• Title/Summary/Keyword: Pulse test

Search Result 1,181, Processing Time 0.023 seconds

A Study of X-ray Output for Diagnostic X-ray Equipment (진단용 X선 발생 장치의 X선 출력에 관한 연구)

  • Ko, Shin-Gwan;Ahn, Bong-Seon;Jang, Sang-Sup;Choi, Jong-Woon;Shin, Young-Soon
    • Journal of radiological science and technology
    • /
    • v.18 no.2
    • /
    • pp.61-73
    • /
    • 1995
  • For the managements of the diagnostic X-ray equipments, the authors examined the output of single phase rectification assembly, Three phase rectification assembly and serial radiographic appartus, and got the following conclusions. 1. When the tube voltages in X-ray control panels ware compared to the measured values on the kVp pulse meter, only little differences were detected in all the X-ray equipments. And most of the equipments were all well managed within the internationally permitted limits, excepting the 12.02 % error at 120 kVp in three phase rectifying assembly. 2. As for the X-ray qualities affecting the X-ray images, the serial radiographic apparatus showed excellence, while the single phase rectification assembly were somewhat inferior to the others only maining the internationally recommended limits. 3. The tube voltage ranges where the X-ray output showed excellence were $100{\sim}200\;mA$ in serial radiographic apparatus, $200{\sim}350\;mA$ in three phase rectification assembly and $350{\sim}400\;mA$ in single phase rectification assembly respectively. 4. In the repeatability test of the X-ray equipments, CVs were in the range of $0.0029{\sim}0.049$, which is within the HEW or KS standards. Consequently all the equipments are thought to be well-manage. 5. This study on characteristics and output of the X-ray equipments was accomplished within a limited short time. Long-time researches on the function managements for the X-ray equipments should be followed along with the periodical checking the output for reduction of X-ray exposures to the patients or radio-technologists, and for maintanance and prediction of trouble of the equipments.

  • PDF

Fracture Behavior of Pre-cracked AISI 4130 Specimens by Means of Acoustic Emission and Ultrasonic C-scan Measurements (음향방출과 초음파 C-scan을 이용한 AISI 4130 균열재의 파괴거동 연구)

  • Ong, J.W.;Moon, S.I.;Jeong, H.J.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.13 no.3
    • /
    • pp.7-13
    • /
    • 1993
  • Fracture behavior of pre-cracked compact tension specimens made of AISI 4130 steel was investigated using acoustic emission (AE) and ultrasonic C-scan measurements. While each specimen was loaded up to a certain level, various acoustic emission parameters were recorded together with the crack opening displacement (COD). An elastic-plastic finite element analysis was performed to calculate COD and the damage (plastic) zone size ahead of crack tip. Ultrasonic C-scans, in a pulse-echo, immersion mode, were done for mapping the damage zone size. The agreement between the finite element results and the measured COD was satisfactory. Based on AE results, the test specimens were found to show ductile behavior. The slope of the total ringdown counts vs. COD curve was useful to determine the crack initiation. The preliminary C-scan images showed evidence of changes in the amplitude of ultrasonic signal in the damaged region, and the shape and size of the damage zone matched qualitatively with the finite element results. A further work on the damage zone sizing was also pointed out.

  • PDF

Nuclear Remodeling and In Vitro Development Following Somatic Cell Nuclear Transfer in Swine

  • Yoon Jong-Taek;Kim Yong-Yeup;Lee Jong-Wan;Min Kwan-Sil;Hwang Seongsoo
    • Reproductive and Developmental Biology
    • /
    • v.28 no.4
    • /
    • pp.241-245
    • /
    • 2004
  • This study was conducted to investigate nuclear remodeling and developmental rate following nuclear transfer of fetal fibroblast cells, ear skin cells and oviduct epithelial cells into porcine recipient oocytes. To test par-thenogenetic activation, oocytes were treated with a 6-dimethylaminopurine (6-DMAP), a single DC-pulse (DC), calcium ionomycin (ionomycin), DC+6-DMAP and ionomycin + 6-DMAP after in vitro maturation. For nuclear transfer, in vitro matured oocytes were enucleated, and donor cells were transferred into oocytes. Cloned embryos were fused and stimulated with 6-DMAP for 4 h and cultured in vitro for 6 days. Among treatments for parthenogenesis, the activation rate of DC +6-DMAP treatment was significantly higher than that of single treatment roups (p<0.01), except for DC treatment group. However, the difference was not significant in activation rate compared to other complex treatment groups. Nuclear swelling of the cloned embryos was initiated at 60 min after stimulation and increased afterwards. Fusion rates were not different among different donor cells. Cleavage rates of DC treatment groups were significantly higher than those of DC+6-DMAP treatment groups (p<0.05) in case that fetal fibroblast and ear cells were used for nuclear donor. The cloned embryos from developed to blastocysts in oviduct epithelial cell nuclear transfer with DC+6-DMAP treatment was significantly higher compared to those with DC only treatment (p<0.05). However, no blastocyst was developed from nuclear transfer of fetal fibroblast and ear cells regardless of activation treatments. Based on these results, a proper activation stimulation may be necessary to increase the activation rate and the development to blastocyst in cloned porcine embryos.

An Optical Fiber Perimeter Guard System Using OTDRs (OTDR을 이용한 광섬유 외곽경비시스템에 관한 연구)

  • Chang, Jin-Hyeon;Lee, Yong-Cheol;Shin, Dong-Ho;Oh, Sang-Gun;Lee, Jong-Youn;Jung, Jin-Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.12B
    • /
    • pp.1236-1243
    • /
    • 2010
  • The perimeter defense system was created and its characteristics were evaluated. It was designed to utilize the fiber sensing device, namely OTDR(Optical Time Domain Reflectometer) which has been used for the maintenance of the optical communication network. An OTDR was constituted by a pulse laser with the nature of 1310nm, +15dBm for the observation of 400 meter optical fence. The high-speed 32-bit processor(S3C2440) has applied to MPU(Main Processor Unit) which helps to improve the performance of OTDR algorithms. Consequently, the maximum error was 0.84 meter on the performance test of the 10km monitoring and the pass criteria of ${\pm}1m$ satisfied in all the sections. The alarm delay time was under 3 sec after detecting the disorder. For the case of secondary trespassing after primary trespassing, the optical switch was installed in OTDR to monitor the secondary trespassing and to measure the multi-point detection. Therefore, this paper shows that the detections of secondary trespassing and multi-point is possible by means of optical switch.

The detection of cavitation in hydraulic machines by use of ultrasonic signal analysis

  • Gruber, P.;Farhat, M.;Odermatt, P.;Etterlin, M.;Lerch, T.;Frei, M.
    • International Journal of Fluid Machinery and Systems
    • /
    • v.8 no.4
    • /
    • pp.264-273
    • /
    • 2015
  • This presentation describes an experimental approach for the detection of cavitation in hydraulic machines by use of ultrasonic signal analysis. Instead of using the high frequency pulses (typically 1MHz) only for transit time measurement different other signal characteristics are extracted from the individual signals and its correlation function with reference signals in order to gain knowledge of the water conditions. As the pulse repetition rate is high (typically 100Hz), statistical parameters can be extracted of the signals. The idea is to find patterns in the parameters by a classifier that can distinguish between the different water states. This classification scheme has been applied to different cavitation sections: a sphere in a water flow in circular tube at the HSLU in Lucerne, a NACA profile in a cavitation tunnel and two Francis model test turbines all at LMH in Lausanne. From the signal raw data several statistical parameters in the time and frequency domain as well as from the correlation function with reference signals have been determined. As classifiers two methods were used: neural feed forward networks and decision trees. For both classification methods realizations with lowest complexity as possible are of special interest. It is shown that two to three signal characteristics, two from the signal itself and one from the correlation function are in many cases sufficient for the detection capability. The final goal is to combine these results with operating point, vibration, acoustic emission and dynamic pressure information such that a distinction between dangerous and not dangerous cavitation is possible.

Physical and Mechanical Properties of Expanded Polystyrene Bead Concrete (팽창 폴리스틸렌 비드 콘크리트의 물리.역학적 특성)

  • 민정기;김성완;성찬용
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.38 no.6
    • /
    • pp.83-95
    • /
    • 1996
  • The normal cement concrete is widely used material to build the construction recently, but it has a fault to increase the dead load on account of its unit weight is large compared with strength. So, main purpose of this study was to establish the physical and mechanical properties of lightweight concrete using expanded polystyrene bead on fine aggregate and natural gravel, expanded clay and pumice stone on coarse aggregate. The test rusults of this study are summarized as follows; 1. The water-cement ratio of concrete using pumice stone was larger than that of the concrete using natural gravel and expanded clay. 2. The unit weights of concrete using pumice stone and expanded caly were shown less than 1,000g/$m^3$. 3. The compressive strengths of all types were shown less than 60kg/$cm^2$, tensile and bending strengths were shown less than l3kg/$cm^2$ and 3lkg/$cm^2$$^2$, respectively. 4. The pulse velocity of concrete was shown similar with using natural gravel and pumice stone, and shown the lowest using pumice stone. 5. The dynamic modulus of elasticity of concrete was shown considerably smaller, and shown the lowest using pumice stone. 6. The static modulus of elasticity of concrete using expanded clay and pumice stone were shown considerably smaller, and shown 22% ~29% as compared with the dynamic modulus of elasticity. 7. The stress-strain curves of concrete were shown similar, generally. And the curves were repeated at short intervals increase and decreased irregularly.

  • PDF

Sleep Apnea Detection Using a Piezo Snoring Sensor: A Pilot study (코골이용 압전센서를 이용한 수면무호흡 검출에 관한 예비 연구)

  • Urtnasan, Erdenebayar;Lee, Hyo-Ki;Kim, Hojoong;Lee, Kyoung-Joung
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.4
    • /
    • pp.75-80
    • /
    • 2014
  • This paper proposed a method that can automatically classify sleep apnea by using features extracted from pulse rate variability(PRV) signals induced from piezo snoring sensor for patients with obstructive sleep apnea(OSA). We have extracted eight features(NN, SDNN, RMSSD, NN10, NN50, LF, HF and LF/HF ratio) based on time and frequency analyses of PRV. Sleep apnea was classified by a linear discriminant analysis(LDA). A performance was evaluated using snore recordings from 13 patients with OSA (ages: $54.5{\pm}10.5$ years, body mass index: $26.3{\pm}2.5kg/m^2$, apnea-hypopnea index: $19.2{\pm}6.0/h$). The sensitivity and specificity were $78.9{\pm}0.9%$ and $78.9{\pm}0.9%$ for training set and $77.7{\pm}10.9%$ and $79.0{\pm}2.8%$ for test set, respectively. Our study demonstrated the feasibility of implementing a piezo snoring sensor based on a portable device as a simple and cost-effective solution for contributing to the OSA screening.

The Kinetics of Hyperpolarization Activated Current$(i_f)$ in Sinoatrial Node of the Rabbit (토끼 동방결결에서 Pacemaker전류(과분극에 의해 활성화되는 내향전류, $i_f$)의 동력학적 특성에 관한 연구)

  • Earm, Yung-E
    • The Korean Journal of Physiology
    • /
    • v.17 no.1
    • /
    • pp.1-11
    • /
    • 1983
  • 1) The two microelectrode method was used to voltage clamp small preparations of rabbit sinoatrial node. The kinetics of hyperpolarization activated inward current, $i_f$ were analysed. 2) The hrperpolarization pulses activated $i_f$ current in the presence of $10^{-7}g/ml$ TTX and 2 mM $Mn^{2+}$. The activation range was in between -45 mV to -75 mV. The current magnitude was increased and time course was faster by strong hyperpolarization pulses. 3) Standard envelope tests indicated that this current is exponentially controlled by single gate. 4) Semilogarithmic plot of $i_f$ activation versus time was found to be linear in the activation range. The decrease in current magnitude and the shifts in activation curve and rate constants curve to the hyperpolarizing direction were obtained with $Ba^{2+}$, indicating that $Ba^{2+}$ shifts the voltage dependence of the gating kinetics, were partially reversed by 24 mM $K^+$.

  • PDF

Effects of Hand Massage with Nail Art on Depression, Self-esteem, and Vital signs of Elderly Women living in a Nursing Home (손마사지를 병행한 네일아트가 시설 여성 노인의 우울, 자존감 및 활력증상에 미치는 효과)

  • Kim, Joo Hyun;Hyun, Hye Jin;Kang, So Yean;Nam, Hye Ri;Shin, Mi Jin;Lee, Hyun Jung;Chae, Young Ran
    • Journal of Korean Biological Nursing Science
    • /
    • v.18 no.3
    • /
    • pp.169-175
    • /
    • 2016
  • Purpose: The aim of this study was to examine the effects of hand massage with nail art on depression, self-esteem and vital signs of elderly women. Methods: The research design was one group pre and post test experimental design. Data were collected from December 7 to December 14, 2015. All participants had hand massage with nail art for 10 minutes. Depression, self-esteem and vital signs were measured before, immediately after the hand massage with nail art and one week later. Data were analyzed using descriptive statistics and repeated measures ANOVA with SPSS/Win 12.0 Program. Results: Depression (F=30.80, p<.001), self-esteem (F=60.02, p<.000), diastolic pressure (F=29.56, p<.001) and body temperature (F=13.87, p<.001) were significantly different compared to pre-study values. Systolic pressure (F=3.85, p=.059) and pulse rate (F=0.32, p=.576) had no significant difference compared to pre-study values. Conclusion: The findings of this research show that hand massage with nail art has positive effects on decreasing depression and improving self-esteem for senior women who chose nail polish colour by themselves.

The Effect of the 3.3.5.5 Walking Club Program to Health Promotion of the Elderly (3.3.5.5 워킹 프로그램이 노인의 건강증진에 미치는 효과)

  • Min, Soon;Im, Wook-Bin;Kim, Young-Jae;Jung, Young-Ju;Kim, Kyung-Sook;Na, Song-Sook
    • Journal of Korean Biological Nursing Science
    • /
    • v.10 no.1
    • /
    • pp.96-104
    • /
    • 2008
  • Purpose: We had executed the 3 3 5 5 walking club program for 12 weeks for one hour three times per week to evaluate the effect of the program on health of the elderly. Methods: A pre and post measurement tool of the program was applied to measure obesity, rate of body fat, blood pressure, vital capacity, standard vital capacity, intake capacity of maximum oxygen, grasping power, reaction of whole body, pulse, body mass index (BMI), total bodily score, age of bodily strength, age of health. Data collected from this tool was analyzed by SPSS in paired t-test. Results: The 3 3 5 5 walking club program has affected the weight control of the participants. The participants of 3 3 5 5 walking club program reduced their weight from 61.7 kg to 61.25 kg, rate of body fat from 21.89 kg to 21.22 kg, standard vital capacity from 2,393.56 ml to 2,380.44 ml, reaction of whole body from 475.38 msec to 439.33 msec, and increased grasping power from 22.06 to 23.16 ml (p<.05), total bodily score 68.91 points to 71.38 points significantly (p<.05). Conclusion: The result indicated that the 3.3.5.5 Walking club program has an positive effect on improving health care of the elderly without special exercise tools.

  • PDF