• Title/Summary/Keyword: Pulse Point

Search Result 511, Processing Time 0.026 seconds

Study on intense pulse lighting with high efficiency (고효율의 Intese Pulse Light에 특성연구)

  • Kim, Whi Young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.333-336
    • /
    • 2009
  • the equipment increase switching frequency in order to achieve small size, a low noise, and light weight. however, the power switches have high power losses and switching stresses as the switching frequency is increased. In order to solve like this problem point from the present paper it proposed Intese Pulse Light of the half bridge methods which apply the start current circuit which applies the auxiliary equipment. Simulation and experimental result it leads and it brings is more qualitative there is 20% improvement and it confirmed that a possibility of measuring to the patient.

  • PDF

The Literature Study on Jung point venesection therapy (정혈(井穴) 자락요법(刺絡療法)에 관(關)한 문헌고찰(文獻考察))

  • Kim, Yoon-hee;Lee, Hyun;Lee, Byung-ryul
    • Journal of Haehwa Medicine
    • /
    • v.10 no.1
    • /
    • pp.237-245
    • /
    • 2001
  • I have come to next conclusions in consequnce of documentary study about medical books of many generations regarding Jung point venesection therapy. 1. Jung point is significant as the beginning of pulse energy flow on meridian, the origin of all meridional pulse energy being located at extrimity terminal, confluence of three yin and three yang, and emergent treatment point. 2. Jung point venesection therapy was much used for the first-aid treatment for acute and thermic disease, and that is the combination of the meaning as of restoration from death and emergent treatment of Jung point and function of openning of orifice, leakage of fever, circulation of blood, remove of edema of venesection therapy. 3. It is very much used for emergency case, five sensory organ disease and CVA, heating shock and so on. Besides that digestive disease, cough, fever with cold, childhood disease, cardiac ache, thoracic disease, numbness of digitus terminal, mental disorder follow that in order. 4. Sosang, Jung point of Arm Greater Yin Lung meridian, is very much used for five sensory organ disease. Sosang is for orbital disease, sangyang for auditory disease, sosang for nasal disease, and sosnag for introitus-throat disease. 5. Ten Jung point is most used for first-aid diseases of CVA, heating shock. 6. Ten Jung point is most used for digestive disease of stomach ache, vomiting, diarrhea, intestinal convulsion. 7. Ten Jung point is most used for cold disease of cough, fever, malaria. 8. Ten Jung point, sosang, kwanchung are much used for childhood disease of acute convulsion and fever. 9. Among Jung point, sosang is most used, 34 times. Next there are Ten Jung point, kwanchung, sangyang, sotaek, jungchung, unbaek, taedon in order. In the order of frequency in use, arm channel is more used than leg channel.

  • PDF

The Effects of Sa-Am Spleen-tonifying Acupuncture on Radial Pulse in Healthy Human Subjects (비정격(脾正格) 자침이 정상 성인 맥파(脈波) 변화에 미치는 영향)

  • Yoon, Kwang Sik;Lee, Hyun
    • Journal of Acupuncture Research
    • /
    • v.30 no.4
    • /
    • pp.1-14
    • /
    • 2013
  • Objectives : The purpose of this study is to investigate the effects of Sa-Am spleen-tonifying acupuncture on radial pulse in healthy human subjects. Methods : Forty healthy human subjects participated in this study, divided into acupuncture group and control group. Radial pulse was measured by 3 dimensional pulse imaging system(DMP-3000) before, right after, 30 minutes after and 60 minutes after acupuncture in the acupuncture group. The subjects in the control group didn't received acupuncture but took a rest and then the radial pulse was measured at the same time points as the acupuncture group. The parameters were analyzed by gender, measuring location, and measuring time point. However the time related parameters exceptionally were analyzed without distinction of measuring location. Results : 1. T, variance of period, T2/T, T4/T, (T-T4)/T, T4/(T-T4), and W significantly changed after acupuncture. 2. Pressure, amplitude of H1, amplitude of H2, Amplitude of H4 and pulse energy significantly changed after acupuncture. 3. Pulse area, systolic pulse area and diastolic pulse area significantly changed after acupuncture. 4. Elasticity, AIx and AIx/HR significantly changed after acupuncture. Conclusions : The effect of Sa-Am spleen-tonifying acupuncture in healthy human may be observed on time, amplitude, pulse area and augmentation index. Further studies on the effects of Sa-Am acupuncture using radial pulse are needed.

A Study on Malfunction Mode and Failure Rate Properties of Semiconductor by Impact of Pulse Repetition Rate (펄스 반복률에 의한 반도체 소자의 오동작 모드와 고장률에 관한 연구)

  • Park, Ki-Hoon;Bang, Jeong-Ju;Kim, Ruck-Woan;Huh, Chang-Su
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.6
    • /
    • pp.360-364
    • /
    • 2015
  • Electronic systems based on solid state devices have changed to be more complicated and miniaturized as the electronic systems developed. If the electronic systems are exposed to HPEM (high power electromagnetics), the systems will be destroyed by the coupling effects of electromagnetic waves. Because the HPEM has fast rise time and high voltage of the pulse, the semiconductors are vulnerable to external stress factor such as the coupled electromagnetic pulse. Therefore, we will discuss about malfunction behavior and DFR (destruction failure rate) of the semiconductor caused by amplitude and repetition rate of the pulse. For this experiment, the pulses were injected into the pins of general purpose IC due to the fact that pulse injection test enables the phenomenon after the HPEM is coupled to power cables. These pulses were produced by pulse generator and their characteristics are 2.1 [ns] of pulse width, 1.1 [ns] of pulse rise time and 30, 60, 120 [Hz] of pulse repetition rate. The injected pulses have changed frequency, period and duty ratio of output generated by Timer IC. Also, as the pulse repetition rate increases the breakdown threshold point of the timer IC was reduced.

Implementation of Intelligence Pulse Wave Detection System (지능형 맥진기 구현)

  • Hong, Y.S.;Yu, J.S.;Chang, S.J.;Sun, S.H.;Lee, W.B.;Nam, D.H.;Yu, M.S.;Choi, M.B.;Lee, S.S.
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.2
    • /
    • pp.245-254
    • /
    • 2013
  • In oriental medicine, it is possible to classify and treat many diseases using the pulse wave detection system. Other problems may arise. As it is a very subjective way to analyze the pulse wave. One problem of the conventional pulse wave detection system is that the arterial pulse sensor is not located correctly at the radial artery. Threrefore measurement results can differ depending on the measurement position and the measurement procedure. This is mostly due to it's sensitivity to high reproducibility. In order to solve this problem this paper proposes an algorithm to analyze the weak pulse wave symptom and strong pulse wave symptom. It uses the portable pulse wave detection system which includes a Hall Sensor. As a final result, it analyzed the weak pulse wave symptom and strong pulse wave symptom by the SPSS statistics technique. It proves that N time (notch point time) and S Amp (rise waveform size) mean values are significantly different in 95% confidence interval.

Prospects about Nuclear Electro Magnetic Pulse developed by North Korea (북한의 핵전자기파(NEMP)탄 개발에 대한 전망)

  • Lee, Dae Sung
    • Convergence Security Journal
    • /
    • v.17 no.2
    • /
    • pp.159-164
    • /
    • 2017
  • The international community recognizes North Korea's nuclear and missile provocation as a real threat. This is due to the analysis and evaluation that has developed nuclear electro magnetic pulse of domestic and overseas North Korea experts, intelligence agencies related to electro magnetic pulse. Electro magnetic pulse experts are concerned about North Korea's nuclear electro magnetic pulse in the following aspects. First, industrial, military, medical, and living facilities in modern society are constructed with electrical and electronic systems. So, All electrical and electronic appliances will become neutralization if North Korea's nuclear electro magnetic pulse was set off over the world(i.e. Korean Peninsula, United States etc). Second, North Korea will judge that possibility of criticism by the international community is low from the point of view of an attacker. Because nuclear electro magnetic pulse aim to destroy only the electronic equipment of the opposite nation and cause damage rather than taking life. Finally, nuclear electro magnetic pulse is more threatening than weapons like mass destruction because it does not need to hit targets accurately and can strike a wide area with nuclear weapon of the low technology levels. In this respect, we will analyze and evaluate nuclear and missile development and make a prospects about nuclear electro magnetic pulse developed by North Korea.

The measurement of the half period modulated pulse on earth for detection of a underground electric leakage point (지중선로 누전점 탐지를 위한 반주기 변조된 대지 펄스 측정)

  • Kim, Jae-Hyun;Jeon, Jeong-Chay;Yoo, Jae-Geun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.11
    • /
    • pp.5123-5127
    • /
    • 2011
  • Research and development for the technology, that is about maintenance and accidents prevention of underground power distribution line, are demanding. The precise detection of leakage point of underground power line is very important, because it is difficult to detect the exact location of a fault in underground power line and to repair faults. When earth electric potential is measured to detect underground electric leakage point after transmitting AC electric pulse wave to underground power line, it must be measured in a specific half period of AC pulse wave because the distribution of the electric earth potential varies with the polarity of the transmitted wave. In this paper we proposed the measurement of half period modulated earth potential as a method to detect a underground leakage point. And We compared the proposed method with other methods. Through experiments we verified that the proposed method can be implemented and operated properly.

Development of Feature Points Detection Algorithm for Measuring of Pulse Wave Velocity (맥파 전달 속도(PWV) 측정을 위한 특징점 검출 알고리즘 개발)

  • Choi, Jung-Hyeon;Cho, Wook-Hyun;Park, Jun-Ho;Kim, Nam-Hoon;Seong, Hyang-Sook;Cho, Jong-Man
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.343-350
    • /
    • 2011
  • The compliance and stiffness of artery are closely related with disease of arteries. Pulse wave velocity(PWV) in the blood vessel is a basic and common parameter in the hemodynamics of blood pressure and blood flow wave traveling in arteries because the PWV is affected directly by the conditions of blood vessels. However, there is no standardized method to measure the PWV and it is difficult to measure. The conventional PWV measurement has being done by manual calculation of the pulse wave transmission time between coronary arterial proximal and distal points on a strip chart on which the pulse wave and ECG signal are recorded. In this study, a pressure sensor consisting of strain gauges is used to measure the blood pressure of arteries in invasive method and regular ECG electrodes are used to record the ECG signal. The R-peak point of ECG is extracted by using a reference level and time windowing technique and the ascending starting point of blood pressure is determined by using differentiation of the blood pressure signal and time windowing technique. The algorithm proposed in this study, which can measure PWV automatically, shows robust and good results in the extraction of feature points and calculation of PWV.

Long Distance and High Resolution Three-Dimensional Scanning LIDAR with Coded Laser Pulse Waves (레이저 펄스 부호화를 이용한 원거리 고해상도 3D 스캐닝 라이다)

  • Kim, Gunzung;Park, Yongwan
    • Korean Journal of Optics and Photonics
    • /
    • v.27 no.4
    • /
    • pp.133-142
    • /
    • 2016
  • This paper presents the design and simulation of a three-dimensional pixel-by-pixel scanning light detection and ranging (LIDAR) system with a microelectromechanical system (MEMS) scanning mirror and direct sequence optical code division multiple access (DS-OCDMA) techniques. It measures a frame with $848{\times}480$ pixels at a refresh rate of 60 fps. The emitted laser pulse waves of each pixel are coded with DS-OCDMA techniques. The coded laser pulse waves include the pixel's position in the frame, and a checksum. The LIDAR emits the coded laser pulse waves periodically, without idle listening time to receive returning light at the receiver. The MEMS scanning mirror is used to deflect and steer the coded laser pulse waves to a specific target point. When all the pixels in a frame have been processed, the travel time is used by the pixel-by-pixel scanning LIDAR to generate point cloud data as the measured result.

Condition Monitoring Technique for Heating Cables by Detecting Discharge Signal (방전신호 검출에 의한 히팅 케이블의 상태감시기술)

  • Kim, Dong-Eon;Kim, Nam-Hoon;Lim, Seung-Hyun;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.34 no.2
    • /
    • pp.136-141
    • /
    • 2021
  • Heating cables, widely used in office buildings, factories, streets and railways, deteriorate in electrical insulation during operation. The insulation deterioration of heating cables leads to electric discharges that can cause electrical fires. With this background, this paper dealt with a condition monitoring technique for heating cables by the analysis of discharge signals to prevent electrical fires. Insulation deterioration was simulated using an arc generator specified in UL1699 under AC operation, and the characteristic and propagation of discharge signals were analyzed on a 100 meter-long heating cable. Discharge signals produced by insulation deterioration were detected as a voltage pulse because they are as small as a few mV and they are attenuated through propagation path. The frequency spectrum of discharge signals mainly existed in the range from 70 kHz to 110 kHz, and the maximum attenuation of the signal was 84.8% at 100 meters away from the discharge point. Based on the experimental results, a monitoring device, which is composed of a high pass filter with the cut-off frequency of 70 kHz, a comparator, a wave shaper and a microprocessor, was designed and fabricated. Also, an algorithm was designed to discriminate the discharge signal in the presence of noise, compared with the pulse repetition period and the number of pulse counts per 100ms. In the experiment, the result showed that the prototype monitoring device could detect and discriminate the discharge signals produced at every discharge point on a heating cable.