• 제목/요약/키워드: Pulse on time

검색결과 1,711건 처리시간 0.034초

음식섭취에 따른 좌우(左右) 촌관척(寸關尺) 6부위 맥압 변화 연구 (The Effect of Food Intakes on Radial Pulse Amplitude)

  • 임윤경;강희정;이병렬;양기영;이현;김경철
    • Korean Journal of Acupuncture
    • /
    • 제28권2호
    • /
    • pp.13-22
    • /
    • 2011
  • Objectives : The purpose of this study is to investigate the effect of food intake on radial pulse amplitude. Methods : Thirty one healthy male subjects participated in this study. Radial pulse was measured using 3 dimensional pulse imaging system (DMP-3000) before, right after, 40 minutes after, 80 minutes after and 120 minutes after food intake. Results : 1. The amplitude of h1 increased significantly right after food intake compared to 'before food intake' at all 6 measuring points. Later on, it decreased back as time passed, however, even 120 minutes later, it was still higher than 'before food intake' 2. Pulse energy, which is calculated from pulse waves acquired with five sensors, increased after food intake as well. Conclusions : Food intake exerts an influence on radial pulse amplitude, resulting in increase of h1 and pulse energy.

다중레이트 필터링 기법을 이용한 맥파전달시간 추정 (Estimation of PTT (Pulse Transit Time) by Multirate Filtering Analysis)

  • 김현태;김정환;김경섭;이재호;이정환
    • 전기학회논문지
    • /
    • 제62권7호
    • /
    • pp.1020-1026
    • /
    • 2013
  • Multirate filtering process on the biological signals like Electrocardiogram (ECG) and Photoplethysmogram (PPG) can be defined as the digital signal processing algorithm in which the sampling rate varies to omit or interpolate the intermediate values between the sampled data. With this aim, we suggest a new multirate filtering algorithm by deleting the extraneous data to eliminate the unwanted degradations such as granular noise due to the usage of high sampling frequency and simultaneously to detect the fiducial features of ECG and PPG with reducing the complexity of resolving fiducial points such as R-peak, Pulse peak and Pulse Transit Time (PTT). After the experimental simulations performed, we can conclude the fact that we can detect the fiducial features of ECG and PPG signal in terms of R-peak, Pulse peak and PTT without the loss of accuracy even if we do not maintain the original sampling frequency.

이터븀 첨가 능동형 Q-스위칭 광섬유 레이저에서 Q-스위치 상승 시간이 출력 펄스에 미치는 영향에 대한 이론적 분석 (Theoretical Analysis of Impact of Q-switch Rise Time on Output Pulse Performance in an Ytterbium-doped Actively Q-switched Fiber Laser)

  • 전진우;이준수;이주한
    • 한국광학회지
    • /
    • 제24권2호
    • /
    • pp.58-63
    • /
    • 2013
  • 본 논문에서는 능동형 Q-스위칭 광섬유 레이저에서 Q-스위치 상승 시간이 출력 펄스에 미치는 영향을 이론적으로 분석하였다. Finite Difference Time Domain (FDTD) 방법을 이용해서 비율 방정식과 전파 방정식에 대한 모델링을 수행하였다. Q-스위칭 광섬유 레이저에서 발생하는 Q-스위칭 펄스의 생성에 있어서 Q-스위치의 상승 시간이 출력 펄스 특성에 미치는 영향을 이론적으로 분석하였다. 또한, Q-스위치의 반복률에 따른 출력 펄스의 에너지 변화와 파형 변화를 확인하였다. Q-스위치 반복률이 높아지고, Q-스위치의 상승 시간이 길어질수록 출력 펄스의 멀티 피크 현상이 줄어들고 안정된 가우시안 형태의 펄스 파형이 발생함을 확인 할 수 있었다.

초고주파 집적회로 설계를 위한 펄스의 시간영역 분산 특성 해석 (Time Domain Analysis of Dispersion Characteristics of Pulse for MMIC Design)

  • 김기래
    • 한국정보통신학회논문지
    • /
    • 제17권8호
    • /
    • pp.1755-1760
    • /
    • 2013
  • 본 논문에서는 마이크로스트립 선로를 따라 펄스가 전송될 때 분산에 의한 펄스의 왜곡특성을 시간영역에서 해석 하였다. 전송선로의 구조, 유전율에 따른 분산특성을 비교 분석하였고, 구형펄스와 가우시안 펄스에 대해 펄스의 폭과 진폭, 그리고 전송속도에 따라 분산특성을 분석하였다. 구형 펄스의 경우 더 높은 고차 고조파 성분을 가지고 있기 때문에 이에 따른 저차 고조파 성분과의 위상 속도 차이가 선로를 따라 진행함에 따라 급격히 나타나서 분산이 심하게 나타났다. 본 연구의 결과는 MIC 또는 MMIC를 설계할 때 펄스전송에서 왜곡을 최소화하기 위해 펄스 폭, 선로의 폭, 기판의 높이 그리고 유전율을 결정하는데 유용하게 사용될 것이다.

Nonequilibrium Heat Transfer Characteristics During Ultrafast Pulse Laser Heating of a Silicon Microstructure

  • Lee Seong Hyuk
    • Journal of Mechanical Science and Technology
    • /
    • 제19권6호
    • /
    • pp.1378-1389
    • /
    • 2005
  • This work provides the fundamental knowledge of energy transport characteristics during very short-pulse laser heating of semiconductors from a microscopic viewpoint. Based on the self-consistent hydrodynamic equations, in-situ interactions between carriers, optical phonons, and acoustic phonons are simulated to figure out energy transport mechanism during ultrafast pulse laser heating of a silicon substrate through the detailed information on the time and spatial evolutions of each temperature for carriers, longitudinal optical (LO) phonons, acoustic phonons. It is found that nonequilibrium between LO phonons and acoustic phonons should be considered for ultrafast pulse laser heating problem, two-peak structures become apparently present for the subpicosecond pulses because of the Auger heating. A substantial increase in carrier temperature is observed for lasers with a few picosecond pulse duration, whereas the temperature rise of acoustic and phonon temperatures is relatively small with decreasing laser pulse widths. A slight lagging behavior is observed due to the differences in relaxation times and heat capacities between two different phonons. Moreover, the laser fluence has a significant effect on the decaying rate of the Auger recombination.

다양한 펄스 반복률에서의 NPN BJT (Bipolar Junction Transistor)의 파괴 특성에 관한 연구 (A Study on Destruction Characteristics of BJT (Bipolar Junction Transistor) at Different Pulse Repetition Rate)

  • 방정주;허창수;이종원
    • 한국전기전자재료학회논문지
    • /
    • 제27권3호
    • /
    • pp.167-171
    • /
    • 2014
  • This paper examines the destruction behavior of NPN BJT (bipolar junction transistor) by repetition pulse. The injected pulse has a rise time of 1 ns and the maximum peak voltage of 2 kV. Pulse was injected into the base of transistor. Transistor was destroyed, current flows even when the base power is turned off. Cause the destruction of the transistor is damaged by heat. Breakdown voltage of the transistor is 975 V at single pulse, and repetition pulse is 525~575 V. Pulse repetition rate increases, the DT (destruction threshold) is reduced. Pulse Repetition rate is high, level of transistor destruction is more serious.

펄스파 자왜 센서를 이용한 고정밀 액위 센서 시스템의 실현에 관한 연구 (Implementation of High Accurate Level Sensor System using Pulse Wave Type Magnetostriction Sensor)

  • 최우진;이준탁
    • 전기학회논문지
    • /
    • 제62권3호
    • /
    • pp.395-400
    • /
    • 2013
  • In this paper, we introduce the implementation of high accurate level sensor system using the pulse wave type magnetostriction sensor. When a current pulse flows along the waveguide, the magnetic field also propagates towards the end of waveguide. When this magnetic field just passes the position of the magnet for level detection, the resultant magnetic field by these two magnetic fields makes a torsional reflected signal. This is used to calculate the time difference between a interrogation pulse wave and this torsional reflected signal. The key elements and characteristics were investigated to implement level sensor system based on this principle. We introduce a method to calculate the speed of ultrasonic reflected signal and how to make a model of sensing coil. In particular, we experiment with the characteristics of the torsional reflected signal according to the changes of the interrogation voltage and displacement. To make high accurate level sensor system, two methods were compared. One is to use the comparator and time counter, the other is STFT(Short Time FFT) which is capable of the time-frequency analysis.

음식섭취에 따른 좌우(左右) 촌관척(寸關尺) 6부위 맥파의 주파수 분석 (A Study on the Effect of Food Intake on Radial Pulse using Fourier Analysis)

  • 임윤경;박광석
    • 대한한의학회지
    • /
    • 제32권4호
    • /
    • pp.139-148
    • /
    • 2011
  • Objective: The purpose of this study was to investigate the effect of food intake on the Fourier components of radial pulse wave. Methods: Thirty-one healthy male subjects participated in this study. Radial pulse was measured using 3 dimensional pulse imaging system (DMP-3000) before, right after, 40 minutes after, 80 minutes after and 120 minutes after food intake. Fourier transform was performed and the frequency and amplitude of Fourier components were analyzed. Results: 1. The frequency and the amplitude of Fourier components of radial pulse wave increased significantly after food intake. 2. The frequency of Fourier components increased right after food intake and then gradually decreased as time passed, however the amplitude of Fourier components increased and maintained certain levels and patterns throughout the experimental period of 120 minutes. 3. The change ratios of the frequency and the amplitude of Fourier components after food intake varied with the pulse measuring locations. Conclusions: Food intake exerts an influence on radial pulse wave, resulting in increase of frequency and amplitude of Fourier components. The change ratios of the frequency and the amplitude of Fourier components after food intake varied with the pulse measuring locations.

AC-PDP에서의 주파수 및 duty비의 영향에 따른 전기광학적 특성 (Influence of frequency and duty ratio on electro-optical characteristics in AC-PDP)

  • 김태영;조태승;안정철;최명철;정진만;임재용;정용환;김성수;정민우;최성혁;김순배;고재준;조광섭;최은하
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 춘계학술대회 논문집 디스플레이 광소자 분야
    • /
    • pp.139-142
    • /
    • 2000
  • Influence of frequency and duty ratio on electro-optical characteristics are experimentally investigated in surface AC plasma display panels(AC-PDPs) by using the VDS(Versitile Driving Simulator)., in which electrode gap and width are 100 ${\mu}m$ and 260 ${\mu}m$, respectively. The filling gas is Ne-Xe gas mixture, and total pressure 400 Torr. It is found that the response time gets to be fast from 450 ns to 150 ns as pulse-off time of the sustain pulse decreases from 2 ${\mu}s$ to 0.2 ${\mu}s$. Also it is found that the IR(Infra Red) intensity and the luminous decreases as pulse-off time of the sustain pulse increases from 0.2 ${\mu}s$ to 2 ${\mu}s$.

  • PDF

바이스태틱 레이더의 시스템 불안정 요소들에 대한 분석 (Analysis of System Instability Factors in a Bistatic Radar)

  • 양진모;이민준;윤재룡;김환우
    • 한국군사과학기술학회지
    • /
    • 제14권1호
    • /
    • pp.114-122
    • /
    • 2011
  • In this paper, we have identified the system instability factors in a bistatic radar system using pulse chasing and considered their effects on the bistatic receiver's MTI(Moving Target Indication) improvement performance. The pulse chasing is a method to efficiently scan a restricted search area within the limited transmitter power and time in a bistatic radar and to track a series of transmitted pulses using the receiver beam which has ideally matched to the pulse propagation rate. In this paper, we have discussed the interrelationship between the pulse chasing and time and frequency/phase synchronization and described the effects of the identified system instability factors on two kinds of MTI filter configuration, single delay-line and double delay-line, in the bistatic radar. And also, we have confirmed that the overall system improvement is restricted by a lower improvement factor among identified them, and discussed the allowable tolerance of the time and frequency/phase synchronization in the bistatic system.