• Title/Summary/Keyword: Pumping chamber

Search Result 85, Processing Time 0.029 seconds

Simulation of Vacuum Characteristics of High Vacuum System Modelled by VacCAD

  • Kim, Hyungtaek;Park, Junhyung;Yun, Gyeongah
    • International journal of advanced smart convergence
    • /
    • v.7 no.4
    • /
    • pp.84-91
    • /
    • 2018
  • In this paper, we simulated three different HV systems and analyzed of each vacuum characteristics by VacCAD modelling. In each of modelled vacuum systems, selection of chamber materials, combination of rough pump with high vacuum pump and conductance of roughing line (diameter and length) were proposed as system variables. In the modelling of chamber materials, the pumping times to ultimate pressures of different chamber materials (stainless steel, aluminum) were compared by the variations of chamber volume. In this model, the effects of outgassing dependent on the chamber materials was also simulated and aluminum was estimated to optimum chamber materials. It was also obtained that modelling of vane and roots pump with diffusion pump and diameter, length of $50{\times}250$ [mm]roughing line were characterized as optimum variables to reach the ultimate pressure of 10E-7 [mbar] most effectively. Optimum design factors for vacuum characteristics of modelled vacuum system were achieved by VacCAD simulations. Feasibility of VacCAD as vacuum simulator was verified and applications of VacCAD expected to be increased to fields in vacuum needed.

A Study About PDMS-Glass Based Thermopneumatic Micropump Integrated with Check Valve (체크밸브가 달린 열공압 방식의 PDMS-유리마이크로 펌프에 관한 연구)

  • Ko, Young-June;Cho, Woong;Ahn, Yoo-Min
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.9
    • /
    • pp.720-727
    • /
    • 2008
  • Microfluidic single chip integrating thermopneumatic micropump and micro check valve are developed. The micropump and micorvalve are made of biocompatible materials, glass and PDMS, so as to be applicable to the biochip. By using the passive-type check valve, backward flow and fluid leakage are blocked and flow control is stable and precise. The chip is composed of three PDMS layers and a glass substrate. In the chip, flow channel and pump chamber were made on the PDMS layers by the replica molding technique and pump heater was made on the glass substrate by Cr/Au deposition. Diameter of the pump chamber is 7 mm and the width and depth of the channel are 200 and $180{\mu}m$, respectively. The PDMS layers chip and the heater deposited glass chip are combined by a jig and a clamp for pumping operation, and they are separable so that PDMS chip is used as a disposable but the heater chip is able to be used repeatedly. Pumping performance was simulated by CFD software and investigated experimentally. The performance was the best when the duty ratio of the applied voltage to the heater was 33%.

A Study on Ignition Probability and Combustion Characteristics of Low Pressure Direct Injection LPG according to a Function of Ambient Condition (분위기 조건 변화에 따른 저압 직접분사식 LPG의 점화성 및 연소특성 연구)

  • Chung, Sung-Sik;Hwang, Seong-Ill;Yeom, Jeong-Kuk;Jeon, Byong-Yeul
    • Journal of Power System Engineering
    • /
    • v.20 no.2
    • /
    • pp.32-42
    • /
    • 2016
  • Under part load condition of spark-ignition engine, pumping loss had great effect on engine efficiency. To reduce pumping loss, the study designed spark-ignited engines to make direct spray of gasoline to combustion chamber. In spark-ignited direct-injection engines, ignition probability is important for successful combustion and flame propagation characteristics are also different from pre-mixed combustion. This study designed a visualization testing device to study ignition probability of spark-ignited direct-injection LPG fuel and combustion flame characteristics. This visualization device consists of combustion chamber, fuel supply system, air supply system, electronic control system and data acquisition system. Ambient pressure, ambient temperature and ambient air flow velocity are important parameters on ignition probability of LPG-air mixture and flame propagation characteristics, and the study also found that sprayed LPG fuel can be directly ignited by spark-plug under proper ambient conditions. To all successful cases of ignition, the study recorded flame propagation image in digital method through ICCD camera and its flame propagation characteristics were analyzed.

Outgassing and thermal desorption measurement system for parts of CRT (CRT 부품용 탈가스 및 Thermal Desorption 측정장치 개발)

  • Sin, Yong Hyeon;Hong, Seung Su;Mun, Seong Ju;Seo, Il Hwan;Jeong, Gwang Hwa
    • Journal of the Korean Vacuum Society
    • /
    • v.6 no.4
    • /
    • pp.298-307
    • /
    • 1997
  • TDS(Thermal Desorption Spectroscopy)system, for diagnosis of CRT manufacturing process, was designed and constructed. Outgassings and thermal desorptions from the part or materials of CRT can be measured and analysed with this system at various temperatures. The system is consisted of 3 parts, vacuum chamber and pumping system with variable conductance, sample heating stages & their controller, and outgassing measurement devices, like as ion gauge or quadrupole mass spectrometer. The ultimate pressure of the system was under $1{\times}10^{-7}$ Pa. With the variable conductance system, the effective pumping speed of the chamber could be controlled from sub l/s to 100 l/s. The effective pumping speed values were determined by dynamic flow measurement principle. The temperatures and ramp rate of sample were controlled by tungsten heater and PID controller up to 600℃ within ±1℃ difference to setting value. Ion gauge & QMS were calibrated for quantitative measurements. Some examples of TDS measurement data and application on the CRT process analysis were shown.

  • PDF

Construction of CVD by using RF Helicon Plasma (RF 헬리콘 플라즈마를 이용한 회학기상 증착기의 제작)

  • 신재균;현준원;박상규
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.8
    • /
    • pp.607-612
    • /
    • 1998
  • RF HPCVD(Helicon Plasma Chemical Vapor Deposition) has been successfully constructed for diamond thin films. The system consists of plasma generation tube, deposition chamber, pumping lines for gas system. A mixture of $CH_4 and H_2$is used for reaction. Two thermocouples, a quartz tube surrounded by a RF antenna and a magnet, and a high temperature heater were set up in the deposition chamber. The process for the thin film diamond deposition has been carried put in a high vacuum system at a substrate temperature of $800^{\circ}C$, and pressure of 5 mtorr. It is also demonstrated. that the RF HPCVD system has advantages for controlling deposition parameters easily.

  • PDF

EDDC deposition system for 100m long superconducting coated conductor (100m 급 초전도선재 제조용 EDDC 증착시스템)

  • Kim, Ho-Sup;Ha, Hong-Soo;Oh, Sang-Soo;Ko, Rock-Kil;Yang, Ju-Saeng;Kim, Tae-Hyung;Song, Kyu-Jeong;Ha, Dong-Woo;Park, Yu-Mi;Youm, Do-Jun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.18-19
    • /
    • 2005
  • EDDC(Evaporation using Drum in Dual Chamber) deposition system was manufactured for 100m long superconducting coated conductor. It is composed of reaction chamber, evaporation chamber and differential chamber. The drum is located across the differential and exposed to both of the evaporation chamber and the reaction chamber, and the tape is wound on the drum. The elements of superconducting material are co-evaporated from respective element boats in the evaporation chamber and deposited on the drum and reacted with oxygen in the reaction chamber. This process repeats by rotating the drum. When the total pressure of the reaction chamber was 5 mTorr, that of the evaporation chamber was $5{\sim}10^{-5}$Torr. This atmosphere can be achieved by means of differential pumping. There are four evaporator in the evaporation chamber. One is the radiation heating evaporator and the others are the high frequency induction evaporator. EDDC is one of promising methods for commercialization of superconducting coated conductor.

  • PDF

A Study for Regulating Flow Fluctuation and Preventing Backflow of Peristaltic Pump (연동펌프의 유량맥동 조절과 역류현상을 방지하는 장치에 대한 연구)

  • Jeong, Yoo-seok;Lee, Cheol-Soo;Lee, Tae-Kyung
    • The KSFM Journal of Fluid Machinery
    • /
    • v.19 no.5
    • /
    • pp.28-34
    • /
    • 2016
  • Though a peristaltic pump is a crucial element in miniaturized drug delivery systems, it has some intrinsic disadvantages such as backflow and flow fluctuation. To overcome these limitation, we have developed valve-less peristaltic pump system including orifice and stagnation chamber. we measured flow rate to investigate the performance of rotary peristaltic pump with three rollers and an elastomeric tube pumping a viscous fluid. The flow fluctuations and the backflow happen as a result from the disengagement of the contact interaction between the rollers and the tubes. Stagnation chamber installed in front of orifice plate was composed of rubber tube and gas chamber. By changing orifice hole diameter with stagnation chamber flow rate and pressure in the tube was regulated. The obtained maximum reduction ratio of flow fluctuation is 96.79%.

Analysis of the experimental cooling performance of a high-power light-emitting diode package with a modified crevice-type vapor chamber heat pipe

  • Kim, Jong-Soo;Bae, Jae-Young;Kim, Eun-Pil
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.8
    • /
    • pp.801-806
    • /
    • 2015
  • The experimental analysis of a crevice-type vapor chamber heat pipe (CVCHP) is investigated. The heat source of the CVCHP is a high-power light-emitting diode (LED). The CVCHP, which exhibits a bubble pumping effect, is used for heat dissipation in a high-heat-flux system. The working fluid is R-141b, and its charging ratio was set at 60 vol.% of the vapor chamber in a heat pipe. The total thermal conductivity of the falling-liquid-film-type model, which was a modified model, was 24% larger than that of the conventional model in the LED package. Flow visualization results indicated that bubbles grew larger as they combined. These combined bubbles pushed the working fluid to the top, partially wetting the heat-transfer area. The thermal resistance between the vapor chamber and tube in the modified design decreased by approximately 32%. The overall results demonstrated the better heat dissipation upon cooling of the high-power LED package.

Experimental Study on the Effect of Air Chamber Size and Operation Parameters on the Performance of a Hydraulic Ram Pump (압력실의 크기와 운전 조건에 따른 수격펌프의 성능에 대한 실험적 고찰)

  • Ngolle, Enongene Ebong George;Hong, Seong Gu
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.61 no.4
    • /
    • pp.55-61
    • /
    • 2019
  • Motor pumps cannot be used in those areas where electricity is not accessible such as remote rural areas in many African countries. Hydraulic ram pump is one of the solutions for supplying water for irrigation or domestic uses. The hydraulic ram pumps are working based on the water hammer effect for pumping without external power or electricity. This study was conducted to investigate the effect of air chamber volume and operation parameters on the performance of the hydraulic ram pump which was assembled with common plumbing parts. The experimental results showed the volume of the air chamber did not affect the performance such as discharge rate and head. When drive heights were 1.7 and 2.35 m, the maximum discharge heads were up to 7 m and 10 m, respectively. When the air chamber volume was 1 L, discharge rates were 0.23 and 2.12 L/min under the drive heights of 1.7 and 2.35 m, respectively. The average energy efficiency of the hydraulic ram pump assembled in this study was about 60% for all the experimental conditions.

Fabrication and Vacuum Performance Test of the NEG Pump for $10^{-9}$ Pa Chamber ($10^{-9}$ Pa대 용기를 위한 NEG 펌프 제작 및 진공성능 조사)

  • 박미영;인상렬
    • Journal of the Korean Vacuum Society
    • /
    • v.10 no.3
    • /
    • pp.312-320
    • /
    • 2001
  • A Non-Evaporable Getter(NEG) pump was fabricated using Zr-V-Fe alloy modules to obtain $10^{-9}$ Pa range pressures. Pumping performances and activation characteristics were investigated and the pumping speeds for hydrogen, deuterium and carbon monoxide gases of the NEG pump were measured. And hydrogen desorption characteristics were examined during activation at $450^{\circ}C$. Futhermore the vacuum performance was compared with those of other high vacuum pumps as turbo-molecular pump, sputter-ion pump, and cryo pump by analyzing the residual gases of the system.

  • PDF