• Title/Summary/Keyword: Pump simulation loop

Search Result 64, Processing Time 0.024 seconds

Similarity evaluation of the pump simulation loop in STELLA-2 for conservation of mechanical sodium pump characteristics

  • Jung Yoon ;Jewhan Lee ;Jaehyuk Eoh;Hyungmo Kim ;Dong Eok Kim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.1
    • /
    • pp.353-363
    • /
    • 2023
  • The STELLA-2 is a large-scale sodium thermal-hydraulic integral effect test facility and supports the development of PGSFR. The facility adopted Pump Simulation Loop System (PSLS) concept for the mechanical sodium pump in the reference reactor to control and to measure the primary sodium flow. Since the component (mechanical pump) is replaced by the loop, it is very important to evaluate the similarity between the pump and the loop. In this paper, to simulate the characteristic of the mechanical sodium pump, the pressure loss along the various options of the loop was evaluated and the comprehensive validity of each design options was analyzed. Using the similarity criteria based on the Richardson number and Euler number conservation, the PSLS design was finalized and the result was within the acceptable error range. Finally, the result of this study was used for construction of the overall facility, STELLA-2.

Phase-Locked Loop with a loop filter consisting of a capacitor and a charge pump functioned as resistor (저항 역할을 하는 전하펌프와 하나의 커패시터로 구성된 루프 필터를 가진 위상고정루프)

  • Park, Jong-Youn;Choi, Hyek-Hwan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.11
    • /
    • pp.2495-2502
    • /
    • 2012
  • This paper presents a new structure of phase looked loop (PLL) for replacing a process sensitive resistor in loop filter with an additional charge pump (CP). The additional charge pump works as a resistor in a loop filter. The output of two charge pumps changes same direction according to process variation. The simulation results according to process conditions(SS/TT/FF) demonstrate that the proposed PLL works properly with process variations. It has been designed with a 1.8V $0.18{\mu}m$ CMOS process and proved by simulation with HSPICE.

Analysis for bit synchronization using charge-pump phase-locked loop (비트 동기 Charge-pump 위상 동기 회로의 해석)

  • 정희영;이범철
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.1
    • /
    • pp.14-22
    • /
    • 1998
  • The Mathematic model of bit synchronization charge-pump Phase Locked Loop (PLL) is presented which takes into account the aperiodic reference pulses and the leakage current of the loop filter. We derive theoreitcal static phase error, overload and stability of bit synchronization charge-pump PLL using presented model and compare it with one of the conventional charge-pump PLL model. We can analysis bit synchronization charge-pump PLL exactly because our model takes into account the leakage current of the loop filter and aperiodic input data which are the charateristics of bit synchronization charge-pump PLL. We also verify it using HSPICE simulation with a bity synchronizer circuit.

  • PDF

Analysis of Startup Characteristics for Turbo Pump Unit-Gas Generator Open Loop Test (터보펌프 조립체-가스발생기 연계 개회로 시험에서의 시동특성 분석)

  • Moon, Yoon-Wan;Kim, Seung-Han;Seol, Woo-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.15-18
    • /
    • 2008
  • This study fulfilled analysis of startup characteristics of Turbo pump unit-Gas generator open loop test from the viewpoint of simulation. The test results were investigated and the calculated results were compared to test results. The curve for RPM developing predicted by simulation agreed well with test result. The slope of transient combustion pressure of gas generator correspond with test result.

  • PDF

Analysis of Startup Characteristics for Turbo Pump Unit-Gas Generator Closed Loop Test (터보펌프 조립체-가스발생기 연계 폐회로 시험에서의 시동특성 분석)

  • Moon, Yoon-Wan;Kim, Seung-Han;Seol, Woo-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.19-22
    • /
    • 2008
  • This study fulfilled analysis of startup characteristics of Turbo pump unit-Gas generator closed loop test from the viewpoint of simulation. The test results were investigated and the calculated results were compared to test results. The curve for RPM developing predicted by simulation agreed well with test result. The slope of transient combustion pressure of gas generator correspond with test result.

  • PDF

Exact analysis for overload of a charge-pump phase-locked loop (Charge-pump 위상 동기 회로의 과부하에 대한 정확한 해석)

  • 최은창;이범철
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.12
    • /
    • pp.3069-3085
    • /
    • 1996
  • This paper shows an accurate charge-pump PLL model which considers the wave-form distortion in high speed operation of charge-pump PLL, the leakage current in loop filter, and a physical limit in charge-pump. With proposed model of charge-pump PLL, overload and stability are derived theoretically and the results are compared to the conventional model. Unlike the ideal charge-pump PLL that simplifies calculations, it is possible to analyze the transient-state and the steady-state at the same time with proposed accurate model. Thus, charge-pump over load, in the transient-state and the stead-state of charge-pump, is accuragely analyzed and the results are confirmed with simulation.

  • PDF

3 Dimensional Numerical Simulation for the Closed Loop Heat Pump System Using TOUGH2 (TOUGH2를 이용한 폐쇄형 지열펌프 시스템의 3차원 모델링 연구)

  • Kim, Seong-Kyun;Bae, Gwang-Ok;Lee, Kang-Kun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.36-39
    • /
    • 2006
  • To evaluate the effect of groundwater flow on the outlet temperature of a geothermal heat pump, 3 dimensional numerical simulations are performed considering both groundwater flow and pipe flow in the U-tube using TOUGHS, The present study involved the following 4 simulation cases (1) no groundwater flow, (2) slow groundwater flow (hydraulic conductivity: $1.0{\times}10^{-9}m/s)$, (3) fast groundwater flow (hydraulic conductivity, $1.0{\times}10^{-7}m/s$), and (4) groundwater flow varying with the depth (hydraulic conductivity: $1.0{\times}10^{-7}-1.0{\times}10^{-10}m/s$). The effect of groundwater flow on the outlet temperature is significant where hydraulic conductivity of aquifer is $1.0{\times}10^{-7}m/s$. Where hydraulic conductivity of aquifer is $1.0{\times}10^{-10}m/s$, however, that effect is negligible.

  • PDF

Numerical analysis of the temperature distribution of the EM pump for the sodium thermo-hydraulic test loop of the GenIV PGSFR

  • Kwak, Jaesik;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • v.53 no.5
    • /
    • pp.1429-1435
    • /
    • 2021
  • The temperature distribution of an electromagnetic pump was analyzed with a flow rate of 1380 L/min and a pressure of 4 bar designed for the sodium thermo-hydraulic test in the Sodium Test Loop for Safety Simulation and Assessment-Phase 1 (STELLA-1). The electromagnetic pump was used for the circulation of the liquid sodium coolant in the Intermediate Heat Transport System (IHTS) of the Prototype Gen-IV Sodium-cooled Fast Reactor (PGSFR) with an electric power of 150 MWe. The temperature distribution of the components of the electromagnetic pump was numerically analyzed to prevent functional degradation in the high temperature environment during pump operation. The heat transfer was numerically calculated using ANSYS Fluent for prediction of the temperature distribution in the excited coils, the electromagnet core, and the liquid sodium flow channel of the electromagnetic pump. The temperature distribution of operating electromagnetic pump was compared with cooling of natural and forced air circulation. The temperature in the coil, the core and the flow gap in the two conditions, natural circulation and forced circulation, were compared. The electromagnetic pump with cooling of forced circulation had better efficiency than natural circulation even considering consumption of the input power for the air blower. Accordingly, this study judged that forced cooling is good for both maintenance and efficiency of the electromagnetic pump.

Analysis of the Initial Cost Payback Period on the Open-loop Geothermal System Using Two Wells (복수정을 이용한 개방형 지열 시스템의 초기투자비 회수기간 분석)

  • Cho, Jeong-Heum;Nam, Yujin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.3
    • /
    • pp.119-126
    • /
    • 2017
  • Recently, ground source heat pump systems are being used in buildings for cooling and heating to reduce greenhouse gas and save energy. However, ground source heat pump systems mainly use the vertical closed-loop geothermal system design rather than the open-loop geothermal system design. This is due to a lack of knowledge and few research feasibility studies. In this research, a dynamic thermal analysis numerical simulation based on a standard house model was conducted for an open-loop geothermal system. Based on heating load analysis results, the life cycle costs of a standard house using an open two-well geothermal system were analyzed and compared with a vertical closed-loop geothermal system, and a diesel boiler. As a result, it was found that using an open two-well geothermal system shows economic return on investment after three years.

A Study on Improving the Efficiency of Ground Heat Exchanger (지중열교환기 성능 향상에 관한 연구)

  • Kim, Ook-Joong;Lee, Kong-Hoon;Kim, Min-Su
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.3142-3147
    • /
    • 2008
  • A simple transient simulation of ground source heat pump system was carried out to investigate the effects of ground thermal conductivity on its performance. The TRNSYS code with a simple water to water heat pump model was used to compare the COP variation of the system. A new ground heat exchanger called by semi-closed loop was proposed and constructed in the real site. The effective thermal conductivity was measured using the test equipment developed by according to the line source model. The simulation results showed that highly efficient thermal conductivity of the grout material could increase the performance of the heat pump system very well. And the new ground heat exchanger showed the increased effective thermal conductivity as the penetration water flow rate(PWFR) was increased. Therefore, the performance improvement of the heat pump system using the proposed ground heat exchanger can be expected.

  • PDF