• 제목/요약/키워드: Pulse Method

검색결과 3,147건 처리시간 0.03초

An Efficient Pulse Width Measurement Method using Multiphase Clock Signals for Capacitive Touch Switches

  • Seong, Kwang-Su
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권4호
    • /
    • pp.773-779
    • /
    • 2013
  • We propose an efficient method to measure a pulse width using multiphase clock signals generated from a ring oscillator. These clocks, which have the same frequency and are evenly spaced, give multiple rising edges within a clock cycle. Thus, it is possible to measure a pulse width more accurately than with existing single clock-based methods. The proposed method is applied to a capacitive touch switch. Experimental results show that the capacitive touch switch with the proposed method gives a 118 fF resolution, which is 6.4 times higher than that of the touch switch with a single clock-based pulse width measurement method.

새로운 맥상 파라메터를 이용한 허실맥 판단 방법 (Method for Determining the Deficient and Solid Pulse with a New Pulse Wave Parameter)

  • 김성훈;김재욱;전영주;김근호;김종열
    • 동의생리병리학회지
    • /
    • 제24권1호
    • /
    • pp.42-47
    • /
    • 2010
  • The pulse diagnosis is an important method in Oriental Medicine. Recently, there have been continuous attempts to replace the finger palpation by Oriental medical doctors (OMDs) by more objective tools based on machines, e.g., pulse analyzers. To improve the performance of the pulse analyzers, both the machine-appropriate interpretations for the pulse images appeared in the literature and the improvement in the repeatability and reproducibility of the measurement sensors are to be developed. As an attempt towards the transformation of the pulse images in terms of machine-appropriate language, in this work, we suggest an upgraded algorithm for the solid/deficient pulses, which are the two representative pulse images informing us how strong the pulse pressure is. It has been argued that one could determine the solid/deficient pulses by the maximum pulse pressure from pulse analyzers. However, by a clinical test, we found that the maximum pulse pressure alone is not sufficient to determine the solid/deficient pulses. In addition to the maximum pulse pressure, the mean pulse pressure averaged over for five different hold-down pressures(3-D MAC) is needed to improve the agreement with the OMD's decision for the solid/deficient pulse. We found that, among the data diagnosed with having either the solid pulse or deficient pulse by OMDs, the novel algorithm showed 86.0% diagnosis rate and 81.6% concordance rate.

5단계 가압에 대한 맥파 변화 분석에 의한 맥 패턴 분류와 부침맥(浮沈脈) 연구 (A study on floating and sinking pulse by classification of pulse pattern through analysis of P-H volume-curve at 5 applied pressure levels)

  • 권선민;강희정;임윤경;이용흠
    • Korean Journal of Acupuncture
    • /
    • 제27권1호
    • /
    • pp.13-22
    • /
    • 2010
  • Objectives: The information on the depth where pulse wave appears is as important as pulse waveform. The aim of this study was to classify pulse pattern using pressure-height(P-H) volume-curve by 5 applied pressure levels to find out the information on the depth of pulse and interpret the floating & sinking pulse in oriental medical pulse diagnosis. Methods: We used 3 dimensional pulse imaging analyser (DMP-3000, DAEYOMEDI Co., Korea), which measures radial pulse waveforms noninvasively by way of tonometric method at 5 applied pressure levels, and shows P-H volume-curves by applied pressure. 448 subjects were enrolled, pulse waveforms were measured and the P-H volume-curves were gained on the three locations of Chon, Kwan, and Cheok. Results: Gained P-H volume curves were classified into 3 types ; increase type, decrease type, and increase-decrease type. Increase-decrease type appeared more often on Chon and Kwan, while increase type appeared more often on Cheok. In a few cases, decrease-type appeared on Chon and Kawn, however it never appeared on Cheok. Conclusions: Through the classification of pulse by P-H volume-curve, we gained the information on the depth of pulse. We speculate the decrease type as floating pulse, the increase-decrease type as middle pulse, and the increase type as sinking pulse in oriental medical pulse diagnosis. After more researches on P-H volume-curve by applied pressure, the P-H volume-curve may be used as an important factor for pulse diagnosis.

맥진(脈診)에 관한 도상(圖像)연구 (A Study on Images of the Pulse Diagnosis)

  • 한봉재
    • 한국한의학연구원논문집
    • /
    • 제15권2호
    • /
    • pp.101-109
    • /
    • 2009
  • The Pulse diagnosis is in the boundary of the Four Examinations, and it is called 切診, or palpation. It has a great impact on people in reminding of the Traditional Medicine that it is probably the first thing that people think of when they hear about Traditional Medicine. Hu-Jun quoted in the Treasured Mirror of Eastern Medicine "東醫寶鑑" that the doctor finds out the deficiency and the excess of the meridian of the patiant through the pulse, and that it is of the utmost necessity to know the "deficiency and the excess" of the meridian to decide the formula (君臣佐使) of the herbal medicine and the acupuncture/moxibustion treatment. The research on the studies of pulse diagnosis have been concentrated on the origin, history, and the theory of the pulse diagnosis throughout the years; however, the number of research on the image from the classics on pulse diagnosis have been less. With this in mind, this paper was written to study more on the origin and the history of the pulse diagnosis as well as to study on the image of pulse diagnosis shown on the classics on Traditional Medicine in China and Korea. The history of the pulse diagnosis has its root on the attempt to find out what is happening inside the body through the indication of the small changes of the pulse that is shown on the outer boundaries of the body. There were various kinds of pulse diagnosis including "Three positions and nine indicators method" and "Carotid pulsation and wrist pulse method" in the ancient period, and wrist pulse-taking method became the most popular since the completion of studying on palpation by 初보. The image of the palpation helps the rudimentary practitioners of Traditional Medicine. They are divided into two large categories, which are the area of diagnosis and the shape of the pulse itself. The historical classics including the image of the pulse diagnosis can be found since the Song Dynasty of China. There are various kinds of image of pulse diagnosis in the classic such as "The picture of the hand meridian" from "脈訣指掌病式圖說", "The picture of the image of meridian" from "察病指南", "The picture of the Seven exterior and Eight interior" from "校正圖注脈訣", and "The picture of the six parts of meridian" from Treasured Mirror of Eastern Medicine "東醫寶鑑". The Treasured Mirror of Eastern Medicine "東醫寶鑑" have analyzed the basic theories and made up the standards of pulse diagnosis by establishing "The picture of the six parts of meridian" based on "The method of placing the viscera and bowels corresponding to cun-guan-qi, or the meridian".

  • PDF

새로운 일반형 블럭 펄스 적분 연산 행렬을 이용한 선형 시불변 시스템 해석 (Analysis of Linear Time-invariant System by Using a New Block Pulse Operational Matrices)

  • 이해기;김태훈
    • 전기학회논문지P
    • /
    • 제53권4호
    • /
    • pp.175-182
    • /
    • 2004
  • This paper presents a new method for finding the Block Pulse series coefficients, deriving the Block Pulse integration operational matrices and generalizing the integration operational matrices which are necessary for the control fields using the Block Pulse functions. In order to apply the Block Pulse function technique to the problems of state estimation or parameter identification more efficiently, it is necessary to find the more exact value of the Block Pulse series coefficients and integral operational matrices. This paper presents the method for improving the accuracy of the Block Pulse series coefficients and derives generalized integration operational matrix and applied the matrix to the analysis of linear time-invariant system.

글라스 레이저 발진기의 출력펄스특성의 개선에 관한 연구 (Improvement of pulse characteristics of glass laser oscillator)

  • 강형부
    • 전기의세계
    • /
    • 제29권5호
    • /
    • pp.321-328
    • /
    • 1980
  • The Q-switching oscillator of TE $M_{00}$ mode was constructed in order to improve the properties of energy focusing and amplification, and prevent laser materials from breakdown. The Q-switching was done by means of electro-optical effect using Glan prism and KDP Pockels cell. Sharp laser pulse of risetime-1 ns and variable pulse width 2-10 ns was obtained from Q-switching laser pulse by PTM method using a laser triggered spark gap (LTSG), Glan prism and Pockels cell. A single ultra-short pulse (picosec order in pulse width) was obtained from mode-locked pulse train in combination of a mode-locked oscillator using saturable dye cell with pulse shaping system using PTM method.d.

  • PDF

Lagrange 이차 보간 다항식을 이용한 새로운 일반형 블럭 펄스 적분 연산 행렬 (A New Block Pulse Operational Matrices Improved by The Second Order Lagrange Interpolation Polynomial)

  • 심재선;김태훈
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제52권6호
    • /
    • pp.351-358
    • /
    • 2003
  • This paper presents a new method for finding the Block Pulse series coefficients, deriving the Block Pulse integration operational matrices and generalizing the integration operational matrices which are necessary for the control fields using the Block Pulse functions. In order to apply the Block Pulse function technique to the problems of state estimation or parameter identification more efficiently, it is necessary to find the more exact value of the Block Pulse series coefficients and integral operational matrices. This paper presents the method for improving the accuracy of the Block Pulse series coefficients and derives the related integration operational matrices and generalized integration operational matrix by using the Lagrange second order interpolation polynomial.

소형트랜스의 Cascading 방식을 적용한 임펄스 출력특성 (The Impulse Output Characteristics using Cascading Method of Compact Transformer)

  • 정종한;김휘영;홍정환;박구렬;김희제;조정수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1865-1867
    • /
    • 2000
  • The pulse power system has been widely used to many applications. such as E/P(Electrostatic Precipitator), DeNOx/DeSOx power system, ozon generator. etc. A pulse energy efficiency for load depend on the rising time, peak value, pulse duration, impedance matching. etc. The pulse generator generally required for short pulse duration, high peak value was forced to consider its size and economy. In this study, developing a compact pulse generator that applied for Cascading method to be made of two pulse transformer, we compared cascading voltage with no cascading one by applying the pulse energy to load.

  • PDF

심혈관계 시뮬레이터를 이용한 맥파 반사지점 추정방법들의 비교 (Evaluation of methods for estimating the pulse reflection site with cardiovascular simulator)

  • 이주연;신상훈
    • 대한한의진단학회지
    • /
    • 제19권1호
    • /
    • pp.47-54
    • /
    • 2015
  • Objective Wave reflection is an important factor that determines the shape of the pulse wave. The purpose of this study is to compare the conventional method used for estimating the reflection site of pulse with a cardiovascular simulator. Methods: In this study, cardiovascular simulator with one elastic tube was used. The pressure and flow was measured simultaneously at three different points. The measured data were used to the conventional methods to estimate the pulse wave reflection site. The results were compared with the known length which were the distances from the measured points to the end of tube. Results & Conclusions: There is a significant error with the time domain method. While, the reflection site with the frequency domain method was similar to the actual reflection site.

HVDC용 12-펄스 위상제어정류기의 새로운 게이트 펄스 발생 기법 (A New Gate Pulse Generating Method of 12-Pulse Phase Controlled Rectifier for HVDC)

  • 안종보;김국헌;이종무;이기도
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.139-141
    • /
    • 2000
  • High voltage direct current(HVDC) transmission system uses the phase controlled rectifier triggered by means of IPC(individual phase control) or EPC(equidistant pulse control). Most HVDC system has adopted EPC method that can solve the harmonic instability problem of IPC method in weak power system. But EPC has inherent indirect synchronizing problem requiring the closed loop control. This paper presents the new gate pulse generating method for 12-pulse HVDC converter, which combines IPC with EPC. Simulation and test results are presented. The basic concept is that it generates the gating pulse for 12-pulse converter by synthesizing the internal phase reference using the frequency and phase information of a sin91e phase voltage. To ensure the reliability of the external phase input, Potential transformer that detects the phase voltage has redundancy. Using fault detecting algorithm the healthy input is always guaranteed. And the frequency compensation function was reinforced.

  • PDF