• 제목/요약/키워드: Quantitative ultrasound

검색결과 134건 처리시간 0.037초

초음파 탄성 영상법 (Ultrasound Elasticity Imaging Methods)

  • 정목근;권성재
    • The Journal of the Acoustical Society of Korea
    • /
    • 제29권1E호
    • /
    • pp.1-10
    • /
    • 2010
  • The difference in echogenicity between cancerous and normal tissues is not quite distinguishable in ultrasound B-mode imaging. However, tumor or cancer in breast or prostate tends to be stiffer than the surrounding normal tissue. Thus, imaging the stiffness contrast between the two different tissue types is helpful for quantitative diagnosis, and such a method of imaging the elasticity of human tissue is collectively referred to as ultrasound elasticity imaging. Recently, elasticity imaging has established itself as an effective diagnostic modality in addition to ultrasound B-mode imaging. The purpose of this paper is to present various elasticity imaging methods that have been reported up to now and to describe their principles of operation and characteristics.

The medium coupling effect on propagation of guided waves in engineering structures and human bone phantoms

  • Chen, Jiangang;Su, Zhongqing;Cheng, Li
    • Coupled systems mechanics
    • /
    • 제1권4호
    • /
    • pp.297-309
    • /
    • 2012
  • As a result of the medium coupling, propagation characteristics of ultrasonic waves guided by a multi-phase medium can be different from those in a homogeneous system. This phenomenon becomes prominent for a medium consisting of phases with considerably distinct material and physical properties (e.g., submerged structures or human bones covered with soft tissues). In this study, the coupling effect arising from both fluid and soft tissues on wave propagation in engineering structures and human bone phantoms, respectively, was explored and calibrated quantitatively, with a purpose of enhancing the precision of ultrasonic-wave-based non-destructive evaluation (NDE) and clinical quantitative ultrasound (QUS). Calibration results were used to rectify conventional NDE during evaluation of corrosion in a submerged aluminium plate, and QUS during prediction of simulated healing status of a mimicked bone fracture. The results demonstrated that with the coupling effect being appropriately taken into account, the precision of NDE and QUS could be improved.

초음파를 이용한 조직구조 특성변수의 측정 (Parameter Estimation of Tissue Structure Characteristics in Ultrasound Measurement)

  • 곽철은;김종원
    • 대한의용생체공학회:의공학회지
    • /
    • 제7권1호
    • /
    • pp.41-44
    • /
    • 1986
  • The objective of tissue characterization is to provide quantitative information about the physical state of tissue interrogated by an ultrasound beam. In the computer simulation, it was found that the echoes were composed of the interferences of the ultrasonic waves reflected from both sides of the thin object, and could be separated by the spectral correlation method. Also, the phantom study demonstrates that thickness of the thin acryl layer beyond the resolution of common ultrasonic imaging systems can be measured- using this method.

  • PDF

대퇴부 모델에서의 초음파 압력분포에 관한 유한요소 해석 (Finite Element Analysis of Pressure Distribution by Ultrasound in Human Thigh Model)

  • 최호선
    • 정보학연구
    • /
    • 제8권1호
    • /
    • pp.43-50
    • /
    • 2005
  • Quantitative analysis for distribution of penetrating ultrasound in vivo is very important to determine the treatment region and method. In this paper, we constructed a simplified 2-D femoral region model that consists of skin-fat-muscle-bone layered system, and simulated the pressure distribution in the model in case of applying ultrasound using Finite Element Method(FEM). The ultrasound used in the simulation was assumed to be pulse wave and the pressure distribution was analyzed during only one period of pulse wave. In order to find the penetration depth, amplitude of pressure and sphere that ultrasound reaches in the model, we performed the simulation with varying the applied frequency, transducer size and amplitude of transducer's output. The result showed that applied frequency is inversely proportional to the penetration depth and amplitude of pressure but the amplitude of transducer's output is proportional to the amplitude of pressure in the model. Also, the sphere that ultrasound reaches was widened and the amplitude of pressure became larger as the transducer size became larger. This results were similar to that obtained from the previous model consisting of fat-muscle-bone layered system, but we observed that the pressure of ultrasound is decreased due to the decrements of pressure by the absorption coefficient of skin and the interference that depends on the reflection of ultrasound caused by the difference of acoustic impedance of skin and fat. Finally, we can infer that the model proposed in this study is closer to the realistic model than the previous ones. It shows that the results obtained from this study can be useful in designing the ultrasound treatment instrument or in setting up the treatment plan.

  • PDF

Side lobe free medical ultrasonic imaging with application to assessing side lobe suppression filter

  • Jeong, Mok Kun;Kwon, Sung Jae
    • Biomedical Engineering Letters
    • /
    • 제8권4호
    • /
    • pp.355-364
    • /
    • 2018
  • When focusing using an ultrasonic transducer array, a main lobe is formed in the focal region of an ultrasound field, but side lobes also arise around the focal region due to the leakage. Since the side lobes cannot be completely eliminated in the focusing process, they are responsible for subsequent ultrasound image quality degradation. To improve ultrasound image quality, a signal processing strategy to reduce side lobes is definitely in demand. To this end, quantitative determination of main and side lobes is necessary. We propose a theoretically and actually error-free method of exactly discriminating and separately computing the main lobe and side lobe parts in ultrasound image by computer simulation. We refer to images constructed using the main and side lobe signals as the main and side lobe images, respectively. Since the main and side lobe images exactly represent their main and side lobe components, respectively, they can be used to evaluate ultrasound image quality. Defining the average brightness of the main and side lobe images, the conventional to side lobe image ratio, and the main to side lobe image ratio as image quality metrics, we can evaluate image characteristics in speckle images. The proposed method is also applied in assessing the performance of side lobe suppression filtering. We show that the proposed method may greatly aid in the evaluation of medical ultrasonic images using computer simulations, albeit lacking the use of actual experimental data.

폐경 후 여성에서 골다공증의 조기검진도구로서 골초음파의 유용성 (Quantitative Ultrasound for Osteoporosis Screening in Postmenopausal Women)

  • 신희영;정은경;이정애;최진수;신민호
    • Journal of Preventive Medicine and Public Health
    • /
    • 제34권4호
    • /
    • pp.408-416
    • /
    • 2001
  • Objectives : To evaluate the diagnostic value of quantitative ultrasound (QUS) in the prediction of osteoporosis as defined by dual energy x-ray absorptiometry (DEXA) in postmenopausal women. Methods : Questionnaires and height and weight measurements were used in the investigation of 176 postmenopausal women. QUS measurements were taken on the right calcaneus while bone mineral density (BMD) measurements of the lumbar spine and femoral neck were made with DEXA. The areas under the curves (AUC) of the speed of sound (SOS) for osteoporosis in the lumbar spine and femoral neck were obtained through receiver operating characteristic (ROC) analysis and evaluated. A comparison was made, for osteoporosis in the lumbar spine and femoral neck, between the AUCs of the logistic model with clinical risk factors and SOS. Results : Pearson's correlation coefficients of SOS and lumbar spine BMD, and of SOS and femoral neck BMD were 0.26 and 0.37. The AUC for the logistic model in its discrimination for lumbar spine osteoporosis was 0.764, and for SOS 0.605. The AUCs for the logistic model in its discrimination for femoral neck osteoporosis and for SOS were 0.890 and 0.892, respectively. Conclusions : These results suggest that the diagnostic value of QUS as a screening tool for osteoporosis is moderate for the femoral neck, but merely low for the lumbar spine and that the predictability provided by SOS is no better than that by the sole use of clinical risk factors in postmenopausal women.

  • PDF

Correlation of Contrast-Enhanced Ultrasonographic Features with Microvessel Density in Papillary Thyroid Carcinomas

  • Zhou, Qi;Jiang, Jue;Shang, Xu;Zhang, Hong-Li;Ma, Wen-Qi;Xu, Yong-Bo;Wang, Hua;Li, Miao
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권17호
    • /
    • pp.7449-7452
    • /
    • 2014
  • Background: The purpose of this study was to investigate the correlation of contrast-enhanced ultrasonographic (CEUS) features with microvessel density (MVD) in papillary thyroid carcinomas (PTCs). Materials and Methods: Contrast-enhanced ultrasonography (CEUS) was performed in 62 patients (17 men and 45 women) with PTC. Tomtec software was applied to analyze the time intensity curve of CEUS. Immunohistochemistry was performed to evaluate the level of MVD in papillary thyroid carcinoma. Then the relationship between quantitative feature and the level of MVD was analyzed using SPSS 16.0 software. Results: The mean peak intensity of PTC tissues was lower than that of peripheral thyroid parenchyma ($61.9{\pm}11.8%$ vs 100%, p<0.05). The MVDs of CD34 and CD31 antibodies staining were $38.0{\pm}6.1$ and $37.9{\pm}5.1$ respectively in 62 PTC samples. A significantly positive correlation was observed between peak intensity and MVD in PTC tissues ($P_{CD34}$<0.01, $r_{CD34}$=0.838, $P_{CD31}$<0.01, $r_{CD31}$=0.837). Conclusions: The peak intensity in CEUS could reflect the MVD in PTC tissues. Therefore, quantification of CEUS seems to be helpful for assessment of MVD in PTC tissues.

Ultrasound Attenuation in the Assessment of Bone Mineral Density and Elastic Modulus of Human Trabecular Bone

  • Han, S.M.;Kim, M.S.
    • 대한의용생체공학회:의공학회지
    • /
    • 제19권2호
    • /
    • pp.171-176
    • /
    • 1998
  • 본 연구에서는 뼈의 특성을 파악하는 초음파감쇠 파라미터를 재평가하였다. 초음파 속도, 특정 주파수(0.5MHz)에서의 초음파감쇠 및 광역 밴드 초음파감쇠와 같은 초음파 파라미터들을 해면골 입방체 시편의 세 직교방향(전/후, 내/외, 상/하)에서 측정하였다. 그리고 컴퓨터 영상장치를 사용하여 골밀도를 측정했으며, 골 시편의 무게와 부피를 이용하여 외형밀도도 함께얻었다. 이와같이 구해진 외형밀도와 초음파 속도로부터 초음파 탄성영률을 계산하였다. 주파수 0.5MHz에서의 초음파감쇠와 광역밴드감쇠는 골밀도 및 세 직교방향의 초음파 영률과 서로 관련시켜 연관성을 조사하였다. 그 결과 특정 주파수 초음파감쇠가 골밀도 및 탄성영률을 평가하는 능력에 있어서 광역밴드 감쇠보다 우수함을 알 수 있었다. 따라서 광역밴드 초음파감쇠를 측정하여 골의 상태를 평가하는 형행 초음파 진단 기법이 재검토 되어야 하며 본 연구에서 증명된 특정주파수(0.5MHz) 초음파감쇠를 이용하여 골 다공증 진단 예측율을 향상시킬 수 있다.

  • PDF

근근막 발통점의 활성도에 따른 초음파 영상구조 및 전기생리학적 특성 (Ultrasound Imaging and Electrophysiological Characteristic According to Activity Levels of Myofascial Trigger Point)

  • 김현진;김수현;박영현;오석;최지호;김태열
    • 대한임상전기생리학회지
    • /
    • 제8권1호
    • /
    • pp.23-29
    • /
    • 2010
  • Purpose : This study is to offer clinical primary data that examines the change of imaging structure and the quantitative evaluation of muscle activity on myofascial trigger points. This study examines neuromuscular physiological characteristic by comparing the differences in physical findings, pressure pain threshold, imaging, and electrophysiological characteristics in latent and active myofascial trigger points muscle and normal muscle through the following experimental procedures. Methods : The participants for the study were thirty-three adults in their twenties. We divided three groups into normal, latent and active myofascial trigger points groups by physical findings. We analyzed the results of measured pressure pain, threshold for pain, ultrasound imaging perform for structure characteristic of muscle, surface EMG according to type of muscle contraction for function of muscle contraction. Results : Significant differences were indicated in pressure pain threshold (p<0.05). Significant differences were discovered in the ultrasound imaging analysis. There were increases in muscle Echogenicity white area index (p<0.001). There were significant differences that decrease in %MVIC (p<0.05), increase in MDF (p<0.05). Conclusion : From these results, active rnyotascial trigger points muscle showed quality deterioration on ultrasound imaging and decreased function of muscle contraction, increased motor unit action potential of II type fiber, and electrophysiologically. Imaging structure and neuromuscular physiological characteristic can be diagnostic and quantitative analytical techniques for myofascial pain syndrome and a primary factor that reflected in physical therapy intervention.

MRI Features for Prediction Malignant Intra-Mammary Lymph Nodes: Correlations with Mammography and Ultrasound

  • Kim, Meejung;Kang, Bong Joo;Park, Ga Eun
    • Investigative Magnetic Resonance Imaging
    • /
    • 제26권2호
    • /
    • pp.135-149
    • /
    • 2022
  • Purpose: To assess clinically significant imaging findings of malignant intramammary lymph nodes (IMLNs) in breast cancer patients and to evaluate their diagnostic performance in predicting malignant IMLN. Materials and Methods: A total of 110 cases with IMLN of BI-RADS category 3 or more, not typical benign IMLN, in MR of breast cancer patients between January 2016 and January 2021 were retrospectively reviewed. After excluding 33 cases, 77 cases were finally included. Among them, 58 and 19 were confirmed as benign and malignant, respectively. Qualitative and quantitative MR imaging features of the IMLN were retrospectively analyzed. Sizes and final assessment categories of IMLN on MRI, mammography, and ultrasound were reviewed. Diagnostic performances of imaging features on MRI, mammography, and ultrasound were then evaluated. Results: For qualitative MR features, shape, margin, and preserved central hilum were significantly different between benign and malignant groups (P < 0.05). For quantitative MR features, long diameter over 6 mm, short diameter over 4 mm, and cortical thickening over 3 mm showed high sensitivities in predicting malignant IMLNs (89.5%, 94.7%, and 100%, respectively). Size exceeding 1 cm showed high specificity and accuracy in predicting malignant IMLN on MR, mammography, and ultrasound (91.4% and 80.5%; 96.6% and 79.25; 98.3% and 80.5%, respectively). Conclusion: Various MR imaging features and size can be helpful for predicting malignant IMLN in breast cancer patients.