• 제목/요약/키워드: Quantum Sensors

검색결과 95건 처리시간 0.03초

저잡음 심자도측정시스템 개발을 위한 고온초전도 SQUID 센서의 제작 (Fabrication of HTS SQUID Sensors for the Application to a High S/N Ratio Magnetocardiograph System)

  • 김인선;유권규;박용기
    • Progress in Superconductivity
    • /
    • 제6권1호
    • /
    • pp.19-23
    • /
    • 2004
  • YBCO do superconducting quantum interference device (SQUID) magnetometers based on bicrystal Josephson junctions on 10 mm ${\times}$ 10 mm $SrTiO_3$ substrates have been fabricated. The pickup coil of the device was designed to have 16 parallel loops with 50-fm-wide lines. We could obtain optimised direct coupled YBCO SQUID magnetometer design with field sensitivity $B_{N}$ $\Phi$/ of $4.5 nT/\Phi_{0}$ and magnetic field noise $B_{N}$ of about $22 fT/Hz^{1}$2/ with an I/f corner frequency of 2 Hz measured inside a magnetically shielded room. Preliminary results of magnetocardiograph measurement using the HTS SQUID magnetometers show signal to noise ratio of about 110, which is comparable to the quality of a commercial MCG system based on Nb-SQUIDs.

  • PDF

Development of Contaminant Detection System using HTS SQUIDs

  • Ohtani, T.;Tanaka, S.;Narita, Y.;Ariyoshi, S.;Suzuki, S.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제17권4호
    • /
    • pp.38-42
    • /
    • 2015
  • In terms of food safety,mixture of contaminants in food is a serious problem for not only consumers but also manufacturers. In general, the target size of the metallic contaminant to be removed is 0.5 mm. However, it is a difficult task for manufacturers to achieve this target, because of lower system sensitivity. Therefore, we developed a food contaminant detection system based on high-Tc RF superconducting quantum interference devices (SQUIDs), which are highly sensitive magnetic sensors. This study aims to improve the signal to noise ratio (SNR) of the system and detect a 0.5 mm diameter steel ball. Using a real time digital signal processing technique along with analog band-pass filters, we improved the SNR of the system. Owing to the improved SNR, a steel ball with a diameter as small as 0.3 mm, with stand-off distance of 117 mm was successfully detected. These results suggest that the proposed system is a promising candidate for the detection of metallic contaminants in food products.

a-Se 광도전막을 이용한 HARP 촬상관의 제작 및 특성 (Fabrication and Characteristics of HARP Image Pickup Tube Using a-Se Photoconductive Film)

  • 박욱동;김기완
    • 센서학회지
    • /
    • 제7권1호
    • /
    • pp.17-22
    • /
    • 1998
  • $4{\mu}m$ 두께의 a-Se 광도전막을 이용한 HARP (high-gain avalanche rushing amorphous photoconductor) 촬상관을 제작하고 그 특성을 조사하였다. 타겟전압이 360 V 이상으로 증가함에 따라 촬상관의 신호전류는 급격하게 증가하였으나 암전류는 490 V의 전압까지 3.2 nA이하로 억제되었다. $1.1{\times}10^{6}V/cm$의 전기장에서 440 nm의 파장에 대한 타겟의 양자효율은 약 4.3으로 나타났다. 또한 촬상관의 진폭응답은 800 TV line에서 7.5 %였으며 잔상은 3.4%였다.

  • PDF

YBCO SQUID 자력계를 이용한 자기심장검사장치 개발 (Development of magnetocardiograph system using YBCO SQUID magnetometers)

  • 김인선;오수호;임현균;이용호;이순걸;박용기
    • Progress in Superconductivity
    • /
    • 제8권2호
    • /
    • pp.158-163
    • /
    • 2007
  • YBCO do superconducting quantum interference device (SQUID) magnetometers based on bicrystal junctions have been fabricated for magnetocardiograph (MCG) measurements. We could fabricate YBCO SQUID magnetometers having magnetic field noise of about $20fT/Hz^{1/2}$ at white noise region. We have developed an MCG system employing the high performance SQUID magnetometers. The lightweight MCG system, requiring liquid nitrogen as a coolant, consists of 6-channel SQUID sensors, an adjustable patient bed with sliding motion, and data analyses software. The MCG system could record quite clear MCG signals in a room with moderate magnetic shielding. In normal operation with multi-position MCG measurements, we could obtain clear 48-point mappings of magnetic field map and current source map with high enough signal qualities far clinical trials.

  • PDF

CuInS2 나노 반도체 합성 및 표면 개질을 통한 광학적 효율 분석 연구 (Synthesis and Characterization of CuInS2 Semiconductor Nanoparticles and Evolution of Optical Properties via Surface Modification)

  • 양희승;김유진
    • 한국분말재료학회지
    • /
    • 제19권3호
    • /
    • pp.177-181
    • /
    • 2012
  • Copper composite materials have attracted wide attention for energy applications. Especially $CuInS_2$ has a desirable direct band gap of 1.5 eV, which is well matched with the solar spectrum. $CuInS_2$ nanoparticles could make it possible to develop color-tunable $CuInS_2$ nanoparticle emitter in the near-infrared region (NIR) for energy application and bio imaging sensors. In this paper, $CuInS_2$ nanoparticles were successfully synthesized by thermo-decomposition methods. Surface modification of $CuInS_2$ nanoparticles were carried out with various semiconductor materials (CdS, ZnS) for enhanced optical properties. Surface modification and silica coating of hydrophobic nanoparticles could be dispersed in polar solvent for potential applications. Their optical properties were characterized by UV-vis spectroscopy and photoluminescence spectroscopy (PL). The structures of silica coated $CuInS_2$ were observed by transmission electron microscopy (TEM).

용액 공정 기반 NiO/ZnO계 자외선 센서용 재료 특성 연구 (A Study on the Material Characteristics of the NiO/ZnO Ultraviolet Sensor Based on Solution Process)

  • 문성철;이지선;노경재;양성주;이성의
    • 한국전기전자재료학회논문지
    • /
    • 제30권8호
    • /
    • pp.508-513
    • /
    • 2017
  • Ultraviolet (UV) photodetectors are used in various industries and fields of research, including optical communication, flame sensing, missile plume detection, astronomical studies, biological sensors, and environmental research. However, general UV detectors that employ Schottky junction diodes and p-n junctions have high fabrication cost and low quantum efficiency. In this study, we investigated the characteristics of materials used to manufacture UV photodetectors in a low-cost solution process that requires easy fabrication of flexible substrates. We fabricated p-type NiO and n-type ZnO substrates with wide band gap by the sol-gel method and compared the characteristics of substrates prepared under different spin-coating and heat-treatment conditions.

비대면 실험실습 수업 경험과 비대면 상호작용 경험의 현상학적 분석 - 공과대학 신입생의 경험을 중심으로 (Phenomenological Analysis of Non-face-to-face Experiment and Non-face-to-face Interaction - Focusing on the Experiences of Engineering Freshmen)

  • 강유진
    • 공학교육연구
    • /
    • 제25권2호
    • /
    • pp.32-41
    • /
    • 2022
  • The purpose of this study was in a pandemic situation caused by COVID-19 to explore the online distance experiments and interaction of engineering freshmen, and to identify practical difficulties, resulting in to derive implications. Seven freshmen from engineering college participated in the interview, of which data were analyzed based on phenomenological analysis methods. The types of non-face-to-face experiments experienced by students were complete non-face-to-face experiment, mixed face-to-face experiment, and fusion face-to-face experiment. Students were completely isolated in time and space in complete non-face-to-face experiment. In biweekly mixed face-to-face experiment, isolation was halved. In fusion face-to-face experiment, isolation was removed. Non-face-to-face interactions can be characterized by restrictions on simultaneous activities, on rapport formation, and on observation opportunities. Based on these results, three implications were derived: First, it is necessary to allow students to manage time and space constraints on their own in non-face-to-face experiments. Second, support is needed to solve the difficulty of forming rapport, which is a characteristic of non-face-to-face interaction. Third, an opportunity to observe the interaction between other students and professors should be provided.

비접촉 화학작용제 검출기의 MCT 광검출기를 위한 적분기 기반의 리드아웃 회로 구현 (Realization of Readout Circuit Through Integrator to Average MCT Photodetector Signals of Noncontact Chemical Agent Detector)

  • 박재현
    • 센서학회지
    • /
    • 제31권2호
    • /
    • pp.115-119
    • /
    • 2022
  • A readout circuit for a mercury-cadmium-telluride (MCT)-amplified mid-wave infrared (IR) photodetector was realized and applied to noncontact chemical agent detectors based on a quantum cascade laser (QCL). The QCL emitted 250 times for each wavelength in 0.2-㎛ steps from 8 to 12 ㎛ with a frequency of 100 kHz and duty ratio of 10%. Because of the nonconstant QCL emission power during on-duty, averaging the photodetector signals is essential. Averaging can be performed in digital back-end processing through a high-speed analog-to-digital converter (ADC) or in analog front-end processing through an integrator circuit. In addition, it should be considered that the 250 IR data points should be completely transferred to a PC during each wavelength tuning period of the QCL. To average and minimize the IR data, we designed a readout circuit using the analog front-end processing method. The proposed readout circuit consisted of a switched-capacitor integrator, voltage level shifter, relatively low-speed analog-to-digital converter, and micro-control unit. We confirmed that the MCT photodetector signal according to the QCL source can be accurately read and transferred to the PC without omissions.

GQD layers for Energy-Down-shift layer on silicon solar cells by kinetic spraying method

  • 이경동;박명진;김도연;김수민;강병준;김성탁;김현호;이해석;강윤묵;윤석구;홍병희;김동환
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.422.1-422.1
    • /
    • 2016
  • Graphene quantum dots (GQDs), a new kind of carbon-based photo luminescent nanomaterial from chemically modified graphene oxide (CMGO) or chemically modified graphene (CMG), has attracted extensive research attention in the last few years due to its outstanding chemical, optical and electrical properties. To further extended its potential applications as optoelectronic devices, solar cells, bio and bio-sensors and so on, intensive research efforts have been devoted to the CMG. However, the CMG, a suspension of aqueous, have problematic since they are prone to agglomeration after drying a solvent. In this study, we synthesized the GQDs from graphite and deposited on silicon substrate by kinetic spray. The photo luminescent properties of deposited GQD films were analyzed and compared with initial GQDs suspension. In addition, its carbon properties were investigated with GQDs solution properties. The properties of deposited GQD films by kinetic spray were similar to that of the GQDs suspension in water. We could provide a pathway for silicon-based silicon based device applications. Finally, the well-adjusted GQD films with photo luminescence effects will show Energy-Down-Shift layer effects on silicon solar cells. The GQD layers deposited at nozzle scan speeds of 40, 30, 20, and 10 mm/s were evaluated after they were used to fabricate crystalline-silicon solar cells; the results indicate that GQDs play an important role in increasing the optical absorptivity of the cells. The short-circuit current density (Jsc) was enhanced by about 2.94 % (0.9 mA/cm2) at 30 mm/s. Compared to a reference device without a GQD energy-down-shift layer, the PCE of p-type silicon solar cells was improved by 2.7% (0.4 percentage points).

  • PDF

심자도용 접선성분자장 측정방식 스퀴드 센서열 설계 (Design of a SQUID Sensor Array Measuring the Tangential Field Components in Magnetocardiogram)

  • 김기웅;이용호;권혁찬;김진목;김인선;박용기;이규원
    • Progress in Superconductivity
    • /
    • 제6권1호
    • /
    • pp.56-63
    • /
    • 2004
  • We consider design factors for a SQUID sensor array to construct a 52-channel magnetocardiogram (MCG) system that can be used to measure tangential components of the cardiac magnetic fields. Nowadays, full-size multichannel MCG systems, which cover the whole signal area of a heart, are developed to improve the clinical analysis with high accuracy and to provide patients with comfort in the course of measurement. To design the full-size MCG system, we have to make a compromise between cost and performance. The cost is involved with the number of sensors, the number of the electronics, the size of a cooling dewar, the consumption of refrigerants for maintenance, and etc. The performance is the capability of covering the whole heart volume at once and of localizing current sources with a small error. In this study, we design the cost-effective arrangement of sensors for MCG by considering an adequate sensor interval and the confidence region of a tolerable localization error, which covers the heart. In order to fit the detector array on the cylindrical dewar economically, we removed the detectors that were located at the corners of the array square. Through simulations using the confidence region method, we verified that our design of the detector array was good enough to obtain whole information from the heart at a time. A result of the simulation also suggested that tangential-component MCG measurement could localize deeper current dipoles than normal-component MCG measurement with the same confidence volume; therefore, we conclude that measurement of the tangential component is more suitable to an MCG system than measurement of the normal component.

  • PDF