• 제목/요약/키워드: Pulse power

검색결과 2,648건 처리시간 0.035초

Resonant Pulse Power Converter with a Self-Switching Technique

  • Kim, Hyeok-Jin;Chung, Gyo-Bum;Cho, Jae-Ho
    • Journal of Power Electronics
    • /
    • 제10권6호
    • /
    • pp.784-791
    • /
    • 2010
  • In this paper, a resonant pulse power converter (RPPC) is proposed. The proposed RPPC transfers the pulse-shape power from a DC source to a load periodically. The RPPC consists of a resonant circuit and a resonant pulse converter driven by a self-switching circuit. Depending on the magnitude difference between the input and output voltages, the operations of the RPPC are divided into 4 modes; boost mode, hybrid mode, direct mode and cut-off mode, respectively. The main switch of the RPPC turns on in the ZCS condition and off in the ZVS condition spontaneously. The operational principles of a RPPC using the self-switching technique are analyzed and verified in experiments. An example of a RPPC application is demonstrated in the area of thermoelectric energy harvesting.

펄스 변조 및 전원 스위칭 방법을 혼용한 X-대역 50 W Pulsed SSPA 설계 및 제작 (Design and Fabrication of X-Band 50 W Pulsed SSPA Using Pulse Modulation and Power Supply Switching Method)

  • 김효종;윤명한;장필식;김완식;이종욱
    • 한국전자파학회논문지
    • /
    • 제22권4호
    • /
    • pp.440-446
    • /
    • 2011
  • 본 논문에서는 레이더 시스템에 적용이 가능한 50 W 출력을 가지는 X-대역 pulsed SSPA(Solid State Power Amplifier)를 설계 및 제작하였다. SSPA를 펄스 모드로 동작시키는 방법으로 펄스 변조 방법과 전원 스위칭 방법을 혼용한 방법을 제안하였다. SSPA는 구동 증폭기, 고출력 증폭기, 펄스 변조기로 구성되며, 충분한 이득과 출력 크기를 얻기 위해 25 W GaAs FET 4개를 병렬 구조로 구성하였다. 측정 결과 1.12 GHz 대역폭에서 출력 50 W, 이득 44.2 dB의 성능을 가졌다. 또한, pulse droop은 1 dB 이하로 설계 목표를 만족하였으며, 12.45 ns 이하의 상승/하강 시간을 가졌다. 제작된 X-대역 pulsed SSPA 크기는 $150{\times}105{\times}30\;mm^3$로 매우 작은 크기를 가졌다.

Passively Q-switched Erbium Doped All-fiber Laser with High Pulse Energy Based on Evanescent Field Interaction with Single-walled Carbon Nanotube Saturable Absorber

  • Jeong, Hwanseong;Yeom, Dong-Il
    • Current Optics and Photonics
    • /
    • 제1권3호
    • /
    • pp.203-206
    • /
    • 2017
  • We report a passive Q-switching of an all-fiber erbium-doped fiber laser delivering high pulse energy by using a high quality single-walled carbon nanotube saturable absorber (SWCNT-SA). A side-polished fiber coated with the SWCNT is employed as an in-line SA for evanescent wave interaction between the incident light and the SWCNT. This lateral interaction scheme enables a stable Q-switched fiber laser that generates high pulse energy. The central wavelength of the Q-switched pulse laser was measured as 1560 nm. A repetition rate frequency of the Q-switched laser is controlled from 78 kHz to 190 kHz by adjusting the applied pump power from 124 mW to 790 mW. The variation of pulse energy from 51 nJ to 270 nJ is also observed as increasing the pump power. The pulse energy of 270 nJ achieved at maximum pump power is 3 times larger than those reported in Q-switched all-fiber lasers using a SWCNT-SA. The tunable behaviors in pulse duration, pulse repetition rate, and pulse energy as a function of pump power are reported, and are well matched with theoretical expectation.

PID 제어기법을 이용한 펄스 레이저 출력 안정화에 관한 연구 (Pulse Laser Power Stabilization Using PID Control Method)

  • 류훈철;곽승우;강동원;김경식;한재원
    • 한국레이저가공학회지
    • /
    • 제9권2호
    • /
    • pp.17-22
    • /
    • 2006
  • In this study, PID control method was applied to decrease the power fluctuation of the pulse laser which is one of the major processing variables in laser machining process. To stabilize the power fluctuation of the pulse laser, we averaged 10 pulse outputs of Nd:YAG laser operating in 10Hz using boxcar averager, and with taking this averaged output as an input signal, we conducted PID control using optical attenuator which is consisted of half wave plate attached on the stepping motor and polarizer. When PID control was not enabled, the power fluctuation was 4.71% and with PID control, the power fluctuation was 1.86% for 2 hours and 1 hour respectively. As a result, we stabilized the power fluctuation of the pulse laser by 60.5%

  • PDF

PID 제어기법을 이용한 펄스 레이저 출력 안정화에 관한 연구 (Pulse Laser Power Stabilization Using PID Control Method)

  • 류훈철;곽승우;강동원;김경식;한재원
    • 한국레이저가공학회:학술대회논문집
    • /
    • 한국레이저가공학회 2006년도 춘계학술발표대회 논문집
    • /
    • pp.89-96
    • /
    • 2006
  • In this study, PID control method was applied to decrease the power fluctuation of the pulse laser which is one of the major processing variables in laser machining process. To stabilize the power fluctuation of the pulse laser, we averaged 10 pulse outputs of Nd:YAG laser operating in 10Hz using boxcar averager, and with taking this averaged output as an input signal, we conducted PID control using optical attenuator which is consisted of half wave plate attached on the stepping motor and polarizer. When PID control was not enabled, the power fluctuation was 4.71% and with PID control, the power fluctuation was 1.86% for 2 hours and 1 hour respectively. As a result, we stabilized the power fluctuation of the pulse laser by 60.5%

  • PDF

펄스파워 시스템용 고전압 펄스변압기의 EMTP 시뮬레이션 (A EMTP Simulation of High-Voltage Pulse Transformer for Pulsed Power System)

  • 김민수;이형구;주홍진;고광철;강형부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1984-1986
    • /
    • 2000
  • In pulsed-power techniques. Marx generator is generally used for the high-power device. but this generator has insulation and spatial problems. So we will suggest a pulse transformer that has a small size to generate the high voltage pulse instead of Marx generator. In this paper, Pulse duration is 4 [${\mu}s$] and the ratio of input and output voltage is 40[kV]/200[kV](step-up ratio=5). The output voltage and the process of pulse compression for pulse circuit are simulated by EMTP (Electro-Magnetic Transient Program). The secondary voltage of pulse transformer is about 200[kV] and pulse width is 4[t/s]. When the secondary winding of the pulse transformer is saturated. the pulse width is 1.25[${\mu}s$]. We selected dummy load 50[$\Omega$] for impedance matching. The pulse voltage of dummy load is 100[kV] and pulse width is 500[ns].

  • PDF

Novel Compact Current Type Pulse Power Generator

  • Min, B.D.;Kim, J.H.;Pavlov, E.;Yoo, D.W.;Rim, G.H.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.529-531
    • /
    • 2005
  • This paper proposes a compact pulse generator fur NOx removal application for diesel automotive. The rising time is important factor to increase NOx removal efficiency in pulsed corona discharge method. Manufacturing cost and compactness of the pulse power generator should be satisfied for automotive application. The proposed pulse power uses a low voltage thyristor, a pulse transformer with the function of saturated magnetic switch, and series connected general diodes as opening switch to satisfy that requirements. With 200 resistor load, the experiment results show that the output voltage is 21kV, the rising time is about 21ns, and the pulse width (FWHM) is about 42ns.

  • PDF

Power Tracking Control of Domestic Induction Heating System using Pulse Density Modulation Scheme with the Fuzzy Logic Controller

  • Nagarajan, Booma;Sathi, Rama Reddy;Vishnuram, Pradeep
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권6호
    • /
    • pp.1978-1987
    • /
    • 2014
  • Power requirement to the induction heating system varies during the heating process. A closed loop control is required to have a smooth control over the power. In this work, a constant frequency pulse density modulation based power tracking control scheme for domestic induction heating system is developed using the Fuzzy Logic Controller. In the conventional power modulation schemes, the switching losses increase with the change in the load. The proposed pulse density modulation scheme maintains minimum switching losses for the entire load range. This scheme is implemented for the class-D series resonant inverter system. Fuzzy logic controller based power tracking control scheme is developed for domestic induction heating power supply for various power settings. The open loop and closed loop simulation studies are done using the MATLAB/Simulink simulation tool. The control logic is implemented in hardware using the PIC16F877A microcontroller. Fuzzy controller tracks the set power by changing the pulse density of the gate pulses applied to the inverter. The results obtained are used to know the effectiveness of the fuzzy logic controller to achieve the set power.

고출력 전자기파에 대한 전력망 피해 비용 산출 (Estimation of Damage in Electric Power Networks due to High Power Electromagnetic Pulse)

  • 현세영;두진경;김우주;육종관
    • 한국전자파학회논문지
    • /
    • 제25권7호
    • /
    • pp.757-766
    • /
    • 2014
  • 본 논문은 거시적인 접근방법을 이용하여 고출력 전자기파에 대한 피해 비용을 보다 실제적으로 산출하기 위한 방법을 제시하고, 이에 대한 피해액을 계산하였다. 먼저 취약성 분석을 통하여 사회 기반 시설 중 사회적으로 가장 큰 혼란을 야기할 수 있을 것이라고 판단되는 전력망에 집중하여 연구하였으며, 이에 대해 고출력 전자기파에 의한 피해액 계산식은 GDP에 대한 총 에너지 소비를 고려하여 고출력 전자기파 피해 시 발생할 수 있는 피해 손실을 효과적으로 예측하기 위한 방법을 제시하였다. 피해액은 고출력 전자기파의 공격 형태에 따라 피해 범위를 설정하고 계산하였으며, 이러한 피해액 계산을 통하여 고출력 전자기파에 취약한 시설에 대해서는 피해액 산출 후 방호 비용과 비교하여 시설 방호 대책을 수립할 수 있는 기반을 마련할 수 있을 것이다.

HVDC용 12-펄스 위상제어정류기의 새로운 게이트 펄스 발생 기법 (A New Gate Pulse Generating Method of 12-Pulse Phase Controlled Rectifier for HVDC)

  • 안종보;김국헌;이종무;이기도
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.139-141
    • /
    • 2000
  • High voltage direct current(HVDC) transmission system uses the phase controlled rectifier triggered by means of IPC(individual phase control) or EPC(equidistant pulse control). Most HVDC system has adopted EPC method that can solve the harmonic instability problem of IPC method in weak power system. But EPC has inherent indirect synchronizing problem requiring the closed loop control. This paper presents the new gate pulse generating method for 12-pulse HVDC converter, which combines IPC with EPC. Simulation and test results are presented. The basic concept is that it generates the gating pulse for 12-pulse converter by synthesizing the internal phase reference using the frequency and phase information of a sin91e phase voltage. To ensure the reliability of the external phase input, Potential transformer that detects the phase voltage has redundancy. Using fault detecting algorithm the healthy input is always guaranteed. And the frequency compensation function was reinforced.

  • PDF