• Title/Summary/Keyword: Pulse test

Search Result 1,181, Processing Time 0.029 seconds

A Study on 16-Channel LED Driver IC for Full-Color LED Display (풀 컬러 LED 디스플레이용 16-채널 LED 드라이버 IC에 관한 연구)

  • Kim, Sang-Kyu;Lee, Ji-Hoon;Jung, Won-Jae;Jung, Hyo-Bin;Park, Jun-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.9
    • /
    • pp.1275-1282
    • /
    • 2012
  • This paper proposes the 16-channel LED Driver IC for Full color LED display system. The proposed LED driver IC in this paper can draw current independent of temperature and supply voltage in each channel. Current flow in the channel is configurable via an external resistor. LED brightness is adjusted by 12-Bit PWM(Pulse Width Modulation) and 8-Bit DC(Dot Correction). A real-time monitoring of IC temperature ($130^{\circ}C/150^{\circ}C$) and LED status (open/short) is provided by LED driver IC and the user can receive warning and get information on problems. A 16-channel LED driver IC is produced using 0.35 um BCD process and the size is $2.5mm{\times}2.5mm$. In this paper, channel current characteristic and channel current control function were measured in order to verify am embodied 16-channel LED driver IC by producing a single IC test board.

150 kJ Compact Capacitive Pulsed Power System for an Electrothermal Chemical Gun

  • Lee, Byung-Ha;Kim, Jin-Sung;Kim, Seong-Ho;Lee, Young-Hyun;Yang, Kyung-Seung
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.6
    • /
    • pp.971-976
    • /
    • 2012
  • A 150 kJ compact capacitive pulsed power system (CCPPS) capable of delivering electrical energy into an electrothermal chemical (ETC) gun on a vehicle has been studied. The CCPPS provides pulsed electrical energy into a capillary plasma injector which generates plasma of tens of thousands $^{\circ}K$ in temperature and has a nonlinear resistance depending on the current. The design requirements of the CCPPS are as follows: the maximum power of 250 MW, the pulse width of about 0.6 ms, the volume of no more than 0.5 cubic meter, the efficiency of energy transfer over 80 % and the repetition rate of 4~5 times per minute. The constructed CCPPS is composed of four 37.5 kJ capacitor bank modules in parallel to make a trapezoid pulse shape and to satisfy the design requirements. Each module is designed to achieve high reliability, safety, efficiency and energy density to endure severe operating conditions. The results of the performance test on the CCPPS using a 120 mm ETC gun are described.

A Study on Commercial Frequency Source with High Frequency Resonant Type using ZCS (ZCS를 이용한 고주파 공진형 상용주파수 전원에 관한 연구)

  • Kim, Jong-Hae;Kim, Dong-Hui;No, Chae-Gyun;Gu, Tae-Geun;Bae, Sang-Jun;Lee, Bong-Seop
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.8
    • /
    • pp.448-454
    • /
    • 1999
  • This paper describes a new dc-ac inverter system which for achieving sinusoidal ac waveform makes use of parallel loaded high frequency resonant inverter consisting of full bridge. Each one of the pair of switches in the inverter is driven to synchronous output frequency and the other is driven to PWM signal with resonant frequency proportional to magnitude of sine wave. A forced discontinuous conduction mode is used to realize the quasi-sinusoidal pulse in each switching period. Therefore the inverter generates sinusoidal modulated output voltage including carrier frequency that is resonant frequency. Carrier frequency components of modulated output voltage is filtered by low pass filter. Since current through switches is always zero at its turn-on in the proposed inverter, low stress and low switching loss is achieved. Operating characteristics of the proposed system is analyzed in per unit system using computer simulation. The output voltage of if includes low harmonics and it is almost close to sine wave. Also, the theoretical analysis is proved through the experimental test.

  • PDF

Dual Vector Control Strategy for a Three-Stage Hybrid Cascaded Multilevel Inverter

  • Kadir, Mohamad N. Abdul;Mekhilef, Saad;Ping, Hew Wooi
    • Journal of Power Electronics
    • /
    • v.10 no.2
    • /
    • pp.155-164
    • /
    • 2010
  • This paper presents a voltage control algorithm for a hybrid multilevel inverter based on a staged-perception of the inverter voltage vector diagram. The algorithm is applied to control a three-stage eighteen-level hybrid inverter, which has been designed with a maximum number of symmetrical levels. The inverter has a two-level main stage built using a conventional six-switch inverter and medium- and low- voltage three-level stages constructed using cascaded H-bridge cells. The distinctive feature of the proposed algorithm is its ability to avoid the undesirable high switching frequency for high- and medium- voltage stages despite the fact that the inverter's dc sources voltages are selected to maximize the number of levels by state redundancy elimination. The high- and medium- voltage stages switching algorithms have been developed to assure fundamental switching frequency operation of the high voltage stage and not more than few times this frequency for the medium voltage stage. The low voltage stage is controlled using a SVPWM to achieve the reference voltage vector exactly and to set the order of the dominant harmonics. The inverter has been constructed and the control algorithm has been implemented. Test results show that the proposed algorithm achieves the desired features and all of the major hypotheses have been verified.

Characteristics of DC Corona Discharges Caused at the tip of a Needle-shaped Electrode Placed in the Homogeneous Electric Fields (균등전계 중에 놓인 침상 전극의 끝단에서 발생한 직류 코로나방전 특성)

  • Kim, Tae-Ki;Kim, Seung-Min;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.11
    • /
    • pp.74-81
    • /
    • 2015
  • In the measurement of atmospheric static electric field, it is important to know characteristics of corona discharges caused at the tip of test electrode. This paper presents the fundamental data of DC corona discharges that occurred at the tip of a needle-shaped electrode placed in the homogeneous background electric field which simulates the atmospheric static field under thundercloud. The major characteristics of interest for this purpose are the polarity effect of corona discharges and the magnitudes and time intervals of corona current pulses. The experimental set-up consists of the plate-to-plate configuration with a needle-shaped protrusion, DC power supply, and voltage and current measuring devices. As a result of experiments, the polarity dependence of corona pulses is significantly pronounced. The time intervals between successive corona pulses in the negative polarity is much longer than those in the positive polarity. The time intervals for both polarities is drastically decreased as the applied electric field is increased. Also the magnitudes of the positive corona pulses are slightly changed with an increase in applied electric field, but those of the negative corona pulses are linearly increased with increasing the applied electric fields.

On the Development of a Microwave Navigational Aid System Suitable for Small Fishing Boats (마이크로파를 이용한 소형어선용 선위측정방식 개발에 관한 연구)

  • 정세모;이상집
    • Journal of the Korean Institute of Navigation
    • /
    • v.3 no.1
    • /
    • pp.47-77
    • /
    • 1979
  • A microwave Navigational Aid system is suggested suitable for fishing boats too small to be equipped with Radar or Radio-Direction-Finder. The system proposed here is similar to that of Talking-Beacon developed in Japan, but the distinctive modification proposed is that an increase of sixteen times in peak transmitting power, thus an accompanying increase of coverage, is achieved with the same mean transmitting power as that of Japan without sacrificing the clearness of azimuth information, by adopting a pulse repetition modulation instead of pulse width modulation as in Japan system. An experimental land station transmitter of transmitting frequency of 9, 370MHz and of peak power of 35kw with a microwave beam of 1 degree in horizontal width and 7 degrees in vertical width rotating once every three minutes, and also an experimental receiver of 20-dB in sensitivity and of an assumed cost of 100 dollars, operated by a 12 volts battery source are made, and the sail test results are reported showing that a bearing infromation of an accuracy of within two degrees can be obtainable every three minutes at a distance of as far as 24 miles from the transmitter if the transmitter is located as high as 100 meters above sea-level.

  • PDF

Voltammetric Determination of Cobalt(Ⅱ) Using Carbon Paste Electrodes Modified with 1-(2-Pyridylazo)-2-naphthol

  • 배준웅;박유철;이상학;전우성;장혜영
    • Bulletin of the Korean Chemical Society
    • /
    • v.17 no.11
    • /
    • pp.995-999
    • /
    • 1996
  • A method for the determination of cobalt(Ⅱ) by differential pulse voltammetry using a carbon paste electrode constructed by incorporating 1-(2-pyridylazo)-2-naphthol(PAN) into a conventional carbon paste mixture composed of graphite powder and Nujol oil has been developed. Several influencing factors for the determination of cobalt(Ⅱ) were studied in detail and the optimum analytical conditions were found to be as follows: pH, 4.6; composition of electrode, 20%; temperature of deposition, 43 ℃; time of preconcentration, 15 min. Regeneration of the electrode surface for the continuous uses of the electrode was achieved by exposing the carbon paste electrode to an acidic solution. Response of the electrode was reproducible for the uses of five times and the relative standard deviations were 6.7 and 4.6% for 2.0×10-5 M and 4.0×10-6 M cobalt(Ⅱ), respectively. The calibration curve for cobalt(Ⅱ) obtained by differential pulse voltammetry was divided into two linear ranges of 1.7× 10-6-1.3×10-4 M and 2.0×10-7-8.0×10-7 M. The detection limit was estimated to be 1.3×10-7 M. The effects of coexisting ions were also investigated to test the applicability of the proposed method to the determination of cobalt(Ⅱ) in real samples.

The Effect of Breathing Biofeedback Training in the Stress of Nursing Students in Clinical Practice. (호흡바이오피드백 훈련이 간호대학생의 임상실습시 스트레스에 미치는 효과)

  • Kwon Young-Sook;Kim Tae-Hee
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.6 no.2
    • /
    • pp.169-184
    • /
    • 1999
  • The purpose of this study was to identify the effects of breathing biofeedback training on the stress of nursing students in clinical practice. The research design was a nonequivalent control group pretest-posttest design. The subjects of this study were 39 nursing students from the College of Nursing of K University. The study was conducted from July 20 to September 3, 1998. The subjects were assigned to one of two groups : the experimental group (19 students), and the control group (20 students). The breathing biofeedback training was performed 12 times with the experimental group. The level of psychological stress was measured using the State Anxiety Inventory, Profile of Mood State, and Visual Analogue Stress Scale. The level of physiological stress was measured using pulse rate and blood pressure. The data were analyzed using descriptive statistics, $x^2-test$, t-test, and repeated measures of ANOVA. The results of study are as follows : 1) State anxiety scores were not significantly different between the experimental group and the control group after the biofeedback training. 2) Profile of mood state scores were not significantly different between the experimental group and the control group after the biofeedback training. 3) Visual Analogue Stress Scale scores were significantly different between the experimental group and the control group after the biofeedback training(F=11.68, p=0.002). 4) Pulse rates were not significantly different between the experimental group and the control group after the biofeedback training. 5) Systolic blood pressures were significantly different between the experimental group and the control group after the biofeedback training(F=5.44, p=0.025). 6) Diastolic blood pressures were not significantly different between the experimental group and the control group after the biofeedback training. On the basis of the above findings, the following recommendations for further study are made ; 1) Identification of the effects of breathing biofeedback training at times of high stress during clinical practice. 2) Identification fo the effects of stress reduction according to the frequency of the breathing biofeedback training.

  • PDF

The effect of the hand massage on anxiety of the cancer patients receiving radiation treatment (손맛사지가 방사선요법을 받는 암환자의 불안에 미치는 영향)

  • 박미성;서문자
    • Journal of Korean Academy of Nursing
    • /
    • v.25 no.2
    • /
    • pp.316-329
    • /
    • 1995
  • The purpose of this study was to exame the effectiveness of the hand massage as an independent nursing intervention for the cancer patients undergoing radiation therapy. The data were collected with quasiexperimental research design from 40 subjects-20 for experimental group and 20 for control group-of the radiation oncology department of one university hospital in Seoul from January 10th to March 29th, 1994. Subjects agreed to participate in this study and ranged in age from 18 to 82 years with mean age of 52.63. They had insight of their disease and had undergone radiotherapy at least twice. The hand massage developed by Mariah Snyder (1993) based on the Swedish Massage was administered to the experimental group prior to having radiation therapy at the waiting place of radiotherapy room. Hand massage was given to each hand of patient for five minutes once a day. Measurement of the patient's blood pressure, pulse rate, state anxiety and mood were done before and after the administration of hand massage for 5 days. The data were analyzed with paired t-test, t-test an4 the results were summarized as follows ; 1. After administration of the hand massage, the diastolic blood pressure of experimental group was decreased significantly, while the systolic blood pressure and the pulse rate were decreased, but not significantaly. 2. In the experimental group, the level of anxiety was significantaly lower than control group. The mean scores of the difference of the anxiety level after having hand massage was 8.60 in the experimental group and 0.75 in the control group. 3. The difference of the mood scores before and after the massage in the experimental group was decreased significantly. The mean mood score was decreased 4.80 in the experimental group as compared with 2.02 in the control group. 4. The patients after having the hand massage expressed subjectively their feeling of relaxation, well - being and being enjoyable, the significant decreased of physical symptoms and anxiety. The findings summarized that the use of the hand massage for the cancer patient undergoing radiation therapy Produced significant changes in the level of anxiety and relaxation. Therefore it is recommended to use the hand massage as an intervention for the patients.

  • PDF

Experimental Study on the Combustion Stability of Full Scale Rocket Combustor (실물형 액체로켓 연소기의 연소안정성에 대한 시험적인 고찰)

  • Lee Kwang-Jin;Seo Seong-Hyeon;Kang Dong-Hyeuk;Song Ju-Young;Lim Byoung-Jik;Han Yeoung-Min
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.240-246
    • /
    • 2005
  • A series of combustion tests of a 30-tonf-class full scale liquid rocket thrust chamber under development has been carried out to verify its design. The test results revealed decent performance in the aspects of efficiency. The combustion stability is one of the most important parameters of liquid rocket engine in addition to the efficiency. Assessment tests of combustion stability must be accomplished to confirm the possibility of combustion instability due to spontaneous or external disturbances. The combustion stability rating tests of the full scale thrust chamber with temporary baffles made of stainless steel were carried out utilizing pulse guns to estimate combustion stability characteristics. The tests results show highly stable combustion stability characteristics. The outcome acquired from the present experimental study will be used to design an actively cooled baffle that can survive for the life time operation of the thrust chamber.

  • PDF