• Title/Summary/Keyword: Pulse injection

Search Result 245, Processing Time 0.029 seconds

Partial Discharge Characteristics at a Internal Void Using a Pulse Superimposing Technique (펄스 중첩법을 이용한 내부 보이드에서의 부분방전 특성.)

  • Kang, Ji-Hoon;Shin, Doo-Sung;HwangBo, Seung;Han, Min-Koo
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1624-1626
    • /
    • 1997
  • In this paper, a new PD measurement technique of pulse superposition method was proposed in order to investigate both PD mechanism and phase related PD patterns. From the experimental results, we could find that the polarity and the phase angle of the superposed pulse take great effects on PD characteristics and these method make it possible to get the physical information which statistical approach can not give. We could conclude that the changes of PD characteristics in the void surrounded by polymers may be attributed to the injection of charge carriers thereby formation of space charge in the surface and/or the bulk of the polymer.

  • PDF

Effect of Reinforcements on Dynamic Elastic Modulus of Polyethylene Matrix Composite Materials (폴리에틸렌기지 복합재료의 동적탄성계수에 대한 강화재의 효과)

  • 김경섭;정현규;홍순형
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 1999.11a
    • /
    • pp.1-4
    • /
    • 1999
  • The attenuation coefficients of SiC particle reinforced low-density polyethylene (LDPE) matrix composites were measured by pulse echo method and dynamic elastic measure method with varying the volume fraction of SiC particle ranged from 0% to 40% and the size of SiC particles ranged from 0.8$\mu$m to 48$\mu$m. The SiCp/LDPE composites were fabricated with the melt injection process and the fabricated composites showed almost full density above 99% up to 40vo1% SiCp reinforcements. The attenuation constant of LDPE measured by dynamic elastic constant had same result with that measured by pulse echo method, but the attenuation constant of SiCp/LDPE measured by dynamic elastic constant did not have same result with that measured by pulse echo method.

  • PDF

A Study on the Removal of SOx/NOx by a Pulsed Corona Discharge in the Wire-Plate Reactor (Wire-Plate 반응기에서 펄스 코로나 방전을 이용한 탈황 탈질에 관한 연구)

  • Shin, Wan-Ho;Song, Yong-Hoon;Kim, Han-Seok;Choi, Yeon-Seok;Kim, Seok-Joon
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1910-1912
    • /
    • 1996
  • This paper presents the results of laboratory experimentals to remove $SO_2$ and $NO_x$ by a pulsed corona discharge in the wire-plate reactor. A rotating spark gap switch was used to generate the pulse by chewing the dc high voltage. Repetition frequency of the pulse was 60Hz and rising time of 50ns. The photo pictures of positive streamer corona taken by ICCD camera, pulse voltage and current were measured using a digital oscilloscope. Simultaneous effects of $C_{2}H_{4}$ injection and heterogeneous chemical reactions on nonthermal plasma process to remove $SO_2$ and $NO_x$ from flue gas were investigated in the present study

  • PDF

PROSPECTIVE CLINICAL STUDY OF MIDAZOLAM SEDATION IN PATIENTS UNDERGOING DENTAL PRACTICE (Midazolam과 국소 마취제를 이용한 정맥 내 진정법 시 치과 환자에서 관찰되는 변화에 대한 연구)

  • Kim, Seong-Gon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.34 no.2
    • /
    • pp.131-134
    • /
    • 2008
  • Purpose: The objective of this study was to evaluate the clinical parameters in terms of the midazolam sedation in patients undergoing dental practice. Patients and Methods: Total 28 patients were included in this study. They received the dental practice in the daycare center and sedation was done with midazolam. The recorded variables were blood pressure, pulse rate, $SpO_2$, and patient's response. The differences between observations were analyzed with paired samples t-test. Results: The blood pressure was significantly decreased after the administration of midazolam and the systolic pressure was significantly increased at the start of operation (P<0.05). The pulse rate was significantly increased after lidocaine injection (P<0.001). The amnesic effect was shown 21 cases out of 28 cases (75%). Conclusions: The effect of midazolam on pulse rate was not significant. However, midazolam could decrease the blood pressure significantly. Therefore, the sedation with midazolam could be successfully used in the dental practice, particularly for the patients having the hypertension.

Implementation of High Reliable Fault-Tolerant Digital Filter Using Self-Checking Pulse-Train Residue Arithmetic Circuits (자기검사 Pulse별 잉여수연산회로를 이용한 고신뢰화 Fault Tolerant 디지털필터의 구성에 관한 연구)

  • 김문수;손동인;전구제
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.25 no.2
    • /
    • pp.204-210
    • /
    • 1988
  • The residue number system offers the possibility of high-speed operation and error detection/correction because of the separability of arithmetic operations on each digit. A compact residue arithmetic module named the self-checking pulse-train residue arithmetic circuit is effectively employed as the basic module, and an efficient error detection/correction algorithm in which error detection is performed in each basic module and error correction is performed based on the parallelism of residue arithmetic is also employed. In this case, the error correcting circuit is imposed in series to non-redundant system. This design method has an advantage of compact hardware. Following the proposed method, a 2nd-order recursive fault-tolerant digital filter is practically implemented, and its fault-tolerant ability is proved by noise injection testing.

  • PDF

Study on the Spray Characteristics in TBI Injector with Low Pressure (저압 TBI용 분사밸브의 분무특성에 관한 연구 (I))

  • 전흥신;임종한;이택희
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.12
    • /
    • pp.3179-3186
    • /
    • 1993
  • The study on the spray characteristics of TBI(Throttle Body Injection) injector has been carried out in this paper. The objective of this study is to improve the performance of TBI injector. The increase in the injection pressure and the utilization of assisted air are considered. The spray patten of TBI injector take the hollow-cone shape with $60^{\circ}~70^{\circ}$ spray angle regardless of injection pressure and injection pulse width. SAMD(Sauter Mean Diameter) of water in TBI injector are 510-$550{\mu}m$ and 310-$370{\mu}m$ respectively when injection pressures are $0.75 kgf/cm^{2}$ and $2.8 kgf/cm^{2}$. Then SMD of gasoline is estimated 380~$410{\mu}m$ and 230~$280{\mu}m$ respectively. The improvement of spray characteristics in TBI injector can be obtained with assisted air. If $W_{A}/W_{L}$ was over 0.2, SMD of water can be made under $50{\mu}m$.

The Effects of Character Distraction on Intravenous Injection Pain of Hospitalized Preschooler (캐릭터를 이용한 관심전환중재가 학령전기 아동의 정맥주사 시 통증과 주사공포에 미치는 효과)

  • Lim, Ok-Woo;Cho, Kyoul-Ja
    • Child Health Nursing Research
    • /
    • v.12 no.2
    • /
    • pp.215-222
    • /
    • 2006
  • Purpose: This study was done to identify the effects of the distraction generated by character stamp and stickers on reduction of intravenous injection pain. Method: This study was conducted using a quasi experimental non-equivalent control group non-synchronized design. 60 preschool children who admitted to a Pediatric Department in a C University Hospital were selected as subjects. Convenience assignment was used. The two groups were homogeneous on characteristics. Results: In the experimental group, objective pain(t=3.666, p=.001), subjective pain (t=3.415, p=.001) and perceived pain by the mother(t=2.528, p=0.014) decreased after intravenous injections than the control group. There were no statistical significant differences in pulse rate or fear between the experimental and the control group. Conclusion: These findings indicate that using character stamp and stickers could be considered as an independent nursing intervention for intravenous injection pain reduction in preschooler.

  • PDF

Experimental Study of the Effects of Nozzle Hole Geometry for di Diesel Engine (디젤엔진에서 노즐 홀 형상효과의 실험적 연구)

  • Ku, Kun-Woo;Lee, Young-Jin;Kim, In-Su;Lee, Choong-Won
    • Journal of ILASS-Korea
    • /
    • v.12 no.3
    • /
    • pp.154-159
    • /
    • 2007
  • Spray tip penetration and spray angle for one main injection were measured at the atmospheric condition with the fuel injection pressure of 270 bar and 540 bar. It investigates an effect of different nozzle hole geometry of conventional cylindrical one and those of elliptical ones. Injection period represented by injector pulse drive was fixed at 1ms. From the result of this study, it is shown that spray tip penetration becomes shorter and spray angle becomes wider with the elliptical nozzle hole geometry due to fast break-up of a fuel liquid column.

  • PDF