• Title/Summary/Keyword: Pulse reaction

검색결과 210건 처리시간 0.028초

EMLA크림 도포가 소아암환자의 피하매몰 중심정맥포트 바늘삽입 시 통증인지와 통증반응에 미치는 영향 (Effects of EMLA Cream Application on Pain Perception and Pain Response of Children with Cancer During Implanted Venous Access Port Needle Insertion)

  • 서현영;김영혜
    • Child Health Nursing Research
    • /
    • 제22권1호
    • /
    • pp.21-28
    • /
    • 2016
  • Purpose: The purpose of this study was to identify effects of EMLA (Eutectic Mixture of Local Anesthetics) cream application on pain perception and pain response during insertion of implanted venous access port needle in children with cancer. Methods: From December 2010 to August 2011, at U university hospital, 20 patients scheduled for implanted venous access port needle insertion were recruited, and randomly assigned to receive either EMLA or a placebo cream 1 hour before the implanted venous access port needle insertion. While conducting needle insertion, changes in pulse and oxygen saturation on the pulse oxymeter monitor were measured and pain behavior reaction was also measured during needle insertion in the treatment room. After conducting needle insertion, self-reported pain reaction, and mothers' perception of the children's pain reaction were measured. Collected data were statistically processed using SPSS version 17.0 for Windows, and analyzed using descriptive statistics, t-test. Results: Children's self-reported degree of pain, degree of pain as perceived by mothers and pain behavior reaction decreased significantly in the EMLA application group compared with the placebo group. Conclusion: Findings indicate that application of EMLA cream is effective in relieving pain in these children during implanted venous access port needle insertion.

다종의 Pulse Oximeter에서 측정된 산소 분압도의 차이와 상호 비교 결과에 대한 보고 (COMPARATIVE STUDY OF SEVERAL TYPE PULSE OXIMETER AND OXYGEN SATURATION EXTRACTED FROM THEM)

  • 유승훈;김응학;권순원;김종수
    • 대한소아치과학회지
    • /
    • 제27권4호
    • /
    • pp.494-498
    • /
    • 2000
  • 진정요법하의 치과진료에서 환자의 상태를 지속적으로 감시하는 것은 매우 중요하다. 여러 방법 중 가장 널리 사용되는 것 중 Pulse Oximeter가 있다. Pulse Oximeter는 비침습적 방법으로 계속해서 동맥혈액의 산소포화도를 측정할 수 있도록 고안된 장치로서 기기에 나타나는 산소포화도$(SpO_2)$는 실제로 측정한 동맥혈액의 산소포화도$(SaO_2)$와 거의 일치하는 것으로 알려져 있다. 본 진료실에 있는 세종류의 Pulse Oximeter를 이용하여 한 환자에게 동시에 두 개의 기기를 적용하였을 경우, 산출값을 상호 비교한 결과, 짧은(3회) 맥박수를 평균하는 기기가 낮은값이 나왔으며, 다른 두개의 Pulse Oximeter와 유의한 차이가 있는 것으로 밝혀졌다. 짧은 맥박수를 평균하는 기기는 반응이 빠르나, 산소포화도의 값이 작게 산출되고, 외부의 신호에 더욱 민감하여, 오류가 존재할 가능성 또한 높다. 기기의 특성을 알아, 술자는 적절한 기기를 선택하는 것이 중요하다.

  • PDF

프로판 펄스 주입에 의한 백금주석촉매의 탈수소반응 특성 연구 (Study of the Dehydrogenation Characteristics of Pt-Sn Catalysts by Propane Pulse Injection)

  • 고형림;정재원;최이선
    • Korean Chemical Engineering Research
    • /
    • 제57권4호
    • /
    • pp.575-583
    • /
    • 2019
  • 반응물의 펄스주입에 의한 촉매반응결과는 코크가 많은 반응의 경우 초기반응특성을 연구하는데 유용하다. 프로판의 펄스주입으로 알루미나에 담지된 백금주석촉매의 탈수소 반응 특성을 연구하였다. 프로판 주입전 촉매의 환원을 $550^{\circ}C$에서 한 경우, 환원시간이 1시간인 경우 프로필렌의 수율이 최대가 되었다. PtSn (4.5)촉매를 사용하고, 프로판 펄스 주입에 의해 짧은 접촉시간을 모사한 경우 코크의 양이 매우 적었음을 Raman분석으로 알 수 있었다. 백금의 분산도를 다르게 하기위하여 PtSn (4.5)촉매를 수소로 $900^{\circ}C$에서 신터링 후 공기-재분산시의 온도를 다르게 처리한 후, 프로판 펄스 주입한 결과 공기처리 온도가 $600^{\circ}C$ 일 때 프로판의 전환율과 수율은 가장 높았다. 공기-재분산의 온도가 낮을수록 선택도는 높았다. 백금촉매에 주석함량이 증가함에 따라 프로판 전환율은 낮아졌지만, 프로필렌으로의 선택도는 높아져서, 수율은 증가하였다. 이로부터 주석을 첨가한 백금촉매는 코크의 영향이 적은 반응초기부터 백금촉매보다 활성이 낮다는 것을 알 수 있다. 프로판 펄스주입에 의한 탈수소반응은 COx의 생성에 의해 연속주입에 의한 결과보다 높은 전환율을 보이고, 코크의 양이 매우 적은 특징을 보이고 있다. COx의 생성에 의한 선택도 하락은 환원온도와 시간을 증가시키면 줄일 수 있다.

표면화학 반응을 통한 Laser-Ablated 알루미늄의 Detonation 현상 연구 (Detonation Initiation via Surface Chemical Reaction of Laser-Ablated Aluminum Sample)

  • 김창환;여재익
    • 대한기계학회논문집B
    • /
    • 제36권2호
    • /
    • pp.197-204
    • /
    • 2012
  • 본 논문에서는 공기 중에서 높은 레이저 복사 조도에 따른 효과에 의해 발생되는 금속 플라즈마의 발달 과정에 대하여 레이저 펄스가 끝나는 이후로 쉐도우그래프(Shadowgraph) 가시화 방법을 이용하여 현상을 연구하였다. 따라서 레이저에 의한 데토네이션의 발생과 이를 일으키는 연소 과정 대한 연구가 진행되었다. 본 논문의 가장 중요한 점들은 높은 레이저 에너지에 의해 삭마 된 기체 상태의 알루미늄과 공기로부터의 산소와의 화학 반응의 진행을 관측했을 뿐만 아니라, 화학 반응 최종 산화물을 X선 회절 분석법(X-Ray Diffraction)을 통해 관측한 것이다. 그리고 레이저를 통해 유도된 화학적 반응 파와 공기 중에서의 알루미늄 분진 폭발의 데토네이션과의 양적인 평가를 유도하였다. 이러한 연구는 덩어리 상태의 금속 샘플에서 공기 중의 산소를 이용하여 데토네이션을 발생시키는 새로운 방법을 제시할 것으로 여겨진다.

습식-펄스방전 복합시스템의 황산화물 및 질소산화물 제거성능 특성 (SOx and NOx removal performance by a wet-pulse discharge complex system)

  • 박현진;이환영;박문례;노학재;유정구;한방우;홍기정
    • 한국입자에어로졸학회지
    • /
    • 제15권1호
    • /
    • pp.1-13
    • /
    • 2019
  • Current desulfurization and denitrification technologies have reached a considerable level in terms of reduction efficiency. However, when compared with the simultaneous reduction technology, the individual reduction technologies have issues such as economic disadvantages due to the difficulty to scale-up apparatus, secondary pollution from wastewater/waste during the treatment process, requirement of large facilities for post-treatment, and increased installation costs. Therefore, it is necessary to enable practical application of simultaneous SOx and NOx treatment technologies to remove two or more contaminants in one process. The present study analyzes a technology capable of maintaining simultaneous treatment of SOx and NOx even at low temperatures due to the electrochemically generated strong oxidation of the wet-pulse complex system. This system also reduces unreacted residual gas and secondary products through the wet scrubbing process. It addresses common problems of the existing fuel gas treatment methods such as SDR, SCR, and activated carbon adsorption (i.e., low treatment efficiency, expensive maintenance cost, large installation area, and energy loss). Experiments were performed with varying variables such as pulse voltage, reaction temperature, chemicals and additives ratios, liquid/gas ratio, structure of the aeration cleaning nozzle, and gas inlet concentration. The performance of individual and complex processes using the wet-pulse discharge reaction were analyzed and compared.

타코펄스 불균일성 보정이 포함된 펄스간 시간 측정방법 (Elapsed-time Method With Tacho Pulse Non-uniformity Correction)

  • 손준원
    • 한국항공우주학회지
    • /
    • 제50권4호
    • /
    • pp.269-275
    • /
    • 2022
  • 펄스간 시간측정방법은 이상적인 조건에서는 정확한 반작용휠 속도를 측정할 수 있지만, 실제로는 타코펄스 불균일성 때문에 측정속도 오차가 존재한다. 본 연구에서는 불균일성을 극복하는 방법을 살펴본다. 우선 휠을 특정한 속도로 회전시켜서 타코펄스 불균일성을 측정하는 방법을 소개한다. 이렇게 획득된 불균일성 정보를 이용하여 실시간으로 측정오차를 보정하는 방법을 제안한다. 해당 방법은 펄스간 시간 측정방법의 카운트와 사전 측정된 불균일 정보로부터 속도 후보군을 계산하고, 이중에서 실제속도와 가장 가까운 값을 선택한다. 시뮬레이션을 통해서 제안된 방법이 타코펄스 불균일성을 극복하고 정확한 속도를 측정하며 빠른 휠속도 제어도 가능함을 보인다.

소음이 백서 혈압 및 맥박수에 미치는 영향 (Changes of the Blood Pressure and the Pulse Rate of the Rat after the Noise Exposure)

  • 노재훈;신동천;차봉석;문영한
    • Journal of Preventive Medicine and Public Health
    • /
    • 제17권1호
    • /
    • pp.239-243
    • /
    • 1984
  • The vascular reaction such as the indirect blood pressure and the pulse rate of the tail to the noise were examined in 8 naive Sprague-Dawley rats of both sexes. The sounds used in the experiment were 1KHz and 4 KHz, 95dB pure tone generated by Nagashima Audiometry. The indirect blood pressure and the pulse rate were checked at the rat tail by Polygraph at 5 minutes interval. The results were as follows: 1. The blood pressure and the pulse rate increased maximally 5 minutes after the exposure to both sounds. 2. The blood pressure and the pulse rate returned normal range within 20 minutes after the exposure of both sounds. 3. The increment of the blood pressure and the pulse rate was greater after the sound of 4KHz than after that of 1KHz, but it wasn't statistically significant.

  • PDF

Partial Oxidation of Methane over Ni/SiO2

  • Roh, Hyun-Seog;Dong, Wen-Sheng;Jun, Ki-Won;Liu, Zhong-Wen;Park, Sang-Eon;Oh, Young-Sam
    • Bulletin of the Korean Chemical Society
    • /
    • 제23권5호
    • /
    • pp.669-673
    • /
    • 2002
  • Ni catalyst (Ni: 15 wt%) supported on precalcined SiO2 has been investigated in reforming reactions of methane to synthesis gas. The catalyst exhibited fairly good activity and stability in partial oxidation of methane (POM), whereas it deactivated in steam reforming of methane (SRM). Pulse reaction results of CH4, O2, and CH4/O2 revealed that Ni/SiO2 has high capability to dissociate methane. The results also revealed that both CH4 and O2 are activated on the surface of metallic Ni, and then surface carbon species react with adsorbed oxygen to produce CO and CO2 depending on the bond strength of the oxygen species on the catalyst surface.

Electrochemical Study on the Coumarin Derivatives

  • Kim, Il Kwang;Chun, Hyun Ja;Paik, Soon Ok;Park, Sung Woo
    • 분석과학
    • /
    • 제8권4호
    • /
    • pp.655-661
    • /
    • 1995
  • The electrochemical reduction of coumarin derivatives in 0.1M TEAP acetonitrile solution was investigated by the direct current, differential pulse polarography, cyclic voltammetry and controlled potential coulometry. The electrochemical reduction of 7-acetoxy-4-bromomethyl-coumarin(ABMC) was proceeded as an irreversible three steps(-0.58, -1.63 and -2.25 volts) of electrochemical transfer before chemical reaction. The solution color turned to yellow after the carboxyl group was reduced at 2nd step(-1.63 volts vs. Ag-AgCl) and the change in color was independant to the bromo group. Upon the basis of the results on the products analysis and the interpretaton of polarograms, a possible electrochemical reaction mechanism was suggested.

  • PDF

Vibration control of a framed structure by an air-pulse actuator

  • Fujimoto, T.;Fengying, Cao;Mori, Y.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.152.3-152
    • /
    • 2001
  • This paper describes an application of an air-pulse actuator for vibration control of a framed structure. Dynamic characteristics of the prototype actuator that utilizes an air-jet reaction force pulsated by an electromagnetic valve were investigated to use it as a control actuator. Using a control law based on the sliding mode control theory, experiments of the vibration control were carried out. The experimental results verified the validity of the actuator performance.

  • PDF