• 제목/요약/키워드: Pump system

검색결과 2,893건 처리시간 0.034초

디젤차량용 통합연료히터의 저온유동성 성능평가 (Low Temperature Fluidity Performance Evaluation of Composited Package Fuel Heater for Diesel Cars)

  • 이정화;박형원;이웅수;이영재;이보희;윤달환
    • 전기전자학회논문지
    • /
    • 제18권1호
    • /
    • pp.152-158
    • /
    • 2014
  • 본 연구에서는 저온유동성 성능검사 시스템 구현을 통해 디젤 차량용 통합형 연료히터의 성능을 평가한다. 저온 유동성 시험장치에서 $+20{\sim}-30^{\circ}C$ 온도범위에 따라 분리형과 통합형 연료히터 성능을 비교하고, 필터 전후에 따라 유압과 시동시간, 히터의 소모전력을 측정한다. 이때 다양한 종류의 필터면적을 사용함으로써 통합형 연료히터와 분리형을 비교한 결과 시동 시간이 23% 향상되었고, 저온시동성능은 19% 정도 향상된다.

A New Photovoltaic System Architecture of Module-Integrated Converter with a Single-sourced Asymmetric Multilevel Inverter Using a Cost-effective Single-ended Pre-regulator

  • Manoharan, Mohana Sundar;Ahmed, Ashraf;Park, Joung-Hu
    • Journal of Power Electronics
    • /
    • 제17권1호
    • /
    • pp.222-231
    • /
    • 2017
  • In this paper, a new architecture for a cost-effective power conditioning systems (PCS) using a single-sourced asymmetric cascaded H-bridge multilevel inverter (MLI) for photovoltaic (PV) applications is proposed. The asymmetric MLI topology has a reduced number of parts compared to the symmetrical type for the same number of voltage level. However, the modulation index threshold related to the drop in the number of levels of the inverter output is higher than that of the symmetrical MLI. This problem results in a modulation index limitation which is relatively higher than that of the symmetrical MLI. Hence, an extra voltage pre-regulator becomes a necessary component in the PCS under a wide operating bias variation. In addition to pre-stage voltage regulation for the constant MLI dc-links, another auxiliary pre-regulator should provide isolation and voltage balance among the multiple H-bridge cells in the asymmetrical MLI as well as the symmetrical ones. The proposed PCS uses a single-ended DC-DC converter topology with a coupled inductor and charge-pump circuit to satisfy all of the aforementioned requirements. Since the proposed integrated-type voltage pre-regulator circuit uses only a single MOSFET switch and a single magnetic component, the size and cost of the PCS is an optimal trade-off. In addition, the voltage balance between the separate H-bridge cells is automatically maintained by the number of turns in the coupled inductor transformer regardless of the duty cycle, which eliminates the need for an extra voltage regulator for the auxiliary H-bridge in MLIs. The voltage balance is also maintained under the discontinuous conduction mode (DCM). Thus, the PCS is also operational during light load conditions. The proposed architecture can apply the module-integrated converter (MIC) concept to perform distributed MPPT. The proposed architecture is analyzed and verified for a 7-level asymmetric MLI, using simulation results and a hardware implementation.

수직 상향유동 배관에서 비뉴톤유체에 의한 2상류의 유동특성 (The Characteristics of Two Phase Flow by Non-Newtonian Fluid for Vertical Up-ward in a Tube)

  • 차경옥;김재근;최경석
    • 한국가스학회지
    • /
    • 제2권4호
    • /
    • pp.53-59
    • /
    • 1998
  • 기-액 2상유동장에서 유동양식은 압력강하, 보이드율분포, 유동장의 기하학적 형상과 밀접한 관계가 있다. 한편 원유수송, 비등이 발생하는 유동, 펌프에서 발생하는 케비테션 현상, 그리고 화학 반응로와 같은 상변화 장치 등의 2상유동에서 고분자물질에 의한 저항감소 현상의 적용이 가능할 것으로 예상된다. 그러나 2상유동장에서 고분자물질에 의한 저항감소에 관한 연구는 매우 미비하다. 그래서 본 연구는 2상유동장에 합성고분자물질(A611p)에 의한 저항감 소율을 실험을 통하여 계측 및 분석하였다. 본 연구에서는 고분자물질의 농도를 증가시킬수록 국부보이드율의 최고치가 관의 중심에서 관의 벽쪽으로 이동하며 2상유동의 유동양식이 변화됨을 규명하였다. 그래서 저항감소율과 유동양식과 밀접한 관계가 있음을 예측할 수 있었다.

  • PDF

중앙구동 이젝터의 설계변수에 따른 유동특성 (Flow Characteristics of Central-Driven Ejector with Design Parameters)

  • 박상규;양희천
    • 대한기계학회논문집B
    • /
    • 제39권8호
    • /
    • pp.645-651
    • /
    • 2015
  • 본 논문은 중앙구동 이젝터의 유량비에 미치는 설계변수의 영향에 대한 연구를 목적으로 한다. 중앙구동 이젝터의 설계변수는 구동노즐 출구 단면적 및 거리비, 디퓨저 출구 단면적비로 설정하였다. 실험장치는 가변노즐 이젝터, 전동 모터-펌프, 구동유체 저장수조, 제어판넬 그리고 고속 카메라 시스템으로 구성하였다. 유량비는 실험변수에 따라 측정되는 유입 공기량과 구동유체인 물의 유량을 이용하여 도출하였다. 유량비는 구동노즐 거리비와 혼합관 길이비가 커지면 증가하는 반면에, 구동노즐 면적비와 디퓨저 출구 면적비가 커지면 감소하였다.

모래운반선의 창구덮개 면제를 위한 시설기준에 관한 연구 (A Study on the Release of Hatch Cover in Sand Carriers)

  • 정창현
    • 해양환경안전학회지
    • /
    • 제18권5호
    • /
    • pp.439-445
    • /
    • 2012
  • 모래운반선은 호퍼도어를 갖는 경우 제한된 범위내에서 창구덮개의 설치를 면제 받을 수 있으나, 현재 국내에는 호퍼도어를 갖고 있는 선박이 단 한척도 없어 창구덮개를 면제받는 선박이 없는 실정이다. 따라서 모래운반선의 창구덮개 관련 현행 규정의 검토와 사고사례 조사 그리고 현재 운항하고 있는 모래운반선에 대한 설비현황, 복원성능 및 내항성능 평가를 통하여 모래운반선에 대한 창구덮개 면제 조건을 검토하였다. 그 결과, 모래운반선의 경우 창구덮개를 면제 받기 위해서는 화물창의 크기를 조정하여 모래를 화물창 상단부까지 가득 싣더라도 흘수가 만재흘수선을 넘지 않도록 하고, 적절한 풍우밀 조치를 취함으로써 충분한 예비 부력과 복원력 확보가 요구된다. 또한, 배수펌프의 용량은 화물창의 액상상태인 모래를 1시간 이내에 소성상태가 될 수 있도록 배수하기에 충분한 용량이어야 하며, 모든 운항상태에서 작동 가능하여야 한다. 본 연구는 모래운반선의 작업 특성상 창구덮개의 설치작업이 현실적으로 상당히 어렵고, 특히 기상악화시 인명사고로 이어질 수 있는 현실적인 문제점을 항해안전과 관련된 시설기준을 보다 강화함으로써 개선한 것이다.

유압식 인버터 엘리베이터의 속도제어를 위한 하이브리드 슬라이딩모드제어기 (Hybrid Sliding-Mode Controller for the Speed Control of a Hydraulic Inverter-Fed Elevator)

  • 한권상;박재삼;안현식;김도현
    • 전자공학회논문지SC
    • /
    • 제38권6호
    • /
    • pp.37-47
    • /
    • 2001
  • 인버터를 적용한 유압식 엘리베이터 시스템은, 펌프와 실린더 패킹 및 탑승카의 마찰특성으로 인하여 PID 제어기로는 제어가 되지 않는 데드존이 발생하게 된다. 본 논문에서는 이러한 문제를 해결하기 위하여 슬라이딩모드제어기와 PID 제어기를 혼용하여, 출력혼합기의 출력을 절환시키는 구조를 가진 새로운 하이브리드제어기를 제시하여 제어성능을 향상시킨다. 먼저, 인버터를 적용한 유압식 엘리베이터의 속도제어를 위한 슬라이딩모드제어기 설계방법을 제시하고, 이어서 하이브리드 제어기의 설계방법을 제시한다. 제안된 하이브리드 슬라이딩모드제어기가 극저속 속도영역에서 뿐만 아니라 정상상태를 포함한 전 운전 영역에서 제어 성능이 개선됨을 시뮬레이션 결과를 통하여 보인다.

  • PDF

TRNOPT를 이용한 수직 지중열교환기 길이 산정 방법에 관한 연구 (Sizing of Vertical Borehole Heat Exchangers using TRNOPT)

  • 박승훈;이현수;장용성;김의종
    • 설비공학논문집
    • /
    • 제28권10호
    • /
    • pp.402-407
    • /
    • 2016
  • Ground-coupled heat pump systems have been widely used, as they are regarded as a renewable energy source and ensure a high annual efficiency. Among the system components, borehole heat exchangers (BHE) play an important role in decreasing the entering water temperature (EWT) to heat pumps in the cooling season, and consequently improve the COP. The optimal sizing of the BHEs is crucial for a successful project. Other than the existing sizing methods, a simulation-based design tool is more applicable for modern complex geothermal systems, and it may also be useful since design and engineering works operate on the same platform. A simulation-based sizing method is proposed in this study using the well-known Duct STorage (DST) model in Trnsys. TRNOPT, the Trnsys optimization tool, is used to search for an optimal value of the length of BHEs under given ground loads and ground properties. The result shows that a maximum EWT of BHEs during a design period (10 years) successfully approaches the design EWT while providing an optimal BHE length. Compared to the existing design tool, very similar lengths are calculated by both methods with a small error of 1.07%.

A FLOW AND PRESSURE DISTRIBUTION OF APR+ REACTOR UNDER THE 4-PUMP RUNNING CONDITIONS WITH A BALANCED FLOW RATE

  • Euh, D.J.;Kim, K.H.;Youn, Y.J.;Bae, J.H.;Chu, I.C.;Kim, J.T.;Kang, H.S.;Choi, H.S.;Lee, S.T.;Kwon, T.S.
    • Nuclear Engineering and Technology
    • /
    • 제44권7호
    • /
    • pp.735-744
    • /
    • 2012
  • In order to quantify the flow distribution characteristics of APR+ reactor, a test was performed on a test facility, ACOP ($\underline{A}$PR+ $\underline{C}$ore Flow & $\underline{P}$ressure Test Facility), having a length scale of 1/5 referring to the prototype plant. The major parameters are core inlet flow and outlet pressure distribution and sectional pressure drops along the major flow path inside reactor vessel. To preserve the flow characteristics of prototype plant, the test facility was designed based on a preservation of major flow path geometry. An Euler number is considered as primary dimensionless parameter, which is conserved with a 1/40.9 of Reynolds number scaling ratio. ACOP simplifies each fuel assembly into a hydraulic simulator having the same axial flow resistance and lateral cross flow characteristics. In order to supply boundary condition to estimate thermal margins of the reactor, the distribution of inlet core flow and core exit pressure were measured in each of 257 fuel assembly simulators. In total, 584 points of static pressure and differential pressures were measured with a limited number of differential pressure transmitters by developing a sequential operation system of valves. In the current study, reactor flow characteristics under the balanced four-cold leg flow conditions at each of the cold legs were quantified, which is a part of the test matrix composing the APR+ flow distribution test program. The final identification of the reactor flow distribution was obtained by ensemble averaging 15 independent test data. The details of the design of the test facility, experiment, and data analysis are included in the current paper.

토노메트리 방식 맥파 측정의 가압 각도에 따른 변동성 평가 (Variation Factor Assessment of Radial Artery Pulse by the Tonometry Angle of the Pulse Pressure Sensor)

  • 정창진;조정희;전민호;전영주;김영민
    • 센서학회지
    • /
    • 제25권2호
    • /
    • pp.138-142
    • /
    • 2016
  • A pulse measurement by tonometry provides useful information for diagnosis, including not only blood pressure and heart rate but also parameters for estimating a condition of the cardiovascular system. Currently, various pulse measurement devices based on the tonometry have been developed. A reliability of these devices is determined by a positioning technic between the sensor and the blood vessel and a controlling technique of the pressurization level. An angle of the sensor for the pulse measurement seems to be highly related with a measured signal, however, the objective studies for this issue have been not published. In this paper, the variation of the pulse signals by tonometry direction was experimentally assessed according to the angle of the sensor. In order for guaranteeing the repeatability of the experiment, we used a pulse generator device, which can generate human pulse signal by using silicon tube and fluid pump, and developed a structure for precise adjustment of the angle and the pressurization level of the sensor. The angle of the sensor was acquired by an inclinometer, which was attached at the opposite side of the sensor. As results, a coefficient of variation (CV) of a maximum amplitude (MA) of the pulse wave was largely increased over the angle range of $-9{\sim}9^{\circ}$. Furthermore, the changes of the pulse shape showed different aspects according to the sign of the angle tilted along the blood vessel. It is expected that the results of this study can be helpful for developing more precise pulse measurement devices based on the tonometry and applying in clinic.

지열냉난방시스템 수직형 지중열교환기 그라우트의 열적 특성에 관한 연구 (A Study on Thermal Conductivity Properties of Ground Heat Exchangers for GSHP systems)

  • 백성권;전중규;안형준
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 추계학술대회 논문집
    • /
    • pp.546-549
    • /
    • 2007
  • 지열 냉난방 시스템의 설계는 냉난방 공간의 크기에 따라 필요한 부하를 계산하여 설계하게된 다. 설계 부하를 충분히 소화할 수 있는 지열교환기의 길이와 보어홀의 깊이 및 개수는 지반의 열적 특성에 크게 좌우된다. 열전도율이 큰 지반일수록 지열교환기 내의 열 흡수 및 소산이 효과적으로 이루어져 지열교환기의 길이도 상대적으로 짧아질 수 있다. 즉, 효율적이고 정확한 설계를 하기 위해서는 지반, 암반 및 지중열교환기의 물리적 특성에 따른 열적 특성을 설계자는 미리 숙지하여야 한다. 현재 국내에서 수직 밀폐형 지중열교환기의 그라우트로 벤토나이트를 가장 많이 사용하고 있으나, 해외의 경우 지중 조건에 따라 시멘트 또는 벤토나이트를 적절히 선택하여 시공하고 있다. 이는 벤토나이트의 특성상 적용 조건이 제약을 받기 때문이며, 특히 지하수가 존재하지 않을 경우 사용이 사실상 불가능하다. 국내에서 이에 대한 충분한 연구는 아직 이루어지지 않았으며, 시멘트 그라우트를 사용하기 위한 물리적, 열적 특성에 대한 연구가 필요한 시점이라 판단하여 본 연구를 수행하였다. 시멘트 그라우트의 경우 수화반응이 일어나는 초기의 건조수축을 최소화하는 배합비로 물성을 구성하였으며, 벤토나이트는 일반 현장 시공 비율을 사용하였다. 열전도율은 첫째 실내 시험으로 시멘트 그라우트에 대한 열판시험법과 벤토나이트 그라우트에 대한 탐침시험법으로 수행하여 구하였으며, 두 번째 방법인 현장 시공으로 직접 현장열응답시험을 수행하여 그라우트 간의 열적 특성을 비교하였다. 또한 기존 시멘트그라우트의 열적 특성을 개량한 코오롱건설에서 개발한 시멘트 그라우트에 대한 열적 거동도 기존 타 그라우트의 열적 거동과 비교하였으며, 개발 제품의 성능이 상당히 우수함을 알 수 있었다.

  • PDF