency ripple voltage of the DC output ${\gamma}$oltage in three-phase buck d diode rectifiers is presented in this paper. The proposed pulse frequency modulation method is employed to r regulate the output voltage of the buck diode rectifiers and guarantee zero-current switching of the switch over the Vvide load range. The pulse frequency control method used in tIns paper shows generally good p performance such as low THD of the input line current and unity power factor. In addition, the pulse f freιluency method can be effectively used to suppress the low frequency voltage ripple appeared in the dc output voltage. The proposed technique illustrates its validity and effectiveness through the respective s simulations and experiments.

  • PDF