• Title/Summary/Keyword: Pulse Method

Search Result 3,147, Processing Time 0.03 seconds

High-Dose-Rate Electron-Beam Dosimetry Using an Advanced Markus Chamber with Improved Ion-Recombination Corrections

  • Jeong, Dong Hyeok;Lee, Manwoo;Lim, Heuijin;Kang, Sang Koo;Jang, Kyoung Won
    • Progress in Medical Physics
    • /
    • v.31 no.4
    • /
    • pp.145-152
    • /
    • 2020
  • Purpose: In ionization-chamber dosimetry for high-dose-rate electron beams-above 20 mGy/pulse-the ion-recombination correction methods recommended by the International Atomic Energy Agency (IAEA) and the American Association of Physicists in Medicine (AAPM) are not appropriate, because they overestimate the correction factor. In this study, we suggest a practical ion-recombination correction method, based on Boag's improved model, and apply it to reference dosimetry for electron beams of about 100 mGy/pulse generated from an electron linear accelerator (LINAC). Methods: This study employed a theoretical model of the ion-collection efficiency developed by Boag and physical parameters used by Laitano et al. We recalculated the ion-recombination correction factors using two-voltage analysis and obtained an empirical fitting formula to represent the results. Next, we compared the calculated correction factors with published results for the same calculation conditions. Additionally, we performed dosimetry for electron beams from a 6 MeV electron LINAC using an Advanced Markus® ionization chamber to determine the reference dose in water at the source-to-surface distance (SSD)=100 cm, using the correction factors obtained in this study. Results: The values of the correction factors obtained in this work are in good agreement with the published data. The measured dose-per-pulse for electron beams at the depth of maximum dose for SSD=100 cm was 115 mGy/pulse, with a standard uncertainty of 2.4%. In contrast, the ks values determined using the IAEA and AAPM methods are, respectively, 8.9% and 8.2% higher than our results. Conclusions: The new method based on Boag's improved model provides a practical method of determining the ion-recombination correction factors for high dose-per-pulse radiation beams up to about 120 mGy/pulse. This method can be applied to electron beams with even higher dose-per-pulse, subject to independent verification.

A method for automatically adjusting threshold to improve the intercept pulse detection performance of submarine (잠수함의 방수펄스탐지 성능 향상을 위한 문턱값 자동 조절 방법)

  • Kim, Do-Young;Shin, Kee-Cheol;Eom, Min-Jeong;Kwon, Sung-Chur
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.22 no.4
    • /
    • pp.213-219
    • /
    • 2021
  • The submarine's intercept pulse detection detects pulses radiated from enemy surface ships, submarines, and torpedoes, and performs an important function of providing maneuverability and survivability of submarine. Whether or not the intercept pulse is detected is determined by comparing the size of the received pulse with the threshold value by the operator. In the case of intercept pulses, the intensity of the pulses is frequently reduced under the influence of various environmental factors. In the situation, if detection is performed with a fixed threshold, a non-detection problem occurs and persists until the operator sets a low threshold. In this paper, we proposed method for automatically adjusting threshold to reduce the non-detection problem caused by a fixed threshold. Simulation were preformed on 4 cases with different pulse level fluctuation widths, and it was confirmed that the detection performance was improved by increasing the number of detections when a method for automatically adjusting threshold was applied to all cases. Through the proposed method, it is expected that the intercept pulse detection performance will be improved in the marine environment the large fluctuations in pulse level in the future.

A Study of Judgment for Irregular Pulses Referred in Donguibogam(東醫寶鑑) (부정맥(不整脈)에 대한 동의보감(東醫寶鑑)의 판단기준 연구(硏究))

  • Jo, Mi-Jeong;Jung, Hyun-Jong
    • The Journal of Korean Medical History
    • /
    • v.26 no.2
    • /
    • pp.63-74
    • /
    • 2013
  • Objective : In Donguibogam(東醫寶鑑), like a slow pulse with irregular intervals(結脈), an abrupt pulse(促脈) and a slow and weak pulse with regular intervals(代脈), an uneven pulse is written as a kind of arrhythmia. Such a recognition differs from the present one. In this study, I try to seize the meaning and deliberate whether those expressions are appropriate. Method : 1. Collect and compare the materials of the above four pulses among documentary records of feeling the pulse for diagnosis. 2. Grasp the aspect and trend of changes. 3. Reason whether records in Donguibogam(東醫寶鑑) are proper or not. Result & Conclusions : Donguibogam(東醫寶鑑) written "like a slow pulse with irregular intervals(結脈), an abrupt pulse(促脈) and a slow and weak pulse with regular intervals(代脈), an uneven pulse is written as a kind of arrhythmia". It is not 'an uneven pulse' is written about irregularity of pulse, but 'an uneven pulse' is written about irregularity of the sense able to be felt on the fingertip.

A Study on The U Control of Resonant Inverters (공진형 인버터의 PWM 제어에 관한 연구)

  • 유완식;조규민
    • Proceedings of the IEEK Conference
    • /
    • 2000.06e
    • /
    • pp.17-20
    • /
    • 2000
  • Usually, in many applications, high frequency resonant inverters are used, and the PAM(Pulse Amplitude Modulation), PFM(Pulse Frequency Modulation) or PWM(Pulse Width Modulation) techniques are used to control the output power of resonant inverters. In this paper, a new switching scheme is proposed as a PWM control method. With the proposed method, it can be obtained that unity output displacement factor under the variable resonant frequency. The detail algorithm of the proposed PWM switching scheme and its charicteristics are discussed. And the validity of the proposed method is confirmed with the experimental results.

  • PDF

Design of the gate drive circuit for floating MOSFET using the pulse transformer (펄스 변압기를 이용한 비접지 MOSFET의 게이트 구동 회로 설계)

  • Park, Chong-Yeun;Lee, Bong-Jin
    • Journal of Industrial Technology
    • /
    • v.27 no.B
    • /
    • pp.15-20
    • /
    • 2007
  • This paper presents the new design method for the gate driver circuit of the floating MOSFET by using the pulse transformer. Each parameters of the proposed circuit are delivered by the numerical calculation method. By considering inner characteristics of MOSFET, the gate driver makes to increase the efficiency of the power conversion and decrease operating heat. Computer simulations and to experimental results for a Buck Converter are presented in order to validate the proposed method.

  • PDF

The study of pulse diagnosis(服診) about twelve meridians(十二經脈) (고대(古代)의 경복진단법(經服診斷法) 중 십이경맥(十二經脈) 맥진(脈診)에 관(關)한 연구(硏究))

  • Lim, Seong-cheol;Son, Seong-cheol;Lee, Kyung-min;Hwang, Min-seob;Kim, Kap-sung;Yoon, Jong-hwa
    • Journal of Acupuncture Research
    • /
    • v.19 no.5
    • /
    • pp.1-9
    • /
    • 2002
  • Objective : The study of relations between twelve meridians and pulse diagnosis Method : The possiblity of pulse diagnosis on the pulse points(脈動處) of each meridian through the scription of $\ll$Maek beop(脈法)$\gg$ $\ll$Nae kyeong(內經)$\gg$ and $\ll$Nan kyeong(難經$\gg$ Result : The comparative pulse diagnosis method(比較脈診法) in the scription of $\ll$Mack beop$\gg$ progressed to the five Jang bu maek(五臟脈) in the scription of $\ll$Young chu : Sa gi jang bu byeong hyeong(靈樞 邪氣臟腑病形)$\gg$ in accordance with the progress of pulse diagnosis and the theory of medicine. Conclusions : The comparative pulse diagnosis method in the scription of $\ll$Mack beop)$\gg$ progressed to the five Jang bu maek(五臟脈) in the scription of $\ll$Young chu : Sa gi jang bu byeong hyeong$\gg$ and the moxibustion and Pyum bup(貶法) in the scription of $\ll$Mack beop$\gg$ altered to acupuncture therapy on the five shu points(五輸穴)

  • PDF

Design and Fabrication of X-Band 50 W Pulsed SSPA Using Pulse Modulation and Power Supply Switching Method (펄스 변조 및 전원 스위칭 방법을 혼용한 X-대역 50 W Pulsed SSPA 설계 및 제작)

  • Kim, Hyo-Jong;Yoon, Myoung-Han;Chang, Pil-Sik;Kim, Wan-Sik;Lee, Jong-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.4
    • /
    • pp.440-446
    • /
    • 2011
  • In this paper, a X-band 50 W pulsed solid state power amplifier(SSPA) is designed and fabricated for radar systems. The SSPA consists of a driver amplifier, a high power amplifier, and a pulse modulator. The high power stage employes four 25 W GaAs FET to deliver 50 W at X-band. To meet the stringent target specification for the SSPA, we used a new hybrid pulse switching method, which combine the advantage of pulse modulation and bias switching method. The fabricated SSPA shows a power gain of 44.2 dB, an output power of 50 W over a 1.12 GHz bandwidth. Also, pulse droop < 1 dB meet the design goals and a rise/fall time is less than 12.45 ns. Fabricated X-band pulsed SSPA size is compact with overall size of $150{\times}105{\times}30\;mm^3$.

Crack Depth Evaluation of Concrete Structures using Ultrasonic Pulse Velocity method (초음파 속도법을 이용한 콘크리트 구조물의 균열깊이 측정)

  • 오병환;김광수;김세훈
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.659-662
    • /
    • 1999
  • Ultrasonic pulse velocity method is employed for evaluation of crack depth in concrete structures. Due to the heterogeneous nature of concrete and the indirect transmission arrangement for the transit time measurement through the surface-opening cracks in concrete structures, ultrasonic pulse velocity has so many variations as crack depths and transmission lengths vary. In this study, ultrasonic pulse velocity method is investigated to evaluate the surface-opening crack depth of concrete slabs, reinforced concrete slabs, reinforced concrete flexural members. the resent study gives a modified method for deminishing errors in transit time measurements and show limitations to the evaluation of crack depth in reinforced concrete structures.

  • PDF

Approximation of Pulse Transfer Function of Impulse Response Data (임펄스응답 데이타의 펄스전달함수의 근사)

  • Lee, Dong-Cheol;Bae, Jong-Il;Chung, Hyeng-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 1999.07b
    • /
    • pp.683-685
    • /
    • 1999
  • As a method of obtaining pulse transfer function. transfer function of discrete-time from input-output data, there are method of obtaining unknown parameter of pulse transfer function from estimated impulse response before(1-3). There is no need to approximate to several meanings because of not being established algebraical relations between impulse response for estimation error and parameter of transfer function exactly. In this paper, I inquire the method[4] of obtaining the optimal pulse transfer function as a meaning of Hankel norm approximation from impulse response data and examine estimated property as computer simulation from this method.

  • PDF

A New Converter System of Reducing Harmonics by 2-3 Switching Taps on Interphase Reactor (2-3 ? 변환방식에 의한 새로운 고조파 저감형 컨버어터 시스템)

  • Lee, Seong-Ryong
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.24 no.4
    • /
    • pp.658-666
    • /
    • 1987
  • In this paper, a new mehtod of reducing harmonics that involved in input AC line currents or in output DC voltage of the converter system is presented. which is due mainly to the quipment of 2-3 switching taps on interphase reactor. In case that the 3 tap method is applicable to conventional 12 pulse converter, it could not bring to an effect of reducing harmonics under firing angle 15\ulcorner To solve these problems, 24 pulse or 36 pulse converter is controlled by microprocessor. The former is performed in 2 tap method when \ulcorneris less than 15\ulcorner the latter in 3 tap method when it is more then 15\ulcorner Therefore the originality of this paper liea in microprocessor based equipment of the 2-3 switching taps on interphase reactor. I applied this method to the 12 pulse converter, and proved validity of that theoretically and experimentally.

  • PDF