• 제목/요약/키워드: Pumping test

검색결과 302건 처리시간 0.024초

암반공압파쇄에 의한 지하수량 증대효과 분석

  • 김혜빈;부성안;이기철;김종태
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2003년도 총회 및 춘계학술발표회
    • /
    • pp.47-50
    • /
    • 2003
  • We carried out rock pneumatic fracturing test which to increase groundwater yield by injection of highly pressured air in artificially under the surface every four borehole. The result of test performing shows that effect of increasing groundwater was not found in three testhole around igneous and metamorphic formation area, but we can realized that about 15 percent increased wateryield appeared in number P-5 test hole at sedimmentary rock formation.

  • PDF

Numerical Simulation of Water Table Drawdown due to Groundwater Pumping in a Contaminated Aquifer System at a Shooting Test Site, Pocheon, Korea

  • Kihm, Jung-Hwi;Hwang, Gisub
    • 자원환경지질
    • /
    • 제54권2호
    • /
    • pp.247-257
    • /
    • 2021
  • The study area has been contaminated with explosive materials and heavy metals for several decades. For the design of the pump and treat remediation method, groundwater flow before and during groundwater pumping in a contaminated aquifer system was simulated, calibrated, and predicted using a generalized multidimensional hydrological numerical model. A three-dimensional geologic formation model representing the geology, hydrogeology, and topography of the aquifer system was established. A steady-state numerical simulation with model calibration was performed to obtain initial steady-state spatial distributions of groundwater flow and groundwater table in the aquifer system before groundwater pumping, and its results were illustrated and analyzed. A series of transient-state numerical simulations were then performed during groundwater pumping with the four different pumping rates at a potential location of the pumping well. Its results are illustrated and analyzed to provide primary reference data for the pump and treat remediation method. The results of both steady-state and transient-state numerical simulations show that the spatial distribution and properties of the geologic media and the topography have significant effects on the groundwater flow and thus depression zone.

다단 원판형 드래그펌프의 배기 성능에 관한 실험적 연구 (An Experimental Study on the Pumping Performance of the Multi-stage Disk-type Drag Pump)

  • 권명근;허중식;황영규
    • 한국진공학회지
    • /
    • 제12권2호
    • /
    • pp.79-85
    • /
    • 2003
  • 다단 원판형 드래그펌프의 배기특성을 출구측 압력변화에 따른 입구측의 압력을 측정함으로써 파악하였다. 압력측정범위는 유량이 없을 때 출구측에서 0.13∼533 Pa로 하였다. 펌프 로터의 회전 속도는 24,000rpm이며, 질소가스를 사용하여 유량에 대한 성능실험을 수행하였다. 본 연구에서는 원판의 단의 수에 따른 원판형 드래그 펌프의 성능을 측정하였다. 3단, 2단, 단단형으로 원판형 드래그펌프를 구성하여 성능 실험하였으며, 최대도달진공도, 최대압축비, 배기속도등을 각각 측정하여 상호 성능을 비교·고찰하였다.

맥동관형 크라이오펌프 시제품 성능예측과 평가 (Performance Estimation and Test of Protype Pulse Tube Cryopump)

  • 인상렬;강상백
    • 한국진공학회지
    • /
    • 제22권2호
    • /
    • pp.45-54
    • /
    • 2013
  • 맥동관형 크라이오펌프 개발 사업 2단계를 맞아 우성진공(유)을 중심으로 상용화 시제품 개발이 성공적으로 끝나가고 있다. 최종 크라이오펌프 개발품은 흡기구 직경(내경) 16.5 (14) 인치에 질소 배기속도 3,600 L/s 이상을 목표로 하고 있다. 개발품의 성능확인을 위해 우선 몬테카를로 계산을 통해 배기속도를 예측하고 구조설계를 최적화했으며 이를 바탕으로 가공 조립된 크라이오펌프 시제품의 성능을 표준화된 장치에서 표준화된 절차를 통해 평가하여 설계 목표값과 비교했다. 시제품의 질소 배기속도는 4,600 L/s로 측정되어 설계값과 잘 일치하였으며 개발목표를 훨씬 상회하였다.

Prediction of concrete pumping based on correlation between slump and rheological properties

  • Lee, Jung Soo;Kim, Eun Sung;Jang, Kyong Pil;Park, Chan Kyu;Kwon, Seung Hee
    • Advances in concrete construction
    • /
    • 제13권5호
    • /
    • pp.395-410
    • /
    • 2022
  • This study collected the results of material tests and full-scale pumping tests using 127 types of concrete mixtures with compressive strength ranging from 24 to 200 MPa. The results of 242 material tests showed high correlations between the viscosity of the lubricating layer and concrete, between the slump and the yield stress of concrete, between the water-binder ratio and the viscosity of lubricating layer, and between the time required to reach 500 mm of slump flow and concrete viscosity. Based on these correlations, pumpability was predicted using 101 pumping test conditions, and their accuracy was compared to the actual test results. When the rheological properties of concrete and the lubricating layer were directly measured, the prediction result showed the highest accuracy. A high accuracy can be achieved when the measured viscosity of the lubricating layer, a key determinant of concrete pumpability, is reflected in the prediction of pumpability. When measuring rheological properties is difficult, the slump test can be used to quantitatively predict the pumpability despite the lower accuracy than those of other prediction methods.

실내 모형반복실험에 의한 철도노반재료의 성능 평가 (Evaluation of Performance of the Railroad Roadbed Material by Model Fatigue lest)

  • 황선근;이성혁;이시한;최찬용
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.191-198
    • /
    • 2000
  • Dynamic fatigue test is carried out using soil model box for the evaluation of performance of three different roadbed materials. Bearing capacity, settlement and mud pumping phenomenon of each roadbed materials as well as penetration of model ballast into the roadbeds are investigated. It was found that settlement of slag and crushed stone roadbed is smaller than the soil roadbed during dynamic fatigue test with same initial conditions.

  • PDF

현장조사에 의한 국내 해안 폐기물 매립장의 침출수 거동과 수리특성 (Leachate Behavior and Hydraulic Property of Domestic Seashore Landfill From Field Investigation)

  • 장연수;조용주
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 1998년도 공동 심포지엄 및 추계학술발표회
    • /
    • pp.32-37
    • /
    • 1998
  • In this paper, the role of intermediate cover soils with respect to the leachate and gas flow is investigated from various field investigations and the hydraulic conductivity of the disposed waste is obtained using pumping and slug tests. From the results of field investigations, it was found that the flow of leachate and gas is prevented by the buried cover soils. The hydraulic conductivities of field pumping test and slug tests are well matched and stayed in the range of hydraulic conductivities of well compacted wastes in the literature.

  • PDF

김해 딴섬의 고투수성 누수 피압대수층에서 수리전도도의 규모종속효과 (The Scale-dependent of Hydraulic Conductivity in Leaky Confined Aquifer with High Permeability at the Ttaan Isle, Gimhae City)

  • 김태영;강동환;김성수;김병우;권병혁
    • 지질공학
    • /
    • 제18권4호
    • /
    • pp.415-422
    • /
    • 2008
  • 강변여과수 개발예정지역인 낙동강과 밀양강의 합류지점에 위치한 김해시 딴섬 지역에 형성된 지표면하 $25{\sim}35\;m$ 구간의 고투수성 누수 피압대수층 내 수리전도도의 규모종속효과를 규명하기 위해 양수시험이 수행되었다. 양수시험 시 관측정은 양수정(PW)을 기준으로 남서 방항(MW1, MW2), 북동 방향(MW3, MW4)에 2 m와 5 m 간격으로 개발되었다. 양수시험은 $2,500\;m^3/day$의 양수율로 수행되었으며, 양수 후 경과시간에 따른 수위변화 자료를 AQTESOLV 3.5 프로그램에 입력하여 수리전도도를 산정하였다. 양수정에서 산정된 수리전도도는 $1.745{\times}10^{-3}\;m/sec$ 이었으며, 양수정과 MW1 공 사이의 수리전도도는 $2.452{\times}10^{-3}m/sec$, 양수정과 HW2공 사이의 수리전도도는 $2.161{\times}10^{-3}m/sec$, 양수정과 MW3 공 사이의 수리전도도는 $2.270{\times}10^{-3}m/sec$, 양수정과 MW4공 사이의 수리전도도는 $2.591{\times}10^{-3}m/sec$로 산정되었다. 양수정과 관측정의 이격거리(d)에 따른 수리전도도(K) 증가함수는 남서 방향(PW-MW1-MW2 라인)에서는 logK = 0.0693logd - 2.671, 북동 방향(PW-MW3-MW4 라인)에서는 logK = 0.0817logf - 2.655로 추정되었다. 양수정을 기준으로 남서 방향과 북동 방향 대수층에서의 이격거리에 대한 수리전도도 증가함수는 유사하였다. Schulze-Makuch et al. (1999)의 규모지수 산정방법을 적용하여, 시험대수층의 시험부피에 대한 수리전도도의 규모지수를 산정하였다. 본 시험대수층의 규모지수는 0.15로서 낮게 나타났으며, 이는 시험대수층이 고투수성 자갈층으로서 불균질성이 매우 낮음을 의미한다. 양수시험에 의해 산정된 투수량계수, 양수시험 시 최대수위변화, 양수정과 관측공 간의 거리 및 양수율에 의해 산정된 영향반경은 남서 방향 7.148 m, 북동 방향 6.912 m로 산정되었다. 양수정에서 영향반경까지의 수리전도도 증가율은 남서 방향 1.40배, 북동 방향 1.49배 정도로서 본 시험대수층 매질의 불균질성이 북동 방향에서 약간 높은 것으로 나타났다.

Understanding Hydrogeologic Characteristics of a Well Field of Pyosun in Jeju Volcanic Island of Korea

  • Lee, Jin-Yong;Lee, Gyu-Sang;Song, Sung-Ho
    • 한국지구과학회지
    • /
    • 제29권5호
    • /
    • pp.396-407
    • /
    • 2008
  • Hydrogeologic properties of a well field around middle mountainous areas in Pyosun, Jeju volcanic island were examined based on water level monitoring, geologic logging and pumping test data. Due to the alternating basaltic layers with varying permeability in the subsurface, it is difficult to analyze the hydraulic responses to artificial pumping and/or natural precipitation. The least permeable layer, detrital materials with clay, is found at a depth of 200 m below surface, but it is not an upper confining bed for lower main aquifer. Nevertheless, this layer may serve as a natural barrier to vertical percolation and to contaminant migration. Water levels of the production wells are dominantly affected by pumping frequently, while those of the remote observation wells are controlled by ambient precipitation. Results of pumping tests revealed a possible existence of horizontal anisotropy of transmissivity. However, some results of this study include inherent limitations enforced by field conditions such as the consistent of groundwater production and the set of time periods for the cessation of the pumping prior to pumping tests.

펌프제어밸브를 사용한 취수펌프장에서의 수격현상 (Waterhammer for the Intake Pumping Station with the Pump Control Valve)

  • 김경엽;오상현
    • 한국유체기계학회 논문집
    • /
    • 제4권4호
    • /
    • pp.16-21
    • /
    • 2001
  • The field tests on the waterhammer were carried out for PalDang intake pumping station of the metropolitan water supply 5th stage project. The pumping station was equipped with the pump control valve as the main surge suppression device and the surge relief valve as auxiliary. However, the pump control valve had not been early controlled in the planned closing mode, and the slamming occurred to the valve which abruptly closed during the large reverse flow. Because the pressure wave caused by the pump failure was superposed on the slam surge, the upsurge increased so extremely that the shaft of the valve was damaged. It was desirable that the surge relief valve was installed in the pumping station or near the pump exit for the delay of response. After reforming the oil dashpot of the pump control valve, the sliming disappeared and the measured pressure was in fairly good agreement with the results of simulation. In case of three pumps for ${\phi}2,600$ pipeline being simultaneously tripped, the pressure head in the pumping station increased to 95.6 m, and the upsurge caused by the emergency stop of four pumps for ${\phi}2,800$ pipeline was 89.6m. We concluded that the pumping station acquired the safety and reliability for the pressure surge.

  • PDF