• Title/Summary/Keyword: Quartz Crystal Microbalance (QCM)

Search Result 93, Processing Time 0.029 seconds

Optimization of Quartz Crystal Microbalance-Precipitation Sensor Measuring Acetylcholinesterase Activity

  • Kim, Nam-Soo;Park, In-Seon;Kim, Dong-Kyung
    • Journal of Microbiology and Biotechnology
    • /
    • v.16 no.10
    • /
    • pp.1523-1528
    • /
    • 2006
  • The optimization of a batch-type quartz crystal microbalance (QCM)-precipitation sensor measuring acetylcholinesterase (AChE) activity was conducted. To covalently bind AChE onto the gold electrode of a QCM surface, glutaraldehyde cross-linking to a cystamine self-assembled monolayer was tried at different cystamine concentrations. At the optimum conditions of the QCM-precipitation sensor, 0.1 M potassium phosphate buffer (pH 8.0), containing 0.01% Tween 80, was used as the reaction buffer, with the enzyme amount of 5 units for immobilization and the substrate concentration of 50 mg/ml. The current biosensor might find a future applicability to the sum parameter detection on organophosphorus and carbamate pesticides.

Resistance and Frequency Properties Analysis of QCM Coated with LB Films (LB막이 누적된 QCM의 저항 및 주파수 특성해석)

  • 강현욱;진철남;김정명;권명수
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.465-467
    • /
    • 1997
  • The oscillating properties of quartz Crystal Microbalance(QCM) were analyzed by electrical measurement. We tried to analyze the properties of quartz crystal coated with Langmuir-Bladgett(LB) films using the frequency and resistance at resonance in the electrical equivalent circuit. The resonant frequency was decreased linearly as to layers of LB films, however, there are some gap between theoretical values, Sauerbrey's equation and experimental values. The resistance was increase nonlinearly as to layers.

  • PDF

Phase Equilibrium Measurement of Gas Hydrate with Quartz Crystal Microbalance (QCM(Quartz Crystal Microbalance)을 이용한 가스 하이드레이트 상평형 측정 방법)

  • Lee, Bo Ram;Sa, Jeong-Hoon;Park, Da-Hye;Lee, Kun-Hong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.150.1-150.1
    • /
    • 2010
  • 가스 하이드레이트는 물분자와 저분자량의 가스분자가 고압과 저온에서 수소결합을 이루며 형성되는 결정성 화합물을 말한다. 최근 가스 하이드레이트의 물리적 특성과 형성 원리를 이용하여 다양한 분야로의 적용 연구가 수행되고 있는데 이의 효과적 달성을 위해서는 가스 하이드레이트의 상평형 연구가 필수적이다. 기존에 수행되는 상평형 실험 방법은 온도의 변화에 따라 하이드레이트를 해리시키고 압력의 변곡점을 찾는 것으로 최소 24시간이 소요되지만, 본 연구진이 제안하는 QCM을 이용한 방법은 1 ng의 무게에 1 Hz의 변화를 나타내는 수정진동자의 민감성을 이용한 것으로 약 2~3시간 내에 상평형 실험을 수행할 수 있고, 하이드레이트의 기억효과(Memory Effect)를 이용하여 연속적인 상평형 실험도 가능하다. 본 연구에서는 QCM 반응기의 원리 및 실험 방법에 대하여 설명하고 열역학적 촉진제를 첨가한 상평형 실험결과를 제시함으로써 상대적으로 저렴한 가격으로 다양한 촉진제와 억제제 첨가 시 나타나는 상평형 효과를 빠른 시간 내에 선별할 수 있는 방법으로 QCM을 이용한 방법을 제안하고자 한다.

  • PDF

Quartz Crystal Microbalance Modified by a Novel Vapor Diffused Molecular Assembly Technique and Measurement of Chiral Mandelic Acid (기상확산 자기조립화법에 QCM수식과 Madelic Acid 키랄물질 측정)

  • Kim, JongMin;Kim, SeungJin;Woo, SunYoung;Jang, SukHee;Kim, Woo-Sik;Chang, SangMok
    • Korean Chemical Engineering Research
    • /
    • v.48 no.5
    • /
    • pp.574-582
    • /
    • 2010
  • In this study, the possibility of a quartz crystal micro-balance(QCM) modification of crystallization of L-Penicillamine and D-Penicillamine with a Vapor Diffused Molecular Assembly Technique and its application to the R-(-)-Mandelic acid and S-(+)- Mandelic acid measurement was investigated. The 3-dimensional structures of L-Penicillamine and D-Penicillamine on the surface of QCM were verified to be different from each other through QCM and AFM analyses. The D-Penicillamine modified QCM had specific recognition to the R-(-)-Mandelic acid, but L-Penicillamine modified QCM had no specificity to the R-(-)-Mandelic acid and S-(+)- Mandelic acid. From these results, it was known that the QCM could be modified with various selective meterials via VDMA, and the chiral isomer such as a Mandelic acid isomer could be detected by using a modified QCM.

Sensing and Degradation Properties in the Quartz Crystal Microbalance Coated with the PVC and the Lipid Blended Materials (지질과 PVC의 혼합액을 감응막으로 도포한 수정진동자 가스센서의 센싱 및 열화특성)

  • Jang, Kyung-Uk;Kim, Myung-Ho;Choi, Myung-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 2000.07e
    • /
    • pp.44-47
    • /
    • 2000
  • In the recognition of the gases using the quartz crystal microbalance (QCM) coated with the film materials, it is important to obtain the recognition ability of gases, and the stability of film coated above the QCM. Especially, the thickness of film coated above the QCM is decreased according with the using circumstance and time of QCM gas sensor. Therefore, the sensing characteristics of film is changed with these. In this paper, we coated the lipid PC (Phosphatidyl Choline) materials varing with the blended amount of PVC(Poly Vinyl Chloride) and solution (Tetra Hydrofan:THF) above QCM to obtain the sensitive and the stability of lipid PC film. QCM gas sensors coated with film materials were measured the frequency change in the chamber of stationary gas sensing system injected 1-hexane, ethyl acetate, ethanol and benzene of $20{\mu}{\ell}$, respectively. We also measured the degradation characteristics of QCM gas sensor to show the properties of stability.

  • PDF

A QCM-based Sensor System for Detecting NO2 and SO2 (QCM기반 NO2와 SO2 감지용 센서시스템)

  • Hwang, Min-Jin;Shim, Wang Geun;Moon, Hee
    • Korean Chemical Engineering Research
    • /
    • v.51 no.2
    • /
    • pp.285-291
    • /
    • 2013
  • The effects of sensing materials, coating methods, diluent gases, and temperature have been studied in detail to make a quartz crystal microbalance based adsorption sensor system for detecting gases. In particular, sensor elements for detecting $NO_2$ and $SO_2$, that are known as major air pollutants, have been prepared by coating two different polymers, polypyrrole and poly(3,4-ethylenedioxythiophene). The sensor elements prepared in this work have high sensitivity and selectivity for $NO_2$ and $SO_2$ at ppm level concentrations. It was proven that the sensing characteristics and response rate of the sensing elements are highly dependent on the coating method and the loading mass of sensing materials.

Measurement of Isoelectric Point of Amine Oxide Zwitterionic Surfactant by QCM (Quartz Crystal Microbalance) (QCM (Quartz Crystal Microbalance)을 활용한 Amine Oxide 양쪽성 계면활성제의 등전점 측정에 관한 연구)

  • Kim, JiSung;Park, JunSeok;Lim, JongChoo
    • Applied Chemistry for Engineering
    • /
    • v.20 no.1
    • /
    • pp.9-14
    • /
    • 2009
  • A zwitterionic surfactant shows not only detergency but also softening effect since it shows characteristics of a nonionic or an anionic surfactant above an isoelectric point, while showing characteristics of a cationic surfactant below an isoelectric point. Therefore, a zwitterionic surfactant can serve as a dual function surfactant by a single molecule through the interconversion of cleaning and softening effects depending on pH of the aqueous solution. In this study, the dual function characteristics of an amine oxide zwitterionic surfactant were investigated by measuring the zeta potential and the isoelectric point using quartz crystal microbalance (QCM). In addition, the physical properties of an amine oxide surfactant such as critical micelle concentration, surface tension, interfacial tension, contact angle and viscosity were measured and phase behavior study was also performed. The isoelectric point of an amine oxide surfactant determined by zeta potential measurement was near 7.35 and that obtained by QCM experiment was about 7.4, where both results were found to be close to the value reported in the literature.

Application of Quartz Crystal Microbalance to Understanding the Transport of Microplastics in Soil and Groundwater (토양-지하수내 미세플라스틱 거동 연구를 위한 수정진동자미세저울 기술 소개)

  • Kim, Juhyeok;Myeong, Hyeonah;Son, Sangbo;Kwon, Kideok D.
    • Korean Journal of Mineralogy and Petrology
    • /
    • v.33 no.4
    • /
    • pp.463-475
    • /
    • 2020
  • Presence of microplastics in soil and groundwater has recently been reported and environmental concerns are raised as to the plastic pollution. In the subsurface environment, clay minerals and metal oxide minerals are commonly found as finely dispersed states. Because the minerals have high sorption capacities for diverse pollutants, interactions with mineral surface play an important role in the transport of microplastics in groundwater. Accordingly, environmental mineralogy investigating the interactions between microplastics and mineral surfaces is the essential research area to understand the fate and transport of microplastics in the subsurface environment. The microplastic-mineral surface research requires molecular- to nano-scale analyses to be able to probe the relatively weak interactions between them. The current report introduces a nano-scale analysis tool called quartz crystal microbalance (QCM) that can measure the sorbed/desorbed mass of nanoplastics on mineral surfaces at the level of a few nanograms (~10-9 g). This report briefly reviews the main principles in the QCM measurement and discusses applications of QCM to the environmental mineralogy research.

Immunoassay of haptoglobin and transferrin with proteinG-containing QCM sensor chip and unpurified antiserum (Protein G를 포함하는 수정미소저울 센서 칩과 정제되지 않은 항혈청을 이용한 헵토글로빈과 트랜스페린의 면역분석)

  • Ha, In-Young;Choi, Suk-Jung
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.5
    • /
    • pp.380-386
    • /
    • 2008
  • Quartz crystal microbalance immunosensor has a capacity to perform a label-free and real time detection of a trace amount of analyte through the specific interaction between antibody and antigen. However, immobilization of antibody molecules on the sensor surface is a troublesome procedure for researchers who are not experienced in chemistry. Protein G has a specific affinity to antibody and would serve as a capturing agent for antibody when immobilized on the sensor surface. In this work, we prepared a protein G sensor chip by immobilizing protein G on the surface of quartz crystal microbalance and examined its capability to detect human haptoglobin or human transferrin with unpurified corresponding antiserum. Specific and dose dependent response was observed when the protein G chip was used for detection of antigens after saturated with antiserum. We also verified several advantageous aspects of the protein G chip such as improved flexibility and sensitivity.

Measurement of Isoelectric Point of Betaine Zwitterionic Surfactant by QCM(Quartz Crystal Microbalance) (QCM(Quartz Crystal Microbalance)을 이용한 Betaine 양쪽성 계면활성제의 등전점 측정)

  • Kim, Ji Sung;Park, Jun Seok;Lim, Jong Choo
    • Korean Chemical Engineering Research
    • /
    • v.47 no.1
    • /
    • pp.31-37
    • /
    • 2009
  • A zwitterionic surfactant shows not only detergency but also mildness effect since it shows characteristics of a nonionic or an anionic surfactant above an isoelectric point, while showing characteristics of a cationic surfactant below an isoelectric point. Therefore, a zwitterionic surfactant can serve as a dual function surfactant by a single molecule through the interconversion of cleaning and softening effects depending on pH variations of the aqueous solution. In this study, physical properties of betaine surfactant such as CMC, surface tension, interfacial tension, contact angle and viscosity were measured and phase behavior study was performed. Also dual function characteristics of betaine zwitterionic surfactant were investigated by measuring an isoelectric point using QCM(quartz crystal microbalance) and zeta potential measurement. The CMC of betaine surfactant was near $10^{-4}mol/L$ and the surface tension at CMC was about 32 mN/m. The interfacial tension between 1 wt% aqueous solution and n-decane measured by spinning drop tensiometer at pH 2~10 resulted in an increase in interfacial tension until pH 5 and a decrease with pH after 5 and equilibration time showed the similar trend with an increase in pH. The isoelectric point of betaine surfactant measured by QCM experiment was found to exist between 3.0 and 3.3, which is the same as the result determined by zeta potential measurement.