• Title/Summary/Keyword: Pulse time

Search Result 2,683, Processing Time 0.034 seconds

A Time-Sharing TX/RX Control Technique for the Rejection of Feedback Noise Jamming Interference (피드백 잡음재밍 간섭제거를 위할 시분할 송수신 제어기법)

  • Jeong Un-Seob;Ra Sung-Woong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.12C
    • /
    • pp.1201-1207
    • /
    • 2005
  • When the isolation between transmitter and receiver in Electronic Warfare equipment is not sufficient, the radiated noise jamming signal from the transmitter feeds back into the receiver and interferes with receiving radar pulse signal. Therefore pulse jamming and noise jamming can't be performed together in the same frequency bands. In this paper, we present a time-sharing TX/RX control technique of the switch matrix which inhibits the transmission of noise jamming signal by using the predicted gate of pulse train and also makes the corresponding channel filter operate to receive the radar pulse signal during the predicted gate pulse. This technique was implemented by EPLD and confirmed by experiment. The proposed technique enables the pulse jamming and the noise jamming to be simultaneously executed in multiple jamming environments.

A Cyclic CMOS Time-to-Digital Converter

  • Choi, Jin-Ho;Kim, Ji-Hong
    • Journal of information and communication convergence engineering
    • /
    • v.5 no.2
    • /
    • pp.112-115
    • /
    • 2007
  • A CMOS TDC(time-to-digital converter) is proposed which has a simple cyclic structure. The proposed TDC consists of pulse-shrinking elements, D latches and D flip-flops. The operation is based on pulse-shrinking of the input pulse. The resolution of digital output can be easily improved by increasing the number of the pulse-shrinking elements, D latches and D flip flops. The TDC performance is improved in viewpoints of power consumption and chip area. Simulation results are shown to illustrate the performance of the proposed TDC circuit.

Time-dependent Characteristics of Pulse Modulated rf Plasma (펄스모듈레이션 된 고주파 플라즈마의 시변특성)

  • Lee Sun-Hong;Park Chung-Hoo;Lee Ho-Jun
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.11
    • /
    • pp.566-571
    • /
    • 2004
  • Pulse modulation technique provide additional controling method for electron temperature and density in rf and microwave processing plasma. Transient characteristics of electron density and temperature have been measured in pulse modulated rf inductively coupled argon plasma using simple probe circuit. Electron temperature relaxation is clearly identified in the after glow stage. Controllability of average electron temperature and density depends on the modulation frequency and duty ratio. Numerical calculation of time-dependent electron density and temperature have been performed based on the global model. It has been shown that simple langmuir probe measurement method used for continuous plasma is also applicable to time-dependent measurement of pulse modulated plasma.

Effect of Higher Frequency of Pulse Current on Copper Microstructure (고주파수 펄스 전류가 구리 미세조직에 미치는 영향)

  • Park, Chae-Min;Lee, Hyo-Jong;Lee, Gyu-Hwan
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2015.05a
    • /
    • pp.159-159
    • /
    • 2015
  • 금속의 기계적 강화방법인 결정립미세화의 일종으로 미세한 쌍정을 도입하여 기계적강도를 향상시키면서 전기전도도는 감소시키지 않는 방안으로 nanotwin 구조의 Cu가 보고되고 있다. Nanotwin 구조는 FCC결정구조에서 특정 결정면을 [(111) mirror plane]을 기준으로 정합계면을 유지하면서 원자층의 배열이 역전되는 구조가 수~수십나노 수준의 간격으로 이뤄진 미세조직을 의미한다. 전해도금법을 이용한 nanotwin Cu의 형성방법으로는 pulse 파형을 사용하는데, pulse파형의 on time동안의 높은 전류밀도로 인해 발생한 도금층의 stress가 off time동안에 release되면서 nanotwin구조가 형성되는 것으로 보고되고 있다. Nanotwin형성 조건으로 보고된 pulse 도금 조건은 수에서 수십밀리초의 on time에 duty cycle($t_{on}/(t_{off}+t_{on})$)이 1/100~1/10 수준이다. 본 연구에서는 전기이중층의 이온고갈에 필요한 회복시간인 수에서 수십 밀리초 보다 짧은 시간인 마이크로 초($1{\mu}s$, $10{\mu}s$$100{\mu}s$)의 pulse 전류를 인가하였을 때에 발생하는 구리 도금층의 미세조직의 변화에 대해 알아보고자 한다.

  • PDF

PEO Film Formation Behavior of AZ31 Mg Alloy under Pulse Current (펄스 전류 하에서 AZ31 마그네슘 합금의 플라즈마전해산화 피막의 형성 거동)

  • Moon, Sungmo
    • Journal of the Korean institute of surface engineering
    • /
    • v.55 no.5
    • /
    • pp.292-298
    • /
    • 2022
  • In this study, PEO (plasma electrolytic oxidation) film formation behavior of AZ31 Mg alloy under application of 300 Hz pulse current was studied by the analyses of V-t curve, arc generation behavior, PEO film thickness and morphology of PEO films with treatment time in 0.05 M NaOH + 0.05 M Na2SiO3 + 0.1 M NaF solution. PEO films was observed to grow after 10 s of application of pulse current together with generation of micro-arcs. PEO film grew linearly with treatment time at a growth rate of about 5.58 ㎛/min at 200 mA/cm2 of pulse current but increasing rate of film formation voltage became lowered largely with increasing treatment time after passing about 250 V, suggesting that resistivity of PEO films during micro-arc generation decreases with increasing film formation voltage at more than 250 V.

OPTICAL INVESTIGATION OF THE CRAB PULSAR: SIMULTANEOUS UBVR LIGHT CURVES WITH TIME RESOLUTION OF 3.3 ${\mu}s$ AND SPECTROSCOPY

  • KOMAROVA V. N.;BESKIN G. M.;NEUSTROEV V. V.;PLOKHOTNICHENKO V. L.
    • Journal of The Korean Astronomical Society
    • /
    • v.29 no.spc1
    • /
    • pp.217-218
    • /
    • 1996
  • The results of the Crab pulsar observations with the photometrical MANIA (Multichannel Analysis of Nanosecond Intensity Alterations) complex at the 6-m telescope are presented. More than 12 millions photons in UBVR-bands simultaneously with time resolution of $10^{-7}s$ were detected. Using the original software for search for optical pulsar period, we obtained the light curves of the object with time resolution of about 3.3 ${\mu}s$. Their detailed analysis gives the spectral change during pulse and subpulse, the shape of the pulse peaks, which are plateaus (with the duration of about 50${\mu}s$ for the main pulse), limits for an amplitude of fine temporal (stochastic and regular) structure of pulse and sub pulse and the interpulse space intensity. The results of CCD-spectroscopy of the Crab pulsar show that its summarized spectrum is flat. There are no lines, neither emission nor absorbtion ones. Upper limit for line intensity or depth is $3.5\%$ with the confidence probability of $95\%$.

  • PDF

Influence of first sustain pulse width on equilibrium sustain current in AC-PDP with ramp reset pulse

  • 김성수
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.200-200
    • /
    • 2000
  • AC-PDP의 구동은 인가되는 Pulse의 파형에 의하여 결정된다. 이번 실험은 AC-PDP의 Subfield 파형중 Sustain 부분 첫 번째 Pulse의 폭(Width)에 변화를 주어 다음 Suatain Pulse 기간동안의 전기 광학적 특성을 구속 카메라와 전류의 변화를 통하여 측정하였으며 Sustain Pulse의 Rising Time을 변화 시켜 방전특성을 측정하였다. 이를 통하여 적합한 Sustain 구간의 초기조건을 예측하였으며, 적합한 Sustain Pulse를 찾아가는 실험 방법을 찾고자 하였다.

  • PDF

The Analysis on the Reliability of Measuring Pulse-Respiration Ratio (맥솔(脈率) 측정방법(測定方法)의 신뢰도(信賴度) 분석(分析))

  • Kim, Dong-Hoon;Yang, Dong-Hoon;Huh, Woong;Park, Young-Jae;Park, Young-Bae
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.9 no.2
    • /
    • pp.123-144
    • /
    • 2005
  • Objectives: Pulse-Respiration Ratio has been used for estimating subject's Han-Yeol [寒熱] status since it mentioned in suwen [素問]. In practicing Pulse-Respiration Ratio over 5 means the status of Yeol [熱], Pulse-Respiration Ratio below 3 means the status of Han [寒]. We performed this study to examine the Optimum Standard for Measuring Pulse-Respiration Ratio on the Basis of Repeatability and Reproducibility. Methods: After subject's 5 minutes rest we measured subject's ECG, respiration pattern, EEG, EMG simultaneously. In this research examiner's number is two, subject's number is four, and the number of repeat is two. We calculated Pulse-Respiration Ratio through dividing Respiration cycle average by Pulse cycle average according to each standard including time section, $EEG(relative-{\alpha}$ density, $relative-{\beta}$ density, ${\alpha}/{\beta}$ and EMG. We analyzed these data through Gage R&R study using MINITAB 13.20 program and considered the results of below 30 %R&R and over 4 Number of Distinct Categories to have a significance. Results: 1. In the applying of time standard, Pulse-Respiration Ratio from section 3, 4, 6, 8 had a significant meaning in the aspect of Repeatability and Reproducibility. 2. In the applying of $EEG({\alpha}$ I , ${\beta}$ I , ${\alpha}/{\beta})$, EMG(E I) standard, there was no significant results. 3. In the applying of time standard(section 5, 6, 7), $EEG({\alpha}$ I , ${\beta}$ I , ${\alpha}/{\beta})$ and EMG(E I) standard simultaneously, Pulse-Respiration Ratio from ${\alpha}/{\beta}$ in section 6, ${\beta}$ I in section 8 had a significant meaning in the aspect of Repeatability and Reproducibility. Conclusions: We can suggest the Optimum Standard for Measuring Pulse-Respiration Ratio on the basis of Repeatability and Reproducibility as followings; 1. Pulse-Respiration Ratio Measuring time should be at least 15 minutes. 2. Applying of time(section 6, 8) and $EEG({\beta}$ I, ${\alpha}/{\beta})$ standard simultaneously is recommended considering reliability and validity but more study is needed. 3. EMG(E I) may be helpful to detect the segment of physical rest and exclude artifacts but more study is needed.

  • PDF

Electrical Properties of Molybdenum Metal Deposited by Plasma Enhanced - Atomic Layer Deposition of Variation Condition (다양한 조건의 플라즈마 원자층 증착법으로 증착된 Mo 금속의 전기적 특성)

  • Lim, Taewaen;Chang, Hyo Sik
    • Korean Journal of Materials Research
    • /
    • v.29 no.11
    • /
    • pp.715-719
    • /
    • 2019
  • Molybdenum is a low-resistivity transition metal that can be applied to silicon devices using Si-metal electrode structures and thin film solar cell electrodes. We investigate the deposition of metal Mo thin film by plasma-enhanced atomic layer deposition (PE-ALD). $Mo(CO)_6$ and $H_2$ plasma are used as precursor. $H_2$ plasma is induced between ALD cycles for reduction of $Mo(CO)_6$ and Mo film is deposited on Si substrate at $300^{\circ}C$. Through variation of PE-ALD conditions such as precursor pulse time, plasma pulse time and plasma power, we find that these conditions result in low resistivity. The resistivity is affected by Mo pulse time. We can find the reason through analyzing XPS data according to Mo pulse time. The thickness uniformity is affected by plasma power. The lowest resistivity is $176{\mu}{\Omega}{\cdot}cm$ at $Mo(CO)_6$ pulse time 3s. The thickness uniformity of metal Mo thin film deposited by PE-ALD shows a value of less than 3% below the plasma power of 200 W.

The Prediction of Optimal Pulse Pressure Drop by Empirical Static Model in a Pulsejet Bag Filter (경험모델을 이용한 충격기류식 여과집진기의 적정 탈진압력 예측)

  • Suh, Jeong-Min;Park, Jeong-Ho;Lim, Woo-Taik;Kang, Jum-Soon;Cho, Jae-Hwan
    • Journal of Environmental Science International
    • /
    • v.21 no.5
    • /
    • pp.613-622
    • /
    • 2012
  • A pilot-scale pulse-jet bagfilter was designed, built and tested for the effects of four operating conditions (filtration velocity, inlet dust concentration, pulse pressure, and pulse interval time) on the total system pressure drop, using coke dust from a steel mill factory. Two models were used to predict the total pressure drop according to the operating conditions. These model parameters were estimated from the 180 experimental data points. The empirical model (EM) with filtration velocity, areal density, inlet dust concentration, pulse interval time and pulse pressure shows the best correlation coefficient (R=0.971) between experimental data and model predictions. The empirical model was used as it showed higher correlation coefficient (R=0.971) compared to that of the Multivariate linear regression(MLR) (R=0.961). The minimum pulse pressure predicted by empirical model (EM) was 5kg/$cm^2$.