• 제목/요약/키워드: Quality control parameters

검색결과 1,044건 처리시간 0.023초

단방향 누적점수관리도의 설계 (A Design of One-Sided Cumulative Scored Control Chart)

  • 최인수;이윤동
    • 품질경영학회지
    • /
    • 제26권3호
    • /
    • pp.31-45
    • /
    • 1998
  • This paper proposes a method of designing one-sided cumulative scored control charts to control the process mean with a normally distributed quality characteristic. The average run length(ARL) is obtained from the average sample number of sequential probability ratio test(SPRT) on trinomial distribution. Using the analogy between cumulative scored control chart and SPRT for trinomial observations, a procedure is presented to determine three control chart parameters; lower and u, pp.r scoring boundaries and action limit. The parameters are determined by minimizing the ARL when the process is out of control with prespecified ARL when the process is in control.

  • PDF

Fault Detection, Diagnosis, and Optimization of Wafer Manufacturing Processes utilizing Knowledge Creation

  • Bae Hyeon;Kim Sung-Shin;Woo Kwang-Bang;May Gary S.;Lee Duk-Kwon
    • International Journal of Control, Automation, and Systems
    • /
    • 제4권3호
    • /
    • pp.372-381
    • /
    • 2006
  • The purpose of this study was to develop a process management system to manage ingot fabrication and improve ingot quality. The ingot is the first manufactured material of wafers. Trace parameters were collected on-line but measurement parameters were measured by sampling inspection. The quality parameters were applied to evaluate the quality. Therefore, preprocessing was necessary to extract useful information from the quality data. First, statistical methods were used for data generation. Then, modeling was performed, using the generated data, to improve the performance of the models. The function of the models is to predict the quality corresponding to control parameters. Secondly, rule extraction was performed to find the relation between the production quality and control conditions. The extracted rules can give important information concerning how to handle the process correctly. The dynamic polynomial neural network (DPNN) and decision tree were applied for data modeling and rule extraction, respectively, from the ingot fabrication data.

Estimation of Qualities and Inference of Operating Conditions for Optimization of Wafer Fabrication Using Artificial Intelligent Methods

  • Bae, Hyeon;Kim, Sung-Shin;Woo, Kwang-Bang
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1101-1106
    • /
    • 2005
  • The purpose of this study was to develop a process management system to manage ingot fabrication and the quality of the ingot. The ingot is the first manufactured material of wafers. Operating data (trace parameters) were collected on-line but quality data (measurement parameters) were measured by sampling inspection. The quality parameters were applied to evaluate the quality. Thus, preprocessing was necessary to extract useful information from the quality data. First, statistical methods were employed for data generation, and then modeling was accomplished, using the generated data, to improve the performance of the models. The function of the models is to predict the quality corresponding to the control parameters. The dynamic polynomial neural network (DPNN) was used for data modeling that used the ingot fabrication data.

  • PDF

수질제어를 통한 관 내부 부식방지 기술의 정수처리공정 적용방안 (Approaches to Internal Corrosion Control Technologies by Controlling Water Quality in Water Treatment Systems)

  • 서대근;왕창근
    • 상하수도학회지
    • /
    • 제20권4호
    • /
    • pp.509-518
    • /
    • 2006
  • Although final water of domestic water treatment plants almost contains highly corrosive characteristics, the countermeasures for eliminating internal corrosion of pipeline system have not been conducted yet by controlling water quality in plants. The technologies of internal corrosion control are to control water quality parameters(pH, Alkalinity, and Calcium Hardness etc.) and to use corrosion inhibitor. Under the conditions of domestic water treatment, first of all, the technologies of adjusting water quality parameters has to be considered. Otherwise, The technology of using corrosion inhibitor is favorably thought to be applied with the technology of adjusting water quality parameters in accordance with the result of availability for water treatment process. Since the technology of adjusting water quality parameter influences on other water treatment processes, the guideline of water quality management to be apt for water quality characteristic is required to be estabilished. While the selection of proper chemicals and technologies is dependent upon the raw water characteristics and water treatment process, typically, the technology of $Ca(OH)_2$ & $CO_2$ additions is considered more effective than other technologies in order to adjust pH and Alkalinity, increase $Ca^{2+}$ and form $CaCO_3$ film

Stochastic Optimal Control and Network Co-Design for Networked Control Systems

  • Ji, Kun;Kim, Won-Jong
    • International Journal of Control, Automation, and Systems
    • /
    • 제5권5호
    • /
    • pp.515-525
    • /
    • 2007
  • In this paper, we develop a co-design methodology of stochastic optimal controllers and network parameters that optimizes the overall quality of control (QoC) in networked control systems (NCSs). A new dynamic model for NCSs is provided. The relationship between the system stability and performance and the sampling frequency is investigated, and the analysis of co-design of control and network parameters is presented to determine the working range of the sampling frequency in an NCS. This optimal sampling frequency range is derived based on the system dynamics and the network characteristics such as data rate, time-delay upper bound, data-packet size, and device processing time. With the optimal sampling frequency, stochastic optimal controllers are designed to improve the overall QoC in an NCS. This co-design methodology is a useful rule of thumb to choose the network and control parameters for NCS implementation. The feasibility and effectiveness of this co-design methodology is verified experimentally by our NCS test bed, a ball magnetic-levitation (maglev) system.

토모테라피에서 통계적공정관리를 이용한 EBT 필름 기반의 선량품질보증의 치료계획 가이드라인 (Treatment Planning Guideline of EBT Film-based Delivery Quality Assurance Using Statistical Process Control in Helical Tomotherapy)

  • 장경환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권5호
    • /
    • pp.439-448
    • /
    • 2022
  • The purpose of this study was to analyze the results from statistical process control (SPC) to recommend upper and lower control limits for planning parameters based on delivery quality assurance (DQA) results and establish our institutional guidelines regarding planning parameters for helical tomotherapy (HT). A total of 53 brain, 41 head and neck (H & N), and 51 pelvis cases who had passing or failing DQA measurements were selected. The absolute point dose difference (DD) and the global gamma passing rate (GPR) for all patients were analyzed. Control charts were used to evaluate upper and lower control limits (UCL and LCL) for all assessed treatment planning parameters. Treatment planning parameters were analyzed to provide its range for DQA pass cases. We confirmed that the probability of DQA failure was higher when the proportion of leaf open time (LOT) below 100 ms was greater than 30%. LOT and gantry period (GP) were significant predictor for DQA failure using the SPC method. We investigated the availability of the SPC statistic method to establish the local planning guideline based on DQA results for HT system. The guideline of each planning parameter in HT may assist in the prediction of DQA failure using the SPC statistic method in the future.

GPS 데이터 품질관리 프로그램의 개발 (Developement of GPS Data Quality Control Program)

  • 윤홍식;이동하;이영균;조재명
    • 한국측량학회지
    • /
    • 제24권1호
    • /
    • pp.9-18
    • /
    • 2006
  • 본 연구는 GPS 데이터 해석 시 정밀도를 높이고 현장에서 관측시간 내 GPS 측량의 적절성 및 재측 여부 등을 직접 결정할 수 있도록 GPS 데이터 품질관리 프로그램을 개발하는 것에 그 목적이 있다. 본 연구에서 개발된 GPS_QC 프로그램은 관측시간 내 위성의 기하학적 배치(DOP)와 다중경로 오차량, 전리층 지연량 및 사이클 슬립 등의 품질관리 인자(quality control parameters)를 RINEX 형식의 GPS 관측데이터로부터 직접 계산이 가능하도록 설계되었으며, 이러한 품질관리 인자는 시계열 형태와 그래프로 제공된다. GPS_QC 프로그램은 일반 사용자들이 다루기 어려웠던 기존의 복잡한 GPS 데이터 품질 확인을 간편하게 수행할 수 있도록 함으로써 실제 현장에서 잘못된 GPS 관측에 따른 재측여부 등을 직접 결정할 수 있게 함으로써 시간적 경제적 손실을 절감시키고, GPS 위치해석 시 정밀도를 높일 수 있을 것으로 판단된다.

Effect of aqueous Nigella sativa extract on the functional parameters of post-thaw human spermatozoa during vitrification

  • Nasiri, Zohreh;Ghorbani, Fatemeh;Seify, Mohammad;Sharbati, Aysan
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제49권2호
    • /
    • pp.110-116
    • /
    • 2022
  • Objective: Sperm vitrification leads to the production of reactive oxygen species (ROS) that can damage the functional parameters of sperm. The present study aimed to investigate the antioxidant effect of Nigella sativa extract on motility, plasma membrane function, mitochondrial membrane potential (MMP), DNA damage, and intracellular ROS production. Methods: A total of 20 sperm samples were used. Samples were divided into six experimental groups, including groups with aqueous extract from N. sativa seeds at concentrations of 1% to 6%, a cryopreserved control group, and a fresh control group. Results: Statistical analysis showed significantly higher total sperm motility at concentrations of 3% to 6% than in the vitrified semen control group. Additionally, progressive motility and all motion characteristics at all concentrations were significantly higher than in the vitrified semen control group. The presence of N. sativa seed extract also improved the quality of the sperm parameters assayed in all experimental groups (1%-6%; intracellular ROS production, DNA damage, MMP, and sperm membrane function) compared to the control group. Conclusion: Higher concentrations of N. sativa led to improvements in all sperm parameters and sperm quality. These findings indicate that N. sativa seed extract is effective for improving the quality of sperm after vitrification.

Effect of different short-term high ambient temperature on chicken meat quality and ultra-structure

  • Zhang, Minghao;Zhu, Lixian;Zhang, Yimin;Mao, Yanwei;Zhang, Mingyue;Dong, Pengcheng;Niu, Lebao;Luo, Xin;Liang, Rongrong
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제32권5호
    • /
    • pp.701-710
    • /
    • 2019
  • Objective: This study investigated the effect of different acute heat stress (HS) levels on chicken meat quality and ultra-structure. Methods: Chickens were randomly divided into 7 groups to receive different HS treatments: i) $36^{\circ}C$ for 1 h, ii) $36^{\circ}C$ for 2 h, iii) $38^{\circ}C$ for 1 h, iv) $38^{\circ}C$ for 2 h, v) $40^{\circ}C$ for 1 h, vi) $40^{\circ}C$ for 2 h, and vii) un-stressed control group ($25^{\circ}C$). Blood cortisol level, breasts initial temperature, color, pH, water holding capacity (WHC), protein solubility and ultra-structure were analyzed. Results: HS temperatures had significant effects on breast meat temperature, lightness ($L^*$), redness ($a^*$), cooking loss and protein solubility (p<0.05). The HS at $36^{\circ}C$ increased $L^*{_{24h}}$ value (p<0.01) and increased the cooking loss (p<0.05), but decreased $a^*{_{24h}}$ value (p<0.05). However, as the temperature increased to $38^{\circ}C$ and $40^{\circ}C$, all the values of $L^*{_{24h}}$, cooking loss and protein denaturation level decreased, and the differences disappeared compared to control group (p>0.05). Only the ultimate $pH_{24h}$ at $40^{\circ}C$ decreased compared to the control group (p<0.01). The pH in $36^{\circ}C$ group declined greater than other heat-stressed group in the first hour postmortem, which contributed breast muscle protein degeneration combining with high body temperature, and these variations reflected on poor meat quality parameters. The muscle fiber integrity level in group $40^{\circ}C$ was much better than those in $36^{\circ}C$ with the denatured position mainly focused on the interval of muscle fibers which probably contributes WHC and light reflection. Conclusion: HS at higher temperature (above $38^{\circ}C$) before slaughter did not always lead to more pale and lower WHC breast meat. Breast meat quality parameters had a regression trend as HS temperature raised from $36^{\circ}C$. The interval of muscle fibers at 24 h postmortem and greater pH decline rate with high body temperature in early postmortem period could be a reasonable explanation for the variation of meat quality parameters.

극소불량 공정보증을 위한 모형연구 (Model for Process Quality Assurance When the Fraction Nonconforming is Very Small)

  • Jong-Gurl Kim
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 1999년도 추계학술대회
    • /
    • pp.247-257
    • /
    • 1999
  • There are several models for process quality assurance by quality system(ISO 9000), process capability analysis, acceptance control chart and so on. When a high level process capability has been achieved, it takes a long time to monitor the process shift, so it is sometimes necessary to develop a quicker monitoring system. To achieve a quicker quality assurance model for high-reliability process, this paper presents a model for process quality assurance when the fraction nonconforming is very small. We design an acceptance control chart based on variable quality characteristic and time-censored accelerated testing. The distribution of the characteristics is assumed to be normal of lognormal with a location parameter of the distribution that is a linear function of a stress. The design parameters are sample size, control limits and sample proportions allocated to low stress. These parameters are obtained under minimization of the relative variance of the MLE of location parameter subject to APL and RPL constraints.

  • PDF