• Title/Summary/Keyword: Quantification I method

Search Result 166, Processing Time 0.032 seconds

Establishment of DeCART/MIG stochastic sampling code system and Application to UAM and BEAVRS benchmarks

  • Ho Jin Park;Jin Young Cho
    • Nuclear Engineering and Technology
    • /
    • v.55 no.4
    • /
    • pp.1563-1570
    • /
    • 2023
  • In this study, a DeCART/MIG uncertainty quantification (UQ) analysis code system with a multicorrelated cross section stochastic sampling (S.S.) module was established and verified through the UAM (Uncertainty Analysis in Modeling) and the BEAVRS (Benchmark for Evaluation And Validation of Reactor Simulations) benchmark calculations. For the S.S. calculations, a sample of 500 DeCART multigroup cross section sets for two major actinides, i.e., 235U and 238U, were generated by the MIG code and covariance data from the ENDF/B-VII.1 evaluated nuclear data library. In the three pin problems (i.e. TMI-1, PB2, and Koz-6) from the UAM benchmark, the uncertainties in kinf by the DeCART/MIG S.S. calculations agreed very well with the sensitivity and uncertainty (S/U) perturbation results by DeCART/MUSAD and the S/U direct subtraction (S/U-DS) results by the DeCART/MIG. From these results, it was concluded that the multi-group cross section sampling module of the MIG code works correctly and accurately. In the BEAVRS whole benchmark problems, the uncertainties in the control rod bank worth, isothermal temperature coefficient, power distribution, and critical boron concentration due to cross section uncertainties were calculated by the DeCART/MIG code system. Overall, the uncertainties in these design parameters were less than the general design review criteria of a typical pressurized water reactor start-up case. This newly-developed DeCART/MIG UQ analysis code system by the S.S. method can be widely utilized as uncertainty analysis and margin estimation tools for developing and designing new advanced nuclear reactors.

Aluminum in rocks: Optimized microwave-assisted acid digestion and UV-Vis spectrophotometric measurement

  • Nguyen Thanh-Nho;Thai Huynh-Thuc;Le-Thi Anh-Dao;Do Minh-Huy;Le-Thi Huynh-Mai;Le Quang-Huy;Nguyen-Thi Kim-Sinh;Nguyen Cong-Hau
    • Analytical Science and Technology
    • /
    • v.36 no.5
    • /
    • pp.216-223
    • /
    • 2023
  • Aluminium (Al) is one of the major elements in rocks and its concentration can be varied, depending on different rock types as well as sources. The present study aimed to propose an analytical method based on the UV-Vis as a cheap, simple, and common instrument equipped in most laboratories for Al quantification in rocks after the microwave assisted acid digestion. The aluminone and 8-hydroxyquinoline were investigated for the colorimetric assay. The results show that the 8-hydroxyquinoline reagent was more favorable in terms of the minimized affects of the potential interferences present in the digested solutions, i.e., Fe3+, Si4+ and F-. The calibration curve was constructed from 0.10 mg/L to 3.00 mg/L with the goodness of linearity (R2 = 0.9996). The limits of detection and quantification (LOD and LOQ) were estimated, i.e., 0.029 mg/L and 0.087 mg/L, respectively. The 8-hydroxyquinoline was applied to real rock samples, demonstrating favorable precision (RSD = 0.34 %-1.8 %) and no remarkable differences were found compared to the inductively coupled plasma-mass spectrometry (ICP-MS) as a reference measurement approach.

Simultaneous Determination of Hesperidin and Glycyrrhizin in Pyungwi-san by HPLC/DAD (HPLC-DAD를 이용한 평위산 중의 Hesperidin 및 Glycyrrhizin의 동시분석법 확립)

  • Lee, Mi-Kyeong;Choe, Ok-Gyeong;Park, Jin-Ho;Cho, Jung-Hee;Kim, Do-Hoon;Baek, Ju-Hyun;Kim, Hyo-Jin;Lee, Ki-Yong;Kim, Sang-Du;Kim, Young-Choong;Sung, Sang-Hyun
    • Korean Journal of Pharmacognosy
    • /
    • v.39 no.3
    • /
    • pp.199-202
    • /
    • 2008
  • A high performance liquid chromatographic (HPLC) method for the simultaneous determination of hesperidin and glycyrrhizin was established for the quality control of traditional herbal medicinal preparation, Pyungwi-san (PWS). Separation and quantification were successfully achieved with a Waters XTerra RP18 column ($5{\mu}m$, 4.6 mm I.D. ${\times}$ 150 mm) by gradient elution of a mixture of acetonitrile and water containing 0.03% phosphoric acid (pH 2.03) at a flow rate of 1.0 ml/min. The diode-array UV/vis detector (DAD) was used for the detection and the wavelength for quantification was set at 230 nm. The presence of hesperidin and glycyrrhizin in this extract was ascertained by retention time, spiking with each authentic standard and UV spectrum. All four compounds showed good linearity $(r^2>0.995)$ in a relatively wide concentration ranges. The R.S.D. for intra-day and inter-day precision was less than 7.0% and the limits of detection (LOD) were less than 60 ng. The mean recovery of each compound was 99.0-105.6% with R.S.D. values less than 4.0%. This method was successfully applied to the determination of contents of hesperidin and glycyrrhizin in three commercial products of PWS. These results suggest that the developed HPLC method is simple, effective and could be readily utilized as a quality control method for commercial PWS products.

A MOS Assignment Model to Enlisted Recruits Using AHP and Goal Programming (AHP기법과 목표계획법을 이용한 신병 군사특기 분류 모형)

  • 민계료;김해식
    • Journal of the military operations research society of Korea
    • /
    • v.25 no.1
    • /
    • pp.142-159
    • /
    • 1999
  • To assign the soldiers in the adequate positions I military is almost as important as managing officers because they compose the main part of military structure and equipment operators. The current Military Occupational Specialty(MOS) assignment system lacks the capability to optimize the use of recruit's potential. We suggest an MOS assignment method for enlisted recruits using the Analytic Hierarchy Process(AHP) method, this method systematically provides a method of calculation of composite relative weights of decision elements to be considered during MOS assignment and a method of quantification for personal quality of new recruits. The quantified value of personal quality, Mission Performance Capability(MPC), in this study means the mission performance capability when a personnel is assigned to a certain MOS. This paper develops a multiple objectives MOS assignment model for enlisted recruits. It uses MPC of personnels, calculated with AHP method and consensus method, as parameters. The goal constraints are assurance of filling requirement, minimization of the number of unassigned personnel to MOS, capability satisfaction of education facility and support facility, assurance of desired MPC value level for MOS assignment, and maximization of total MPC. The objective function is to terminalization of the negative or positive deviation for the above goal constraints.

  • PDF

Determining Potassium Bromate in the Inhalable Aerosol Fraction in Workplace Air with Ion Chromatography

  • Kowalska, Joanna;Lis, Monika;Biesaga, Magdalena
    • Safety and Health at Work
    • /
    • v.12 no.2
    • /
    • pp.209-216
    • /
    • 2021
  • Background: The article presents the results of studies performed in order to develop a new method of airborne potassium bromate(V) determination at workplaces. Methods: The method is based on a collection of the inhalable fraction of potassium bromate(V) using the IOM Sampler, then extraction of bromates with deionized water and chromatographic analysis of the obtained solution. The analysis was performed using ion chromatography with conductometric detection. The tests were performed on a Dionex IonPac®AS22 analytic column (250 × 4 mm, 6 ㎛) with AG22 precolumn (50 × 4 mm 11 ㎛). Results: The method provides for potassium bromate(V) determination within the concentration range of 0.043 ÷ 0.88 mg/m3 for an air sample of 0.72 m3 in volume, i.e., 0.1-2 times the exposure limit value as proposed in Poland. The method was validated in accordance with PN-EN 482. The obtained validation data are as follows: measuring range: 3.1-63.4 ㎍/mL, limit of detection (LOD) = 0.018 ㎍/mL and limit of quantification (LOQ) = 0.053 ㎍/mL. The developed method has been tested in the work environment, on laboratory employees having contact with potassium bromate(V). Conclusion: The analytical method allowed the determination of the inhalable fraction of airborne potassium bromate(V) at workplaces and can be used to assess occupational exposure.

Analysis of Trace Levels of Lodinated Trihalomethanes in Water Using Headspace - GC/ECD (Headspace - GC/ECD를 이용한 수중의 미량 요오드계 트리할로메탄류 분석)

  • Son, Hee-Jong;Song, Mi-Jung;Kim, Kyung-A;Yoom, Hoon-Sik;Choi, Jin-Taek
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.1
    • /
    • pp.35-41
    • /
    • 2014
  • Trihalomethanes (THMs) are formed as a results of the reaction of residual chlorine, used as a disinfectant in drinking water, with the organic matter in raw water. Although chlorinated and brominated THMs are the most common disinfection byproducts (DBPs) reported, iodinated THMs (I-THMs) can be formed when iodide is present in raw water. I-THMs have been usually associated with several medicinal or pharmaceutical taste and odor problems and is a potential health concern since they have been reported to be more toxic than their brominated and chlorinated analogs. Currently, there is no published standard analytical method for I-THMs in water. An automated headspace-gas chromatography/electron capture detector (GC/ECD) technique was developed for routine analysis of 10 THMs including 6 I-THMs in water samples. The optimization of the method is discussed. The limits of detection (LOD) and limits of quantification (LOQ) range from 12 ng/L to 56 ng/L and from 38 ng/L to 178 ng/L for 10 THMs, respectively. Matrix effects in river water, sea water and wastewater treatment plant (WWTP) final effluent water were investigated and it was shown that the method is suitable for the analysis of trace levels of I-THMs, in a wide range of waters. The method developed in the present study has the advantage of being rapid, simple and sensitive.

Main Region and Color Extraction of Face for Heart Disease Diagnosis (심장 질환 진단을 위한 얼굴 주요 영역 및 색상 추출)

  • Cho Dong-Uk
    • The KIPS Transactions:PartB
    • /
    • v.13B no.3 s.106
    • /
    • pp.215-222
    • /
    • 2006
  • People health improvement is becoming new subject through the combining with the oriental medicine diagnosis theory and IT technology. To do this, firstly, it needs sicked data that supply the visualization, objectification and quantification method. Especially, if an ocular inspection can be more objective and visual expression in oriental medicine, it seems to offer the biggest opportunity in diagnosis field. In this study, I propose a diagnosis to check the symptoms of heart diagnosis. Our research aim is on the visualization of diagnosis using image processing system which it can be actual analysis about the symptom of heart. To catch up this study, through the color support assistance by face image processing, I devide the face area and analyze the face form and also extract face characteristic point in heart disease diagnosis using oriental medicine based on an ocular inspection method. I would like to prove the usefulness of the method that proposed by an experiment.

Study on the histomorphometry of guided bone regeneration using automated image analysis system (자동 영상분석 계기를 이용한 골 유도재생능력의 분석에 관한 조직계측학적 연구)

  • Kim, T.I.;Ku, Y.;Rhyu, I.C.;Chung, C.P.;Han, S.B.;Choi, S.M.;Son, S.H.
    • Journal of Periodontal and Implant Science
    • /
    • v.26 no.3
    • /
    • pp.771-778
    • /
    • 1996
  • The assessment of alveolar bone changes on dental radiographs to indicate progression of periodontal diseases or healing response to therapy is routine procedure. However, the diagnostic accuracy in detecting small alveolar bone changes is very limited. Recently, guided bone regeneration therapy is popular, but the quantification of new bone is somewhat difficult with conventional evaluation method. To quantificate the amount of new bone, various evaluating methods have been introduced including histomorphometry, radiomorphometry, biochemical analysis, X-ray probe microanalysis, scanning electron microscope backscatter method. In this study, guided bone regeneration using resorbable membrane with & without PDGF-BB is quatificated through histomorphmetry to evaluate the efficacy of histomorphometric analysis. 4 beagle dogs and 8 Sprague-Dawley rats were selected as experimental animals. In beagle dog experiment, $4{\times}4mm$ Class II defects were created in maxillary both second premolars, and biodegradable membrane containing PDGF-BB(experimental group) were covered over one defect, and same membrane without PDGF-BB(control group) were covered over the other defect. At 2 weeks, 5 weeks after surgery, each beagle dogs were sacrificed, and the tissues were treated by undecalcified fixation. In Sprague-Dawley rat experiment, 5mm round defect were created in temporal bone, the same membranes were covered on the defects. At 1 week, 2 weeks after surgery, each rats were sacrificed, and undecalcified fixation were taken. After grinding tissue specimen, we analyse them histomorphometrically using image analysis system. In beagle dog 2 weeks specimens, new bone formation area were $0.03123mm^2$ in experimental group,and $0.03012mm^2$ in control group. At 5 weeks specimens, $0.15324mm^2$ in experimental group, and $0.09123mm^2$ in control group. In Sprague-Dawley rat specimens, new bone fomation area were $0.20448mm^2$ in 1 week experimental group, $0.03604mm^2$ in 1 week control group. At 2 weeks specimens, $0.46349mm^2$ in experimental group, $0.17741mm^2$ in control group. The results indicated that histomorphometric analysis of new bone formation using image analysis system is very effective quantification method to evaluate the efficacy of treatment modalities.

  • PDF

Extracting Method of Kansei Design Rules Based on Rough Set Analysis

  • Nishino, Tatsuo;Nagamachi, Mitsuo
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2002.05a
    • /
    • pp.201-204
    • /
    • 2002
  • Kansei design knowledge acquisition stage is a crucial stage in kansei designing process and kansei engineering (KE) methodology. In kansei engineering methodology, it is essential to extract design knowledge or rules on relationships between customer's kansei and product design element. We attempt to construct a more powerful melted for extracting the design rules from kansei expremental data. We constucted a kansei experiment concerning color kansei evaluation, and analyzed the sane data by both conventional quantification theory type I and rough set theory. Finally, we compared the effectiveness of both methods for extracting rules and examined the extensions of rough set theory in kansei engineering.

  • PDF

A Review on Recent Study of Acoustic Analysis (음성분석의 최근 연구 동향에 관한 문헌적 고찰)

  • Park, Chan-Kyu;Park, Young-Jae;Park, Young-Bae
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.13 no.1
    • /
    • pp.65-71
    • /
    • 2009
  • Objective : To review studies about acoustic analysis and to study its medical application. Method : We investigate the research results through internet search engines, such as Pubmed. Conclusions : I would like to conclude that there should be continued study, along with the objectification and quantification of diagnosis and application of acoustic analysis in the wide variety of oriental medicine.

  • PDF