• Title/Summary/Keyword: Pulse test

Search Result 1,181, Processing Time 0.025 seconds

Dynamic Power Supply Current Testing for Open Defects in CMOS SRAMs

  • Yoon, Doe-Hyun;Kim, Hong-Sik;Kang, Sung-Ho
    • ETRI Journal
    • /
    • v.23 no.2
    • /
    • pp.77-84
    • /
    • 2001
  • The detection of open defects in CMOS SRAM has been a time consuming process. This paper proposes a new dynamic power supply current testing method to detect open defects in CMOS SRAM cells. By monitoring a dynamic current pulse during a transition write operation or a read operation, open defects can be detected. In order to measure the dynamic power supply current pulse, a current monitoring circuit with low hardware overhead is developed. Using the sensor, the new testing method does not require any additional test sequence. The results show that the new test method is very efficient compared with other testing methods. Therefore, the new testing method is very attractive.

  • PDF

The Development of LVI Tester for WInding Deformation Measurement in Power Transformers (변압기의 권선변형 검증을 위한 LVI 시험기 개발)

  • 조국희;김광화;곽희로
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.251-256
    • /
    • 2000
  • The assessment of the condition of a transformer winding which is suspected of having suffered short circuit damage can be difficult. Conventional test such as winding resistance, magnetisation current or insulation resistance will only detect damage if a permanent electrical fault exists. Visual inspection of windings necessitates the removal of oil and in many cases only a very small proportion of the winding can be seen. We describe the characteristics. As the front rise time of recurrent-surge generator pulse less than 1000ns and the peak value of pulse is about 500V, we have the good results of detecting winding deformation in the LVI test of transformers.

  • PDF

Detection and Location of Partial discharge in Transformers Using Logoski coil and Ultrasonic sensor (로고스키 코일과 초음파 센서를 이용한 변압기내 부분방전 탐지 및 위치검출)

  • Kwak, Hee-Ro;Kim, Jae-chul;Kim, Eung-Sang;Han, Min-Koo;Kwan, Tae-Won;Yoon, Young-Beum
    • Proceedings of the KIEE Conference
    • /
    • 1990.07a
    • /
    • pp.279-282
    • /
    • 1990
  • This paper describes an nstrument for the detection and geometric location of partial discharge(PD) sources in transformers. This instrument measures electric current pulses and ultrasonic pulses simultaneously, counts the number of electrical pulse and determines the geometric location of PD in transformers. It was found that there is a relationship between partial discharge magnitude and pulse repetition rate when the applied test voltage and oil temperature were varied. Through the laboratory test using model transformer, it was clarified that this detector could be used, satisfactory for detecting and locating of PD in the transformer.

  • PDF

An Alternative Point-Matching Technique for Fredholm Integral Equations of Second Kind (제2종 Rredholm 적분방정식의 새로운 수식해법)

  • 이직열;김정기
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.22 no.5
    • /
    • pp.83-86
    • /
    • 1985
  • An alternative technique (or the numerical solution of Fredholm integral equations of second kind is presented. The approximate solution is obtained by fitting the data in mixed form at knots in the region of the problem. To decrease the error in the numerical solution, cubic B-spline functions which are twice continuously differentiable at knots are employed as basis function. For a given example, the results of this technique are compared with those of Moment method employing pulse functions for basis function and delta functions for test function and found to br in good agreement.

  • PDF

A Study on the HIC15 Estimating Model Using Frontal Crash Pulses (정면충돌 가속도곡선을 이용한 HIC15 예측모델에 관한 고찰)

  • Ha, Tae-Woong;Lim, Jaemoon
    • Journal of Auto-vehicle Safety Association
    • /
    • v.14 no.1
    • /
    • pp.62-67
    • /
    • 2022
  • This study is to construct the simple estimating model for the HIC15 of the driver dummy using the frontal impact test results. Test results of 9 vehicles of Hyundai Sonata from the MY2002~MY2020 USNCAP are utilized for constructing the linear regression model. The average accelerations extracted from the vehicle crash pulses are handled as the main factors. The average accelerations of 10 ms interval within 0~100 ms are calculated from the crash pulse data of 9 vehicles. The present estimating model of the HIC15 using the average accelerations of 10 ms interval in the 0~80 ms range shows good agreement with the tested value within 2.4% maximum error.

The Effect of Pain Relieving Intervention During Infiltration among Gamma Knife Surgery Patients for Stereotactic Frame Fixation (감마나이프 수술 환자의 정위적 틀 고정을 위한 침윤 마취 시 통증 완화 중재의 효과)

  • Jang, Young Jun;Kim, Hyeon Ok
    • Journal of Korean Academy of Nursing
    • /
    • v.48 no.2
    • /
    • pp.221-231
    • /
    • 2018
  • Purpose: This study aimed to compare the effects of three interventions on pain, blood pressure, and pulse rate during infiltration anesthesia in patients about to undergo gamma knife surgeries. Methods: The three interventions employed in a university-affiliated Hospital in J City, South Korea were as follows: EMLA cream plus Vapocoolant spray (Vapocoolant, n=30), EMLA cream plus 10.0% Lidocaine spray (Lidocaine, n=30), and EMLA cream only (EMLA, n=30). The equivalent control-group pre test - post test study design was used. Pain was assessed subjectively using the numeric rating scale (NRS) and objectively using a Galvanic Skin Response (GSR) tester. NRS scores were assessed after infiltration anesthesia and the GSR was assessed during infiltration anesthesia. Blood pressure and pulse rate were assessed twice: before and after infiltration anesthesia. Data were collected between August 3, 2016 and March 24, 2017. Results: NRS scores after infiltration anesthesia and the GSR during infiltration anesthesia were significantly lower in the Vapocoolant group than in the Lidocaine and EMLA groups (F=13.56, p<.001 and F=14.43, p<.001, respectively). The increase in systolic blood pressure (F=4.77, p=.011) and in pulse rates (F=4.78, p=.011) before and after infiltration anesthesia were significantly smaller in the Vapocoolant group than in the Lidocaine and EMLA groups; however, no significant differences were observed in diastolic blood pressures (F=1.51, p=.227). Conclusion: EMLA cream plus Vapocoolant spray was the most effective intervention to relieve pain and to lower increase in systolic blood pressure and pulse rate caused by infiltration anesthesia for stereotactic frame fixation. Thus, application of Vapocoolant spray in addition to EMLA cream is highly recommended as a nursing intervention for patients undergoing gamma knife surgeries.

An Experimental Study to Secure Electromagnetic Pulse Shielding Performance of Concrete Coated by an Arc Metal Spraying Process (아크 금속 용사 공법에 의해 코팅된 콘크리트의 전자기파 차폐 성능 확보를 위한 실험적 연구)

  • Jang, Jong-Min;Jeong, Hwa-Rang;Lee, Han-Seung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.21 no.6
    • /
    • pp.519-527
    • /
    • 2021
  • In this study, an electromagnetic pulse shielding effect was obtained by applying the arc metal spraying method to the ordinary concrete. For this study, to evaluate the electrical properties in the thickness of the metal sprayed coating, 8 types of metals(Cu, CuAl, CuNi, CuZn, Al, Zn, ZnAl, AlMg) were sprayed as coatings with a thickness of 100, 200 and 500㎛. The electrical conductivity on the surface was measured with a 4-pin probe, and an electromagnetic wave shielding effect test was performed according to KS. Based on the test results, 200 ㎛ was proposed as an optimal metal coating thickness for electromagnetic pulse shielding, and it was thermally sprayed on a 300×300×100mm concrete specimen to analyze the electromagnetic wave shielding performance. However, in the area of adhesion strength, the maximum was 1.11MPa, which was found to be less than 74% of the target performance.

Comparative evaluation of efficacy of external vibrating device and counterstimulation on child's dental anxiety and pain perception during local anesthetic administration: a clinical trial

  • Sahithi, Varada;Saikiran, Kanamarlapudi Venkata;Nunna, Mahesh;Elicherla, Sainath Reddy;Challa, Ramasubba Reddy;Nuvvula, Sivakumar
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.21 no.4
    • /
    • pp.345-355
    • /
    • 2021
  • Background: This study aimed to evaluate the efficacy of external vibrating devices and counterstimulation on a child's dental anxiety, apprehension, and pain perception during local anesthetic administration. Methods: This was a prospective, randomized, parallel-arm, single-blinded interventional, clinical trial. One hundred children aged 4-11 years, requiring pulp therapy or extraction under local anesthesia (LA), were recruited and allocated equally into two groups (1:1) based on the interventions used: Group BD (n = 50) received vibration using a Buzzy® device {MMJ Labs, Atlanta, GE, USA} as a behavior guidance technique; Group CS (n = 50) received counterstimulation for the same technique. Anxiety levels [Venham's Clinical Anxiety Rating Scale (VCARS), Venham Picture Test (VPT), Pulse oximeter {Gibson, Fingertip Pulse Oximeter}, Beijing, China)] were assessed before, during, and after LA administration, while pain perception [Wong-Baker Faces Pain Rating Scale (WBFPS), Visual Analogue Scale (VAS)] was evaluated immediately after injection. Statistical analysis was performed using the Student's t-test to assess the mean difference between the two groups and the repeated measures ANOVA for testing the mean difference in the pulse rates. Statistical significance was set at P < 0.05. Results: Significant differences in mean pulse rate values were observed in both groups. In contrast, the children in the BD group had higher diminution (P < 0.05), whereas the mean VCARS and VPT scores were conspicuous (P < 0.05). Based on the mean WBFPS and VAS scores, delayed pain perception after LA injection was more prominent in the BD group than in the CS group. Conclusion: External vibration using a Buzzy® device is comparatively better than counterstimulation in alleviating needle-associated anxiety in children requiring extraction and pulpectomy.

Comparison of oxygen saturation between no polish nails and self-artificial nails using portable pulse oximeter (휴대용 맥박산소포화도 측정기를 이용한 맨손톱과 셀프 인조손톱의 산소포화도 비교)

  • Su-Min Kim;Kyoung-Youl Lee
    • The Korean Journal of Emergency Medical Services
    • /
    • v.28 no.1
    • /
    • pp.35-46
    • /
    • 2024
  • Purpose: This study aimed to compare the oxygen saturation measured at fingertips with unpolished and self-artificial nails (sticker, tip) using a portable pulse oximeter. Methods: The sample comprised 27 women who had used nail care services. Using a pulse oximeter, oxygen saturation was measured at fingertips with unpolished nails in a stable state. Self-fabricated sticker and tip nails were attached to the right and left hands, respectively, using five nail colors (black, blue, green, purple, and brown). Oxygen saturation was measured at fingertips with self-fabricated nails first in the usual manner and then measured again by rotating the oximeter by 90°. Values of oxygen saturation were compared and analyzed using the Friedman test and Wilcoxon signed-rank test with Bonferroni correction using IBM SPSS 26.0. Results: Oxygen saturation values were significantly different among colors for both sticker nails (p=.036) and tip nails (p=.000), with black self-artificial nails tending to demonstrate lower oxygen saturation. Moreover, oxygen saturation values obtained by measuring the usual way on unpolished nails was significantly different than those obtained by rotating the oximeter by 90° on thumb with sticker (p=.001) and tip nails (p=.001). Conclusion: The findings of this study suggest that oxygen saturation should be measured on other fingers except for thumb instead of removing the self-artificial nails in emergency situations. For patients with black self-artificial nails, is the findings recommend measuring oxygen saturation at other body parts such as toes, earlobes, forehead, etc.

Pulse electric field-excited electron emission from Pb$(Zr_xTi_{1-x})O_3$ ceramics prepared by conventional solid state reaction (고상 반응법에 의해 제조된 Pb$(Zr_xTi_{1-x})O_3$ 세라믹스에서 펄스 전계에 의한 전자 방출)

  • Kwak, Sang-Hee;Kim, Tae-Heui;Park, Kyung-Bong;Kim, Chang-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1867-1869
    • /
    • 1999
  • Pulse electric field induced electron emission from ferroelectrics has been studied with Pb$(Zr_xTi_{1-x})O_3$ ceramics with varying Zr/Ti ratio from 35/65 to 65/35, Electron emission was proved to be concentrated on the electrode edge by emission profile test and emission capture photographs. The 65/35 composition showed largest emission charge in lowest field and lowest emission threshold field. The emission characteristics are closely dependent on their ferroelectric properties in hysteresis curve. Electron emission charge increases with the polarization charge and emission threshold voltage is dependent on coercive field regardless of their composition. But dielectric constant has little relation with emission property. Electron emission charge increases exponentially with pulse electric field irrespective of composition. On the assumption that the surface potential is linear with the pulse electric field, electron emission can be regarded as a field emission at the electrode edge using Fowler-Nordheim plot of ln$(Q_e/E_{fe})$ to $1/E_{fe}$.

  • PDF